FAAC E850S Instructions Manual

Page 1
Kit E850S
Translation of the original instructions
Page 2
© Copyright FAAC S.p.A. dal 2017. Tutti i diritti riservati. Nessuna parte di questo manuale può essere riprodotta, archiviata, distribuita a terzi
Tutti i nomi e i marchi citati sono di proprietà dei rispettivi fabbricanti. I clienti possono effettuare copie per esclusivo utilizzo proprio. Questo manuale è stato pubblicato nel 2017.
© Copyright FAAC S.p.A. from 2017. All rights reserved. No part of this manual may be reproduced, archived, distributed to third parties nor
copied in any other way, in any format and with any means, be it electronic, mechanical or by photocopying, without prior written authorisation by FAAC S.p.A.
All names and trademarks mentioned are the property of their respective manu­facturers.
Customers may make copies exclusively for their own use. This manual was published in 2017.
© Copyright FAAC S.p.A. depuis 2017. Tous droits réservés. Aucune partie de ce manuel ne peut être reproduite, archivée ou distribuée à des tiers
ni copiée, sous tout format et avec tout moyen, qu’il soit électronique, mécanique ou par photocopie, sans le consentement écrit préalable de FAAC S.p.A.
Tous les noms et les marques cités sont la propriété de leurs fabricants respectifs. Les clients peuvent faire des copies pour leur usage exclusif. Ce manuel a été publié en 2017.
FAAC S.p.A. Soc. Unipersonale Via Calari, 10 - 40069 Zola Predosa BOLOGNA - ITALY Tel. +39 051 61724 - Fax +39 051 758518 www.faac.it - www.faacgroup.com
© Copyright FAAC S.p.A. ab dem 2017. Alle Rechte vorbehalten. Kein Teil dieses Handbuchs darf reproduziert, gespeichert, an Dritte weitergegeben
oder sonst auf eine beliebige Art in einem beliebigen Format und mit beliebigen Mitteln kopiert werden, weder mit elektronischen, noch mechanischen oder durch Fotokopieren, ohne die Genehmigung von FAAC S.p.A.
Alle erwähnten Namen und Marken sind Eigentum der jeweiligen Hersteller. Die Kunden dürfen nur für den Eigengebrauch Kopien anfertigen. Dieses Handbuch wurde 2017 veröffentlicht.
© Copyright FAAC S.p.A. del 2017. Todos los derechos están reservados. No puede reproducirse, archivarse, distribuirse a terceros ni copiarse de ningún modo,
ninguna parte de este manual, con medios mecánicos o mediante fotocopia, sin el permiso previo por escrito de FAAC S.p.A.
Todos los nombre y las marcas citadas son de propiedad de los respectivos fabricantes. Los clientes pueden realizar copias para su uso exclusivo. Este manual se ha publicado en 2017.
© Copyright FAAC S.p.A. van 2017. Alle rechten voorbehouden. Niets uit deze handleiding mag gereproduceerd, gearchiveerd, aan derden openbaar
gemaakt of op andere wijze gekopieerd worden, in om het even welke vorm en met geen enkel middel, noch elektronisch, mechanisch of via fotokopiëren, zonder schrfitelijke toestemming vooraf van FAAC S.p.A.
Alle vermelde namen en merken zijn eigendom van de respectievelijke fabrikanten. De klanten mogen kopieën maken die enkel voor eigen gebruik bestemd zijn. Dez handleiding werd in 2017 gepubliceerd.
