Instructions manual DGT 61 digital keypad
BRINGING THE KEYPAD APART
Treated
aluminium
front unit
Plastic back casing recess mount
BRINGING THE MAIN PCB APART
This unit is recommended to be installed in a
!
safe and sheltered place
meccanica
FADINI
Item 610
Surface keypad
1
2
4
3
5
7
6
8
A
9
S
T
O
P
B
Item 612
Main Printed Circuit Board
DGT 61
12-24V cc/ca
AB
Z
Y
X
NC
Item 611
Partial recess keypad
1
2
4
3
5
7
6
8
A
9
S
T
O
P
B
Stainless steel
front cover
1
2
4
3
5
7
6
8
A
9
S
TO
P
B
Keypad
ACCESSORIES TO FIT THE KEYPAD, RECESS APPLICATION
1
2
4
3
5
7
6
8
A
9
STOP
B
code 552
code 558
SURFACE APPLICATION OF THE KEYPAD TO A WALL
1
2
4
3
5
7
6
8
A
9
STOP
B
DISPOSITIVO SONORO
NOTE: screws and expanding bolts not supplied by us.
SOUND DEVICE
Treated aluminium
back casing
surface mount
Prit 19
code 560
Pic.4
DGT 61
12-24V cc/ca
AB
Z
NC
Y
X
Pic.1
Sech 15
code 553
LED LIGHTS
1
2
4
3
5
7
6
8
A
9
S
T O
P
F
A
D
B
I N
I
GREEN LED:
 Fixed light: - unit on voltage
- night illumination of the keypad  Flashing light: professionaly advanced timed functions
BLUE LED:
in progress
RED LED: wrong access code or STOP button activated
Pic.2
code 554
code 552
Pic.3
Pic.5
GB
page 7
Directive 2003/108/CE
GB
Disposal of electric and electronic material
DO NOT DISPOSE OF AS
NORMAL WASTE - HARMFUL
FOR THE ENVIRONMENT
the gate opener
made in Italy
Long Beep: a long beep confirms the correct access code sequence
n°1 short beep: is emitted whenever
1
a key button is pressed
n°3 short beeps: the access code
3
sequence is wrong
n°5 short beeps: memory clearing carried out
5
correctly
page 8
1
2
4
3
5
F
7
A
6
D
8
A
I
9
N
STOP
I
B
Pic.6
Page 2
STOP
STOP
FADINI
FADINI
FADINI
GB
Instructions manual DGT 61 digital keypad
meccanica
FADINI
GENERAL DESCRIPTION
DGT 61 is a custom-encoded control accessory designed to open and close any automatic access system. It can be also used to control other external applications. DGT 61 consists of a Key pad (in an anti-corrosion treated aluminium casing, in two options either to be partially recessed or sur face mounted) cable connected (x 4 wires) to the Main PCB; this one is to be installed near the Elpro electronic control box for the electrical connections. The keypad incorporates the button keys, illuminated in blue from the back: nine digits, two outputs A and B and one output for the emergency stop button. The main PCB is fitted with a terminal block where power supply is to be connected (in parallel also to the keypads), with the N.O. contacts of the A and B output relays and with one pure N.C. terminal output of a third relay, providing connections for an emergency stop. A second block of terminals X and Y (and a third one Z for long distance or disturbed signals) receive the encoded signal from the keypads. Programming is simple and immediate by Dip-switches on the main PCB. Each channel can take up to 4 different numerical codes; any one code, through the same channel either A or B, operates the same function. Other professionally advanced functions can be achieved by the two relays (bistable outputs, timed bistable outputs, output delay, etc.), and can be enabled by the Dip-switches on the main PCB. Other external control applications are also made possible (eg. illumination, alarm systems and watering) besides automatic door/gate systems, etc. In these cases, it is recommended that a relay be always fitted between the PCB and the other possible applications.
