I
GB
F
D
E
NL
Elpro 980
LIBRETTO DI ISTRUZIONI
Programmatore a microprocessore per Barriere stradali Bayt 980
INSTRUCTIONS
Control box with microprocessor for Bayt 980 road barriers
NOTICES D'INSTRUCTION
Programmateur à microprocesseur pour Barrières routières Bayt 980
-FUNZIONE PASSO-PASSO
-UOMO PRESENTE
-PREDISPOSTO PER SEMAFORO A 3 LUCI
-AUTOMATICO O SEMIAUTOMATICO
-SISTEMA DI SUPERVISIONE SICUREZZE
-PREDISPOSIZIONE PER OROLOGIO ESTERNO
-PREDISPOSIZIONE PER N°2 BAYT 980 SIMULTANEE
-STEP BY STEP
-DEADMAN CONTROL
-PRESET FOR TRAFFIC LIGHTS with 3 lamps
-AUTOMATIC OR SEMI-AUTOMATIC
-SAFETY DEVICE SUPERVISION / WATCHDOG
-PRESET FOR EXTERNAL TIME CLOCK
-PRESET FOR 2 BAYT 980's SIMULTANEOUS
-FONCTION PAS-PAS
-HOMME MORT
-PREREGLAGE POUR FEU DE CIRCULATION A 3 LUMIERES
-AUTOMATIQUE OU SEMIAUTOMATIQUE
-SYSTEME DE SUPERVISION SECURITES
-PREREGLAGE POUR HORLOGE EXTERNE
-PREREGLAGE POUR N°2 BAYT 980 SIMULTANEES
l'apricancello
Made in Italy
pag. 2,3,4,5
pages 6,7,8,9
pages 10,11,12,13
|
- SCHRITT-IMPULS-FUNKTION |
|
ANLEITUNG |
- TOTMANN-BEDIENUNG |
|
- VORGESEHEN FÜR AMPEL MIT 3 LICHTERN |
|
|
|
|
|
|
- AUTOMATISCH ODER HALBAUTOMATISCH |
|
E-Steuerung mit Mikroprozessor |
- ÜBERWACHUNGSSYSTEM DER SICHERHEITSVORRICHTUNGEN |
|
für Strassenschranke Bayt 980 |
- VORGESEHEN FÜR EXTERNE UHR |
Seite 14,15,16,17 |
|
- VORGESEHEN FÜR 2 GLEICHZEITIGE BAYT 980 |
FOLLETO DE INSTRUCCIONES
Programador de microprocesador para Barreras para pasos de
carretera Bayt 980
GEBRUIKSAANWIJZING
Programmeereenheid met microprocessor voor
verkeersbarrières Bayt 980
-FUNCION PASO A PASO
-HOMBRE PRESENTE
-PREDISPUESTO PARA SEMAFORO DE 3 LUCES
-AUTOMATICO O SEMIAUTOMATICO
-SISTEMA DE SUPERVISION DE LAS SEGURIDADES
-PREDISPOSICION PARA RELOJ EXTERIOR
-PREDISPOSICION PARA 2 BAYT 980 SIMULTANEAS
-STAP-VOOR-STAP FUNCTIE
-AANWEZIGHEID PERSOON
-UITGERUST VOOR STOPLICHTEN MET 3 LAMPEN
-AUTOMATISCH OF SEMI-AUTOMATISCH
-SYSTEEM VOOR TOEZICHT VEILIGHEIDSINRICHTINGEN
-INSTELLING VOOR EXTERNE KLOK
-INSTELLING VOOR 2 SIMULTANE BAYT 980
pág. 18,19,20,21
pag. 22,23,24,25
|
meccanica |
Dis. N. 5755 |
FADINI |
Via Mantova 177/A - C.P. 126 - 37053 Cerea (Verona) Italy
Tel. +39 0442 330422 - Fax +39 0442 331054 e-mail: info@fadini.net - www.fadini.net
GB Elpro 980 ELECTRONIC CONTROL BOARD
FOR ROAD BARRIERS BAYT 980
the gate opener
Made in Italy
ATTENTION !! The installation of this "electronic control board" requires a specific technical knowledge and must be carried out by professional installation
!agents, who are qualified and certified to operate in compliance with the existing safety norms.
It is important to read and keep to these instructions to prevent any wrong use or incorrect installation of the board. The electronic control board ELPRO 980 has been designed and developed to control the oil-hydraulic road barriers BAYT 980s. Any different applications are forbidden, unless specified in this manual.
