Fadini Elpro s40 User Manual

Page 1
pag. 1,2,3,4,5
®
LIBRETTO DI ISTRUZIONI
I
PROGRAMMATORE A MICROPROCESSORE
PER DISSUASORI A SCOMPARSA
INSTRUCTIONS
GB
ELECTRONIC PROGRAMMER WITH
MICROPROCESSOR FOR RISING BOLLARDS
NOTICES D’INSTRUCTION
F
PROGRAMMATEUR A MICROPROCESSEUR
POUR BORNES ESCAMOTABLES
D
MIKROPROZESSORSTEUERUNG
FÜR VERSENKBARE ABSPERRPOLLER
S40
S40
S40
ANLEITUNG
S40
- APERTURA PEDONALE
- PREDISPOSTO PER SEMAFORO A 3 LUCI
- AUTOMATICO O SEMIAUTOMATICO
- COLLEGAMENTI SEPARATI PER ELETTROVALVOLA
- SISTEMA DI SUPERVISIONE INTEGRITÀ C.S.I.
- UP TO 4 BOLLARDS
- STEP-BY-STEP FUNCTION
- PEDESTRIAN OPENING
- PREPARED FOR 3 LAMPS TRAFFIC LIGHTS
- AUTOMATIC OR SEMI- AUTOMATIC
- SEPARATE CONNECTIONS FOR ELECTRIC VALVE
- JUSQU’A 4 BORNES ESCAMOTABLES
- OUVERTURE PIETONS
- PREPARE POUR FEU DE CIRCULATION A 3 AMPOULES
- AUTOMATIQUE OU SEMIAUTOMATIQUE
- RACCORDEMENTS SEPARES POUR ELECTROVANNE
- CIRCUIT DE SUPERVISION D’INTEGRITE C.S.I.
- BIS ZU 4 VERSENKBAREN ABSPERRPOLLERN
- GEHTÜRFUNKTION
- FÜR AMPEL MIT 3 LICHTERN VORGESEHEN
- AUTOMATIK- ODER HALBAUTOMATIKBETRIEB
- GETRENNTE ANSCHLÜSSE FÜR ELEKTROVENTIL
- SYSTEM ZUR KONTROLLE DER INTEGRITÄT (I.Ü.S.)
- PREDISPOSIZIONE PER OROLOGIO ESTERNO
- FUNZIONE PASSO-PASSO
- UOMO PRESENTE
- EXTERNAL TIME CLOCK
- DEADMAN CONTROL
- ISC SYSTEM i.e. INTEGRITY SUPERVISION
page 1,6,7,8,9
- PREPARE POUR HORLOGE EXTERNE
- FONCTION PAS-PAS
- HOMME MORT
page 1,10,11,12,13
- FÜR EXTERNE UHR VORGESEHEN
- IMPULSBETRIEB
- TOTMANN-BETRIEB
Seite 1,14,15,16,17
FOLLETO DE INSTRUCCIONES
E
PROGRAMADOR DE MICROPROCESADOR
PARA BARRERAS ESCAMOTEABLES
S40
HANDLEIDING
NL
PROGRAMMEERINRICHTING MET
MICROPROCESSOR VOOR VERZINKBARE PALEN
S40
- HASTA 4 BARRERAS ESCAMOTEABLES
- ABERTURA PEATONAL
- PREDISPUESTO PARA SEMÁFORO DE 3 LUCES
- AUTOMÁTICO O SEMIAUTOMÁTICO
- CONEXIONES SEPARADAS PARA ELECTROVÁLVULA
- SISTEMA DE SUPERVISIÓN INTEGRIDAD C.S.I.
- MAXIMAAL 4 VERZINKBARE PALEN
- VOETGANGERSDOORGANG
- VOORBEREID VOOR STOPLICHT MET 3 LICHTEN
- AUTOMATISCH OF HALFAUTOMATISCH
- GESCHEIDEN VERBINDINGEN VOOR MAGNEETKLEP
- BEWAKINGSSYSTEEM INTEGRITEIT C.S.I.
1234
- PREDISPOSICIÓN PARA RELOJ EXTERNO
- FUNCIÓN PASO-PASO
- HOMBRE PRESENTE
pág. 1,18,19,20,21
- VOORBEREIDING VOOR EXTERNE KLOK
- STAP-VOOR-STAP FUNCTIE
- DODEMANSFUNCTIE
pag. 1,22,23,24,25
1
2
3
4
Dis. N.
4555
Via Mantova, 177/A - 37053 Cerea (Verona) Italy - Tel. +39 0442 330422 r.a.
