EC DECLARATION OF CONFORMITY FOR MACHINES
(DIRECTIVE 98/37/EC)
Manufacturer: FAAC S.p.A.
Address: Via Benini, 1 - 40069 Zola Predosa BOLOGNA - ITALY
Declares that: 740 / 741 mod. operator with electronic control unit 740D
• is built to be integrated into a machine or to be assembled with other machinery to create a machine under the provisions of Directive 98/37/EC;
• conforms to the essential safety requirements of the following EEC directives:
73/23/EEC and subsequent amendment 93/68/EEC. 89/336/EEC and subsequent amendment 92/31/EEC and 93/68/EEC
and also declares that it is prohibited to put into service the machinery until the machine in which it will be integrated or of which it will become a component has been identified and declared as conforming to the conditions of Directive 98/37/EC.
Bologna, 01 January 2004
The Managing Director
A. Bassi
WARNINGS FOR THE INSTALLER
GENERAL SAFETY OBLIGATIONS
1) ATTENTION! To ensure the safety of people, it is important that you read all the following instructions. Incorrect installation or incorrect use of the product could cause serious harm to people.
2) Carefully read the instructions before beginning to install the product.
3) Do not leave packing materials (plastic, polystyrene, etc.) within reach of children as such materials are potential sources of danger.
4) Store these instructions for future reference.
5) This product was designed and built strictly for the use indicated in this documentation. Any other use, not expressly indicated here, could compromise the good condition/operation of the product and/or be a source of danger.
6) FAAC declines all liability caused by improper use or use other than that for which the automated system was intended.
7) Do not install the equipment in an explosive atmosphere: the presence of inflammable gas or fumes is a serious danger to safety.
8) The mechanical parts must conform to the provisions of Standards EN 12604 and EN 12605. For non-EU countries, to obtain an adequate level of safety, the Standards mentioned above must be observed, in addition to national legal regulations.
9) FAAC is not responsible for failure to observe Good Technique in the construction of the closing elements to be motorised, or for any deformation that may occur during use.
10) The installation must conform to Standards EN 12453 and EN 12445. For non-EU countries, to obtain an adequate level of safety, the Standards mentioned above must be observed, in addition to national legal regulations.
11) Before attempting any job on the system, cut out electrical power .
12) The mains power supply of the automated system must be fitted with an all-pole switch with contact opening distance of 3mm or greater. Use of a 6A thermal breaker with all-pole circuit break is recommended.
13) Make sure that a differential switch with threshold of 0.03 A is fitted upstream of the system.
14) Make sure that the earthing system is perfectly constructed, and connect metal parts of the means of the closure to it.
15) The automated system is supplied with an intrinsic anti-crushing safety device consisting of a torque control. Nevertheless, its tripping threshold must be checked as specified in the Standards indicated at point 10.
16) The safety devices (EN 12978 standard) protect any danger areas against mechanical movement Risks, such as crushing, dragging, and shearing.
17) Use of at least one indicator-light (e.g. FAACLIGHT ) is recommended for every system, as well as a warning sign adequately secured to the frame structure, in addition to the devices mentioned at point “16”.
18) FAAC declines all liability as concerns safety and efficient operation of the automated system, if system components not produced by FAAC are used.
19) For maintenance, strictly use original parts by FAAC.
20) Do not in any way modify the components of the automated system.
21) The installer shall supply all information concerning manual operation of the system in case of an emergency, and shall hand over to the user the warnings handbook supplied with the product.
22) Do not allow children or adults to stay near the product while it is operating.
23) Keep remote controls or other pulse generators away from children, to prevent the automated system from being activated involuntarily.
24)
Transit is permitted only when the automated system is idle.
25) The user must not attempt any kind of repair or direct action whatever and contact qualified personnel only.
26) Maintenance: check at least every 6 months the efficiency of the system, particularly the efficiency of the safety devices (including, where foreseen, the operator thrust force) and of the release devices.
27 ) Anything not expressly specified in these instructions is not permitted.
15
AUTOMATED SYSTEM 740-741
322
These instructions apply to the following models:
FAAC 740 - 741
The 740-741 gearmotor is an electro-mechanical operator designed for moving sliding gates. The non-reversing reduction system ensures the gate is mechanically locked when the gearmotor is not operating, therefore it is not necessary to install any electric lock
1. DESCRIPTION AND TECHNICAL SPECIFICATIONS
A convenient manual release with customised key makes it possible to move the gate in the event of a power failure or malfunction of the operator.
The 740-741 gearmotor was designed and built for controlling vehicle access. AVOID ANY OTHER USE WHATEVER.
1. Motor lid
2. Electronic control unit
3. Release device
4. Gearmotor body
5. Foundation plate
6. Pinion
7. Limit switch
8. Motor cover
9. Cable holes
10. Capacitor
11. Protective side panels
LEDOM047147V511047V511147
)%01-%6+(ylppusrewoP zH05~V032zH05~V032zH06~V511zH06~V511
)W(rewopdebrosbA 053005053006
)A(tnerrucdebrosbA 5.12.232.5
)Fµ(roticapaC 015.210305
)Nad(noinipnotsurhT 54565456
)mN(euqroT 81428142
)C°(noitcetorplamrehtgnidniW 041041041041
)gK(thgiewxamfaeL 005009005009
noinipfoepyT 61Z61Z61Z61Z
)nim/m(deepsetaG 21214141
)m(htgnelxametaG 51515151
hctiwstimilfoepyT lacinahceMlacinahceMlacinahceMlacinahceM
hctulC cinortcelEcinortcelEcinortcelEcinortcelE
ycneuqerfesU %03-3S%04-3S%03-3S%04-3S
)C°(erutarepmetgnitarepO 55+02-55+02-55+02-55+02-
)gK(thgiewrotomraeG 01110111
ssalcnoitcetorP 44PI44PI44PI44PI
snoisnemidllarevorotomraeG 20.giFeeS20.giFeeS20.giFeeS20.giFeeS
Fig.01
2. DIMENSIONS
Values are expressed in mm
221
16
5
1
8
0
9
2
Fig.02
3. MAXIMUM USE CURVE
d
)
)
)
)
)
The curve makes it possible to establish maximum work time (T) according to use frequency (F). With reference to IEC 34-1 Stan­dard, the 740-741 gearmotor with an S3 duty, can operate at a use frequency of 30-40%. To ensure efficient operation, it is necessary to operate in the work range below the curve.
Important: The curve is obtained
at a temperature of 20°C. Exposure to the direct sun rays can reduce use frequency down to 20%.
Percentuale
i lav. %
100
90
80
70
60
50
40
30
20
10
0
Tempo (h
% Fréquence d'utilisation
Temps (h
% Benutzungs­frequenz
10 11 12
Zeit (Std.
% Duty cycle
12345678910
Time (h
% Frecuencia de utilización
Tiempo (h
Calculation of use frequency
Use frequency is the percentage of effective work time (opening + closing) compared to total time of cycle (opening + closing + pau­se times). Calculation formula:
Ta + Tc
% F = X 100
Ta + Tc + Tp + Ti where: Ta = opening time Tc = closing time Tp = pause time Ti = time of interval between two complete cycles
4. ELECTRICAL SET-UP (standard system)
9a[PP
Warning: The arrow on the foundation plate must always point to
the gate, see Figs. 05-06.
3- After determining the position of the foundation plate, make
a plinth as shown in Fig. 07 and wall the plate, providing several sheaths for routing the cables. Using a spirit level, check if the plate is perfectly level. Wait for the cement to set.
4- Lay the electric cables for connection to the accessories and
power supply as shown in diagram of Fig. 03. To facilitate connections to the control unit, allow the cables to protrude by at least 50 cm from the hole on the foundation plate.