ATTENTION !! Meccanica Fadini declines any responsibility for damages to persons or properties caused by the incorrect application of the product or for failing
!to observe the existing norms. The observance of the Machinery Directive 2006/42/CE is compulsory Maintenance and inspections of the status of the product must be carried out by qualified technicians.
ATTENTION !! Before servicing, do not forget to disconnect the power supply.
!It is also recommended to read the Safety Norms manual available from Meccanica Fadini. The manufacturing company is not liable for the "electronic control board" in case of misuse.
1st Operation:
Cover
1st Operation: undo the 3 screws (one outside and two inside the housing) and remove the Bayt 980 cover.
2nd Operation: Once removed the Bayt 980 cover, it is possible to see the container where Elpro 980 control board is enclosed.
3rd Operation: Undo the 4 screws and remove the container lid; the PCB is positioned on the right.
2nd Operation:
Cover
Container |
3rd Operation: |
with PCB |
|
Elpro 980 |
|
PCB
Elpro 980
Barrier Bayt 980
GB |
|
|
|
DECLARATION OF CONFORMITY |
||||
|
meccanica |
|||||||
The Manufacturer: |
|
|
Via Mantova 177/A - C.P. 126 - 37053 Cerea (VR) Italy Tel. +39 0442 330422 - Fax +39 0442 331054 |
|||||
FADINI e-mail: info@fadini.net - www.fadini.net |
||||||||
|
|
|||||||
|
|
|
|
DECLARES UNDER HIS OWN RESPONSIBILITY THAT: |
||||
Model: |
Elpro 980 electronic control box with microprocessor |
|||||||
|
|
|
IS IN COMPLIANCE WITH THE MACHINERY DIRECTIVE ............2006/42/CE |
|||||
Elpro 980 is to be installed into an |
"Automatic System", including the accessories and components as recommended by |
|||||||
the Manufacturing Company. |
|
|
|
|
|
|
||
The manufacturing company is not liable for incorrect applications or misuse of the products, that are produced in compliance |
||||||||
with the following norms: |
|
|
|
|
|
|
||
- Law Voltage Directive |
|
|
|
2006/95 CE |
||||
- Electro-magnetic Compatibility Directive |
|
2004/108/CE & 92/31 CEE |
||||||
|
In order to certify the product the Manufacturer declares under his own responsibility the compliance with |
|||||||
|
|
|
|
the PRODUCT NORMS .........................EN 13241-1 |
||||
|
03-03-2010 |
|
|
|
Meccanica Fadini s.n.c. |
|||
Date: |
|
|
|
Direttore Responsabile |
|
|||
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
the Responsible Manager |
page 6 Drw. N. 5755
GB Elpro 980 CONTROL BOX WITH MICROPROCESSOR FOR ROAD BARRIERS BAYT 980
the gate opener
Made in Italy
DIAGNOSTIC LEDS |
"Led" |
L1= Photo cells, it switches off in case of an obstacle L2= Open, it illuminates on pulsing to open
L3= Close, it illuminates on pulsing to close L4= Stop, it switches off on pulsing to stop
L5= Radio, it illuminates whenever a transmitter is pulsed L6= Limit switch Closing, off with gate in closed position L7= Limit switch Opening, off with gate in open position L8= Power supply 230V 50Hz illuminated
PHOTO CELLS AND SAFETY EDGES |
COMMON |
OPENING |
CLOSING |
STOP |
RADIO |
LIMIT SWITCH CLOSING |
LIMIT SWITCH COMMON |
LIMIT SWITCH OPENING |
LIGHT “ON” 24V-3W - Beam in vertical position |
OUTPUT 24V ~ 350mA max load: n°2 pairs Photo cells n°1 Radio receiver |
Output connections of the 2nd Elpro 980 for the 2nd BARRIER "B"
COMMON |
OPENING |
CLOSING |
Red |
Yellow |
Green |
Common |
Power supply |
230V 50Hz |
|
|
63 64 |
65 66 |
60 |
61 |
|
|
|
|
|
Fuse 1A |
- |
+ |
|
|
|
|
|
|
DWELL TIME |
|
|
|
|
Red |
from 5 to 128s |
||
|
|
|
Yellow |
|
|
|
|
|
|
Green |
|
F1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
2A mains |
Traffic lights plug-in card (Optional on request):
- Power supply 230V, lamp output 230V
- Power supply 24V, lamp output 24V SINGLE-PHASE 230V 50Hz
POWER SUPPLY
FLASHING LAMP 230V 25W max
SINGLE-PHASE M MOTOR |
|
M |
|||||||||||||
|
DRIVE UNIT COS 982 |
|
|||||||||||||
|
|
|
|||||||||||||
DIP-SWITCH |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1= ON Photo cells stop barrier on Opening |
|
|
|
|
|
|
|
DIP-SWITCH |
|
|
|||||
2= ON Radio. No reversing (no stopping) on Opening |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3= ON Automatic closing |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
4= ON Pre-flashing in service |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
5= ON Radio. Step by step with stop in between |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
6= ON Deadman control (Dip 4=OFF and Dip 3=OFF) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
7= ON Deadman control only on Closing cycle |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
8= ON Flashing lamp off on dwell cycle |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
9= ON On Opening/Dwelling beam lowers after passing the photo cells.