Page 3
CONTENTS
1. INTRODUCTION TO THE INSTRUCTION MANUAL ........... 4
1.1 Meaning of the symbols used ................................... 4
1.2 Tools required ..................................................... 4
EU DECLARATION OF CONFORMITY
The Manufacturer
Company name: FAAC S.p.A. Soc. Unipersonale
2. KIT E850S ............................................................ 5
2.1 Intended use ...................................................... 5
2.2 Unauthorised use ................................................. 5
2.3 Technical characteristics ......................................... 5
2.4 Component identification ....................................... 5
3. PRELIMINARY OPERATIONS ..................................... 7
3.1 Removing the cover .............................................. 7
3.2 Disconnecting the electronic board E850 ...................... 7
3.3 Removing the original frame .................................... 8
3.4 Disconnect the limit switches ................................... 8
4. INSTALLATION ..................................................... 9
4.1 Connecting the new limit switch cable ........................ 9
4.2 Connecting the new electric motor cable ..................... 9
4.3 Installing the new frame ........................................10
4.4 Removing the plastic covers....................................10
4.5 Connections to the board E850S ...............................11
5. STARTUP.......................................................... 14
5.1 Manual operation................................................14
5.2 Limit switch adjustment ........................................15
5.3 Programming ....................................................17
Address: Via Calari, 10 - 40069 Zola Predosa BOLOGNA - ITALY
hereby declares on his sole responsibility that the following products:
Description: The control board
Model: E850S
comply with the following applicable EU legislations:
2014/35/EU 2014/30/EU 2011/65/EU
Furthermore, the following harmonised standards have been applied:
EN 60335-1:2012 + A11:2014 EN61000-6-2:2005 EN61000-6-3:2007 + A1:2011
Bologna, Italy 20-03-2017 CEO
ENGLISH
6. PUTTING INTO SERVICE ........................................ 18
6.1 Final checks ......................................................18
7. DIAGNOSTICS .................................................... 18
7.1 LEDs check .......................................................18
7.2 Status of the automation .......................................18
Translation of the original instructions
Kit E850S 3 532181 - Rev.A
Page 4
1. INTRODUCTION TO THE INSTRUCTION MANUAL
1.1 MEANING OF THE SYMBOLS USED
1 Symbols: notes and warnings on the instructions
WARNING ELECTRIC SHOCK HAZARD - The procedure or step described must be carried out following the instructions provided and according to the
F
applicable safety regulations WARNING, PERSONAL INJURY HAZARD OR RISK OF DAMAGE TO COMPO
NENTS - The procedure or step described must be carried out following the
!
instructions provided and according to the applicable safety regulations. WARNING - Details and specifications that must be complied with in order to
ensure that the system operates correctly.
FIGURE E.g.: 1-3 see Figure 1 - detail 3.
TABLE E.g.: 1 see Table 1.
§
CHAPTER/SECTION E.g.: §1.1 see section 1.1.
ENGLISH
Automatic operation - automation locked
Manual operation - automation unlocked
2 Symbols: safety signs and symbols (EN ISO 7010)
GENERIC HAZARD Personal injury hazard or risk of damage to components
1.2 TOOLS REQUIRED
Use appropriate tools and equipment in working environments which
!
comply with applicable legislation.
4 Symbols: work tools
HEX SPANNER of size indicated
8 ; 19
FLAT SCREWDRIVER
PHILLIPS SCREWDRIVER
ALLEN KEY with ROUND HEAD of the size(s) indicated
4
ELECTRICIAN'S SCISSORS
ELECTROCUTION HAZARD Risk of electric shock from live parts
CRUSHING HAZARD Risk of crushing of hands/feet due to the presence of heavy parts
Translation of the original instructions
CUTTING/AMPUTATION/PIERCING HAZARD Cutting hazard due to the presence of sharp components or the use of
pointed/sharp tools (drill)
SHEARING HAZARD Risk of shearing due to moving parts
RISK OF IMPACT/CRUSHING Risk of impact or crushing due to moving parts
RISK OF TRIPPING Risk of tripping over due to the presence of thresholds higher than 5mm
3 Symbols: personal protective equipment
Personal protective equipment must be worn to protect against hazards (e.g. crushing, cutting, shearing etc.):
WIRE STRIPPER/TERMINAL CRIMPER
Obligation to wear work gloves
Obligation to wear safety footwear
Kit E850S 4 532181 - Rev.A
Page 5
2. KIT E850S
2.1 INTENDED USE
The Kit is specifically for the FAAC C850 gearmotor. The
Kit allows you to replace the electronic board E850 and inverter
with the electronic board E850S.
2.2 UNAUTHORISED USE
- Uses other than the intended use are prohibited.
- It is prohibited to power the system with energy sources other than those specified.
- It is prohibited to integrate commercial systems and/or equip- ment other than those specified, or use them for purposes not envisaged and authorised by the corresponding manufacturers.
- It is prohibited to use and/or install accessories which have not been specifically approved by FAAC S.p.A.
- It is prohibited to use the automation before performing com- missioning.
- It is prohibited to use the automation in the presence of faults which could compromise safety.
