ENGLISH
Instructions Manual
Digital keypad
GB
Instructions manual DGT 61 digital keypad
BRINGING THE KEYPAD APART
Treated
aluminium
front unit
Plastic back casing
recess mount
BRINGING THE MAIN PCB APART
This unit is recommended to be installed in a
!
safe and sheltered place
meccanica
FADINI
Item 610
Surface keypad
1
2
4
3
5
7
6
8
A
9
S
T
O
P
B
Item 612
Main Printed Circuit Board
DGT 61
12-24V
cc/ca
AB
Z
Y
X
NC
Item 611
Partial recess keypad
1
2
4
3
5
7
6
8
A
9
S
T
O
P
B
Stainless steel
front cover
1
2
4
3
5
7
6
8
A
9
S
TO
P
B
Keypad
ACCESSORIES TO FIT THE KEYPAD, RECESS APPLICATION
1
2
4
3
5
7
6
8
A
9
STOP
B
code 552
code 558
SURFACE APPLICATION OF THE KEYPAD TO A WALL
1
2
4
3
5
7
6
8
A
9
STOP
B
DISPOSITIVO SONORO
NOTE: screws and expanding bolts not supplied by us.
SOUND DEVICE
Treated aluminium
back casing
surface mount
Prit 19
code 560
Pic.4
DGT 61
12-24V
cc/ca
AB
Z
NC
Y
X
Pic.1
Sech 15
code 553
LED LIGHTS
1
2
4
3
5
7
6
8
A
9
S
T
O
P
F
A
D
B
I
N
I
GREEN LED:
access code OK
Fixed light: - unit on voltage
- night illumination of the keypad
Flashing light: professionaly advanced timed functions
BLUE LED:
in progress
RED LED: wrong access code
or STOP button activated
Pic.2
code 554
code 552
Pic.3
Pic.5
GB
page 7
Directive 2003/108/CE
GB
Disposal of electric and
electronic material
DO NOT DISPOSE OF AS
NORMAL WASTE - HARMFUL
FOR THE ENVIRONMENT
the gate opener
made in Italy
Long Beep: a long beep confirms the
correct access code sequence
n°1 short beep: is emitted whenever
1
a key button is pressed
n°3 short beeps: the access code
3
sequence is wrong
n°5 short beeps: memory clearing carried out
5
correctly
page 8
1
2
4
3
5
F
7
A
6
D
8
A
I
9
N
STOP
I
B
Pic.6

GB
Instructions manual DGT 61 digital keypad
meccanica
FADINI
GENERAL DESCRIPTION
DGT 61 is a custom-encoded control accessory designed to open and close any automatic access system. It can be also used to control other external
applications. DGT 61 consists of a Key pad (in an anti-corrosion treated aluminium casing, in two options either to be partially recessed or sur face mounted)
cable connected (x 4 wires) to the Main PCB; this one is to be installed near the Elpro electronic control box for the electrical connections. The keypad
incorporates the button keys, illuminated in blue from the back: nine digits, two outputs A and B and one output for the emergency stop button. The main PCB
is fitted with a terminal block where power supply is to be connected (in parallel also to the keypads), with the N.O. contacts of the A and B output relays
and with one pure N.C. terminal output of a third relay, providing connections for an emergency stop. A second block of terminals X and Y (and a third
one Z for long distance or disturbed signals) receive the encoded signal from the keypads. Programming is simple and immediate by Dip-switches on
the main PCB. Each channel can take up to 4 different numerical codes; any one code, through the same channel either A or B, operates the same
function. Other professionally advanced functions can be achieved by the two relays (bistable outputs, timed bistable outputs, output delay, etc.), and
can be enabled by the Dip-switches on the main PCB. Other external control applications are also made possible (eg. illumination, alarm systems and
watering) besides automatic door/gate systems, etc.
In these cases, it is recommended that a relay be always fitted between the PCB and the other possible applications.