°
Values are expressed in mm
Values are expressed in mm
Values are expressed in mm
±5
56
±5
56
0÷50
0
2
3
1
8
0
0÷50
0
1
90
Fig.05
°
0
9
Fig.06
8
9
,
5
6
100
2
0
0
5
3
3
Fig.07
1- Operator with unit 2- Photocells 3- Key-operated push button 4- Flashing lamp 5- Radio receiver
Fig.03
5. INSTALLING THE AUTOMATED SYSTEM
5.1. Preliminary checks
To ensure safety and efficiency of the automated system, make sure the following requirements are observed before installing the system:
• The gate structure must be suitable for automation. The following are necessary in particular: wheel diameter must be in proportion to the weight of the gate, an upper track must be provided, plus mechanical travel stops to prevent the gate derailing.
• The soil must guarantee a perfect stability of the foundation plinth.
• There must be no pipes or electric cables in the plinth excavation area.
• If the gearmotor is located in the vehicle transit or manoeuvre area, adequate means of protection should be provided against accidental impact.
• Check if an efficient earthing is available for connection to the gearmotor.
5.2. Masonry for
Values are expressed in mm
foundation plate
1- Assemble the foundation
plate as shown in figure 04.
2- In order to ensure that the
pinion and rack engage correctly, the foundation plate must be positioned as shown
60-80
5.3. Mechanical installation
1- Remove the cover, Fig. 08 ref. 1. 2- Position the operator on the
foundation plate, using the supplied washers and nuts as shown in Fig. 09. During this operation, route the cables through the appropriate openings in the motor body (See Fig.01 ref.9). If necessary, the two holes can be joined using a hammer to obtain a wider space.
3- Adjust the height of the
gearmotor and the distance from the gate, referring to dimensions in Fig. 10.
Attention: This operation is
necessary to ensure the rack is correctly secured and to enable any new adjustments.
4- Secure the gearmotor to the
plate, tightening the nuts.
5- Prepare the operator for manual
operation as described in paragraph 8.
1
Fig.08
in Fig. 05 (right closing) or Fig. 06 (left closing).
Fig.04
Fig.09
17
Values are expressed in mm
Values are expressed in mm
90 (Z16)
42
56
12,5 ÷ 50
Fig.10
5.4. Assembling the rack
5.4.1. Steel rack to weld (Fig. 11)
1) Fit the three threaded pawls on the rack element, positioning them at the bottom of the slot. In this way, the slot play will enable any future adjustments to be made.
2) Manually take the leaf into its closing position.
3) Lay the first section of rack level on the pinion and weld the threaded pawl on the gate as shown in Fig.
13.
4) Move the gate manually, checking if the rack is resting on the pinion, and weld the second and third pawl.
5) Position another rack element end
Fig.11
to end with the previous one, using a section of rack (as shown in Fig. 14) to synchronise the teeth of the two elements.
6) Move the gate manually and weld the three threaded pawls, thus proceeding until the gate is fully covered.
5.4.2. Steel rack to screw (Fig. 12)
1) Manually take the leaf into its closing position.
2) Lay the first section of rack level on the pinion and place the spacer between the rack and the gate, positioning it at the bottom of the slot.
3) Mark the drilling point on the gate. Drill a Ø 6,5 mm hole and thread with an M8 male tap. Screw the bolt.
4) Move the gate manually, checking if the rack is resting on the pinion, and repeat the operations at point
Fig.12
3.
5) Position another rack element end to end with the previous one, using a section of rack (as shown in figure 14) to synchronise the teeth of the two elements.
6) Move the gate manually and carry out the securing operations as for the first element, thus proceeding until the gate is fully covered.
Fig.15
6. START-UP
6.1. Control board connection
Before attempting any work on the board (connections, programming, maintenance), always turn off power.
Follow points 10, 11, 12, 13 and14 of the GENERAL SAFETY OBLIGATIONS. Following the instructions in Fig. 3, route the cables through the raceways and make the necessary electric connections to the selected accessories. Always separate power cables from control and safety cables (push­button, receiver, photocells, etc.). To avoid any electric noise whatever, use separate sheaths.
6.1.1. Earthing
Connect the earth cables as shown in Fig.16 ref.A.
Fig.16
6.1.2. Electronic control unit
In the gearmotors, the electronic control unit is fitted to an adjustable support (Fig. 16 ref. 1) with transparent lid (Fig. 16 ref.
3). The board programming push buttons (Fig. 16 ref. 4) have been located on the lid. This allow the board to be programmed without removing the lid. For correct connection of the control unit, follow indications the specific instructions:
Notes on rack installation
• Make sure that, during the gate travel, all the rack elements do not exit the pinion.
• Do not, on any account, weld the rack elements either to the spacers or to each other.
• When the rack has been installed, to ensure it meshes correctly with the pinion, it is advisable to lower the gearmotor position by about 1.5 mm (Fig.15).
• Manually check if the gate correctly reaches the mechanical limit stops maintaining the pinion and rack coupled and make sure there is no friction during gate travel.
• Do not use grease or other lubricants between rack and pinion.
Fig.13
Fig.14
6.2. Positioning the limit switches
The operator has a mechanical travel stop with spring-lever, which commands gate movement to stop when a profiled steel plate, secured on the top of the rack, activates the spring until the microswitch is tripped. The plate support can be fitted to all racks with max. width of 13 mm. Procedure for correct positioning of the two travel stop plates supplied:
1) Fit and secure the 2 profiled steel plates on the 2 U-supports, using the supplied nuts and washers, as shown in figure 17.
2) Prepare the operator for manual operation as described in paragraph 8.
3) Power up the system.
4) Securing the opening limit switch: manually take the gate to opening position, leaving 20 mm from the mechanical travel stop.
5) Allow the plate to slide over the rack in opening direction (Fig.18). As soon as the opening limit switch LED on the control board goes off, take the plate forward by about 20÷30 mm and secure it provisionally on the rack, using the supplied screws.
6) Repeat the operations at points 4 and 5 for the closing limit switch, Fig. 19.
18
Fig.17
1
2
Fig.18
Important:
a) The plate must activate the limit-switch on the profiled part as
shown in figure 20.
b) If the wheel and the travel stop plate are too close, it may be
necessary to shorten the limit-switch spring by a couple of turns. Procedure for shortening the spring:
- To remove the spring, turn it clockwise. This operation requires some force.
- Shorten the spring as shown in Fig. 22: two turns correspond to about 3 mm.
- Fit the spring turning it clockwise, Fig. 23, until the stop is reached; see Fig. 24.
- Once the spring is back in place, ensure the wheel is horizontal. A wrong wheel orientation may jeopardise the operation of the limit switches.
Fig.19
Fig.20
2
3
3
Fig.25
Fig.26
8. MANUAL OPERATION
Warning: Cut power to the system to prevent an involuntary
pulse from activating the gate during the release manoeuvre.
To release the operator proceed as follows:
1) Insert the key provided and turn it clockwise as shown in Fig. 27 ref. 1 and 2.
2) Turn the release system clockwise, until the mechanical stop is reached, Fig. 27 ref. 3.
3) Open and close the gate manually.
3
2
1
Fig.27
Fig.21
Fig.23
8) Re-lock the system (see paragraph 9).
Important: Before sending a pulse, make sure that the gate
cannot be moved manually.
9) Command a complete gate cycle to check if the limit switch is tripped correctly.
Warning: To avoid damaging the operator and/or interrupting
operation of the automated system, allow a space of about 20 mm from the mechanical travel stops.
10) Appropriately adjust the position of the travel stop plates and definitively secure them on the rack.
