Installation should be performed by a professional installer.
R
equired welding should be performed by a qualified welder.
Should electricity be required, use a cer
tified electrician only.
Any device that requires 120 Volts AC should be U.L. approved.
Review with
the owner all safety concerns including:
Do not operate the gate unless area around gate is in full view.
Never let children operate or play with gate controls. Keep the remote control
away from children.
Always keep people and objects away from the gate. NO ONE SHOULD CROSS
THE PATH OF THE MOVING GATE.
Periodically test the obstruction sensitivity to assure safe and proper
operation. Do not test sensitiv
ity by standing between the gate and the hinge or
stop post.
The “CAUTION AUTOMATIC GATE” signs should be clearly visible from both
sides of the gate.
Always insure that the gate has closed securely before leaving area.
Arrange with local fire and law enforcement for emergency access.
Use the emergency release only whe
n the gate is not moving.
A secondary entrapment device such as loop detectors, edge switches, and b
eam
detectors are highly recommended and required to meet the UL325 standard.
Install control devices
such as keypads far enough away (5 feet or further) from any
moving parts of the operator and gate to
prevent possible injury.
Do not install control box where the gate can come in contact with person
using the
push button on side of control box.
Always disconnect the battery or power source when maki
ng adjustments or repairs to
any part of the gate or operator.
All rollers should be covered to preve
nt injury.
KEEP GATES PROPERLY MAINTAINED. Read the owner’s manual. Have a qualified
service person m
ake repairs to gate hardware.
The entrance is for vehicles only. Pedestrians must use separate entra
nce.
Test the gate operator monthly. The gate MUST reverse on contact with a rigid object or
stop when
an object activates the non contact sensors. After adjusting the force or limit of
travel, retest the
gate operator. Failure to adjust and retest the gate operator properly can
increase the risk of injury
or death.
SAVE THESE INSTRUCTIONS.
IMPORTANT SAFETY INSTRUCTIONS
WARNING - To reduce the risk of injury or death:
3
APPLICATIONS
Low voltage virtually eliminates risk of electrical shock.
Battery powered operators provide up to 200 operations in the event of
power outages.
The battery may be recharged with a trickle charger or by solar energy
(Electrical battery chargers sh
ould have a class 2 transformer rating).
If a trickle charger is used and a standard electrical outlet
is not readily available, a
licensed electrician will be required for proper electrical hook up.
The f
ollowing table should be used as a guide for capacity of operation of operators
only, additional optio
ns may reduce the the daily usage. Please note that the charge
capability of solar panels will vary wit
h different geographical locations.
The Apollo Model 7200ETL Slide Gate Operator is designed to handle a slide gate
up to 32 feet in total length (accomodates a 30 foot drive) and 1,000 Lbs. A
professional fence or gate dealer is recommended to assure proper installation.
Apollo Gate Operators are available only through qualified dealers with an
outstanding reputation in the fence and gate industry. These dealers will be able to
recommend the proper equipment for particular applications. Apollo GateOperators are 12 Volt DC (Direct Current) powered. A 12 Volt sealed battery (33
ampere hour minimum) is recommended. There are several advantages with 12 Volt
DC systems:
5 watt solar panel
10 watt solar panel
20 watt solar panel (requires 5310 regulator)
30 watt solar panel (requires 5310 regulator)
40 watt solar panel (requires 5310 regulator)
1.5 amp battery charger
10 amp battery charger
Daily Cycles1-10 1-20 1-40 1-601-80 80+
*
*
*
*
*
*
*
Note: Double the amount of solar panels for Dual Gate Operators.
4
PRE-INSTALLATION CHECKLIST
The following checklist should be used before beginning installation:
Verify that the proper operator has been selected for this application.
Verify proper installation and operation of the gate.
1. Are all rollers covered with a protective housing?
2. Are the rollers servicable?
3. Does the gate roll free and level?
4. Will the gate require a locking device?
5. Are the main posts sturdy enough to handle the gate & operator?
Determine the general location of the operator, chian brackets, and solar
panel (if used).
1. Is there a suitable location for the operator?
2.Can the solar panel (if used) be mounted in an unobstructed area facing
south?
