Fadini Elpro 13 CEI User Manual

260
182
13
CEI
SINGLE-PHASE
llo
e
c
n
a
ic
r
p
l’a
1
0
280
COVER KNOB CUT OFF SWITCH
F4
630 mA
FUSE
F2
13
5 Amp.
FUSE
CUT OFF
SWITCH
BY COVER KNOB
CEI
F3 F1
FOR SWING GATES – SINGLE-PHASE
5 Amp.
FUSE
FUSE
LAMP
630 mA
FLASHING
230 V SINGLE-PHASE
SUPPLY VOLTAGE
230 V - 25 W max FLASHING LAMP
140
200
TECHNICAL DATA
- Supply Voltage 230 V - 50 Hz
- Voltage Output 230 V - 25 Hz
- Low Voltage Output 24 V - 10 W
- E.M. Power Output 1ú100 W
- Line Fuses 5 A
- Secondary Fuses 1 A - 630 mA
- Command Open - Stop - Close ­Other functions
- Dimensions of the Container 280x200x140 mm
- IP Standards IP 437
Open Contact Relay
+
Approval Mark IMQ - -S-S-10 A - 240 V
- Capacitor 12.5 µF - 400 V
Transformer
- Power 20 VA
- Magnetic Core 1.5 W / Thickness 0.50
- Supply Voltage 0 - 230 V
- Output 0 - 12 - 18 - 24 V
- Working Frequency 50 - 60 Hz
- Insulation 4 Kv x 1’
26 27 28
ON OFF
123456
1233456 78910111213
Fuse 5x20
141516171819 20 21
Fuse 5x20
Fuse 5x20
Fuse 5x20
F5
LEAF DELAY
TIMER
CLOSE
+
0
7
ON TO “0” THE DELAY
IS OUT OF SERVICE
24 V OUTPUT
1° CHANNEL
RADIO CONTROL
PLUG-IN CARD SUPPORT
1 Amp. FUSE:
24 V OUTPUT
TERMINALS 12 - 13
DWELL TIME
MOTOR RUN
+
8
MICROPROCESSOR
9
FADINI
CAPACITORS
TIME OPEN
& CLOSE
+
ON
M2
COMMON
M1
12,5 µF 12,5 µF
16 252423222120191817
COMMON
43211312111098765
123 4 5 6
-PHOTOCELLS 2 INSIDE PHOTOCELLS N.C. contact. If obstructed, they prevent the gates from opening, reverse gate direction during close cycle.
OFF
ELECTRIC MOTORS
SINGLE-PHASE
Max. permitted load:
24 Vac OUTPUT
24 V - 3 W max. INDICATOR
VOLTAGE OUTPUT ELECTRIC LOCK SUPPLY
COMMON
RADIO CONTACT N.O.
STOP SWITCH N.C. CONTACT
CLOSE SWITCH N.O. CONTACT
OPEN SWITCH N.O. CONTACT
COMMON
N.C. CONTACT. PHOTOCELLS
nd PAIR-
2 pairs photocells 1 radio receiver
N. W.: for special applications, ie. to switch on lights
- CCTV etc…, SOLID STATE RELAYS are recom-
78
PEDESTRIAN MODE
ONE PULSE OPENS
ONE GATE LEAF ONLY
mended to be used only.
Standard relays would affect the micro-processor.
N.W.: THIS PANEL IS TESTED TO OPERATE GATES
ONLY THROUGH FADINI ACCESSORIES. NO
GUARANTEE FOR ACCESSORIES OF OTHER MAKE
OR SPECIAL APPLICATIONS.
RADIO CONTACT
ALL OPERATIONS
OPEN, CLOSE & REVERSE
GB
Drwg. No.
2014
AUTOMATIC GATE MANUFACTURERS
8 WAY DIP-SWITCH
Via Mantova, 177/A - 37053 Cerea (Verona) Italy
®
Tel. 0442 330422 r.a. - Fax 0442 331054
s.n.c.
e-mail: info@fadini.net - www.fadini.net
CUT OFF SWITCH BY COVER KNOB
the gate opener
Made in Italy
34
DIP-SWITCH
12 435678
262728
TERMINALS FOR THE
CONNECTION OF THE
PUSH BUTTONS PULIN 3
GB
®
Drwg. No.
2014
ON
B
Should more pairs of photocells be required than the recommended quantity, fit an auxiliary transformer outside the control box.