7. TESTING THE AUTOMATED SYSTEM
After installing the operator, carefully check operating efficiency of all accessories and safety devices connected to it. Return the board support to its original position. Fit the cover (Fig. 25 ref. 1), tighten the two side screws provided (Fig. 25 ref 2) and snap-fit the side panels (Fig. 25 ref.3). Apply the danger sticker on the top of the cover (Fig. 26). Hand the “User’s Guide” to the Customer and explain correct operation and use of the gearmotor, indicating the potentially dangerous areas of the automated system.
Values are expressed in mm
Fig.22
Fig.24
9. RESTORING NORMAL OPERATION
Warning: Cut power to the system to prevent an involuntary pulse
from activating the gate during the manoeuvre for restoring normal operation.
To restore normal operation proceed as follows:
1) Turn the release system anti-clockwise, until its stop is reached, Fig. 28 ref. 1.
2) Turn the key anti-clockwise and remove it from the lock, Fig. 28 ref. 2 and 3.
3) Move the gate until the release system meshes (corresponds to gate locking)
4) Power up the system.
1
2
3
Fig.28
10. SPECIAL APPLICATIONS
There are no special applications.
11. MAINTENANCE
Check the operational efficiency of the system at least once every 6 months, especially as regards the efficiency of the safety and release devices (including operator thrust force).
12. REPAIRS
For any repairs, contact the authorised Repair Centres.
13. AVAILABLE ACCESSORIES
Refer to the catalogue for available accessories.
19
CONTROL BOARD 740D
1. WARNINGS
3. LAYOUT AND COMPONENTS
Important: Before attempting any work on the control board (connections, maintenance), always turn off power.
- Install, upstream of the system, a differential thermal breaker with adequate tripping threshold.
- Connect the earth cable to the appropriate terminal on the J7 connector of the equipment (see fig. 30).
- Always separate power cables from control and safety cables (push-button, receiver, photocells, etc.). To avoid any electric noise, use separate sheaths or a shielded cable (with earthed shield).
2. TECHNICAL SPECIFICATIONS
Model 740D-115V 740D-230V Power supply V~
( +6% -10%) 50 Hz
115 230
Absorbed power (W) 10 10 Motor max. load (W) 1200 1000 Accessories max. load (A) 0.5 0,5 Operating ambient temperature -20 °C +55 °C Protection fuses 2 (see fig. 29)
Function logics: Automatic / “Stepped” automatic / Semi-automatic / Safety
devices / Semi-automatic B / Dead-man C / “Stepped” semi-automatic / Mixed B/C logic
Work time Programmable (from 0 to 4 min.) Pause time Programmable (from 0 to 4 min.) Thrust force Adjustable over 50 levels Terminal board inputs Open / Pàartial opening / Safety devices at opng. /
Safety devices at clsng. / Stop / Edge / Power supply + Earth
On-connector inputs Opening and closing limit-switches / Encoder Terminal board outputs Flashing lamp - Motor - 24 Vdc accessories power
supply - 24 Vdc indicator-light / Timed output. - Fail safe
Rapid connector 5-pin card connection for Minidec, Decoder or RP receivers Programming 3 keys (+, -, F) and display, "basic" or "advanced" mode Basic mode programmable functions Function logic - Pause time - Thrust Force
- Gate direction Advanced mode programmable functions: Torque at initial thrust - Braking - Fail safe­Pre-flashing - Indicator-light/Timed output/Electric lock or 'traffic lights' command ­Opening and closing safety devices logic - Encoder/ Anti-crushing sensitivity ­Decelerations - Partial opening time - Work time - Assistance request - Cycle counter
RADIO
J2
ENCODER
J5
J5
LIMITS ENCODER
DL SIGNALLING AND PROGRAMMING DISPLAY Led INPUTS STATUS CONTROL LED J1 LOW VOLTAGE TERMINAL BOARD J2 CONNECTOR FOR DECODER/MINIDEC/RP RECEIVER J3 ENCODER CONNECTOR J5 LIMIT -SWITCH CONNECTOR J6 MOTORS AND FLASHING LAMP CONNECTION TERMINAL BOARD J7 F1 F2 LOW VOLTAGE AND ACCESSORIES FUSE (T 800mA) F "F" PROGRAMMING PUSH-BUTTON "–" PROGRAMMING PUSH-BUTTON
4. ELECTRIC CONNECTIONS
+ "+" PROGRAMMING PUSH-BUTTON
DL
F
-
+
F
+
J2
FCA
OPEN
FSW
STOP
OP
B
F2
F2
F1
Led
FCC
J3
J3
POWER SUPPLY TERMINAL BOARD 115Vac(740D-115V)-230Vac(740D-230V
FSW
OPEN
A
A
OPEN
1 2 3 4 5 6 7 8 9 10 11 12
EDGE
CL
SAFE
STOP
EDGE
ACCESSORIES
24V
--
+
+
TX-FSW
OP
CL
B
OPEN
FSW
FSW
J1
W.L.
J6
J1
N
COM
OPEN
CLOSE
13 14 15 16 17
J6
MOTOR
LAMP
LAMP
F1
PE
PE N L
MAIN
Fig. 29
L
N
J7
J7
)
MOTORS AND TRANSF. PRIMARY FUSE (740D 115V=F10A - 740D 230V=F 5A)
J5
LIMITS ENCODER
LIMIT-SWITCH
J3
ENCODER (optional)
24V
--
+
+
TX-FSW
A
OPEN
B
OPEN
OP
FSW
CL
FSW
STOP
EDGE
1 2 3 4 5 6 7 8 9 10 11 12
ACCESSORIES
For connection of the
photocells and safety
devices, see paragraph
4.1.
PARTIALLY OPEN
NB.: The capacitor is supplied with the operator.TOTALLY OPEN
20
W.L.
24 Vdc
3 W
L
OPEN
CLOSE
N
LAMP
COM
J6
J1
13 14 15 16 17
MOTOR
BLUE
M
LAMP
C
115Vac
N
PE
PE N L
MAIN
J7
(740D 115V)
max. 60W
-
230 Vac
(740D 230V)
max. 60W
115Vac 50-60Hz
(740D 115V)
-
230Vac 50-60Hz
(740D 230V)
STOP
Fig. 30
V
4.1.
Connection of photocells and safety devices
Before connecting the photocells (or other devices) we advise you to select the type of operation according to the movement area they have to protect (see fig. 31):
Opening/closing
safety devices
Opening safety
devices
"Edge" safety devices
Closing safety device
Opening safety devices:
they are tripped when an obstacle is
Fig. 31
detected only during gate opening movement. They cause immediate closure and resumption of opening motion on release (see programming in par.5.2).
Closing safety devices:
they are tripped when an obstacle is detected only during gate closing movement. They cau­se re-opening, either immediate or on release (see programming in par.5.2).
Opening/closing safety devices:
they are tripped during the gate opening and closing movements. They cause stopping and restart motion on release.
"Edge" safety devices:
they are tripped during the gate opening and closing movements. They cause immediate reversal of motion and stopping after two seconds.
Encoder:
it is tripped if there is an obstacle during gate opening and closing movements. It causes immediate reversal of motion and stopping after two seconds.
Connection of an "edge" safety device
24V
--
+
+
TX-FSW
W.L.
OPEN
OP
CL
B
A
OPEN
FSW
FSW
STOP
EDGE
1 2 3 4 5 6 7 8 9 10 11 12
Connection of a pair of photocells for opening
24V
--
+
+
TX-FSW
W.L.
A
OPEN
B
OPEN
OP
FSW
CL
FSW
STOP
EDGE
1 2 3 4 5 6 7 8 9 10 11 12
RX
1
2
3
4
-
+
5
TX
1
-
+
2
Connection of a pair of closing photocells
24V
--
+
+
TX-FSW
W.L.