®
Fax +39 0442 331054 - e-mail: info@fadini.net - www.fadini.net
s.n.c.
1
Page 2
®
GB
S40
ELECTRONIC PROGRAMMER UP TO 4 BOLLARDS WITH OR WITHOUT LIMIT SWITCHES
Red
Common
Yellow
Green
63 64 65 66 60 61
Power supply 230V
Fuse 1A
Red Yellow Green
(Optional: Plug-in PCB for traffic light to suit 230 V lamp)
code 7282
“STRIP” jumper
50Hz
PLUG-IN CONNECTOR FOR 3­LAMP TRAFFIC LIGHTS MAX 100W EACH LAMP
-
+
T1
MOTOR RUN TIME
1s - 22s
DIP-SWITCH
14567823
RADIO PLUG-IN CARD CONNECTOR
L1
Input P
57 58
Motor Bollard M1
1
connection
MAGNETIC LOOP
Pedestrian opening
9101112
Elpro S40
L3
L2
2
3
OPEN
PHOTOCELLS OR
COMMON
+-
24V DC output
-
T2
DWELL TIME
1s - 180s
ON
OFF
L5
L4
74
RADIO
CLOSE
STOP
55 56
+
L6
85
96
LED 24V 3W max
n°1 Radio receiver
L12 L13 L14 L15
26 27 28 29 30
COMMON
(Bollard in down position)
(Bollard in up position)
(Bollard in down position)
LIMIT SWITCH OPEN M3
L7
10
n°2 pairs of photocells
OUTPUT 24V for max charge
LIMIT SWITCH OPEN M4
LIMIT SWITCH CLOSE M3
L8
L9
11
12
in down position)
LIMIT SWITCH OPEN M1 (Bollard
(Bollard in up position)
Secondary
fuse
transformer
F4= 2A
M3A M3C M4A M4C
μF
Cond. 20 M3
COMMON
(Bollard in up position)
LIMIT SWITCH CLOSE M4
M3
Bollard n°3
MOTOR M3
3
Capacitor 20
L10 L11
13
14 15
COMMON
(Bollard in up position)
LIMIT SWITCH CLOSE M2
LIMIT SWITCH CLOSE M1
(Bollard in down position)
LIMIT SWITCH OPEN M2
20VA 50/60Hz
TRANSFORMER
μF
Cond. 20
M4
AA
BB
34
36
35
333132
COMMON
M4
MOTOR M4
Bollard n°4
Fuse
Motore M4
F6= 5A
Fusle Motor
M3 F7= 5A
4
COMMON
M1
Bollard n°1
B
181617
MOTOR M1
Capacitor 20
A
19
20
COMMON
M2
MOTOR M2
Bollard n°2
21
μF M1
A
12
Primary
fuse transformer
F3= 630mA
51 52 53
Electric valve fuse,
Acoustic device, Flashing
light and Led F5=1A
Motor fuse M2
Motor fuse M1
μF M2
Anti-disturbance filter
B
2322 24 25
ELECTRIC VAL
POWER SUPPL
230V 50Hz
VE
Y
COMMON
100W MAX
230V 100W max
FLASHING LIGHT
F2= 5A
F1= 5A
NEUTRAL
F
N
230V ±10% 50Hz
SINGLE- PHASE
SIGNAL LIGHT 230V
LIVE
POWER SUPPL
Y
LIMIT SWITCH DIAGNOSTIC:
Strabuc 918, Strabuc 930 Heavy Armoured, Strabuc 930 Opinat range of bollards:
With the “STRIP” jumper inserted (as in the picture), Elpro S40 checks cyclicly every 10 minutes that the closing limit switches (post raised) are in the correct position; should any of them fail to be such, only the motor of the post not in position is operated until this is fully up as required.
Note well: Whenever Elpro S40 is re-powered, wait 10 seconds for the logic to become fully operating again.
The electronic control panel Elpro S40, new generation, is designed to operate the Strabuc, Coral and Vigilo. Power supply is 230V single-phase. Built in full compliance with 2006/95/CE Low Voltage Directive and 2004/108/CEE & 92/31/CEE Electro-Magnetic Compatibility Directive. Fitting operations are recommended by a qualified technician in conformity to the existing safety standards. Elpro S40 is capable of monitoring damages or malfunctioning with the system (ISC) I.S.C.= Integrity and Supervision Circuit, is a special function of Elpro S40 which can self control the electronic PCB and detect any damages occurring with any components or accessories. In this case, provided that the post is fitted with a release electric valve, lowering is allowed automatically. The manufacturing company declines any responsability for incorrect handling and application; also, it reserves the right to change or update the control panel any time.