- It is prohibited to use the automation with the fixed and/or mobile guards removed or altered.
- Do not allow water jets of any type or size to come into direct contact with the gearmotor.
- Do not expose the gearmotor to corrosive chemical or atmos- pheric agents.
- Do not use the automation unless the area of operation is free of persons, animals or objects.
- Do not enter/remain in the area of operation of the automation while it is moving.
- Do not try to prevent the movement of the automation.
- Do not climb on, hold onto or let yourself be pulled by the leaf. Do not climb onto or sit on the gearmotor.
- Do not allow children to approach or play in the area of operation of the automation.
- Do not allow the control devices to be used by anyone who is not specifically authorised and trained to do so.
- Do not allow the control devices to be used by children or persons with mental and physical deficiencies unless they are supervised by an adult who is responsible for their safety.
2.4 COMPONENT IDENTIFICATION
2
1
3
5
5 Components
1 New frame 2 Electronic board E850S with plastic covers 3 New cable for the integrated limit switches 4 New cable for the electric motor 5 Fasteners
4
ENGLISH
1
Translation of the original instructions
2.3 TECHNICAL CHARACTERISTICS
The Kit E850S includes:
- the electronic board E850S for controlling the gearmotor C850
- a new support frame for the board E850S
- a new cable for connecting the integrated limit switches
- a new cable for connecting the electric motor
The electronic board E850S has an integrated:
- inverter for programming the opening and closing speeds independently
- fan for cooling the inverter
- LCD display and 2 buttons for programming the functions
Kit E850S 5 532181 - Rev.A
Page 6
BOARD E850S
COMPONENTS
ENGLISH
T10A
PE N L
PENL
J1
F1
BRAKE
BRAKE
LAMP
LAMP
J2
230V~ 30W
MOTOR
OPEN SX
J3 J4
U
V
W
M
3
J8
P3
RESET
P1 P2
ENTER UP/DWN
DL9
DL11
OPEN DX
W
V
DL10
U
OPEN B
OPEN
+
-
FAN
DISPLAY
DL12
DL13
OPEN A
SAFE
FSW CL
DL5
DL7
DL6
DL8
J7
J6
DL14
DL15
FSW OP
STOP
OP
R.OP
CL
R.CL
LIMIT
LIMIT
FAIL SAFE
J5 JP1
RADIO
COM
LOCK
SWITCH SX
JP3
SWITCH DX
JP2
+24V
-
W.L. COM NC NO
+24V
0.5A max
24V
0.2A
Translation of the original instructions
E850S
J 1 Power supply terminal board J 2 Electric brake and flashing light terminal board J 3 Left opening motor terminal board J 4 Right opening motor terminal board J 5 Control devices terminal board J 6 Failsafe terminal board J 7 LED and accessories power supply terminal board J 8 Cooling fan terminal board JP 1 Connector (5 pin) for radio/decoder board JP 2 Left opening limit switch connector JP 3 Right opening limit switch connector
DISPLAY Programming display
P 1 ENTER button P 2 UP/DWN button P 3 RESET button F 1 Power supply fuse T10A DL 5 Opening limit switch status LED DL 6 Closing limit switch status LED DL 7 Opening deceleration status LED DL 8 Closing deceleration status LED DL 9 OPEN input status LED DL 10 OPEN B input status LED DL 11 DL 12
OPEN A input status LED SAFE input status LED
DL 13 FSW CL input status LED DL 14 FSW OP input status LED DL 15 STOP input status LED
2
6 Board technical data E850S
Power supply voltage 230 V~(+6% -10%) 50/60 Hz
Max power 18 W Accessories output voltage 24 V
Max. motor power 1.5 KW
Max. accessories load 500 mA
Max. flashing light load 30 W (230 V~)
Ambient operating temperature -20 °C - +55 °C
Kit E850S 6 532181 - Rev.A
Page 7
3. PRELIMINARY OPERATIONS
RISKS
PERSONAL PROTECTIVE EQUIPMENT
Always shut off the power supply before performing any work. If
F
the disconnect switch is not in view, apply a warning sign stating “WARNING - Maintenance in Progress”.