A
OPEN
B
OPEN
OP
FSW
CL
FSW
STOP
EDGE
1 2 3 4 5 6 7 8 9 10 11 12
Fig. 35
Fig. 36
N.B. If two or more safety devices have the same function (opening, closing, opening and closing, edge), the contacts must be connected to each other in series (fig. 32). N.C. contacts must be used.
Connection of two N.C. contacts in series
(e.g. Photocells, Stop, Edge, etc.)
Fig. 32
N.B: If safety devices are not used, jumper connect the terminals as shown in fig. 33.
Connection of no safety device
24V
--
+
+
TX-FSW
W.L.
A
OPEN
B
OPEN
OP
FSW
CL
FSW
STOP
EDGE
1 2 3 4 5 6 7 8 9 10 11 12
Fig. 33
The most common photocell and safety device lay-outs are shown below (from fig. 34 to fig. 41).
Connection of a closing safety device and an opening
safety device
24V
--
+
+
TX-FSW
W.L.
A
OPEN
B
OPEN
OP
FSW
CL
FSW
STOP
EDGE
1 2 3 4 5 6 7 8 9 10 11 12
Fig. 34
RX
1
2
3
4
-
+
5
TX
1
-
+
2
Fig. 37
Connection of a pair of opening photocells, a pair of closing
photocell and an edge safety device
24
--
+
+
TX-FSW
W.L.
A
OPEN
B
OPEN
OP
FSW
CL
FSW
STOP
EDGE
1 2 3 4 5 6 7 8 9 10 11 12
RX CL
1
2
3
4
5
TX OP
1
-
+
2
-
+
TX CL
RX OP
1
-
+
2
1
2
3
4
-
+
5
Fig. 38
21
V
Connection of two pairs of closing photocells and two
edge safety devices
Connection of a pair of closing photocells and a pair of
opening/closing photocells
24
--
+
+
TX-FSW
A
OPEN
B
OPEN
OP
FSW
CL
FSW
STOP
EDGE
1 2 3 4 5 6 7 8 9 10 11 12
RX CL1
1
2
3
4
5
TX CL2
1
2
-
+
TX CL1
-
+
RX CL2
1
2
1
2
3
4
5
W.L.
Fig. 39
A
OPEN
B
OPEN
OP
FSW
CL
FSW
STOP
EDGE
24V
--
+
+
1 2 3 4 5 6 7 8 9 10 11 12
RX CL TX CL
1
2
3
4
-
+
5
1
2
TX OP/CL
-
+
RX OP/CL
1
2
1
2
3
4
5
Connection of two N.O. contacts in parallel
(e.g. Open A, Open B)
TX-FSW
W.L.
Fig. 41
Connection of a pair of closing photocells, a pair of opening
photocells and a pair of opening/closing photocells
24V
--
+
+
TX-FSW
W.L.
A
OPEN
B
OPEN
OP
FSW
CL
FSW
STOP
EDGE
1 2 3 4 5 6 7 8 9 10 11 12
RX CL TX CL
1
2
3
4
-
+
5
1
2
TX OP/CL
RX OP TX OP
1
2
3
4
-
+
5
-
+
RX OP/CL
-
+
1
2
1
2
3
4
5
1
2
Fig. 40
Fig. 42
4.2. J7 Terminal board - Power supply (fig. 30)
POWER SUPPLY (terminals PE-N-L): PE: Earth connection N:Power supply ( Neutral ) L:Power supply ( Line )
NB.: For correct operation, the board must be connected to the
earth conductor in the system. Install an adequate differential thermal breaker upstream of the system.
4.3. J6 Terminal board - Motors and flashing lamp (fig. 30)
MOTOR - (terminals 13-14-15): Motor connection.
In gearmotors with a built-in control unit, this connection is pre­wired standard. For leaf opening direction, see basic programming in par. 5.1.
LAMP - (terminals 16 -17): Flashing lamp output.
4.4. J1 Terminal board - Accessories (fig. 30)
OPEN A - "Total Opening" command (terminal 1): any pulse
generator (push-button, detector, etc.) which, by closing a contact, commands total opening and/or closing of the gate leaf.
To install several total opening pulse generators, connect the N.O. contacts in parallel (see fig. 42).
OPEN B - "Partial opening " or "Closing" command (terminal 2):
any pulse generator (push-button, detector, etc.) which, by closing a contact, commands partial opening and/or closing of the gate leaf. In the B, C and B/C logics, it always commands gate closure.
To install several partial opening pulse generators, connect the N.O. contacts in parallel (see fig. 42).
22
MINIDEC
PLUS
RP
FSW OP - Opening safety devices contact (terminal 3): The
purpose of the opening safety devices is to protect the leaf movement area during opening. During opening, in the A- AP-S-E-EP logics the safety devices reverse the movement of the gate leaves, or stop and restart the movement when they are released (see advanced programming in Par 5.2). During the opening cycle in logics B, C and B/C, they interrupt movement. They never operate during the closing cycle. If the Opening safety devices are engaged when the gate is closed, they prevent the leaf opening movement. To install several safety devices, connect the N.C. contacts in series (fig. 32).
NB.: If no opening safety devices are connected, jumper connect inputs OP and -TX FSW (fig. 33).
FSW CL - Closing safety devices contact (
purpose of the closing safety devices is to protect the leaf movement area during closing. During closing, in the A- AP-S-E-EP logics, the safety devices reverse the movement of the gate leaves, or stop and reverse the movement when they Par 5.2 interrupt movement. They never operate during the opening cycle. If the Closing safety devices are engaged when the gate is open, they prevent the leaf closing movement. To install several safety devices, connect the N.C. contacts in series (fig. 32).
are released (see advanced programming in
). During the closing cycle in logics B, C and B/C, they
terminal
4): The
NB.: If no closing safety devices are connected, jumper connect terminals CL and -TX FSW (fig. 33).
STOP - STOP contact (
button) which, by opening a contact, is able to stop gate movement. To install several STOP devices, connect the N.C. contacts in series.
terminal
5): any device (e.g. a push-
NB.: If STOP devices are not connected, jumper connect the STOP and - terminals.
EDGE - EDGE safety device contact (terminal 6): The purpose of
the "edge" safety device is to protect the leaf movement area during opening/closing against fixed obstacles (pillars, walls, etc.). In all logics, during opening and closing, the safety devices reverse gate leaf movement for 2 seconds. If the safety devices operate again during the 2-seconds reversing time, they STOP movement without any reversing. If the Edge safety devices are engaged while the gate is closed or open, they prevent the leaves movement. To install several safety devices, connect the N.C. contacts in series (fig. 32).
NB.: If edge safety devices are not connected, jumper connect the EDGE and - inputs. (fig. 33).
Negative for power supply to accessories (terminals 7 and
8)
+ 24 Vdc - Positive for power supply to accessories (terminals
9 and 10) Important: Accessories max. load is 500 mA. To calculate
absorption values, refer to the instructions for individual accessories.
TX -FSW - Negative for power supply to photocell transmitters
(terminal 11)
If you use this terminal for connecting the negative for supplying power to the photocell transmitters, you may, if necessary, also use the FAIL SAFE function (see advanced programming in par. 5.2). If this function is enabled, the equipment checks operation of the photocells before every opening or closing cycle.
W.L. - Power supply to indicator light / timed exit / electric lock/
'traffic lights' (terminal 12)
Connect any 24 Vdc - 3 W max indicator light, timed exit, command device for electric lock or 'traffic lights' between this terminal and the +24V (see advanced programming in par. 5.2). To avoid geopardising correct operation of the system, do not exceed the indicated power.
