page 14
FOR SLIDING GATE SYSTEMS Dip-B N°1=ON
27
Key-switch:
Photocells:
1
DIP-SWITCH-A N° 1:
ON: gate is stopped in opening and reversed
in closing once cleared from obstacle
OFF: gate is not stopped in opening and is
reversed in closing in case of obstacle
Radio Contact
(step by step mode):
Any NO connection to these two terminals
will perform the following:
- Opening only: Dip 2=ON and Dip 5=OFF
- Gate travel reversing by any pulse
Dip 2=OFF and Dip 5=OFF
- Step by step: Open-Stop-Close-Stop
Dip 2=OFF and Dip 5=ON
- No new pulse is accepted in opening.
In Dwell phase and in closing any new
pulse stops and reverses gate travel:
Dip 2=ON and Dip 5=ON
ON: It does not stop and reverse gate travel
in opening
OFF: always stops & reverses in opening
2
ON: step by step with intermediate stop
OFF: gate travel reversed by any radio pulse
5
DIP-SWITCH-A N°2 and N°5:
all of the NC contacts of
the safety accessories
such as the photocells
(receivers) are to be
series connected to
terminals 1 and 2
Accessory
Electrical connections
NO and NC contacts to be connected
to the respective terminals in the keyor button-switches.
All of the possible setting combinations
are described in the instructions sheets
included with the respective control
accessories
NC
NC
1 2
3 4 5 6
FADINI
FADINI
NC
OPEN
CLOSE
STOP
COMMON
RADIO
CONTACT
COMMON
3 7
L1 ON = no obstacle detected, it goes off
in case of obstacle
L4 OFF = no OPENING contact, it goes on
whenever an opening pulse is given
L5 OFF = no CLOSING contact, it goes on
whenever a closing pulse is given
L6 ON = STOP contact closed, it goes
off whenever a stop pulse is given
L7 OFF = no RADIO contact, it goes on
by any radio pulse
Dip-Switch A
1 = ON Photocells stop gate in opening
2 = ON Radio, no reversing in opening
3 = ON Automatic closing
4 = ON Pre-flashing in service
5 = ON Radio step-by-step
6 = ON Traffic lights mode
limit switches connected
ON
OFF
1 2 3 4 5 6 7 8 9 10 11 12
DIP-SWITCH - A
meccanica
FADINI
FOR SLIDING GATE AUTOMATIC SYSTEMS WITH LIMIT SWITCHES:
Dip Switch B N°1= ON
7 = OFF: Blank
8 = OFF: Blank
9 = ON 2
nd
pair photocells in service
10 = ON Flasher off in Dwell time
11 = ON Gate re-closing in Opening and Dwell on photocells engaging
12 = OFF: Blank
Dip-Switch B
1 = ON SLIDING GATE mode
2 = ON Hold-on-switched control mode (deadman control)
3 = ON Traffic lights on "yellow" for 3 seconds
4 = ON DSA control by Photocell transmitters if connected to the dedicated terminals
2nd pair photocells
(fitted inside perimeter):
Dip A No.9=ON and the NC contact connected: The gates
stay stopped as long as the photocells are obstructed.
- In opening cycle: obstacle removed, gates go on opening
- In closing cycle: obstacle removed, gate travel reversed
NOTE: if no 2nd pair photocells are used, it is not necessary
to bridge the contact input, only DIP-SWITCH-A No. 9=OFF
1 2 3 4
ON
OFF
DIP-SWITCH - B
2 3 4
1
ON
OFF
DIP-SWITCH - B
FADINI
Dip-Switch setting and LED indication of functions
ELECTRICAL CONNECTIONS ON SLIDING GATE MODE - Dip Switch B n°1=ON
12 13
24Vac output max load:
n°1 radio receiver
n°3 pairs photocells
27
UNIVERSAL ELECTRONIC CONTROL BOX
SINGLE-PHASE 230V 50/60Hz
DIP-SWITCH-A N° 9:
ON: Photocells 2nd pair in service
OFF: Photocells 2nd pair not installed
9
L0 ON = no obstacle detected, it
goes off in case of obstacle
This pair of photocells stops gate in opening;
once cleared from obstacle, gate goes on
opening, gate travel is reversed in closing
FADINI
FADINI
1
2
3
4
5
6
7
8
9
A
B
STOP
Output for a 24V max 3 W indication lamp
showing the status of the system:
Lamp On = Gate open
Lamp Off = Gate closed
0.5s (fast) flashing = gate closing
1s (normal) flashing = gate opening
Indication lamp
output
24V- max 3W:
COMMON
3 11