3.1 REMOVING THE COVER
1. Unscrew the 4 screws and remove the cover (3).
2. Put the cover and the 4 screws to one side.
3.2 DISCONNECTING THE ELECTRONIC BOARD E850
1. Disconnect the power supply and earth wires from the C850
(4-1).
2. Unscrew the screws of the plastic cover of the E850 board. Re-
move the plastic cover. (5).
3. Disconnect the limit switch cable from the E850 board. Remove
the limit switch cable from the conduit (6).
4. Unscrew the 4 screws of the electric motor junction box and re-
move the cover (7-1). Put the screws and cover to one side.
5. Remove the 3 nuts that connect the cable lugs of the electric motor
(7-2). Put the nuts to one side.
6. Unscrew the electric motor cable gland
(7-3). Remove the electric motor cable from the cable gland (7-4).
7. Disconnect the remaining wires from the electronic board
E850. Remove the wires from the conduits.
1
4
4
5
ENGLISH
Translation of the original instructions
6
2
3
4
Kit E850S 7 532181 - Rev.A
3
1
4
7
Page 8
3.3 REMOVING THE ORIGINAL FRAME
1. Unscrew the 2 screws and 2 nuts that fasten the frame to the base
of the operator (8-9).
2. Remove the frame from the base of the operator (10).
ENGLISH
3.4 DISCONNECT THE LIMIT SWITCHES
1. Unscrew the 2 screws of the limit switch unit cover Remove the
cover (11-1). Put the cover and screws to one side.
2. Unscrew the cable gland from the limit switch unit (11-2).
3. Disconnect the cable lugs from the micro switches and remove
the limit switch cable from the cable gland (11-3).
1
3
Translation of the original instructions
4 8
4 8
8
9
2
19
11
10
Kit E850S 8 532181 - Rev.A
Page 9
4. INSTALLATION
RISKS
PERSONAL PROTECTIVE EQUIPMENT
YELLOW
4.1 CONNECTING THE NEW LIMIT SWITCH CABLE
1. Take the cable gland seal from the Kit as shown in 12-1.
2. Take the new limit switch cable included in the
in the cable gland seal. Insert the cable lugs into the cable gland seal in the direction shown in 12-2.
3. Slide the cable gland seal along the limit switch cable.
4. Insert the cable lugs into the cable gland of the limit switch unit.
(13).
5. Connect the cable lugs to the micro limit switches. Follow the
colour scheme indicated in 14.
6. Tighten the limit switch unit cable gland (15).
Kit. Make a hole
4.2 CONNECTING THE NEW ELECTRIC MOTOR CABLE
1. Take the new electric motor cable included in the Kit.
2. Insert the ring cable lugs into the electric motor cable gland
(16).
3. Connect the ring cable lugs to the electric motor as follows:
U1 Grey/Black V1 Blue W1 Brown
2
EMPTY
EMPTY
EMPTY
EMPTY
19
WHITE
GREY
GREEN
BROWN
14
15
ENGLISH
Translation of the original instructions
1
12
13
16
17
Kit E850S 9 532181 - Rev.A
Page 10
4. Tighten the 3 nuts that had been put aside previously onto the
ring cable lugs (18-1).
5. Tighten the electric motor cable gland (18-2).
6. Place the cover on the electric motor junction box. Tighten the
4 screws of the cover that had been put aside previously (18-3).
ENGLISH
1
3
2
4.3 INSTALLING THE NEW FRAME
1. Place the new frame on the base in the same position as the old
frame 19).
2. Fasten the new frame using the 2 nuts, the 2 screws and the 4
washers included in the Kit (20-21)
Translation of the original instructions
18
4 8
21
4.4 REMOVING THE PLASTIC COVERS
1. Unscrew the 7 fixing screws from the plastic covers of the E850S
board. Remove the plastic covers (22).
2. Put the plastic covers and fixing screws to one side.
19
4 8
Kit E850S 10 532181 - Rev.A
20
22
Page 11
4.5 CONNECTIONS TO THE BOARD E850S
LIMIT SWITCHES
1. Fasten the limit switch cable to the cable clips on the frame
(23-1).
2. Insert the limit switch cable and the cable gland seal into the hole
indicated in 23-2.
3. Depending on the direction in which the gate opens, plug the
limit switch connector into:
- JP3 if the gate opens towards the left (24)
- JP2 if the gate opens towards the right (25)
The direction in which the gate opens refers to when looking at the
gate while standing in front of the C850 (26,27).