PULSE TWICE
BOTH GATE LEAFS
CONSECUTIVELY TO OPEN
13
CEI
13
CEI
FEATURES OF THE ELECTRONIC PROGRAMMER FOR SWINGING GATES
All the electrical connections are to be made as per the following instructions and diagrams. Supply the terminals 24-25 with 230V - 50 Hz single phase voltage. The “red LED” switches on and stays on as long as the board is properly supplied. Through the timer No. 9 you can control the running time of the motor in both cycles, OPEN and CLOSE. Set it so that the running time of the motor is longer than the actual travel of the gate: set the timer No. 8 -DWELL- ie. the interval between open and re-closing, so that you can meet the required interval of time. The timer No. 7 -LEAF DELAY in “close” cycle- is to be set as follows: on to “–” (less) the delay is out of service; clockwise on to “+” (more) the delay is operative.
- With the electric motor connected to terminals 19 - 20 - 21: the delay is operative in the “open” cycle, with a factory pre-set time.
- With the electric motor connected to terminals 16 - 17 - 18: the delay is operative in “close” cycle and can be adjusted through the timer No. 7 on to “less” or “more”.
LOGIC OF THE ELECTRONIC PROGRAMMER: When a pulse is given, the flashing light switches on. After three seconds the motors start. During the interval before re-closing, the light stays on. When the gates are fully re-closed, the light keeps on flashing for three more seconds and then switches off automatically. The 3 second interval (pre-flashing) which precedes the actual start of the motors can be eliminated by means of the DIP-SWITCH “B” No.4.
LED No. 1: It switches on when voltage is supplied. LED No. 2: “PHOTOCELLS”. Normally on. It switches off when the photocells are obstructed. LED No. 3: “OPEN”. It switches on when the respective switch is activated. LED No. 4: “CLOSE”. It switches on when the respective switch is activated. LED No. 5: “STOP”. Normally on. It switches off when the respective switch is activated. LED No. 6: “RADIO”. It switches on whenever a pulse is given, either from remote control, keyswitch or push buttons.
DIP-SWITCH N° 1 OFF = PHOTOCELLS. NO STOP IN OPEN CYCLE. REVERSE/CLOSE N° 2 OFF = REMOTE CONTROL. REVERSE N° 3 OFF = NO AUTOMATIC RECLOSING N° 4 OFF = NO PRE-FLASHING N° 5 OFF = REMOTE CONTROL. NO STOP AND HOLD AS LONG
N° 6 OFF = BOTH LEAFS ARE OPERATED
N° 7 OFF = S. R. P. OUT OF SERVICE
N° 8 OFF = LEAF DELAY OPEN CYCLE.
LAMP ON = GATE OPEN LAMP FLASHES SLOWLY = GATE OPENING LAMP FLASHES FAST = GATE CLOSING LAMP OFF = GATE CLOSED
B SETTING IN ELPRO 13 CEI
AS BUTTON DOWN. IT OPENS STRAIGHT AWAY
ONE STARTS BEFORE THE OTHER
N° 1 ON = STOP DURING OPEN CYCLE N° 2 ON = NO REVERSE DURING OPEN CYCLE N° 3 ON = AUTOMATIC RECLOSING N° 4 ON = PRE-FLASHING N° 5 ON = STOP AND HOLD AS LONG AS THE BUTTON IS KEPT DOWN N° 6 ON = PEDESTRIAN. ONE LEAF ONLY
GATES IN CLOSE POSITION
N° 7 ON = S. R. P. IN SERVICE
GATES IN CLOSE POSITION
N° 8 ON = NO LEAF DELAY
BOTH MOTORS START TOGETHER
FEATURES AND TECHNICAL SPECIFICATIONS
“Elpro 13 CEI” represents the latest state of the art technology for control panels. It is extremely versatile and can meet the most various requirements. It is fitted with the “Cut Off Switch” by cover knob. It has the same functions as “Elpro 9” and incorporates additional advantages as follows: Stroke Reversing Pulse, Pedestrian Operating Mode (where one leaf only can be operated allowing people to walk in/out), STOP and HOLD function by keeping the remote control button pressed down. Further improvements can be noted in the “Elpro 13 CEI”:
- Addition of a 1 Amp. fuse to the 24 V circuit as a protection for the accessories (remote control - photocells -etc.) which are connected to the terminals 12 - 13 and for the panel itself in that it can prevent short circuit during installation.
- The pulse to the electric lock is increased to 2 seconds. Releasing is so much easier as the electric lock is released with an anticipation of 100 msec. before the gate starts moving.
- A 24 V - 3 W lamp indicates gate operations (Gate CLOSED = Lamp OFF - Gate in OPEN cycle = Lamp flashes slowly - Gate OPEN = Lamp stays ON without flashing - Gate in CLOSE cycle = Lamp flashes fast).
- It provides a better switching intelligence design to enhance the reliability of the relays.
