EXT TIME (electric lock and
courtesy light) from 2 to 255s
+
T3
PEDESTRIAN
OPENING TIME
+
from 3 to 30s
T2
DWELL TIME
+
from 5 to 128s
T1
MOTOR RUN TIME
+
from 5 to 128s
RS
RS
16
W
230V COURTESY LIGHT
12V AC RELAY FOR
ELECTRIC LOCK OR
F6=630mA
24V protection
17
COMMON
V
M
MOTOR
CAPACITOR
TRANSFORMER
L1
L10
F5=1A flashing lamp
protection
Voltage cut off switch
and cover locking knob
19
18
U
230V 25W max
FLASHING LAMP
230/400V
F4=630mA
Transformer
protection
F1=8A mains
F2=8A mains
F3=8A mains
2122
20
LIVE
T
400V 50Hz
THREE-PHASE
VOLTAGE SUPPLY
2322
NEUTRAL
LIVE
S
230V 50Hz
SINGLE-PHASE
VOLTAGE SUPPLY
LIVE
LIVE
R
S
NEUTRAL
The electronic control panel Elpro 10 Plus CEI, new generation, is designed to operate sliding gates. Power supply is 230/400V single-phase and three-phase. Built in full
compliance with BT 93/68/CE Low/High Voltage and EMC 93/68/CE Electro-Magnetic Compatibility Regulations. Fitting operations are recommended by a qualified technician
in conformity to the existing safety standards.
The manufacturing company declines any responsability for incorrect handling and application; also, it reserves the right to change or update the control panel any time.
PLEASE NOTE:
- The control panel must be installed in a sheltered, dry place, inside the box provided with it.
- Fit the mains to the control panel with a 0.03A high performance circuit breaker.
- Use 1.5 mm2 section wires for voltage supply, electric motor and flashing lamp.
Maximum recommended distance 50m.
Use 1 mm2 section wires for limit switches, photocells, push-buttons/key-switch and accessories.
- Bridge terminals 1 and 2 if no photocells are required.
- Bridge terminals 3 and 6 if no key- or push-button switches are required.
N.W: To fit extra accessories such as lights, CCTV etc. use only solid state relays to prevent damages to the microprocessor.
1
DIP-SWITCH
2
3
ON
OFF
6
8
4
7
5
In case of failure of the panel:
- Check voltage supply. It must be 230V or 400V 50Hz
- Check fuses
- Check photocells if contacts are normally closed
- Check all NC contacts
- Check that no voltage drop has occurred from the control
panel to the electric motor
Dip-Switch:
1= ON. Photocells. Stop while opening
2= ON. Radio. No reversing while opening
3= ON. Automatic closing
4= ON. Preflashing activated
5= ON. Radio. Step by step. Stop in between
6= ON. Dead Man Control (Dip 4=OFF and Dip 3=OFF)
7= ON. No lamp on during dwell time
8= OFF. No function
Led Status Indication:
L1= 230V 50Hz power supply. Alight
L2= Photocells, if obstructed light goes off
L3= Open. Alight whenever an Open pulse is given
L4= Close. Alight whenever a Close pulse is given
L5= Stop. It goes off on pulsing Stop
L6= Radio. It goes on by pressing a transmitter button
L7= Gate Status; it flashes on gate opening
L8= Limit switch Close; off when gate is closed
L9= Limit switch Open; off when gate is open
L10= It stays on for a time equal to the time set on T4
24V OUTPUT (MAX. LOAD:
2 PAIRS PHOTOCELLS
1 RADIO RECEIVER)
DIP-SWITCH 2 and 5 (NEVER set BOTH of
them to ON at the same time):
ON: Gate is not reversed while opening
OFF: Any pulse reverses the gate
2
ON: Step by step. Stop in between
OFF: Standard operating mode
5
18
17
COMMON
V
U
M
MOTOR
W
CONTACT
7
RADIO
16
DIP-SWITCH 1:
ON: Photocells stop gate while opening,
reverse it on closing once obstacle is
removed
OFF: Photocells do not stop gate while
1
opening, reverse it on closing in
case of an obstacle
Courtesy light:
RS
RS
Flashing lamp:
19
20
230V MAX 25W
Push Button Switch Pulin 3:
3
COMMON
Connect a 12VAC Relay
(
T4 Trimmer Time from
2s to 255s) to operate
a 230V lamp
DIP-SWITCH 4 and 7:
ON: Pre-flashing
OFF: No pre-flashing
4
ON: Lamp is not operating during
Dwell Time. Automatic Mode.