10= ON All operations Opening/Closing after checking status of safety devices assessing clearance from obstacles and operativity
11= OFF, blank.
12= ON Activation of the second board (slave mode)
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
Traffic lights connector
LIVE |
22 |
|
NEUTRAL |
||
21 |
||
|
||
|
20 |
|
|
19 |
|
COMMON |
18 |
|
17 |
||
|
||
|
16 |
ON
OFF
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 12 13 |
|
+24V=_ |
|
|
|
|
|
|
|
|
|
|
C. Ap Ch |
||
|
|
|
|
|
|
|
|
|
|
27 |
28 29 |
23 24 |
SCHEDASEMAFORO
F1
16 181720192221
|
TEMPO |
_ |
+ |
|
|
|
|
||
|
PAUSA |
|
|
|
|
980 E 0.V1 |
|
|
|
|
RADIO FADINI |
|
|
|
2A |
SITI-JUBI-BIRIO |
|
|
|
|
|
|
|
|
DANGER |
|
|
|
|
5A |
630mA |
|
|
|
|
|
|
1224/26/08/M |
|
F2 |
F3 |
MOD. ELPRO |
COMELIT POT. 20VA 50/60Hz PRI: 230V SEC: 24V - 0.83A |
Made in Italy |
SCHURTER DFKH2-31-4,0-3,3/a |
4,0A - 3,3mH |
A5C08
2 1 |
ON |
5 4 3 |
|
1211 10 9 8 7 6 |
|
24 Vdc 150mA
+ _
Blue led fitted to the housing
Dip-switch for service programming
Plug-in radio card connector
630mA Transformer protection
F2 F3
Fuse
MMotor 5A
Drwg. 5940
General Description: Elpro 980 is a control board with a microprocessor to operate the electro-hydraulic road barriers in the range of Bayt 980. Power supply: 230V 50Hz±10% single-phase. In compliance with the Low Voltage Safety Norms 2006/95 CE and Electro-Magnetic Compatibility 2004/108/CE - 92/31/CEE. The electrical connections for the mains power supply are well separated from the low voltage connections for the commanding and safety accessories. It includes a 5A fuse to protect the board and the motor, a 630 mA primary transformer, and a 2A secondary transformer.
Operating logic : After an Opening pulse, an Opening-Dwell-Closing cycle is started either in automatic or semi-automatic mode. The following options can be selected: step by step by remote control, non reversing by remote control on Opening cycle , pre-flashing or non pre-flashing, flashing lamp On - Off options in Dwell phase, deadman control in both O/C cycles or only on Closing, Leds are fitted to provide status diagnostic of the system inputs.
The control board incorporates a special safety feature: the unit checks automaticaly, even if the motor is stopped, that no movement of the beam occurs unless the safety accessories connected to the system, such as the photocells, safety edges or loop detectors, are cleared from any obstacle.
In the case where two barriers are required alike in length and speed to operate simultanueously (with very large lanes), it is possible to connect the two ELPRO 980s using only three cables to the outputs 27/28/29 and, obviously, to the 230V power supply. In this way, one barrier becomes the master (to which all the commanding and safety accessories are to be connected), and controls the secondary one (slave). The safety contacts (Stop, Photocells) of the second barrier are to be linked out.
IN CASE OF FAILURE:
-Check that the power supply to the electronic board is 230V ±10% 50 Hz
-Check that the power supply to the electric motor is 230V ±10% 50 Hz
-For distances beyond 50 metres increase the section of the wires.
-Check the fuses.
-Check all the normally closed contacts.
-Check that no power drop occurs between the board and the electric motor.
2003/108/CE Directive for waste electrical and electronic equipment
DISPOSE OF PROPERLY
ENVIRONMENT-NOXIOUS MATERIALS
page 7 Drw. N. 5755