Optional
Code 5578
BRAKE
CONTROL
STEP SWITCH
-
5 4 3 2 1
+
630mA
FUSE
POT. 80VA 50/60Hz
MOD. E010F
PRI: 400-230V
SEC: 24V - 1A
COMELIT
Made in Italy
276/25/06/C
400V - 24Vac
80VA TRANSFORMER
230V
VOLTAGE
CHANGE-OVER SWITCH
400V
BRAKE
CONNECTOR
FLASHING LAMP
1A
OPEN
ON
FUSE
LOGIC CARD
OFF
CLOSE MAINS
1A FUSE
24V OUTPUT
TERMINALS 12-13
DWELL
TIME
+
-
5A
FUSES
HIGH VOLTAGE
EARTH
CONNECTION
MOTOR RUN TIME
OPEN/CLOSE
+
-
12 3 45 6 78
NEUTRAL
23
2221
20
19
19
18
COMMON
17
16
15
14
13
12
11
10
96
85
74
3
2
1
Elpro 10
LIVE
N.C. SAFETY
CONTACT
24V OUTPUT max permitted load:
2 pairs photocells
1 radio receiver
24V INDICATOR - 3W max
LIMIT SWITCH. OPEN. N.C.
COMMON
LIMIT SWITCH. CLOSE. N.C.
RADIO CONTACT
N.C. CONTACT. STOP
N.O. CONTACT. CLOSE
N.O. CONTACT. OPEN
COMMON
N.C. CONTACT.
PHOTOCELLS
230V
SINGLE-PHASE
SUPPLY VOLTAGE
230V FLASHING LAMP - 25W max
M
ELECTRIC
SINGLE-PHASE
ELECTRIC LOCK
POWER OUTPUT
F
SLIDING GATES
THREE-PHASE / SINGLE-PHASE
M
230-400V
THREE-PHASE
SUPPLY VOLTAGE
THREE-PHASE
34
MOTOR
ELECTRIC
TIONS
21 22 23
MOTOR
2 PULSES: FULL OPENING
1 PULSE: PEDESTRIAN OPENING
PEDESTRIAN OPERATOR
DIP-SWITCH
ON
262728
TERMINALS FOR THE
CONNECTION OF THE
PUSH BUTTONS PULIN 3
GB
Drwg. No. 3339
ELPRO 10 F
MICRO-PROCESSOR
B
12 345678
CHANNEL
st
24V OUTPUT
1
RADIO CONTROL
PLUG-IN CARD SUPPORT
N.W.: should more pairs of photocells be required than the
recommended quantity, fit an auxiliary transformer outside the
control box.
N.W.:
for special application, ie. to switch on lights - CCTV etc...,
SOLID STATE RELAYS are recommended to be used only. Standard
relays would affect the micro-processor.
N.W.:
THIS PANEL IS TESTED TO OPERATE GATES ONLY THROUGH
FADINI ACCESSORIES, NO GUARANTEE FOR ACCESSORIES OF OTHER
MAKE OR SPECIAL APPLICATIONS.
ELECTRONIC PROGRAMMER
FOR SLIDING GATES. PEDESTRIAN OPENING.
HOLD ON SWITCHED CONTROL AND
ELECTRONIC BRAKE.
37
REVERSE
OPEN, CLOSE &
ALL OPERA
RADIO CONTACT
Elpro 10
F
FUNCTIONS OF THE ELECTRONIC PROGRAMMER FOR SLIDING GATES
All the electrical connections are to be made as per the following instructions and diagrams. Supply the terminals
21-22-23 with 230/400 V / 50 Hz, three-phase voltage. The "red led" No.1 switches on and stays on as long as the
board is properly supplied. Set the timer "MOTOR RUN. OPEN & CLOSE" so that the running time of the motor is longer
than the actual travel of the gate. Set the timer "DWELL" - i.e. the interval between open and re-close- so that you
can meet the required interval of time.
LOGIC OF THE ELECTRONIC PROGRAMMER: when a pulse is given, the flashing light switches on. After three seconds
the motor starts. During the interval before re-closing, the light stays on. When the gate has fully re-closed, the light
keeps on flashing for three more seconds and the switches off automatically. The 3 second interval (pre-flashing)
which precedes the actual start of the motor can be eliminated by means of the DIP-SWITCH B No. 4.
LED No. 1: It switches on when voltage is supplied.
LED No. 2: Photocells. Normally on. It switches off when the photocells are obstructed.
LED No. 3: Open. It switches on when the respective switch is activated.
LED No. 4: Close. It switches on when the respective switch is activated.
LED No. 5: Stop. Normally on. It switches off when the respective switch is activated.
LED No. 6: Radio. It switches on whenever a pulse is given, either through remote control, keyswitch or push buttons.
LED No. 7: Limit switch. Close. It switches off when the gate is fully closed.
LED No. 8: Limit switch. Open. It switches off when the gate is fully open.
DIP-SWITCH
ON
ON
B
1 2345 678
No. 1 ON = PHOTOCELLS. STOP DURING "OPEN" CYCLE
No. 1 OFF = PHOTOCELLS. NO STOP DURING "OPEN" CYCLE. REVERSE ON CLOSING.
No. 2 ON = REMOTE CONTROL. NO REVERSE TRAVEL ON OPENING
No. 2 OFF = REMOTE CONTROL. REVERSE TRAVEL
No. 3 ON = AUTOMATIC RE-CLOSING
No. 3 OFF = NO AUTOMATIC RE-CLOSING
No. 4 ON = PRE-FLASHING
No. 4 OFF = NO PRE-FLASHING
No. 5 ON = REMOTE CONTROL. STEP BY STEP. STOP IN BETWEEN
No. 5 OFF = REMOTE CONTROL. GATE CAN BE REVERSED WHILE TRAVELLING
No. 6 ON = "DEADMAN CONTROL" (HOLD-ON SWITCHED). SET No.3 TO OFF
No. 6 OFF = OUT OF SERVICE. NORMAL OPERATING MODE
"
switch button or key is hold on pressed or turned until
the end of the operation.
OFF
HOLD ON SWITCHED CONTROL": any open or close operations require that the respective
GENERAL DIAGRAM. DIP-switches No. 1 2 3 4 5 6
DIP-SWITCH
ON
B
1 2345 678
ELECTRONIC BRAKE TO FIT
ELPRO 10 F PROGRAMMER
- BRAKE FORCE ADJUSTMENT.
Force can be adjusted by means of a step
switch from one to five steps. (Optional)
GB
ON
OFF
ON
78
full
opening
SETTING FOR PARTIAL PEDESTRIAN OPENING. Dip-switches No. 7 8
A first "OPEN" pulse to terminal No.4 opens the gate to the distance set through
the switchs 7 - 8 as explained below; a second pulse opens the gate full travel.
meccanica
F
FADINI
Drwg. No. 3339
AUTOMATIC GATE MANUFACTURERS
ON
78
1 meter opening
Code 5578
ON
78
1.5 meter opening
-
+
5 4 3 2 1
BRAKE CONNECTOR
Via Mantova 177/A - 37053 Cerea (VR) Italy
Tel. 0442 330422 - Fax 0442 331054
e-mail: info@fadini.net - www.fadini.net
BRAKE CONTROL
STEP SWITCH
+
MORE POWER
2 meter opening
LESS POWER
54 21
ON
78
_
the gate opener
Made in Italy