3. Will additional solar panel cable be required?
4. Is electricity available (if required)?
Consider safety and access options. Recommend if needed.
1. Will there be chidren or animals in the area?
2. Are safety loops, edge switches, or photo beam detectors required?
3. How can the gate be opened in emergencies?
4. How will visitors enter and exit?
5. Will vehicles (and trailers) have sufficient room off roadway to operate any
control devices such as keypads?
5
PARTS IDENTIFICATION
Chain Brackets (2)
Operator
Chain Bolts with hardware (2 each)
Master Chain Links (2 each)
5/16” x 2” U Bolts (4 each)
Tie Wraps (4 each)
5/16 Washers, Lock Washers, &
Nuts (16 each)
5/16” x 3” U Bolts (4 each)
#40 Roller Chain (35 feet)
#201
5 Watt Solar Panel & Bracket
(optional)
#404C
Automatic Battery Charger (optional)
6
#273G
CAUTION Signs (2 each)
OPERATOR INSTALLATION
STEP 1. Install two 3” dia. Posts parallel to the gate as shown. Posts height depends on height
preference of operator.
Gate
F e n c e
5”
6”
24”
D r i v e w a y
Inside posts
STEP 2. Remove chain cover and front lid. Mount to posts using the four supplied 3” U-bolts
7
STEP 3. Install one of the gate brackets and chain bolts on right side of gate using the supplied
2” U-bolts. Do not tighten at this time.
STEP 4. Attach the chain to the chain bolt using the master chain link.
Note: The height of
the chain bolt should
align with the bottom
teeth of the idler
sprockets.
Adjust the chain bolt to allow for
maximum tightening
8
STEP 5. Thread chain on the sprockets as shown.
T O P
Chain should be
level with about a 1
inch lag per 10 feet.
STEP 6. (Refer to page 8)
Install the other gate bracket and chain bolt on the left side of the gate.
Determine the required length of chain needed to attach to the chain bolt and still allow adjustment.
Using a chain breaking tool (not provided), remove excess chain.
Attach chain to chain bolt.
Tighten all chain brackets and chain bolts. Allow 1 inch of chain lag per 10 feet of chain.
Chain should be aligned with all sprockets.
9
Internal Limit Adjustment
Step 1. Press LED Enable once on the
right side of the circuit board. The STOP
LED should illuminate. This is a standard
condition.
Step 2. Turn switch #1 OFF on the control board
Step 3. Activate the gate until the CLOSED LIMIT
LED is illuminated
Step 4. Adjust the corresponding limit switch for preferred
close position.
Step 5. Repeat steps 3 & 4 for setting the open limit
Limit adjustment for left
movement
(gate moving to the left)
- less travel
- more travel
Limit adjustment for right.
Movement
(gate moving to the right)
- less travel
- more travel
TIP:If the limits require extensive adjustment use a 13/32” or 25/64” socket with a portable drill
for course adjustment, then adjust manually for fine adjustment.
10
Left or Right Hand Operation
Wiring Instructions
STEP 1. Determine which side of driveway operator will be installed on. The factory units are
plugged into INPUT B
for right side installation as shown in Fig. 1.
Red
Black
Green
Orange
White
For left side installation, disconnect from INPUT B and plug into INPUT A
board as shown in Fig. 2.
Right Side Installation
Black
Green
Orange
White
Left Side Installation
Red
on the surge
Fig. 1
Right Side Installation
Gate in closed position
operator
Fig. 2
Left Side Installation
Gate in closed position
operator
11
QUICK RELEASE OPERATION
Engaged
Engaged
Pull & turn 1/2 inch to disengage
12
STEP 7Programming Current Sensing
The 835/836 control boards incorporate a safety feature that will put the operator into a hard shutdown mode if the control board detects a current sense
two consecutive times during a cycle. This hard shutdown condition can only
be reset by shorting the FIREBOX or UL connectors on the left side of the
control board to ground. This condition may also be reset by pressing the
HARD SHUTDOWN RESET button located toward the upper right hand corner of the control board. If a firebox is used in the installation, The firebox
door (optional) should be opened and closed to reset the control board.
The following instructions must be followed at installation for proper safety assurance.
