Manufactured by Fairbanks Scales, Inc.
821 Locust St.
Kansas City, Missouri 64106
07/13 3 51325 Rev. 1
Disclaimer
Every effort has been made to provide complete and accurate information in this manual. However,
although this manual may include a specifically identified warranty notice for the product, Fairbanks
Scales makes no representations or warranties with respect to the contents of this manual, and reserves
the right to make changes to this manual without notice when and as improvements are made.
Fairbanks Scales shall not be liable for any loss, damage, cost of repairs, incidental or consequential
damages of any kind, whether or not based on express or implied warranty, contract, negligence, or
strict liability arising in connection with the design, development, installation, or use of the scale.
This document contains proprietary information protected by copyright. All rights are reserved. No
part of this manual may be reproduced, copied, translated, or transmitted in any form or by any
means without prior written permission of the manufacturer.
07/13 4 51325 Rev. 1
Table of Contents
SECTION 1: GENERAL INFORMATION .................................................................. 6
This manual provides general installation and maintenance instructions for the
Fairbanks Scales’ 9104 FB Series Omnicell. Almost every installation is different, so
please adjust the following information, as needed, for your application.
Specifications, parameters and application notes are included.
This manual is meant to give general instructions for applying the Omnicell
considering its inherent capabilities and limitations; it is not meant to be a scale
design manual. Questions concerning specific applications should be directed to the
appropriate Product Manager.
For complete 9104 FB Series installation you will also need to reference the
necessary instrumentation manual.
1.2. INTRODUCTION
The 9104 FB Series Omnicell provides an extremely accurate method for weighing
medium to large capacity vessels, hoppers, and tanks. The 9104 FB Omnicells utilize
double-ended shear beam load cells in their design. This design is also effective
providing thermal expansion and contraction built-in support for applications that
require it. In most applications, the 9104 FB are self-checking with no need for
additional checking, making the 9104 FB Series Omnicell the mount of choice for
those areas with seismic activity.
1.3. DESCRIPTION
Fairbanks Scales’ Omnicells are a combination of two main components:
• Mounting assembly (captivates the load cell and provides means to fasten to
the vessel and flooring).
• Load cell (the actual weight detecting device).
The 9104 FB Series Omnicells will arrive preassembled, including the load cells. This
mounting assembly is specifically designed to be installed with the load cell.
The 9104 FB Series Omnicells are available in standard capacities ranging from 1K to
75K lbs.
The load cells are constructed from stainless steel or mild alloy steel in a doubleended shear beam design.
The mounting assembly is available in either a nickel-plated mild alloy steel or
stainless steel construction.
07/13 6 51325 Rev. 1
Dimensional Reference Chart (Inches)
Secti on 1 : General Information
These Omnicells are designed to be mechanically fastened to the load carrier and the
foundation fasteners are not included.
Prior to installation,
equipment satisfies the customer's requirements as
supplied, and as described in this manual.
If the equipment cannot satisfy the
application and the application cannot be
modified to meet the design parameters of
the equipment, the installation should
be attempted.
It is the customer/operator's responsibility to ensure the equipment provided
by Fairbanks is operated within the parameters of the equipment's specifications
and protected from accidental or malicious damage.
always
verify that the
NOT
WARNING
(other than selection of standard options and accessories)
may be made to this equipment by customers.
Repairs must be performed by Fairbanks Scales service technicians
and authorized distributor personnel ONLY!
Failure to comply with this policy
voids all implied and/or written warranties.
07/13 8 51325 Rev. 1
Secti on 2 : Company Service Information
2.2. OVERVIEW
2.2.1. Physical Installation Notes
•
Check all devices for proper operation. If any error messages occur, refer to
Troubleshooting or the proper manual of that device.
•
Only those charges which are incurred as a result of the equipment's
inability to be adjusted to performance specifications may be charged to
warranty.
•
No physical alterations (mounting holes, etc.) are allowed during installation.
The installing technician is responsible that all personnel are
fully trained and familiar with the equipment's capabilities and
limitations before the installation is considered complete.
•
All electrical assemblies must be replaced as assemblies or units.
─ Replacement of individual components is not allowed.
─ These components must be returned intact for replacement credit per normal
procedures.
•
All electronic and mechanical adjustments are considered to be part of the
installation, and are included in the installation charge(s).
─ Included is any required computer programming or upgrades.
─ Included are any accuracy and/or operational specification changes.
•
The AC receptacle / outlet shall be located near the Instrument and easily
accessible.
•
Electrical connections other than those specified may not be performed.
2.2.2. Conferring with our Client
•
The technician must be prepared to recommend the arrangement of components
which provide the most efficient layout, utilizing the equipment to the best
possible advantage.
•
The warranty policy must be explained and reviewed with the customer.
07/13 9 51325 Rev. 1