1 1
2
ELECTRIC BRAKE
1. Fasten the electric brake cable to the cable clip on the frame
(28-1).
2. Make a hole in the cable gland seal. Insert the electric brake
cable into the cable gland seal (28-2).
3. Connect the 2 wires of the electric brake to the BRAKE terminals
of J2 (28-3).
The electric brake connection has no polarity.
J2
BRAKE
BRAKE
1
3
J2
2
ENGLISH
23
JP3
JP2
24 25
Opening to the left
28
SAFETY SWITCH ON RELEASE DEVICE
1. Fasten the safety switch cable to the cable clips on the frame
(29-1).
2. Make a hole in the cable gland seal. Inser t the safety switch cable
into the cable gland seal (29-2).
3. Connect the 2 wires of the safety switch to the LOCK and COM
terminals of J5 (30).
The safety switch connection has no polarity.
J5
1
2
Translation of the original instructions
29
26
Opening to the right
27
Kit E850S 11 532181 - Rev.A
COM
LOCK
30
J5
Page 12
ELECTRIC MOTOR
1. Make a hole in the cable gland seal. Insert the electric motor
cable into the cable gland seal (31-1).
2. Remove the three-pole terminal from J3 or J4.
3. Connect the wires of the motor to the three-pole terminal follow-
ing the colours indicated in 31.
4. Plug the wired three-pole terminal wired into:
- J3 if the gate opens towards the left
- J4 if the gate opens towards the right
The direction in which the gate opens refers to when looking at the
gate while standing in front of the C850.
ENGLISH
1
BROWN
BLUE
GREY/BLACK
J4
RADIO RECEIVER/DECODER BOARD
The quick insertion connector JP1 is specifically for 5-pin FAAC radio or decoder boards.
It is a polarised type of connector (36).
If a FAAC model RP receiver is used, it is recommended to install the
appropriate external antenna in order to obtain a sufficient range.
LED
The LED remotely indicates the status of the gate as follows:
gate status LED status
closed off opening on open on closing flashing
Insert the cable of the LED into the cable gland seal indicated in 37. Connect the LED (model 24 V" , maximum 0.2 A) to the
W.L. and - terminals of J7 (38).
ACCESSORIES POWER SUPPLY
The E850S supplies 24 V" max. 0.5 A for the connected accessories, on the +24V and - terminals of J7 ().
J3
Translation of the original instructions
MOTOR
OPEN SX
J3 J4
U
V
M
OPEN DX
W
V
W
U
3
FLASHING LIGHT
Insert the cable of the flashing light into the cable gland seal indicated in 33. Connect the flashing light (230 V~, max 30 W model), to the LAMP terminals of J2 (34).
COOLING FAN
The board cooling fan is connected at the factory to J8 (35). The fan is powered by a DC voltage. The connection is therefore
polarised. The fan is started and stopped by the board according to the temper-
ature of the component to be cooled.
31
32
J7
J2
J8
J2
LAMP
LAMP
230V~
33
35
37 38
30W
J7
24V
0.2A
W.L.
34
JP1
36
-
Kit E850S 12 532181 - Rev.A
Page 13
CONTROL DEVICES
Connect the devices to terminal board J5.
Multiple NO contacts on same input must be connected in parallel.
Multiple NC contacts on same input must be connected in series.
TERMINAL BOARD J5
OPEN
OPEN B
OPEN A
SAFE
FSW CL
FSW OP
STOP
LOCK
COM INPUT Common contacts
NO contact, connect a push-button or another type of pulse generator which, by closing a contact, commands only the total opening of the automation.
NO contact, connect a push-button or another type of pulse generator which, by closing a contact, commands only the partial opening of the gate.
Can be configured as CLOSE by setting programming parameter A=1; in this case it becomes a NO contact to which to connect a push-button or another type of pulse generator which, by closing a contact, commands only the closing of the automation.
NO contact, connect a push-button or another type of pulse generator which, by closing a contact, commands the total opening of the gate.
The effect that subsequent pulses have depends on programming parameter d.
NC contact, connect a safety edge or other safety device which, by opening a contact, causes the gate to reverse slightly before stopping the automation. Active during both opening and closing.