PLEASE NOTE:
- The control panel must be installed in a sheltered, dry place, inside the box provided with it.
- Fit the mains to the control panel with a 0.03A high performance circuit breaker.
- Use 1.5mm
2
section wires for voltage supply, electric motor and flashing lamp. Maximum recommended distance 50m.
- Use 1mm2 section wires for limit switches, photocells, push-buttons/key- switch and accessories. N.W: To fit extra accessories such as lights, CCTV etc. use only solid state relays to prevent damages to the microprocessor.
Coral and Vigilo range of posts: For the posts that are fitted only with the opening limit switch, position the “STRIP” jumper as in the picture to achieve a correct performance of the system.
6
Drwg. No.
4555
Page 3
GB
S40
ELECTRONIC PROGRAMMER UP TO 4 BOLLARDS WITH OR WITHOUT LIMIT SWITCHES
IN CASE OF FAILURE OF THE PANEL:
- Check the electronic PCB voltage supply is 230V ±10%
- Check the electric motor power supply is 230 V ±10%
- For longer distances increase wire section
- Check power supply 230V single-phase
- Check fuses
- Check all NC contacts
- Check that no voltage drop has occurred from the control board to the electric motor
- In case the electric valve is fitted, check integrity with all fuses
®
1234
1
2
3
4
LED STATUS INDICATION
L1= Pedestrian opening, normally OFF, alight when a pedestrian open pulse is given L2= Photocells or loop, normally ALIGHT, if obstructed light goes off L3= Open, normally OFF, alight when an open pulse is given L4= Close, normally OFF, alight when a close pulse is given L5= Stop, normally ON, it goes off when a stop pulse is given L6= Radio, normally OFF, alight when a Radio pulse is given L7= Normally ON, mains voltage and fuse integrity F1, F2, F3, F4 L8= Limit switch open M1, normally ON, it goes off when the post is in down position L9= Limit switch close M1, normally ON, it goes off when the post is in up position L10= Limit switch open M2, normally ON, it goes off when the post is in down position L11= Limit switch close M2, normally ON, it goes off when the post is in up position L12= Limit switch open M3, normally ON, it goes off when the post is in down position L13= Limit switch close M3, normally ON, it goes off when the post is in up position L14= Limit switch open M4, normally ON, it goes off when the post is in down position L15= Limit switch close M4, normally ON, it goes off when the post is in up position
LOW VOLTAGE ELECTRICAL CONNECTIONS
Photocells or Loop Detectors:
2
1
PHOTOCELLS OR
LOOP DETECTORS
910
24V OUTPUT (MAX. LOAD:
2 PAIRS PHOTOCELLS
1 RADIO RECEIVER)
DIP-SWITCH 1:
ON: Photocells or loop stop while opening,
OFF: Photocells or loop do not stop while
1
DIP-SWITCH 11:
ON: During dwell time, Automatic mode
11
OFF: It does not close after engaging
DIP-SWITCHES
1= ON Photocells or loop stop while opening 2= ON Radio no reversing while opening 3= ON Automatic closing 4= ON Pre flashing activated 5= ON Radio step by step stop in between 6= ON Pedestrian opening Motor M1only one post operating 7= ON Deadman control 8= Traffic lights (see functions) 9= Traffic lights (see functions) 10= ON No lamp on during dwell time 11= ON Close on dwell time after passage through photocells or over the loop 12= ON Max working time 90s. OFF= 18s
reverse on closing once obstacle is removed
opening, reverse on closing in case of an obstacle
(Dip-Switch 3=ON) after engaging the photocells or loop, it closes 5s later
the photocells or loop
14567823
9101112
ON
OFF
Key switch:
Radio Contact:
- Open/Close (standard mode)
- It reverses at any pulse
- Step by step
4
3
COMMON
OPEN
3
COMMON
24V 3W Movement Indication Light:
Light ON= Post in down position, free passage Light OFF= Post in up position, closed passage Flashing 0,5s (fast)= rising post Flashing 1s (normally)= lowering post With external clock: 2 short flashes followed by a longer pause
Drwg. No.
4555
5
6
NONO NC
CLOSE
STOP
7
CONTACT
RADIO
3
COMMON
DIP-SWITCH 2:
ON: It does not reverse on opening
OFF: It reverses at any pulse
2
8
24V DC Output:
Output for 24V D.C. applications
DIP-SWITCH 5:
ON: Step by step with stop in between
OFF: Standard operation
5
+-
55
200mA for accessories
56
7
Page 4
ELECTRICAL POWER CONNECTIONS
FADINI
®
GB
S40
ELECTRONIC PROGRAMMER UP TO 4 BOLLARDS WITH OR WITHOUT LIMIT SWITCHES
Motors:
Important: when doing the electric power
connections it is better to connect only one motor and its respective limit switches. Put the posts into phase one by one.