- The Motor Run Time is independent from the Leaf Delay Time in close cycle (the delay time is automatically added to the duration of the ­opening time).
- The 8 Dip-switches can be arranged into any of the possible patterns to achieve the required operating modes without any risk of interference with one another.
“STROKE REVERSING PULSE” and “S.1A.P.”
Set Dip-switch No. 7 to ON The ”Stroke Reversing Pulse” (S.R.P.) is activated only with the gate in the CLOSE position. The pulse operates the gate in the CLOSE direction first and then immediately reverses into OPEN (This will help the gate lock to release). All the other operations will be performed in the standard way. No danger comes from the Stroke Reversing Pulse. This function remains in service with the panel set to “Pedestrian Mode”. Set Dip-switch No. 6 to ON for “Pedestrian Mode” (S.1A.P.), terminals 3 - 4. Only one leaf is operated when the OPEN button is pressed down. Automatic reclosing. If the OPEN button is pressed twice in a row, both leafs are opened. The S.1A.P. function is activated only when the gate is in the fully CLOSE position. The remote control always operates both gates, terminals 7 - 8.
DIP-SWITCH N° 1 OFF = PHOTOCELLS. NO STOP IN OPEN CYCLE. REVERSE/CLOSE N° 2 OFF = REMOTE CONTROL. REVERSE N° 3 OFF = NO AUTOMATIC RECLOSING N° 4 OFF = NO PRE-FLASHING N° 5 OFF = REMOTE CONTROL. NO STOP AND HOLD AS LONG
N° 6 OFF = BOTH LEAFS ARE OPERATED
N° 7 OFF = S. R. P. OUT OF SERVICE
N° 8 OFF = LEAF DELAY OPEN CYCLE.
B SETTING IN ELPRO 13 CEI
AS BUTTON DOWN. IT OPENS STRAIGHT AWAY
ONE STARTS BEFORE THE OTHER
N° 1 ON = STOP DURING OPEN CYCLE N° 2 ON = NO REVERSE DURING OPEN CYCLE N° 3 ON = AUTOMATIC RECLOSING N° 4 ON = PRE-FLASHING N° 5 ON = STOP AND HOLD AS LONG AS
THE BUTTON IS KEPT DOWN
N° 6 ON = PEDESTRIAN. ONE LEAF ONLY
GATES IN CLOSE POSITION
N° 7 ON = S. R. P. IN SERVICE
GATES IN CLOSE POSITION
N° 8 ON = NO LEAF DELAY
BOTH MOTORS START TOGETHER
1) It is advisable not to expose the control box directly to weather conditions; if mounted outside, a suitable enclosure is recommended to protect it from sunshine and rain.
2) Bridge terminals 1 - 2 if you do not require any photocells.
3) Should two sets of photocells be required, these are to be series connected to terminals 1 - 2, contact normally closed.
4) Bridge terminals 6 - 8 if you do not require any keyswitch or push buttons.
5) Fit the mains to the control box with a high sensitivity, differential, magnetic-thermal switch, 0.03 Amps.
6) OPERATING MODE WITH TWO PAIRS OF PHOTOCELLS, INDEPENDENT FROM EACH OTHER Dip-switch No. 1 set to OFF, connect the pair of photocells that are inside the property to the terminals marked “2 The second pair always stops the gate in open cycle in case of an obstacle. During close cycle the second pair reverses the gate direction.
7) NOTE WELL FAULT FINDING:
- Check supply voltage with a tester: it must be 230 V, single-phase.
- Check the high voltage fuses.
- Check the low voltage fuses.
- Check if the photocell contacts are normally closed.
- Check voltage from the control box to the electric motor(s): power might have dropped.
- The section of the electric cables to the motor(s) must not be less than 1.5 mm
- Connect the other pair to the terminals 1 - 2 This pair performs in the standard pre-set mode, ie: no stop during open cycle, REVERSING GATE DIRECTION DURING CLOSE CYCLE. Terminals to stay linked out should the second pair of photocells not be used, and set the desired operating mode through Dip-switch No. 1. 24 V ~ output. Terminals 12 - 13. It can supply power for 2 pairs of photocells plus 1 radio receiver. Terminal 11 provides a power output for a lamp. 24 V - 3 Wmax. Flashing lamp output. Terminals 22 - 23. Maximun available power 25 Wmax.
2
.
nd
pair”.
The box of ELPRO 13 CEI and its cover are made of weather-proof, shock-resistant plastic material which has a degree of protection equalling IP 437. The cover is fitted with a knob of quick response in case of an emergency by cutting off the voltage supply.
llo
e
c
n
a
ic
r
p
a
l’
13
CEI
SINGLE-PHASE
Loading...