NC contact, connect a photocell or another device which, by opening a contact during closing, causes the gate to reverse.
NC contact, connect a photocell or another device which, by opening a contact during opening, causes the gate to stop; when released, the gate continues to open.
NC contact, connect a push-button or another type of pulse generator which, by opening a contact, causes the automation to stop. The following cycle takes place slowly until the gate is completely open.
If the input is not used, bridge it with COM INPUT.
NC contact, used for connecting the safety switch on the release device at the factory.
SAFE
FSW CL/FSW OP/SAFE
COM INPUT
COM INPUT
+24V
J7
J6
FSW CL
FSW OP
1 2 3 4 5
+24V
-
COM NC
FAIL SAFE
J5
COM INPUT
■ 1 pair of photocells
■ 2 pairs of photocells
NO
RADIO
ENGLISH
NC
1
+24V
2
Translation of the original instructions
If one or more SAFE, FSW CL, FSW OP inputs are not used:
- With Failsafe disabled: bridge the input with COM INPUT
- With Failsafe enabled: see below
FAILSAFE
The failsafe is a test to check the operation of the safety devices con­nected to the inputs ily interrupting the power supply to the devices before any movement takes place and checking the change in status of the inputs.
In order for the test to be performed, it must be enabled (parameter b=1).
Terminal board J6 (39) provides a volt free contact (NO or NC) to be used to interrupt the power supply.
39 shows the connection of one pair and two pairs of photocells (connected in series). In this configuration, if one or more of the
FSW CL, FSW OP inputs are not used, bridge them with NC of J6.
SAFE, FSW CL, FSW OP. It consists of momentar-
SAFE,
FSW CL/FSW OP/SAFE
COM INPUT
+24V
NC
+24V
1 2 3 4
NC
1
+24V
2
5
1
1 2
2 3 4
5
COM INPUT
COM INPUT
+24V
39
Kit E850S 13 532181 - Rev.A
Page 14
POWER SUPPLY AND GROUNDING
Carry out the following operations with the power supply disconnected.
F
1. Crimp the system earth wire, using the supplied terminal.
2. Install the M5 nut, washer and terminal supplied onto the gear
motor earth connection (40-1). Tighten the nut.
3. Connect the phase and neutral wires of the power supply to ter-
minals L and N respectively of J1 (40).
5. START-UP
RISKS
PE
PE N L
L
N
J1
ENGLISH
PERSONAL PROTECTIVE EQUIPMENT
During operation there is a risk of fingers and hands being trapped
!
between the rack, pinion and cover.
If the gate is not engaging a limit switch, any movement following
a start or reset during opening takes place at a slow speed until it reaches the limit switch.
1. Make sure that the motor and limit switch cables are plugged into the correct connectors, according to the direction in which the gate opens.
2. Install the high voltage protection cover on the board E850S and fasten it in place using the 4 screws that were put aside previously (41).
Translation of the original instructions
3. Make sure that the C850 has been released (§ 5.1).
4. Power up the system.
5. Adjust the integrated limit switches (§ 5.2).
6. Programming the E850S board (§ 5.3)
7. Restore automatic operation (§ 5.1).
8. Carry out the procedure for putting the system into service (§ 6).
8
1
40
41
5.1 MANUAL OPERATION
Before performing the release operation, shut off the power supply
!
to the automation. During manual operation, gently guide the leaf the whole way. Do not
push it and let it slide freely. Do not leave the gate with the release engaged: after moving it man-
ually, restore automatic operation.
RELEASE PROCEDURE
1. Turn the lock protection shutter clockwise
2. Insert the release key and rotate it anticlockwise by a quarter of a turn
3. Turn the release knob clockwise until it stops
RESTORING AUTOMATIC OPERATION
1. Turn the release knob anticlockwise until it stops
2. Turn the release key clockwise until it stops, then remove it
3. Turn the lock protection shutter anticlockwise
4. Manually move the gate until the mechanical system engages.
Kit E850S 14 532181 - Rev.A
42 43
44 45
Page 15
5.2 LIMIT SWITCH ADJUSTMENT
C850 must be released.
The deceleration starting points and stop points are set by adjusting the integrated limit switches. The maximum deceleration space that can be set is 5 m. The minimum deceleration space depends on the programmed speed (parameters
7 Minimum deceleration spaces
L0
L2 L3
Loosen the central screw of the limit switch unit by one turn (46).