-
+
T1
MOTOR RUN TIME
1s - 22s
DIP-SWITCH 12:
ON: Motor run time max 90s
12
OFF: Motor run time max 18s
-
+
T2
DWELL TIME
1s - 180s
Limit switch:
There is no need to bridge the limit switch inputs of the posts which are not present in the installation
IMPORTANT: For Coral and Vigilo:
1) place the “STRIP” as indicated on page 6
2) bridge the closing limit switches inputs 12 and 15 (which are not used) with the common 13 and the inputs 27 and 30 (which are not used) with the common 28
20μF additional capacitor in
case of power shortage for
Motor M1
AB AB AB AB
181617
COMMON
M1
MOTOR M1 Post n°1
20μF additional capacitor in
case of power shortage for
Motor M2
19
21
20
COMMON
M2
MOTOR M2 Post n°2
11
12
(Post in down position
LIMIT SWITCH OPEN
(Post in up position
)
M1
)
20μF additional capacitor in
case of power shortage for
MOTOR M3 Post n°3
13
14 15
(Post in up position)
(Post in down position
COMMON LIMIT SWITCH
LIMIT SWITCH OPEN
LIMIT SWITCH CLOSE
M2
)
M1
Motor M3
333132
COMMON
M3
LIMIT SWITCH CLOSE
M2
(Post in down position)
20μF additional capacitor in
case of power shortage for
26 27 28 29 30
LIMIT SWITCH OPEN
M3
COMMON LIMIT SWITCH
(Post in down position
(Post in up position
LIMIT SWITCH CLOSE
)
)
M3
Motor M4
34
MOTOR M4 Post n°4
(Post in up position)
LIMIT SWITCH OPEN
M4
36
35
COMMON
M4
LIMIT SWITCH CLOSE
M4
Electric valve power supply:
In case of power failure , electronic programmer malfunctionning, or a burnt fuse , should an electric valve be installed, the bollard lowers automatically
External flashing light:
It is possible to connect both the external Flashing light and the intermittent signal led lights which are on only during the rising and lowering movement. The cable for the connection is the one labelled as flashing lights cable
Signal led lights (for the “Strabuc” range only):
Output for intermittent signal led lights during the movement both rising and lowering and also on dwell in up position: the lights are off only when the bollard is in down position. Connect the Blue-Common wire and the Brown wire of the bollard flashing light cable.
Acoustic signal “Beeper” during movement (optional accessory for the “Strabuc” range only):
The acoustic signal device inside the bollard is active during rising and lowering. The connection wires are the
Common and the Black one of the flashing light cable
Blue-
2322 24 25
ELECTRIC VALVE POWER SUPPLY
230V 50Hz
51 52 53
COMMON
230V 100W MAX
51 52 53
SIGNAL LED LIGHTS OUTPUT
230V 100W MAX
51 52 53
BLACK
ACOUSTIC SIGNAL DEVICE OUTPUT 230V 100W MAX
BLUE
BLUE
COMMON
COMMON
BROWN
DIP-SWITCH 4 and 10:
ON: Pre-flashing OFF: No pre-flashing
4
ON: Flashing light out of service
on Dwell Time. Automatic mode
OFF: Light flashes on Dwell Time.
10
Automatic mode
l’apricancello
PCB power supply:
Electronic programmer power supply
8
Drwg. No.
4555
2322 24 25
LIVE
N
F
NEUTRAL
PCB POWER SUPPLY
±10%
230V 50Hz SINGLE PHASE
Page 5
GB
FUNCTIONS
S40
ELECTRONIC PROGRAMMER UP TO 4 BOLLARDS WITH OR WITHOUT LIMIT SWITCHES
®
Automatic / Semi-automatic:
Automatic cycle: after an opening pulse, the bollard goes down, it stops for dwell time pre-set in trimmer
T2, after the pre-set time it closes automatically
Semi-Automatic: after an opening pulse, the bollard goes down. A closing pulse is needed to close.
Pedestrian Opening:
This command is separate from the standard opening command. When all the posts are in up position, on pulsing input P Dip-Switch 6= On, and 3=On , post n°1 (Motor M1) goes down for pedestrian opening, for the time pre-set in Trimmer T2, after this time it closes automatically
Input P
57 58
Pedestrian opening
contact terminals
Post Motor M1
Hold on switched (Deadman) control:
Open and Close operations are achieved “by holding a switch on” (no relay self-holding is involved) therefore a physical attendance is required to keep the post opening or closing until either the button or key is released.