Red led 1:
It flashes during
programming phase
Red led 2: It flashes slowly
when X Y are properly connected
to the keypad
Jumper for 12Vdc power supply:
when jumper is fitted, 12Vdc power
supply is possible
Automated
access A or
other applications
12-24Vac/dc
1st CODE
to relay A
2nd CODE
to relay A
3rd CODE
to relay A
4th CODE
to relay A
Main PCB
ON
12345678910
OFF
CNO NOCNCC
A
A
ON
1**
ON
2**
ON
3**
ON
4**
relay NO
relay NCrelay NO
B
B
ON
1**
ON
2**
ON
3**
ON
4**
(*) the connection to the
Z terminal is required in
case of weak or
disturbed signal
(*)
max 0.5mm² up to 100m
XYZ
S
= Pure contact for STOP function only: direct to
the relay in case of an emergency
1st CODE
to relay B
2nd CODE
to relay B
3rd CODE
to relay B
4th CODE
to relay B
**once encoding/programming phases are completed, all Dip-switches are to be set to OFF
1
23
456
789
STOP
B
A
12-24V
ac/dc
ingresso
automatizzato B o
altre utenze
1 or more
keypads DGT 61
Pic.7
DIAGRAM OF A POSSIBLE INSTALLATION WITH TWO KEYPADS AND ONE PCB
DGT 61
Z
Y
X
C
N
AB
V
4
-2
2
1
a
/c
c
c
ON
12345678910
OFF
CNO NOCNCC
AB
24V
ac/dc
0.5mm² up to 100m
main PCB
open
1
456
789
A
XYZ
relay
S
open
33
23
Keypad DGT 61 Keypad DGT 61
STOP
B
XYZ
(*)
12-24V
ac/dc
(*)
XYZ
NCrelay N0relay N0
max 0.5mm²
up to 100m
(*) The connection
to Z terminal is
required in case of
weak or disturbed
stop
13 13
14
XYZ
signal
1
23
12-24V
ac/dc
456
789
A
STOP
B
Controll box series
Elpro - access A
Controll box Elpro 6 -
access B
(*)
3 4 6
common
open
stop
13 14
24Vac/dc
3 4
common
open/stop/close
3
14
Pic.8
page 9 page 10
Instructions manual DGT 61 digital keypad
GB
STORING ONE OR MORE ACCESS CODES ONTO THE RELAY OUTPUT A
1) Carry out the electrical connections to the MAIN PCB (Pic.8).
2) Set
only one of the switches DIP 1 or DIP 2 or DIP 3 or DIP 4 to ON (It is through
the first four DIp-switches that different ACCESS CODES can be stored).
The red led 1 on the main PCB flashes.
3) Press the ACCESS CODE (from 1 to 6 digits) - press A.
The green led goes on followed by a long confirming beep.
4) Set all DIP-switches to OFF. The red led 1 on the PCB goes off.
NOTE: The relay A can take up to 4 different access codes max. Each code
is to be stored individually by setting any one of the first 4 DIP-switches to ON.
Diagram
1) 3) 4)
ON
1
Main PCB
2)
1
23
456
789
ACCESS
CODE
A
relay A
STORING ONE OR MORE ACCESS CODES ON O THE RELAY OUTPUT B
1) Carry out the electrical connections to the MAIN PCB (Pic.8).
2) Set
only one of the switches DIP 1 or DIP 2 or DIP 3 or DIP 4 to ON (It is through
the first four DIp-switches that different ACCESS CODES can be stored).
The red led 1 on the main PCB flashes.
3) Press the ACCESS CODE (from 1 to 6 digits) - press B.
The green led goes on followed by a long confirming beep.
4) Set all DIP-switches to OFF. The red led 1 on the PCB goes off.
NOTE: The relay B can take up to 4 different access codes max. Each code
is to be stored individually by setting any one of the first 4 DIP-switches to ON.
Diagram
1) 3) 4)
ON
1
Main PCB
2)
1
23
456
789
ACCESS
CODE
relay B
HOW TO OPERATE WITH DGT 61 KEYPAD
Once satisfied that the main PCB is properly connected to the Elpro control
box, and the selected ACCESS CODES stored with the required output, to operate
with the keypad just press the keys corresponding to the ACCESS CODE, followed
by the key corresponding to the required OUTPUT (A or B).
The green led goes on followed a long confirming beeping.
If the access code sequence is
incorrect: the unit gives out 3
beeping souds and the red led
illuminates for 2 seconds.
Dial correctly or reprogram the unit.
3
n°3 short beeps
Red led
for 2 seconds
Diagram
1)
1
23
456
789
ACCESS
CODE
2)
A
oppure
A or B output
LON G
B
BEEPING
ENABLING THE STOP BUTTON KEY
Carry out the electrical connections to the keypad, main PCB and the Elpro
control box (or to a control relay). Pic. 8.
The DGT 61 keypad incorporates also a pure NC contact to get the STOP
function. The contacts of the C - NC terminals on the main PCB are opened
on pulsing the STOP button in the keypad, and no code is required to be
entered.
Diagram
STOP
pure contact
NCC
S
Main PCB
press
red led
for 2 seconds
MEMORY CLEARING
PLEASE NOTE: THIS OPERATION ERASES COMPLETELY ALL THE ACCESS CODES AND ANY ADDITIONAL FUNCTIONS STORED WITH THE RELAY
!