OPENING TO THE LEFT
minimum distance from the stop point: 10 cm
minimum distance from the stop point: 40 cm
L1
minimum distance from the stop point: 70 cm
minimum distance from the stop point: 130 cm
Failure to comply with the minimum distances indicated in 7 can
!
jeopardise the integrity and operation of the C850 and be a potential safety hazard.
L. and .L):
A
46
ENGLISH
8 Opening to the left
function cam to be adjusted
closing cam 3 closing deceleration cam 4 opening deceleration cam 1 opening cam 2
1. Close the gate as far as the required closed position. The closed position must be at least 10 cm from the external mechanical stop.
2. Using a screwdriver, turn screw number 3 anticlockwise until the cam engages the micro switch, as shown in 47. When the micro switch is activated, the LED DL6 (CL) turns off.
3. Open the gate as far as the closing deceleration starting point.
4. Using a screwdriver, turn screw number 4 anticlockwise until the cam engages the micro switch as shown in 48 When the micro switch is activated, the LED DL8 (R.CL) turns off.
5. Open the gate as far as the required opening deceleration starting point.
6. Using a screwdriver, turn screw number 1 clockwise until the cam engages the micro switch, as shown in 49. When the micro switch is activated, the LED DL7 (R.OP) turns off.
7. Open the gate as far as the required open position. The open position must be at least 10 cm from the external mechanical stop.
8. Using a screwdriver, turn screw number 2 clockwise until the cam engages the micro switch, as shown in 50. When the micro switch is activated, the LED DL5 (OP) turns off.
direction of adjustment
   
3 - CL -
47
Translation of the original instructions
4 -R.CL -
48
1 -R.OP -
49
2 -OP -
50
Kit E850S 15 532181 - Rev.A
Page 16
OPENING TO THE RIGHT
9 Opening to the right
function cam to be adjusted
closing cam 2 closing deceleration cam 1 opening deceleration cam 4 opening cam 3
1. Close the gate as far as the required closed position. The closed position must be at least 10 cm from the external mechanical stop.
2. Using a screwdriver, turn screw number 2 clockwise until the cam engages the micro switch, as shown in 51. When the micro switch is activated, the LED DL6 (CL) turns off.
3. Open the gate as far as the required closing deceleration starting point.
4. Using a screwdriver, turn screw number 1 clockwise until the cam
ENGLISH
engages the micro switch, as shown in 52 When the micro switch is activated, the LED DL8 (R.CL) turns off.
5. Open the gate as far as the opening deceleration starting point.
6. Using a screwdriver turn screw number 4 anticlockwise until the cam engages the micro switch, as shown in 53. When the micro switch is activated, the LED DL7 (R.OP) turns off.
7. Open the gate as far as the required open position. The open position must be at least 10 cm from the external mechanical stop.
8. Using a screwdriver turn screw number 3 anticlockwise until the cam engages the micro switch, as shown in 54. When the micro switch is activated, the LED DL5 (OP) turns off.
direction of adjustment
   
2 -CL -
51
1 -R.CL -
52
4 -R.OP -
Translation of the original instructions
Tighten the central screw of the limit switch unit by one turn (55).
!
Replace the cover of the limit switch unit using the screws that were put aside previously (56).
53
3 - OP -
54
55
56
Kit E850S 16 532181 - Rev.A
Page 17
5.3 PROGRAMMING
To access the programming menu, the display must indicate the gate
closed status (00). To access the programming mode from whichever state the gate is in,
press and release the
Press button P1 (ENTER), for approximately 5 seconds, until the first parameter A appears.
Press button P2 (UP/DWN) to modify the value of the parameter. Press button P1 ( After 60 seconds of inactivity, the system will automatically exit from
the programming menu saving any changes that were made.
parameter default
OPEN B input configuration
A
0 partial opening only
ENTER) to go to the next parameter.
RESET button: 00 appears on the display.
0
1 closes only (CLOSE)
Failsafe
b
0 not enabled
0
1 enabled
Automatic closing
c
0 not enabled
0
1 enabled, pause 5 s 2 enabled, pause 10 s 3 enabled, pause 15 s 4 enabled, pause 20 s 5 enabled, pause 25 s 6 enabled, pause 30 s 7 enabled, pause 40 s 8 enabled, pause 80 s 9 enabled, pause 120 s
OPEN A operation
d
0 open/stop/close/open...