4.5.
Connector J2 - Rapid connection to Minidec, Decoder and RP
This is used for rapid connection of Minidec, Decoder and RP receivers (see fig.
43, 44, 45). Connect the accessory, with the
components side facing the inside of the board. Insert and remove after cutting power.
PLUS
740D 740D
DECODER
Fig. 43
Fig. 44
740D
Fig. 45
4.6. Connector J6 - Limit-switches rapid connection (fig. 30)
This input is intended for rapid connection of the opening and closing limit-switches designed to stop the leaf, or for start of decelerations or for braking (see advanced programming in Par. 5.2.). In gearmotors with a built-in control unit, this connection is pre-wired as standard (fig. 30). For leaf opening direction, see advanced programming in Par 5.2.
4.7. Connector J3 - Encoder rapid connection (fig. 30)
This input is designed for rapid connection of the Encoder (optional). To fit the encoder on the motor, refer to the relevant instructions. The presence of the encoder is signalled - when the gearmotor is running - by the flashing of the "Encoder" LED on the board. When the encoder is used, the control unit knows the exact position of the gate while it is moving. The encoder controls the adjustments of some of the control unit's functions in a different way (partial opening or deceleration - see advanced programming in Par 5.2) and as an anti-crushing device. If the gate strikes an obstacle during opening or closing, the encoder immediately reverses the gate leaf for 2 seconds. If the encoder operates again during the 2 seconds reversing time, it STOPS movement without commanding any reversing.
23
5. PROGRAMMING
To program operation of the automated system, you have to access the " Programming is split into two parts:
5.1. BASIC PROGRAMMING
To access BASIC PROGRAMMING, press key F:
•if you press it (and hold it down), the display shows the name of the first function.
•if you release the key, the display shows the value of the function that can be modified with keys + and -.
•if you press F again (and hold it down), the display shows the name of the next function, etc.
•when you reach the last function, press F to exit the program, and the display resumes showing the gate status.
The following table shows the sequence of functions accessible in BASIC PROGRAMMING:
PROGRAMMING
" mode.
BASIC
and
ADVANCED
.
5.2. ADVANCED PROGRAMMING
To access ADVANCED PROGRAMMING, press key F and, as you hold it down, press key
•if you release key + , the display indicates the name of the first function.
•if you release key F too, the display shows the value of the function that can be modified with keys + and -.
•if you press key F (and hold it down), the display shows the name of the next function, and if you release it, the value that can be modified with keys + and - is shown.
•when you reach the last function, press F to exit the program, and the display resumes showing the gate status.
The following table shows the sequence of functions accessible in ADVANCED PROGRAMMING:
+:
BASIC PROGRAMMING
Display Function Default
FUNCTION LOGICS (see table of logics):
= Automatic
= "Stepped" automatic = "Safety" Automatic = Semi-automatic
= "Stepped" Semi-automatic = Dead-man = "B" Semi-automatic
= Mixed Log. (B opening / C closing)
PAUSE TIME:
This has effect only if the automatic logic was selected. Adjustable from sec. in one-second steps. Subsequently, display changes to minutes and tens of seconds (separated by a point) and time is adjusted in 10-second steps, up to the maximum value of minutes.
E.g. if the display shows , pause time is 2 min. and 50 sec.
FORCE:
Adjusts Motor thrust.
= minimum force
= maximum force
OPENING DIRECTION:
Indicates the gate opening movement and makes it possible not to change the motor and limit­switches connections on the terminal board.
= Right-hand opening movement = Left-hand opening movement
STATUS OF AUTOMATED SYSTEM:
Exit from programming, save data, and return to gate status viewing.
= Closed
= Now opening
= At "STOP"
= Open
= Pause
= "FAIL SAFE" tripped
= Now closing
= Now reversing
= Photocells tripped
F
to
ADVANCED PROGRAMMING
Display Function Default
MAXIMUM TORQUE AT INITIAL THRUST:
The motor operate at maximum torque (ignoring the torque setting) at start of movement. Useful for heavy leaves.
= Active
= Disabled
FINAL BRAKING:
When the gate engages the opening or closing limit-switch, a braking stroke can be selected to ensure the leaf is stopped immediately. If decelerations are selected, braking starts when they finish. At value, braking is disabled. Time can be adjusted from to in
0.01-second steps.
= Braking disabled
from
FAIL SAFE:
If this function is activated, it enables a function test of the photocells before any gate movement. If the test fails (photocells not serviceable signalled by value on the display), the gate does not start moving.
= Active
PRE-FLASHING (5 s):
Activates the flashing lamp for 5 seconds before start of movement.
to = Timed braking
= Disabled
= Disabled = Only before opening
= Only before closing
= Before every movement
F
+
+
24
Display Function Default Display Function Default
INDICATOR-LIGHT:
If is selected, the output functions as a standard indicator-light (lighted at opening and pause, flashing at closing, and off when gate closed). Courtesy light: Different figures correspond to timed activation of the output, which can be used (by a relay) to power a courtesy lamp. Time can be adjusted from sec. in 1-second steps, and from to min. in 10-second steps.
Electric lock command and 'traffic lights' functions:
If you press key - from the setting, the command for the closing electric lock is activated; If you press - again, the command for the
closing and opening electric lock is set; if you press the - key again, you can set the 'traffic lights' functions and .
= Standard indicator-light
from to = Timed output.
= electric lock command before
opening movement
= electric lock command before opening and closing movements
= 'traffic lights' function: the output is active in "open" and "open on pause" status and is disabled 3 seconds before the closing manoeuvre starts. Note: there is 3 seconds of pre-flashing before the closing manoeuvre.
= 'traffic lights' function: the output is active only in "closed" status.
Attention: do not exceed the output's maximum load (24Vdc-3W). If necessary, use a relay and a power supply source outside the equipment.
to
ENCODER:
If the encoder is used, you may select its presence. If the encoder is present and enabled, "decelerations" and "partial opening" are controlled by the encoder (see relevant paragraphs). The encoder operates as an anti-crushing device: If the gate strikes an obstacle during opening or closing, the encoder immediately reverses gate leaf movement for 2 seconds. If the encoder operates again during the 2-seconds reversing time, it stops movement (STOP) without commanding any reversing. If no sensor is supplied, the parameter must be set on
. If there is the encoder, adjust the sensitivity of the anti-crushing system, by varying the parameter between (maximum sensitivity) and (minimum sensitivity).
from to = Encoder active and sensitivity adjustment
= Encoder disabled
Pre-limit switch DECELERATION:
You can select gate deceleration before the opening and closing limit-switches have been tripped. Time can be adjusted from to in
0.04-second steps. If an encoder is used, the adjustment is not determined by time but by motor revs, thus obtaining greater deceleration precision.
= Deceleration disabled from to = Deceleration enabled
CLOSING PHOTOCELLS LOGIC:
Select the tripping mode of the closing photocells. They operate for the closing movement only: they stop movement and reverse it when they are released, or they reverse it immediately.
= Reverse on release
= Reverse immediately to opening
OPENING PHOTOCELLS LOGIC:
Select the tripping mode of the opening photocells. They operate for the opening movement only: they stop the movement and restart it when they are released, or they reverse it immediately.
= Reverse immediately to closing
= Restart movement on release
Post-limit switch DECELERATION:
You can select gate deceleration after the opening and closing limit-switches have been tripped.
Time can be adjusted from to in
0.02-second steps. If an encoder is used, the adjustment is not determined by time but by motor revs, thus obtaining greater deceleration precision.