OFF: It flashes during Dwell Time .
7
Automatic Mode.
28
26
27
Electric lock:
RS
RS
Button switch:
4
3
5
6
COMMON
OPEN
STOP
CLOSE
Led to indicate status
of Open - Stop - Close
switches
Set the T4 Trimmer Time
to the lowest value The
electric lock is excited
for 2 seconds
Power supply:
2122
LIVE
S
230V 50Hz SINGLE-
PHASE
2322
NEUTRAL
Limit switch:
8
10
9
LIMIT SWITCH
CLOSE
C
OMMON
230V
2122
LIVE
LIVE
TRS
400V 50Hz THREE-
PHASE
LIMIT SWITCH
OPEN
400V
2322
LIVE
OPERATING MODES
Automatic / Semiautomatic:
Automatic Operation: any pulse opens the gate, the gate stays
open as long as the Dwell time expires as set by T2 trimmer, then
it closes automatically, no pulsing is required.
Semi-automatic Operation: any pulse opens the gate that stays
open. A second pulse to Close is required for the gate to close.
DIP-SWITCH 3
+
-
Dwell Time
T2
from 5 to 128s
Remote Controlled Operations Excluded during
Dwell Time on Automatic Mode:
ON: No reversing on opening
OFF: Travel reversing on any pulsing
2
Time clock:
+
-
Pedestrian Trimmer T3
set on to zero
ON= Automatic Closing
OFF= No Automatic. Semi-automatic
3
closing by pulse
With this setting it is not possible to operate the gate by remote control during the dwell time on automatic
mode. DIP-SWITCH 2=ON, 3=ON and 5=ON
How it works: Set the clock to the required time. On the pre-set time the gate is automatically opened and held open. Any further pulsing (even
by remote control) is not accepted by the system until the time pre-set by the clock has expired. On expiring and after the pre-set dwell time
the gate is closed automatically.
T3 trimmer on to zero, Dip-Switch 3=ON.
DIP-SWITCH No.3=ON Automatic Closing
ON= Automatic Closing
OFF= No Automatic. Semi-automatic
3
closing by pulse
Pedestrian Opening:
-
from 3 to 30s. It can be activated by
any pulse (eg. by remote control)
superior to 2s
3
COMMON
ON= Automatic Closing
OFF= Closing by Pulse
3
Trimmer T3
+
4
OPEN
Hold on switched (Deadman) control:
Open and Close operations are achieved "by holding a
switch on" (no relay self-holding is involved) therefore a
phisical attendance is required to keep the gate opening
or closing until either the button or key is released.
DIP-SWITCH 6
ON= Deadman Control. Dip-switch 4=OFF
and Dip-switch 3=OFF
OFF= Standard Operations
6
ON: Step by step. Stop in between
OFF: Standard Operations
5
43
COMMON
OPEN
NO
COMMON
the gate opener
Made in Italy
®
Drwg. No.
4333
page 5
Page 4
200
182
260 280
110
I-
Prima dell'installazione da parte di personale tecnico qualificato, si consiglia di prendere visione del
Libretto Normative di Sicurezza che la Meccanica Fadini mette a disposizione.
GB -
Please note that installation must be carried out by qualified technicians following Meccanica Fadini's
Safety Norms Manual.
F-
L'installation doit être effectuée par un technicien qualifié suivant le manuel des Normes de Sécurité
de Meccanica Fadini.
D-
Vor der Montage von einem Fachmann, wird es empfohlen die Anleitung zur Sicherheitsnormen, die
Meccanica Fadini zur Verfügung stellt, nachzulesen.
E-
Antes de la instalación por el personal técnico calificado, se recomienda leer detenidamente el Folleto
de la Reglamentación de Seguridad que la empresa Meccanica Fadini pone a su disposición.
NL -
Vòòr installatie, dat door bevoegd technisch personeel moet worden uitgevoerd, wordt het aangeraden
de Handleiding met de Veiligheidsnormen door te lezen die Meccanica Fadini tot beschikking stelt.