0
1 open/close/open..."
Partial opening time
E
0 3 s
0
1 5 s 2 8 s 3 10 s
Condominium function
H
0 not enabled (the OPEN A command is operative during
opening)
0
1 enabled (the OPEN command is ignored during opening)
Maximum opening speed
L.
0 10 m/min
0
1 20 m/min 2 30 m/min 3 40 m/min
Maximum closing speed
.L
0 10 m/min
0
1 20 m/min 2 30 m/min 3 40 m/min
Immediate closure after transit across photocells
o
0 not enabled (with automatic closing enabled, the gate always
closes after the pause time)
0
1 enabled (with automatic closing enabled, the gate closes
immediately after transit across the closing photocells)
parameter default
Timer function
P
0 not enabled
1
1 enabled (the OPEN A maintained action control keeps the gate
open until released)
Dead-man function
U
0 not enabled
0
1 enabled (requires the OPEN A and CLOSE maintained action
controls to be used)
In the dead-man mode:
!
- The control must be activated intentionally and the gate must be visible
- The OPEN input is disabled.
- If the SAFE input is activated during opening or closing, it stops the movement immediately.
- If the FSW CL input is activated during closing, it stops the movement.
- If the FSW OP input is activated during opening, it stops the movement.
- the speed of the gate must be less than 5 m/min
Pre-flashing during closing
Y
0 not enabled
0
1 1 s 2 2 s 3 3 s 4 4 s
The display, other than when in the programming menu, provides information regarding the status of the automation (§ 7.2).
ENGLISH
Translation of the original instructions
Kit E850S 17 532181 - Rev.A
Page 18
6. PUTTING INTO SERVICE
Carry out the following operations with the power supply disconnected.
F
Before installing the board cover and casing you must have:
- completed the start-up procedure
- checked that the C850and the installed devices are working properly.
1. Install the low voltage protection cover on the board E850S and fasten it in place using the 3 screws that were put aside previously (57).
2. Install the cover and fasten it using the 4 screws that were put aside previously (58).
6.1 FINAL CHECKS
1. Make sure that the forces generated by the leaf are within the limits permitted by the current regulations. Use an impact force tester in accordance with standards EN 12453 and EN 12445. For non-EU countries, of there are no specific local regulations, the
ENGLISH
force must be less than 150 N.
2. Check that the maximum force required to move the leaf by hand is less than 260 N.
3. Check that the C850 and the installed devices are working properly.
7. DIAGNOSTICS
7.1 LEDS CHECK
10 Status of the LEDs
LED meaning
DL5 OP opening limit switch not engaged engaged DL6 OP closing limit switch not engaged engaged DL7 R.OP deceleration during opening not engaged engaged DL8 R.CL deceleration during closing not engaged engaged DL9 OPEN OPEN input active not active DL10 OPEN B OPEN B input active not active DL11 OPEN A OPEN A input active not active DL12 SAFE SAFE input not active active DL13 FSW CL FSW CL input not active active DL14 FSW OP FSW OP input not active active DL15 STOP STOP input not active active
Bold indicates the condition of the LEDs with the board powered, the
gate at its halfway position and no connected device active (=on ; =off).
7.2 STATUS OF THE AUTOMATION
The display, other than when in the programming menu, provides information regarding the status of the automation:

Translation of the original instructions
57
11 Status of the automation
display meaning
00 02 04 06
ST ER
gate closed
gate opening/open
gate open in pause
gate closing
the dead-man function is active and the gate has not yet com­pleted the opening or closing cycle
the failsafe function is active and the test has failed on at least one device (the
dot on the left lit FSW OP input active
.8.8
.8.8
dot on the right lit FSW CL input active
LAMP output flashes quickly at the same time)
4
Kit E850S 18 532181 - Rev.A
58
Page 19
Page 20
FAAC S.p.A. Soc. Unipersonale Via Calari, 10 - 40069 Zola Predosa BOLOGNA - ITALY Tel. +39 051 61724 - Fax +39 051 758518 www.faac.it - www.faacgroup.com
Kit E850S 20 532181 - Rev.A
Loading...