= Deceleration disabled from to = Deceleration enabled
PARTIAL OPENING:
You can adjust the width of partial leaf opening. Time can be adjusted from to in 1-second steps. If an encoder is used, the adjustment is not determined by time but by motor revs, thus obtaining greater partial-opening precision. For example, with pinion Z20, partial opening can vary from about 60 cm to 4 m.
25
Display Function Default
WORK TIME (time-out):
We advise you to set a value of 5 to 10 seconds over the time taken by the gate to travel from the closing limit-switch to the opening limit-switch and vice versa. Adjustable from to sec. in one­second steps. Subsequently, display changes to minutes and tens of seconds (separated by a point) and time is adjusted in 10 second steps, up to a maximum value of minutes.
Attention: the set value does not exactly matchthe motor's maximum operating time, because the latter is modified according to the performed deceleration spaces.
ASSISTANCE REQUEST (combined with next function):
If activated, at the end of countdown (settable with the next function i.e. "Cycle programming") it effects 2 sec. (in addition to the value already set with the PF function) of pre-flashing at every Open pulse (job request). Can be useful for setting scheduled maintenance jobs.
= Active
= Disabled
CYCLE PROGRAMMING:
For setting countdown of system operation cycles. Settable (in thousands) from to
thousand cycles. The displayed value is updated as cycles proceed. This function can be used to check use of the board or to exploit the "Assistance request".
6. START-UP
6.1. INPUTS CHECK
The table below shows the status of the LEDs in relation to to the status of the inputs. Note the following:
Check the status of the LEDs as per Table.
Operation of the signalling status LEDs
LEDS LIGHTED OFF
FCA Limit-switch free Limit-switch engaged FCC Limit-switch free Limit-switch engaged OPEN B Command activated Command inactive OPEN A Command activated Command inactive FSW OP Safety devices disengaged Safety devices engaged FSW CL Safety devices disengaged Safety devices engaged STOP Command inactive Command activated EDGE Safety devices disengaged Safety devices engaged
LED
LIGHTED
LED
= closed contact
OFF
= open contact
NB.:
• The status of the LEDs while the gate is closed at rest are shown in bold.
7. FINAL OPERATIONS
At end of programming, run a few complete cycles to check if the automated system and the accessories connected to it are operating correctly, giving special attention to safety devices, operator thrust force adjustment, and to the anti-crushing device (Encoder sensor, optional). Hand over the "User's guide" page (in the operator instructions) to the customer, and describe how the system works, as well as the operator release and locking operations indicated in the said guide.
GATE STATUS:
Exit from programming, data saving, and return to viewing gate status (see par. 5.1.).
NB.: modification of programming parameters comes into effect immediately, whereas definitive memory storage occurs only when you exit programming and return to gate status viewing. If the equipment is powered down before return to status viewing, all modifications will be lost. To restore the default settings of the programming disconnect terminal strip J1, press the three buttons +, -, F simultaneously and keep them pressed for 5 seconds.
26
)2("2rofnepootsesreveR
)1(emitesuapsdaoleR
)2("2rofesolcotsesreveR
)delbasidNEPO(
)2("2rofnepootsesreveR
)2("2rofesolcotsesreveR
emitesuapsdaoleR
)delbasidNEPO(
)2("2rofnepootsesreveR
)1(emitesuapsdaoleR
)2("2rofesolcotsesreveR
)delbasidNEPO(
)2("2rofnepootsesreveR
)2("2rofesolcotsesreveR
)delbasidNEPO(
tceffeoN
otsesrever,esaelerno,dnaskcoL
)1(emitesuapsdaoleR
)delbasidNEPO(
nepo
)3()1(emitesuapsdaoleR
.2.5hpargarapees
tceffeoN
)delbasidANEPO.gnpo.trapnofi(
)NEPOsevas(
tceffeoN
tceffeoN
)delbasidNEPO(
tceffeoN
seunitnoc,esaelerno,dnaskcoL
gninepo
tceffeoN
)delbasidNEPO(
tceffeoN
otsesrever,esaelerno,dnaskcoL
emitesuapsdaoleR
)delbasidNEPO(
nepo
)3(emitesuapsdaoleR
.2.5hpargarapees
)delbasidNEPO(
tceffeoN
)delbasidANEPO.gnpo.trapnofi(
)NEPOsevas(
tceffeoN
tceffeoN
)delbasidNEPO(
tceffeoN
seunitnoc,esaelerno,dnaskcoL
gninepo
tceffeoN
)delbasidNEPO(
tceffeoN
otsesrever,esaelerno,dnaskcoL
"5retfasesolc,esaelernO
)delbasidNEPO(
nepo
NEPO("5retfasesolc,esaelernO
.2.5hpargarapees
)3()delbasid
tceffeoN
)delbasidANEPO.gnpo.trapnofi(
)NEPOsevas(
tceffeoN
tceffeoN
)delbasidNEPO
tceffeoN
seunitnoc,esaelerno,dnaskcoL
gninepo
)NEPOsevas(
tceffeoN
tceffeoN
)delbasidNEPO(
)delbasidNEPO(
tceffeoN
tceffeoN
otsesrever,esaelerno,dnaskcoL
nepo
.2.5hpargarapees
)delbasidNEPO(
)3(tceffeoN
tceffeoN
)delbasidANEPO.gnpo.trapnofi(
)NEPOsevas(
tceffeoN
tceffeoN
)delbasidNEPO(
tceffeoN
seunitnoc,esaelerno,dnaskcoL
gninepo
tceffeoN
)delbasidNEPO(
tceffeoN
)delbasidNEPO(
tceffeoN
noitarepo
spotS
retfasesolcdnaemitgninepo
laitrapehtroffaelsnepO
)1(emitesuap
)1(yletaidemmifaelehtsnepo-eR
)3()1(emitesuapsdaoleR
)3(faelehtsesolC
)3()1(tceffeoN .2.5hpargarapeestceffeoN
sesolcdnafaelehtsnepO
)1(emitesuapretfati
)delbasidNEPO(
tceffeoN
)delbasidNEPO(
tceffeoN
noitarepo
spotS
retfasesolcdnaemitgninepo
laitrapehtroffaelsnepO
emitesuap
)3(noitarepospotS
sesolcdnafaelehtsnepO
emitesuapretfati
,degagnesecivedytefaSgnisolChtiw(faelehtsesolC
yletaidemmifaelehtsnepo-eR
)3()eslupdn2ehttasnepo
)3(noitarepospotS .2.5hpargarapeestceffeoN