INVOLVED IN THIS PROCESS.
1) Set the Dip-sw. 10 to ON. The red led 1
flashes.
2) Press the key 9 9 9 (three times).
3) Press button A or B to erase the encoding
and the functions from output A or B
4) Set all the DIP-switches to OFF.
5 short beeps confirm the operation
while the green led keeps flashing as
long as beeping can be heard.
Diagram
1)
ON
10
Main
PCB
2)
9 9 9
keypad
3)
A
or
B
A or B output
4)
ALL DIP-SW.
TO OFF
10
OFF
main PCB
n°5 Beeps
B
5
meccanica
FADINI
ALL DIP-SW.
TO OFF
1
OFF
Main PCB
ALL DIP-SW.
TO OFF
1
OFF
Main PCB
green led
for 1 second
green led

GB
Connect the main PCB to the control box (Pic. 8) or to the external control relay, then store an access code with required outputs.
Different functions can be achieved by one or both of the outputs, but different access codes to one relay carry out the same function.
NOTE WELL: functions are reset in case of a power failure, even if instantaneous.
OUTPUT DELAY
The pulse is delayed (for a number
of minutes) after pressing the
access code.
Programming:
1) Set DIP-sw. 5 to ON. The red led 1 on the PCB flashes.
2) Press the number of minutes corresponding to the activation delay as
required (max.1439 minutes).
3) Press output A or B through which the required function is activated.
4) Set all the DIP-switches to OFF
Confirmation of the operation: long beep and green led alight for 2 sec.
Using the function:
Press the access code followed by A or B as programmed. The green led
goes on for 1 sec. followed by an activation beep.
The blue led starts flashing and indicates that the function has been activated.
TIMED WITH 2 PULSES
A pulse is given after the access code
has been pressed and another one
is given after a set time (minutes)
Programming:
1) Set DIP-sw. 6 to ON. The red led 1 on the PCB flashes.
2) Press the number of minutes for the time required after the first pulse
(max. 1439 minutes).
3) Press either A or B output by which the function is to be activated.
4) Set all the DIP-switches to OFF.
Confirmation of the operation: long beep and green led alight for 2 sec.
Using the function:
Press the access code followed by A or B as programmed. The green led
goes on for 1 sec. followed by an activation beep.
The blue led starts flashing and indicates that the function has been activated.
BISTABLE
Each pulse by the access code
energizes or de-energizes the
output relay.
Programming:
1) Set DIP-sw. 7 to ON. The red led 1 on the PCB flashes.
2) Press only the button key No. 7.
3) Press either A or B output by which the required function is to be actived.
4) Set all the DIP-switches to OFF
Confirmation of the operation: long beep and green led alight for 2 sec.
Using the function:
Press the access code followed by A or B as programmed. The green led
goes on for 1 sec. followed by an activation beeping.
TIMED DELAY
WITH 2 PULSES
Each pulse by the access code
delays (for a number of minutes)
the energizing of the timed relay.
Programming:
1) Set DIP-sw. 8 to ON. The red led 1 flashes.
2) Press the number of minutes for the delay with time 1 (max 1439 minutes)
3) Press either A or B output by which the required function is to be activated.
4) Press the numer of minutes for time 2 (max. 1439 minutes).
5) Press ether A or B as set in step 3).
6) Set all the DIP-switches to OFF.
Confirmation of the operation: long beep and green led alight for 2 sec.
Using the function:
Press the access code followed by A or B as programmed. The green led
goes on for 1 sec. followed by an activation beep.
The blue led starts flashing and indicates that the function has been activated.
Instructions manual DGT 61 digital keypad
ADDITIONAL FUNCTIONS: can be achieved by the A and B outputs through one or more access codes
pulse
output
pulse
output
pulse
output
pulse
output
Time
Time 1
Time
Time 2
Diagram
1)
ON
5
main PCB
In order to RESET (the function is cancelled) press the following sequence:
A or B - access code - A or B
The green led goes on for 1 sec. followed by a confirmation beep, while
the blue led stays illuminated.
Diagram
1)
ON
6
main PCB
In order to RESET (the function is cancelled) press the following sequence:
A or B - access code - A or B
The green led goes on for 1 sec. followed by a confirmation beep, while
the blue led stays illuminated.
Diagram
1)
ON
7
main PCB
Diagram
1)
ON
8
main PCB
In order to RESET (the function is cancelled) press the following sequence:
A or B - access code - A or B
The green led goes on for 1 sec. followed by a confirmation beep, while
the blue led stays illuminated.