All limits should be set before beginning this procedure.
This new procedure applies to revision 31 or higher firmware.
1. Press and hold the LED ENABLE button for five seconds. The STOP LED will blink
indicating that the board is in learn mode.
3. Cycle gate for 3 full cycles. The STOP LED will stop blinking indicating that the board
is now ready for normal operation
4. Test the auto reverse sensitivity to ensure maximum safety protection. The current
sensitivity adjustment pot may be adjusted to decrease or increase sensitivity.
COUNTER CLOCKWISE
More sensitivity
Gate is easy to current
sense
CLOCKWISE
Less sensitivity
Gate is harder to
current sense
8. Refer to the 835/836 Operator Control Board Manual to set other options such as
program switch options and close timer adjustments.
Installation is now complete.
Note: Program switch #9 is no longer functional and the current sense may be readjusted
at any time.
13
835/836 Control Board Parts Identification
Program Switches
Operate Push Button
Optional Device Inputs
Timer To Close-
Dual Gate Delay -
Current Sensitivity -
Adjustments
Microprocessor
GateLink Connector
Hard Shutdown Reset
Remote Monitor Outputs
and Photo Eye
LED Enable & Learn
Mode Push Button
Stop Circuit Jumper
Fire & ETL Inputs
Emergency Bypass
Actuator Connector
(Slave)
Rever se Battery Polarity
Indicators
14
Control Board Reset
Optional Device Input
Actuator Connector
(Master)
Actuator Connector
7
5
3
1
8
6
4
2
Board ActuatorFunction
Cable
Pin 1OrangeOpen Limit
Pin 2WhiteClose Limit
Pin 3BlackMotor (positive on open, negative on close)
Pin 4RedMotor (negative on open, positive on close)
Pin 5GreenCommon for both limit switches
Pin 6YellowFeedback from intelligent actuator(816E/816EX)
Pin 7BlackBattery Negative
Pin 8RedBattery Positive
EMERGENCY BYPASS (open only)
Applies battery voltage directly to motor to open gate if
control board fails. User must unplug before gate opens
to maximum travel or 15 amp fuse will open. Fuse
should be checked before returning gate to service.
Remote Outputs and Photo Eye Hookup
12VSupplied battery voltage
MASMaster Operator Indicator (indicates master side of gate is closed)
+12V when on closed limit. Ground when off of closed limit.
SLVSlave Operator Indicator (indicates slave side of gate is closed)
+12V when on closed limit. Ground when off of closed limit.
GNDBattery supplied ground
SIREN Connect to siren +
applies +12V when gate(s) are running, or in hard shutdown
GNDBattery supplied ground
LOCKConnect to lock + (optional) Magnetic or Solenoid type locks (Dip Switch #6 Selectable)
Photo Eye Hookup
Photo eye / safety loop wiring. Connect the positive power wire of the accessory to
12V. Connect the ground wire of the accessory to MAS (upper right area of the
835/836 board). Connect the relay wires of the accessory as normal: COM to GND.
NO to SAFETY (#14) (for a safety device). When the gate operator begins opening
(comes off of the closed limits) the MAS terminal will become a ground and will
complete the flow of power to the accessory. This will power the accessory up and it
will work as normal until the gate gets closed and the MAS terminal switches and the
device will power down.
15
Adjustments
TIMER TO CL O S EAdjusts time before gate automatically closes
Adjustable 5 to 70 seconds.
DUAL GATE DELAYAdjusts delay between master and slave op-
eration 0-4 seconds (836 only for use with
magnetic, solenoid, and other locking de
vices)
CURRENT SENSITIVITY Increases or decreases the Auto Reverse
sensitivity.
Push Buttons
OPERATEWhen depressed, activates the gate. Used for initial
installation and testing.
Hard Shutdown Reset Resets the operator when the gate current
senses twice before fully opening or closing.
LED ENABLE When depressed, activates LEDs for 15
minutes to assist in installation and troubleshooting.
Hold the push button down for five seconds to put
the board in program mode.
RESETResets the microprocessor. Returns processor to
last known state.
Jumpers
STOP CIRCUIT JUMPERWhen the STOP CIRCUIT
program switch #5 must be ON JUMPER is connected, the gate
will operate normally.