)delbasidNEPO(
tceffeoN
)delbasidNEPO(
tceffeoN
noitarepo
spotS
retfasesolcdnaemitgninepo
laitrapehtroffaelsnepO
emitesuap
)3(yletaidemmifaelehtsesolc-eR
sesolcdnafaelehtsnepO
emitesuapretfati
)3(yletaidemmifaelehtsesolc-eR .2.5hpargarapees
yletaidemmifaelehtsnepo-eR
)3(faelehtsesolC
)delbasidNEPO(
tceffeoN
)delbasidNEPO(
tceffeoN
noitarepo
spotS
laitrapehtroffaelsnepO
emitgninepo
)3(yletaidemmifaelehtsesolc-eR
faelehtsnepO
,degagnesecivedytefaSgnisolChtiw(faelehtsesolC
yletaidemmifaelehtsnepo-eR
)3()eslupdn2ehttasnepo
)3(noitarepospotS .2.5hpargarapeestceffeoN
SUTATSETAGA-NEPOB-NEPOPOTSSECIVEDYTEFASGNINEPOSECIVEDYTEFASGNISOLCECIVEDYTEFASLC/POECIVEDYTEFASEGDE
"A"cigoL SESLUP
Tab. 3/a
ESUAPnoNEPO
GNINEPO
DESOLC
GNISOLC
DEKCOL
SUTATSETAGA-NEPOB-NEPOPOTSSECIVEDYTEFASGNINEPOSECIVEDYTEFASGNISOLCECIVEDYTEFASLC/POECIVEDYTEFASEGDE
"PA"cigoL SESLUP
Tab. 3/b
ESUAPnoNEPO
GNINEPO
DESOLC
GNISOLC
DEKCOL
SUTATSETAGA-NEPOB-NEPOPOTSSECIVEDYTEFASGNINEPOSECIVEDYTEFASGNISOLCECIVEDYTEFASLC/POECIVEDYTEFASEGDE
"S"cigoL SESLUP
Tab. 3/c
ESUAPnoNEPO
GNINEPO
DESOLC
GNISOLC
DEKCOL
SUTATSETAGA-NEPOB-NEPOPOTSSECIVEDYTEFASGNINEPOSECIVEDYTEFASGNISOLCECIVEDYTEFASLC/POECIVEDYTEFASEGDE
"E"cigoL SESLUP
DESOLC
NEPO
GNINEPO
GNISOLC
DEKCOL
Tab. 3/d
27
)2("2rofnepootsesreveR
)2("2rofesolcotsesreveR
)2("2rofnepootsesreveR
)delbasidB/A-NEPO(
)2("2rofnepootsesreveR
)delbasidB/A-NEPO(
)2("2rofnepootsesreveR
)delbasidB/A-NEPO(
tceffeoN
)delbasidNEPO(tceffeoN
)delbasidANEPO(
tceffeoN
seunitnoc,esaelerno,dnaskcoL
otsesrever,esaelerno,dnaskcoL
)delbasidB/A-NEPO(
)delbasidBNEPO(
noitarepospotS
gninepo
nepo
)3()delbasidNEPO(tceffeoN )delbasidNEPO(tceffeoN
tceffeoN )delbasidNEPO(tceffeoN
)NEPOselbasidti,esolctsumtifi(
tceffeoN
tceffeoN
)delbasidBNEPO(
)delbasidB-NEPO(
noitarepospotS
tceffeoN
tceffeoN
tceffeoN )2("2rofesolcotsesreveR
tceffeoN
)delbasidANEPO(
tceffeoN
)delbasidBNEPO(
tceffeoN
)delbasidB-NEPO(
)delbasidBNEPO(
noitarepospotS
tceffeoN
tceffeoN
)delbasidB/ANEPO(
tceffeoN
)delbasidB/A-NEPO(
noitarepospotS
)delbasidBNEPO(
tceffeoN
tceffeoN )2("2rofesolcotsesreveR
tceffeoN
)delbasidANEPO(
tceffeoN
)delbasidBNEPO(
noitarepospotS
tceffeoN
)delbasidB-NEPO(
)delbasidBNEPO(
noitarepospotS
tceffeoN
tceffeoN
)delbasidB/ANEPO(
tceffeoN
)delbasidB/A-NEPO(
)delbasidBNEPO(
tceffeoN
tceffeoN )2("2rofesolcotsesreveR
ANEPO.gnpo.trapnofi(tceffeoN
)delbasid
)delbasidNEPO(
tceffeoN
noitarepo
spotS
laitrapehtroffaelsnepO
emitgninepo
)3(yletaidemmifaelehtsesolc-eR
noitarepospotS )NEPOsevas(tceffeoN.2.5hpargarapees
)NEPOselbasidti,nepotsumtifi(
)delbasidA-NEPO(
)delbasidANEPO(
tceffeoN
)delbasidNEPO(
tceffeoN
)3(noitceridesrevernitnemevomstratseR
)potSaretfasesolcsyawla(
)3(noitarepospotS .2.5hpargarapeestceffeoN
tceffeoN
)delbasidANEPO(
tceffeoN
)delbasidB/A-NEPO(
tceffeoN
)delbasidA-NEPO(
faelehtsesolC
tceffeoN
)delbasidA-NEPO(
noitarepospotS
tceffeoN
noitarepospotS
tceffeoN
)delbasidANEPO(
tceffeoN
NEPO(tceffeoN
)delbasidB
)delbasidA-NEPO(
)ANEPOsevas(
noitarepospotS
tceffeoN
tceffeoN
)delbasidANEPO(
tceffeoN
)delbasidB/ANEPO(
tceffeoN
noitarepo
spotS
)ANEPOsevas(
tceffeoN
tceffeoN
)delbasidBNEPO(
tceffeoN
spotS
)delbasidA-NEPO(
)delbasidA-NEPO(
noitarepospotS
tceffeoN
NEPO(tceffeoN
)delbasidB/A
noitarepo
SUTATSETAGA-NEPOB-NEPOPOTSSECIVEDYTEFASGNINEPOSECIVEDYTEFASGNISOLCECIVEDYTEFASLC/POECIVEDYTEFASEGDE
"PE"cigoL SESLUP
Tab. 3/e
)delbasidB-NEPO(
faelehtsnepO
GNINEPO
DESOLC
GNISOLC
NEPO
DEKCOL
Tab. 3/f
faelehtsnepO
SUTATSETAG)gninepo(A-NEPO)gnisolc(B-NEPOPOTSSECIVEDYTEFASGNINEPOSECIVEDYTEFASGNISOLCECIVEDYTEFASLC/POECIVEDYTEFASEGDE
"C"cigoLNWODDLEHSYAWLASLORTNOC SESLUP
DESOLC
noitarepospotS/
tceffeoN
/noitarepospotS
GNINEPO
GNISOLC
NEPO
Tab. 3/g
faelehtsnepOtceffeoN
SUTATSETAG)gninepo(A-NEPO)gnisolc(B-NEPOPOTSSECIVEDYTEFASGNINEPOSECIVEDYTEFASGNISOLCECIVEDYTEFASLC/POECIVEDYTEFASEGDE
"B"cigoL SESLUP
DESOLC
nepootsesreveRtceffeoN
tceffeoNfaelehtsesolC
GNISOLC
NEPO
faelehtsnepOfaelehtsesolC
tceffeoNtceffeoN
GNINEPO
DEKCOL
faelehtsnepOtceffeoN
"C/B"cigoLSLORTNOCNUROTDLOHGNISOLC/ESLUPGNINEPO SESLUP
SUTATSETAG)gninepo(A-NEPO)gnisolc(B-NEPOPOTSSECIVEDYTEFASGNINEPOSECIVEDYTEFASGNISOLCECIVEDYTEFASLC/POECIVEDYTEFASEGDE
DESOLC
Tab. 3/h
nepootsesreveRtceffeoN
tceffeoNfaelehtsesolC
GNISOLC
NEPO
faelehtsnepOfaelehtsesolC
tceffeoNtceffeoN
GNINEPO
DEKCOL
(1) If maintained, it prolongs the pause until disabled by the command (timer function) (3) During the partial opening cycle, an OPEN A pulse causes total opening.
(2) If a new pulse occurs within 2 seconds after reversing, it immediately stops operation. NB.: Effects on other active pulse inputs in brackets.
28
Users guide
3
2
1
Fig.01 Fig.02
AUTOMATED SYSTEM 740-741
Read the instructions carefully before using the product and keep them for future consultation.
GENERAL SAFETY RULES
If installed and used correctly, the 740-741 automated system will ensure a high degree of safety. Some simple rules regarding behaviour will avoid any accidental trouble:
• Do not stand near the automated system and do not allow children and other people or things to stand there, especially while it is operating.
• Keep radiocontrols or any other pulse generator well away from children to prevent the automated system from being activated involuntarily.
• Do not allow children to play with the automated system.
• Do not willingly obstruct gate movement.
• Prevent any branches or shrubs from interfering with gate movement.