Red led 1: It flashes during programming phase
Red led 2: It flashes slowly when X Y are properly connected to the keypad
Jumper for 12Vdc power supply: when jumper is fitted, 12Vdc power supply is possible
Automated access A or
other applications
12-24Vac/dc
1st CODE to relay A
2nd CODE to relay A
3rd CODE to relay A
4th CODE to relay A
Main PCB
ON
12345678910
OFF
CNO NOCNCC
A
A
ON
1**
ON
2**
ON
3**
ON
4**
relay NO
relay NCrelay NO
B
B
ON
1**
ON
2**
ON
3**
ON
4**
(*) the connection to the Z terminal is required in
case of weak or
disturbed signal
(*)
max 0.5mm² up to 100m
XYZ
S
= Pure contact for STOP function only: direct to
the relay in case of an emergency
1st CODE to relay B
2nd CODE to relay B
3rd CODE to relay B
4th CODE to relay B
**once encoding/programming phases are completed, all Dip-switches are to be set to OFF
1
23
456
789
STOP
B
A
12-24V
ac/dc
ingresso
automatizzato B o
altre utenze
1 or more keypads DGT 61
Pic.7
DIAGRAM OF A POSSIBLE INSTALLATION WITH TWO KEYPADS AND ONE PCB
DGT 61
Z
Y
X
C
N
AB V 4
-2 2 1
a /c c
c
ON
12345678910
OFF
CNO NOCNCC
AB
24V
ac/dc
0.5mm² up to 100m
main PCB
open
1
456
789
A
XYZ
relay
S
open
33
23
Keypad DGT 61 Keypad DGT 61
STOP
B
XYZ
(*)
12-24V
ac/dc
(*)
XYZ
NCrelay N0relay N0
max 0.5mm²
up to 100m
(*) The connection
to Z terminal is
required in case of
weak or disturbed
stop
13 13
14
XYZ
signal
1
23
12-24V
ac/dc
456
789
A
STOP
B
Controll box series
Elpro - access A
Controll box Elpro 6 -
access B
(*)
3 4 6
common
open
stop
13 14
24Vac/dc
3 4
common
open/stop/close
3
14
Pic.8
page 9 page 10
Instructions manual DGT 61 digital keypad
GB
STORING ONE OR MORE ACCESS CODES ONTO THE RELAY OUTPUT A
1) Carry out the electrical connections to the MAIN PCB (Pic.8).
2) Set
only one of the switches DIP 1 or DIP 2 or DIP 3 or DIP 4 to ON (It is through the first four DIp-switches that different ACCESS CODES can be stored). The red led 1 on the main PCB flashes.
3) Press the ACCESS CODE (from 1 to 6 digits) - press A. The green led goes on followed by a long confirming beep.
4) Set all DIP-switches to OFF. The red led 1 on the PCB goes off.
NOTE: The relay A can take up to 4 different access codes max. Each code is to be stored individually by setting any one of the first 4 DIP-switches to ON.
Diagram
1) 3) 4)
ON
1
Main PCB
2)
1
23
456
789
ACCESS
CODE
A
relay A
STORING ONE OR MORE ACCESS CODES ON O THE RELAY OUTPUT B
1) Carry out the electrical connections to the MAIN PCB (Pic.8).
2) Set
only one of the switches DIP 1 or DIP 2 or DIP 3 or DIP 4 to ON (It is through the first four DIp-switches that different ACCESS CODES can be stored). The red led 1 on the main PCB flashes.
3) Press the ACCESS CODE (from 1 to 6 digits) - press B. The green led goes on followed by a long confirming beep.
4) Set all DIP-switches to OFF. The red led 1 on the PCB goes off.
NOTE: The relay B can take up to 4 different access codes max. Each code is to be stored individually by setting any one of the first 4 DIP-switches to ON.
Diagram
1) 3) 4)
ON
1
Main PCB
2)
1
23
456
789
ACCESS
CODE
relay B
HOW TO OPERATE WITH DGT 61 KEYPAD
Once satisfied that the main PCB is properly connected to the Elpro control box, and the selected ACCESS CODES stored with the required output, to operate with the keypad just press the keys corresponding to the ACCESS CODE, followed by the key corresponding to the required OUTPUT (A or B). The green led goes on followed a long confirming beeping.
If the access code sequence is incorrect: the unit gives out 3
beeping souds and the red led illuminates for 2 seconds. Dial correctly or reprogram the unit.
3
n°3 short beeps
Red led
for 2 seconds
Diagram
1)
1
23
456
789
ACCESS
CODE
2)
A
oppure
A or B output
LON G
B
BEEPING
ENABLING THE STOP BUTTON KEY
Carry out the electrical connections to the keypad, main PCB and the Elpro control box (or to a control relay). Pic. 8. The DGT 61 keypad incorporates also a pure NC contact to get the STOP function. The contacts of the C - NC terminals on the main PCB are opened on pulsing the STOP button in the keypad, and no code is required to be entered.
Diagram
STOP
pure contact
NCC
S
Main PCB
press
red led
for 2 seconds
MEMORY CLEARING
PLEASE NOTE: THIS OPERATION ERASES COMPLETELY ALL THE ACCESS CODES AND ANY ADDITIONAL FUNCTIONS STORED WITH THE RELAY
!