DIP-SWITCH 3 - 6 both on ON
ON= Automatic closing OFF= No automatic closing
3
semi-automatic closing
ON= Pedestrian opening Motor M1 OFF= Standard operation
6
DIP-SWITCH 7
ON= Deadman control
OFF= Standard operations
7
-
T2
Dwell time
from 1 to 180s
External Clock (Optional):
CLOCK: The electronic programmer Elpro S 40 can be connected to a clock for the post opening and closing Connection: connect in parallel the NO clock contact to the 4 OPEN and 3 COMMON terminals, automatic closing is by Dip-Switch n°3=ON
How it works: Set the clock to the required time. On the pre-set time the post is automatically opened (the post goes down) and held open (the flashing light goes off and the led flahes twice and dwells). Any further pulsing (even by remote control) is not accepted by the system until the time pre-set by the clock has expired. On expiring and after the pre-set dwell time the post rises automatically.
+
DIP-SWITCH 3
ON= Automatic closing OFF= No automatic closing.
3
Semi-automatic function
-
Dwell time
from 1 to 180s
M1
COMMON
M2
43
OPEN
+
T2
External clock
M3
NO
M4
COMMON
DIP-SWITCH N°3=ON Automatic closing
+
-
T2
from 1 to 180s
Dwell time
ON= Automatic closing
OFF= No automatic closing.
3
Semi-automatic function
Plug-in traffic lights interface (Optional):
The interface power supply (230V 50Hz 100W output per lamp) is independent from the one of the programmer. It can work also with the 2 lamps, Red and Green traffic lights (Dip Switch 8=OFF and 9=OFF) Working logic:
- GREEN Light= Post in down position, OPEN passage
- RED Light= Moving post or in up position, CLOSED passage
- YELLOW Light= it lights before the switching from the Green light to the Red light
Note: During Pedestrian mode the traffic light is always RED.
DIP-SWITCHES 8 and 9
OFF
8
ON
8
OFF
8 9
ON
8
Dip-Switch 8=OFF and 9=OFF The yellow light turns on for the time of 0s and after 0s the Red
OFF
light turns on and the post starts rising immediately
9
Dip-Switch 8=ON and 9=OFF The yellow light turns on for the time of 2s then the Red light
OFF
turns on and after 2s the post starts rising
9
Dip-Switch 8=OFF and 9=ON
ON
The yellow light turns on for the time of 6s then the Red light turns on and after 5s the post starts rising
ON
Dip-Switch 8=ON and 9=ON The yellow light turns on for the time of 10s then the Red
9
light turns on and after 7s the post starts rising
(Optional: Plug-in PCB for
Red
Yellow
Green
63 64 65 66 60 61
Fuse 1A
230V traffic lights)
RED
YELLOW
GREEN
Common Power supply 230V 50Hz
Red
Yellow
Green
code 7282
Drwg. No.
4555
9
Page 6
200
182
05-2009
260 280
110
I -
Prima dell’installazione da parte di personale tecnico qualificato, si consiglia di prendere visione del Libretto Normative di Sicurezza che la Meccanica Fadini mette a disposizione.
GB -
Please note that installation must be carried out by qualified technicians following Meccanica Fadini’s Safety Norms Manual.
F -
L’installation doit être effectuée par un technicien qualifié suivant le manuel des Normes de Sécurité de Meccanica Fadini.
D -
Vor der Montage durch einen Fachmann, wird es empfohlen die Anleitung zur Sicherheitsnormen, die Meccanica Fadini zur Verfügung stellt, nachzulesen.
E -
Antes de la instalación por el personal técnico calificado, se recomienda leer detenidamente el Folleto de la Reglamentación de Seguridad que la empresa Meccanica Fadini pone a su disposición.
NL -
Voordat de installatie door gekwalificeerd technisch personeel wordt uitgevoerd, wordt geadviseerd om het boekje met veiligheidsvoorschriften dat Meccanica Fadini ter beschikking stelt door te lezen.
Direttiva 2003/108/CE Smaltimento dei materiali
I
elettrici ed elettronici
VIETATO GETTARE NEI RIFIUTI
MATERIALI NOCIVI PER L’AMBIENTE
2003/108/CE Directive
for waste electrical and
GB
electronic equipments
DISPOSE OF PROPERLY
ENVIRONMENT-NOXIOUS MATERIALS
®
s.n.c.
Via Mantova, 177/A - 37053 Cerea (Verona) Italy - Tel. +39 0442 330422 r.a. - Fax +39 0442 331054
e-mail: info@fadini.net - www.fadini.net