• Keep light signalling systems efficient and clearly visible.
• Do not attempt to activate the gate by hand unless you have released it.
• In the event of malfunctions, release the gate to allow access and wait for qualified technical personnel to do the necessary work.
• After enabling manual operation, switch off the power supply to the system before restoring normal operation.
• Do not make any alterations to the components of the automated system.
• Do not attempt any kind of repair of direct action whatsoever and contact qualified personnel only.
• Call in qualified personnel at least every 6 months to check the efficiency of the automated system, safety devices and earth connection.
DESCRIPTION
The 740-741 automated system is ideal for controlling vehicle access areas of medium transit frequency. The 740-741 automated system for sliding gates is an electro­mechanical operator transmitting motion to the sliding gate via a rack pinion or chain appropriately coupled to the gate. Operation of the sliding gate is controlled by an electronic control unit housed inside the operator or in a hermetically sealed outdoor enclosure. When, with the gate closed, the unit receives an opening command by radiocontrol or from another suitable device, it activates the motor until the opening position is reached. If automatic operation was set, the gate re-closes automatically after the selected pause time has elapsed. If the semi-automatic operation was set, a second pulse must be sent to close the gate again. An opening pulse during re-closing, always causes movement to be reversed. A stop pulse (if provided) always stops movement. The light signalling indicates that the gate is currently moving. For details on sliding gate behaviour in different function logics, consult the installation technician. The automated systems include obstacle-detection and/or safety devices (photocells, edges) that prevent the gate from closing when
1
2
3
there is an obstacle in the area they protect. The system ensures mechanical locking when the motor is not operating and, therefore, it is not necessary to install any lock. Manual opening is, therefore, only possible by using the release system. The gearmotor does not have a mechanical clutch and, therefore, it is coupled to a unit with an electronic clutch offering the necessary anti-crushing safety if the system is completed with the necessary safety devices. A convenient manual release with customised key makes it possible to move the gate in the event of a power failure or malfunction.
MANUAL OPERATION
Warning: Cut power to the system to prevent an involuntary pulse
from activating the gate during the release manoeuvre
To release the operator proceed as follows:
1) Insert the key provided and turn it clockwise as shown in Fig. 01 ref. 1 and 2.
2) Turn the release system clockwise, until the mechanical stop is reached, Fig. 01 ref. 3.
3) Open and close the gate manually.
RESTORING NORMAL OPERATION
Warning: Cut power to the system to prevent an involuntary pulse
from activating the gate during the manoeuvre for restoring normal operation.
To restore normal operation proceed as follows:
1) Turn the release system anti-clockwise, until its stop is reached, Fig. 02 ref. 1.
2) Turn the key anti-clockwise and remove it from the lock, Fig. 02 ref. 2 and 3.
3) Move the gate until the release system meshes (corresponds to gate locking).
4) Power up the system.
MAINTENANCE
To ensure trouble-free operation and a constant safety level, an overall check of the system should be carried out every 6 months. A form for recording routine maintenance operations is enclosed.
REPAIRS
For any repairs, contact the authorised Repair Centres.
AVAILABLE ACCESSORIES
Refer to catalogue for available accessories.
Le descrizioni e le illustrazioni del presente manuale non sono impegnative. La FAAC si riserva il diritto, lasciando inalterate le caratteristiche essenziali dell’apparecchiatura, di apportare in qualunque momento e senza impegnarsi ad aggiornare la presente pubblicazione, le modifiche che essa ritiene convenienti per miglioramenti tecnici o per qualsiasi altra esigenza di carattere costruttivo o commerciale.
The descriptions and illustrations contained in the present manual are not binding. FAAC reserves the right, whilst leaving the main features of the equipments unaltered, to undertake any modifications it holds necessary for either technical or commercial reasons, at any time and without revising the present publication.
Les descriptions et les illustrations du présent manuel sont fournies à titre indicatif. FAAC se réserve le droit d’apporter à tout moment les modifications qu’elle jugera utiles sur ce produit tout en conservant les caractéristiques essentielles, sans devoir pour autant mettre à jour cette publication.
Die Beschreibungen und Abbildungen in vorliegendem Handbuch sind unverbindlich. FAAC behält sich das Recht vor, ohne die wesentlichen Eigenschaften dieses Gerätes zu verändern und ohne Verbindlichkeiten in Bezug auf die Neufassung der vorliegenden Anleitungen, technisch bzw. konstruktiv/kommerziell bedingte Verbesserungen vorzunehmen.
voor de natuur
100% kringlooppapier
Las descripciones y las ilustraciones de este manual no comportan compromiso alguno. FAAC se reserva el derecho, dejando inmutadas las características esenciales de los aparatos, de aportar, en cualquier momento y sin comprometerse a poner al día la presente publicación, todas las modificaciones que considere oportunas para el perfeccionamiento técnico o para cualquier otro tipo de exigencia de carácter constructivo o comercial.
De beschrijvingen in deze handleiding zijn niet bindend. FAAC behoudt zich het recht voor op elk willekeurig moment de veranderingen aan te brengen die het bedrijf nuttig acht met het oog op technische verbeteringen of alle mogelijke andere productie- of commerciële eisen, waarbij de fundamentele eigenschappen van de apparaat gehandhaafd blijven, zonder zich daardoor te verplichten deze publicatie bij te werken.
FAAC per la natura
• La presente istruzione è realizzata al 100% in carta riciclata.
• Non disperdete nell'ambiente gli imballaggi dei componenti dell'automazione bensì selezionate i vari materiali (es. cartone, polistirolo) secondo prescrizioni locali per lo smaltimento rifiuti e le norme vigenti.
FAAC for the environment
• The present manual is produced in 100% recycled paper
• Respect the environment. Dispose of each type of product packaging material (card, polystyrene) in accordance with the provisions for waste disposal as specified in the country of installation.
FAAC écologique
• La présente notice a été réalisée 100% avec du papier recyclé.
• Ne pas jeter dans la nature les emballages des composants de l’automatisme, mais sélectionner les différents matériaux (ex.: carton, polystyrène) selon la législation locale pour l’élimination des déchets et les normes en vigueur.
FAAC der Umwelt zuliebe
• Vorliegende Anleitungen sind auf 100% Altpapier gedruckt.
• Verpackungsstoffe der Antriebskomponenten (z.B. Pappe, Styropor) nach den einschlägigen Normen der Abfallwirtschaft sortenrein sammeln.
FAAC por la naturaleza.
• El presente manual de instrucciones se ha realizado, al 100%, en papel reciclado.
• Los materiales utilizados para el embalaje de las distintas partes del sistema automático (cartón, poliestireno) no deben tirarse al medio ambiente, sino seleccionarse conforme a las prescripciones locales y las normas vigentes para el desecho de residuos sólidos.
FAAC voor de natuur
• Deze gebruiksaanwijzing is gedrukt op 100% kringlooppapier.
• Laat de verpakkingen van de componenten van het automatische systeem niet in het milieu achter, maar scheidt de verschillende materialen (b.v. karton, polystyreen) volgens de plaatselijke voorschriften op de afvalverwerkingen en de geldende normen.
100% papel reciclado
ist umweltfreundlich
100% Altpapier
pour la nature
papier recyclé 100%
FAAC S.p.A.
Via Benini, 1 40069 Zola Predosa (BO) - ITALIA Tel.: 051/61724 - Fax: 051/758518 www.faacgroup.com
Timbro del Rivenditore:/Distributor’s Stamp:/Timbre de l’Agent:/ Fachhändlerstempel:/Sello del Revendedor:/Stempel van de dealer:
for nature
recycled paper 100%
per la natura
carta riciclata 100%
732484 - Rev. B -
Loading...