INVOLVED IN THIS PROCESS.
1) Set the Dip-sw. 10 to ON. The red led 1 flashes.
2) Press the key 9 9 9 (three times).
3) Press button A or B to erase the encoding and the functions from output A or B
4) Set all the DIP-switches to OFF.
5 short beeps confirm the operation while the green led keeps flashing as long as beeping can be heard.
Diagram
1)
ON
10
Main
PCB
2)
9 9 9
keypad
3)
A
or
B
A or B output
4)
ALL DIP-SW.
TO OFF
10
OFF
main PCB
n°5 Beeps
B
5
meccanica
FADINI
ALL DIP-SW.
TO OFF
1
OFF
Main PCB
ALL DIP-SW.
TO OFF
1
OFF
Main PCB
green led
for 1 second
green led
Page 3
GB
STOP
FADINI
Connect the main PCB to the control box (Pic. 8) or to the external control relay, then store an access code with required outputs. Different functions can be achieved by one or both of the outputs, but different access codes to one relay carry out the same function. NOTE WELL: functions are reset in case of a power failure, even if instantaneous.
OUTPUT DELAY
The pulse is delayed (for a number of minutes) after pressing the access code.
Programming:
1) Set DIP-sw. 5 to ON. The red led 1 on the PCB flashes.
2) Press the number of minutes corresponding to the activation delay as required (max.1439 minutes).
3) Press output A or B through which the required function is activated.
4) Set all the DIP-switches to OFF Confirmation of the operation: long beep and green led alight for 2 sec.
Using the function:
Press the access code followed by A or B as programmed. The green led goes on for 1 sec. followed by an activation beep. The blue led starts flashing and indicates that the function has been activated.
TIMED WITH 2 PULSES
A pulse is given after the access code has been pressed and another one is given after a set time (minutes)
Programming:
1) Set DIP-sw. 6 to ON. The red led 1 on the PCB flashes.
2) Press the number of minutes for the time required after the first pulse (max. 1439 minutes).
3) Press either A or B output by which the function is to be activated.
4) Set all the DIP-switches to OFF. Confirmation of the operation: long beep and green led alight for 2 sec.
Using the function:
Press the access code followed by A or B as programmed. The green led goes on for 1 sec. followed by an activation beep. The blue led starts flashing and indicates that the function has been activated.
BISTABLE
Each pulse by the access code energizes or de-energizes the output relay.
Programming:
1) Set DIP-sw. 7 to ON. The red led 1 on the PCB flashes.
2) Press only the button key No. 7.
3) Press either A or B output by which the required function is to be actived.
4) Set all the DIP-switches to OFF Confirmation of the operation: long beep and green led alight for 2 sec.
Using the function:
Press the access code followed by A or B as programmed. The green led goes on for 1 sec. followed by an activation beeping.
TIMED DELAY WITH 2 PULSES
Each pulse by the access code delays (for a number of minutes) the energizing of the timed relay.
Programming:
1) Set DIP-sw. 8 to ON. The red led 1 flashes.
2) Press the number of minutes for the delay with time 1 (max 1439 minutes)
3) Press either A or B output by which the required function is to be activated.
4) Press the numer of minutes for time 2 (max. 1439 minutes).
5) Press ether A or B as set in step 3).
6) Set all the DIP-switches to OFF. Confirmation of the operation: long beep and green led alight for 2 sec.
Using the function:
Press the access code followed by A or B as programmed. The green led goes on for 1 sec. followed by an activation beep. The blue led starts flashing and indicates that the function has been activated.
Instructions manual DGT 61 digital keypad
ADDITIONAL FUNCTIONS: can be achieved by the A and B outputs through one or more access codes
pulse
output
pulse
output
pulse
output
pulse
output
Time
Time 1
Time
Time 2
Diagram
1)
ON
5
main PCB
In order to RESET (the function is cancelled) press the following sequence: A or B - access code - A or B
The green led goes on for 1 sec. followed by a confirmation beep, while the blue led stays illuminated.
Diagram
1)
ON
6
main PCB
In order to RESET (the function is cancelled) press the following sequence: A or B - access code - A or B
The green led goes on for 1 sec. followed by a confirmation beep, while the blue led stays illuminated.
Diagram
1)
ON
7
main PCB
Diagram
1)
ON
8
main PCB
In order to RESET (the function is cancelled) press the following sequence: A or B - access code - A or B
The green led goes on for 1 sec. followed by a confirmation beep, while the blue led stays illuminated.