STOP CIRCUIT JUMPERWhen a 3-button station is con-
program switch #5 must be OFFnected to the board, the STOP
CIRCUIT JUMPER must be removed.
16
Program Switches
OFFON
1 TIMER TO CLOSEGate does not automatically close.Gate automatically closes.
2 TIMER TO CLOSE OPT.Gate automatically closes fromGate automatically closes only when completely
any position after opening.open (open limit engaged).
3 SLAVE DISABLEEnables slave side (dual gate use).Disables slave side. (single gate use)
4 SIREN DELAYSiren (optional) active when gate isSiren (optional) starts 5 seconds before gate moves.
moving.
5 ‘STOP’ CIRCUIT ENABLEMust hold down open or closeNormal operation
buttons to move gate. Gate stopsMomentary open or close input runs gate to limit.
when button released.
6 LOCK TYPEFor 12V mechanical (solenoid) locks.For 12V magnetic locks.
(+12V for 4 seconds on open cycle)(+12V when on close limit)
7 COAST ENABLEGate will stop immediately when atGate will coast (minimally) when it reaches limits.
Open or Close limitRecommended for 7500 slide operator only.
8 FREE EXIT OPT.A free exit input will open gate fromA free exit input will open gate from any
closed position or after a close cycleposition after an open or close cycle.
only.
9 DUAL GATE SYNCBoth gates operate at normalThis feature will control the master gate to open
Speed (slave slower thanor close at the same speed as the slave gate.
Master).
10 SMART ACT.Off for 416E & 416EX actuators,Used for 816E & 816EX actuators only
slide gates, 3500 or when slow down(soft start & stop).
feature is not desired.
17
Optional Device Inputs
GNDSupplied Battery Ground
INPActivate Gate (Push button activation when momentarily shorted to ground)
12VSupplied Battery Voltage (Protected with 3 Amp fuse)
GNDSupplied Battery Ground
INPActivate Gate (Push button activation when momentarily shorted to ground)
12VSupplied Battery Voltage (Protected with 3 Amp fuse)
EDGEReverse edge input. When grounded, will stop and reverse gate if closing, resets close timer if gate is open.
EDGEReverse edge input. When grounded, will stop and reverse gate if closing, resets close timer if gate is open.
GNDSupplied Battery Ground
GNDSupplied Battery Ground
STOPStop input from a 3 button station (must remove STOP CIRCUIT JUMPER) Normally closed
CLOSE Close input from a 3 button station (see program switch #5 for options)
OPENOpen input from a 3 button station (see program switch #5 for options)
GNDSupplied Battery Ground
GNDSupplied Battery Ground
FREE EXIT Opens gate if closed, stops and reverses gate if closing, resets close timer if gate is open.
GNDSupplied Battery Ground
SHADOW Resets close timer when gate is open (also referred to as under gate loop)
GNDSupplied Battery Ground
SAFETY Resets close timer if gate is open, stops and reverses if gate is closing. (Does not open a closed gate)
GNDSupplied Battery Ground
FIREWhen grounded, opens gate and holds gate open until released.
Clears “Hard Shutdown” mode of software.
ULWhen grounded, opens gate and holds gate open until released.
Clears “Hard Shutdown” mode of software.
GNDSupplied Battery Ground
INPActivate Gate (Push button activation when momentarily shorted to ground)
12VSupplied Battery Voltage (Protected with 3 Amp fuse)
18
APOLLO
Gate Operators, Inc.
911 Siren
The 911 Siren is included with all Apollo ETL Gate Operators.
Mount siren in an area that will produce maximum performance (additional wire may be required).
Connect the red wire to the SIREN connector on the Remote Monitor Output Connector block.
Connect the black wire to the GND connector on the Remote Monitor Output Connector block.
Red
Black
Set Program Switch # 4 as preferred:
ON - Upon activation, Siren will start for 5 seconds before gate(s) begin moving.
OFF - Siren and gate(s) start immediately upon activation.
19
APOLLO
Gate Operators
RECEIVER OPTIONS
Do not confuse the receiver code switches with the red program switches on the gate control board.