2) 3)
1
456
789
time in minutes
(max 1439 = 24h)
2) 3)
1
456
789
time in minutes
(max 1439 = 24h)
2) 3)
7
press key 7
2) 3)
time 1 in
minutes
(max 1439)
keypad
23
23
A
or
keypad keypad
B
A
output
A
or
output
A
or
output
4)
time 2 in
minutes
(max 1439)
or
B
B
B
page 11
meccanica
FADINI
4)
ALL DIP-SW.
TO OFF
5
OFF
main PCB
ALL DIP-SW.
4)
TO OFF
6
OFF
main PCB
ALL DIP-SW.
4)
TO OFF
7
OFF
main PCB
5)
A
6)
ALL DIP-SW.
TO OFF
OFF
B
or
output
DGT 61
AB
4V
-2
2
1
a
/c
c
c
91
Main
PCB
B
Z
Y
X
C
N
meccanica
FADINI
ALL DIP-SW.
4)
TO OFF
9
OFF
main PCB
ALL DIP-SW.
3)
TO OFF
main
73
5
PCB
Pic.9
the gate opener
made in Italy
OFF
Instructions manual DGT 61 digital keypad
GB
ADDITIONAL FUNCTIONS: can be achieved by the A and B outputs through one or more access codes
TIMED BISTABLE
The relay is energized and remain
energized for the time as set
(in minutes).
Programming:
1) Set DIP-sw. 9 to ON. The red led 1 on the PCB flashes.
2) Press the number of minutes corresponding to the activation time as
required (max. 1439 minutes).
3) Press output A or B as required for the function to be activated.
4) Set all the DIP-switches to OFF.
Confirmation of the operation: long beep and green led alight for 2 sec.
Using the function:
Press the access code followed by A or B as programmed. The green led
goes on for 1 sec. followed by an activation beep.
The blue led starts flashing and indicates that the function has been activated.
REMOVING THE ADDITIONAL FUNCTIONS
Steps to cancel the additional functions from the single relay and set the
DGT 61 unit back to normal functioning.
1) Set DIP-sw. 5 to ON. The red led 1 on the PCB flashes.
2) Press A (or B) - access code - press A (or B).
3) Set all the DIP-switches to OFF.
Confirmation of the operation: long beep and green led alight for 2 sec.
OVERALL DIMENSIONS
Ø56
29 25
54
Recess mount keypad
TECHNICAL DATA
Power supply 2x0.5mm²
Connections to the keypad
Keypad absorption
or
B
8
Stand-by relay absorption
Energized relay absorption
Working temperature
N.O. channels
N.C. channels
Communication distance
Output contacts
kaypad protection standards
PCB protection standards
The manufacturer reser ves the right to change this manual
without prior notice, and is not liable for incorrect applications
or damages to persons and properties.
pulse
output
1
23
456
789
AB
Keypad
12-24Vdc/ac
4 x 0.5mm²
15 mA
4 mA
27 mA
-20° +80°C
2
1
max 100 m
1A-125V-60VA
IP 54
IP 53
Time
72
Manufacturing company:
The model:
DGT 61 is a digital keypad designed to be sold and installed into a comprehensive "Automatic System",
including the original accessories and components as recommended by the Manufacturing Company.
The installer must issue the Installer's Declaration of Conformity and carry out all the tests required to
comply with the existing regulations.
The manufacturing company is not liable for any incorrect use of its product.
The product conforms with the following norms as specified below:
- Low Voltage Directive
- Electro-magnetic Compatibility Directive
GB
Diagram
1)
ON
main PCB
In order to RESET (the function is cancelled) press the following sequence:
A or B - access code - A or B
The green led goes on for 1 sec. followed by a confirmation beep, while
the blue led stays illuminated.
Diagram
1)
ON
5
main
PCB
LONG BEEP
74
2) 3)
9
456
789
time in minutes
(max 1439 = 24h)
2)
A
or
output access
gree led
for 2 seconds
40
Surface mount
keypad
1
B
23
1
456
789
code
23
A
or
output
A
27
DECLARATION OF CONFORMITY
of the manufacturer
meccanica
FADINI
DECLARES UNDER ITS OWN RESPONSIBILITY THAT:
Via Mantova 177/A - C.P. 126 - 37053 Cerea (VR) Italy
Tel. +39 0442 330422 - Fax +39 0442 331054
e-mail: info@fadini.net - www.fadini.net
DGT 61
2006/95 CE
2004/108/CE and 92/31 CEE
Meccanica Fadini s.n.c.
Direttore Responsabile
20 - 04- 11
Date:
The responsible manager
page 12