2) 3)
1
456
789
time in minutes
(max 1439 = 24h)
2) 3)
1
456
789
time in minutes
(max 1439 = 24h)
2) 3)
7
press key 7
2) 3)
time 1 in
minutes
(max 1439)
keypad
23
23
A
or
keypad keypad
B
A
output
A
or
output
A
or
output
4)
time 2 in
minutes
(max 1439)
or
B
B
B
page 11
meccanica
FADINI
4)
ALL DIP-SW.
TO OFF
5
OFF
main PCB
ALL DIP-SW.
4) TO OFF
6
OFF
main PCB
ALL DIP-SW.
4) TO OFF
7
OFF
main PCB
5)
A
6)
ALL DIP-SW.
TO OFF
OFF
B
or
output
DGT 61
AB
4V
-2 2 1
a /c c
c
91
Main PCB
B
Z
Y
X
C
N
meccanica
FADINI
ALL DIP-SW.
4)
TO OFF
9
OFF
main PCB
ALL DIP-SW.
3)
TO OFF
main
73
5
PCB
Pic.9
the gate opener
made in Italy
OFF
Instructions manual DGT 61 digital keypad
GB
ADDITIONAL FUNCTIONS: can be achieved by the A and B outputs through one or more access codes
TIMED BISTABLE
The relay is energized and remain energized for the time as set (in minutes).
Programming:
1) Set DIP-sw. 9 to ON. The red led 1 on the PCB flashes.
2) Press the number of minutes corresponding to the activation time as required (max. 1439 minutes).
3) Press output A or B as required for the function to be activated.
4) Set all the DIP-switches to OFF. Confirmation of the operation: long beep and green led alight for 2 sec.
Using the function:
Press the access code followed by A or B as programmed. The green led goes on for 1 sec. followed by an activation beep. The blue led starts flashing and indicates that the function has been activated.
REMOVING THE ADDITIONAL FUNCTIONS
Steps to cancel the additional functions from the single relay and set the DGT 61 unit back to normal functioning.
1) Set DIP-sw. 5 to ON. The red led 1 on the PCB flashes.
2) Press A (or B) - access code - press A (or B).
3) Set all the DIP-switches to OFF. Confirmation of the operation: long beep and green led alight for 2 sec.
OVERALL DIMENSIONS
Ø56
29 25
54
Recess mount keypad
TECHNICAL DATA
Power supply 2x0.5mm² Connections to the keypad Keypad absorption
or
B
8
Stand-by relay absorption Energized relay absorption Working temperature N.O. channels N.C. channels Communication distance Output contacts kaypad protection standards PCB protection standards
The manufacturer reser ves the right to change this manual without prior notice, and is not liable for incorrect applications or damages to persons and properties.
pulse
output
1
23
456
789
AB
Keypad
12-24Vdc/ac 4 x 0.5mm² 15 mA 4 mA 27 mA
-20° +80°C 2 1 max 100 m 1A-125V-60VA IP 54 IP 53
Time
72
Manufacturing company:
The model:
DGT 61 is a digital keypad designed to be sold and installed into a comprehensive "Automatic System", including the original accessories and components as recommended by the Manufacturing Company. The installer must issue the Installer's Declaration of Conformity and carry out all the tests required to comply with the existing regulations. The manufacturing company is not liable for any incorrect use of its product. The product conforms with the following norms as specified below:
- Low Voltage Directive
- Electro-magnetic Compatibility Directive
GB
Diagram
1)
ON
main PCB
In order to RESET (the function is cancelled) press the following sequence: A or B - access code - A or B
The green led goes on for 1 sec. followed by a confirmation beep, while the blue led stays illuminated.
Diagram
1)
ON
5
main
PCB
LONG BEEP
74
2) 3)
9
456
789
time in minutes
(max 1439 = 24h)
2)
A
or
output access
gree led
for 2 seconds
40
Surface mount
keypad
1
B
23
1
456
789
code
23
A
or
output
A
27
DECLARATION OF CONFORMITY
of the manufacturer
meccanica
FADINI
DECLARES UNDER ITS OWN RESPONSIBILITY THAT:
Via Mantova 177/A - C.P. 126 - 37053 Cerea (VR) Italy Tel. +39 0442 330422 - Fax +39 0442 331054 e-mail: info@fadini.net - www.fadini.net
DGT 61
2006/95 CE 2004/108/CE and 92/31 CEE
Meccanica Fadini s.n.c.
Direttore Responsabile
20 - 04- 11
Date:
The responsible manager
page 12