Never set all code switches to the same position. Transmitters must match code switches for proper operation.
If power is taken directly from battery or connected as shown below, receiver should be configured for 12VDC
Multi-Code/Digi-Code
Allstar
Lift-Master*
Heddolf
black
gray
gray
red
white
black
red
1
2
3
4
black
white
yellow
red
Linear
white/silver
common
n/o
white/gold
* Lift-Master will require that the 12/24 jumper be set to 12 and the C/M (constant/momentary) jumper be set to C
20
TROUBLESHOOTING
The Apollo 835/836 board is the standard board in all ETL compliant Apollo Gate Operators. Single gate systems use the 835 board (distinguished by MASTER and EMERGENCY BYPASS modular receptacles) and DUAL gate systems use the 836 board
(distinguished by MASTER, SLAVE and EMERGENCY BYPASS receptacles). The 836
board may be used in single gate applications by simply turning PROGRAM SWITCH #3
to the OFF position and only using the MASTER receptacle of the board. Apollo 7000
ETL and 7100 ETL systems use a Stature Electric direct current motor while the Commercial 7200 ETL and 7300 ETL use a Bison direct current motor. Both motors are similar in design and thus trouble shooting for all of the slide gate systems is covered in one
manual. Keep in mind that SLIDE GATE operators do NOT utilize the “SMART ACTUATOR” featu re of the 835/836 board s o Progra m switch #10 mu st ALWAYS be in the O FF
position. Trouble Shooting the Apollo 7000/7100/7200/7300 ETL systems:
1.Check your battery! The battery in your gate operator is the power source for the
entire system. If it is not adequately charged, the system will not operator properly.
Test the battery by checking the voltage with a volt-meter while the battery is under load (gate operating). For AC charged systems – unplug the battery charger
before load testing battery. Battery voltage should be 11.5 volt DC or higher while
the operator is running (battery under load).
2.Program Switch Settings: At the upper center of the board there are 10 program
switches. These switches enable and disable certain features of the Apollo system. DEFAULT setting of these switches is as follows: SINGLE GATE – 1,2,3,5
ON (all others OFF) DUAL GATE – 1,2,5 ON (all others OFF)
3.LED ENABLE BUTTON: On the right side of the board – half way down is the LED
ENABLE button. Pressing this button once and releasing it “enables” the LEDs on
the board for approximately 15 minutes. When the LEDs are enabled – the “STOP”
light should always be lit on the left side of the board. Other LEDs may be lit as
well depending on the status of the operator. If the gate(s) are in the OPEN position, the OPEN limit indicator(s) should be lit. If the gate(s) are CLOSED, the
CLOSED limit indicator(s) should be lit. (The OPEN and CLOSED LEDs should
never be on at the same time) Any LEDs that are lit on the left side of the board or
at the lower right corner of the board (except the STOP LED) indicate a TRIGGER
from an accessory device connected at that location. Devices connected where an
LED is lit should be removed before further testing is done. After the system is
made operational – these devices may be reconnected one at a time. Check for
proper system operation after each connection.
4.Current Sensitivity: At the top center of the board is the “Current Sensitivity” adjustment. It adjusts the amount of force the operator will exert before it senses an obstruction. As the wheel is turned counter clockwise, the op erator will reverse more
easily. As the wheel is turned clockwise, the operator will push harder. Any time
the system “CURRENT SENSES” it will stop and reverse for two (2) seconds. If
the system “CURRENT SENSES” a second time before fully opening or closing –
it will again reverse for two (2)_seconds and then go into a HARD SHUTDOWN
(see below). Sensitivity should be set to a level that is sufficiently strong to open
and close the gate in all conditions – yet still sensitive enough to be safe. A good
starting point is the one o’clock position.
21
TROUBLESHOOTING
5.
Activating the system: A momentary connection between activation inputs and ground
(GND) is how the system is activated. At the upper left and bottom right of the board
are terminals marked INP or INPUT. These terminals - when momentarily shorted to
ground (GND) - will open, stop and close the gate with each activation. The button on
the side of the box (swing gates ONLY) is connected to these terminals and may be
used to activate the gate when the key is in the horizontal position. On our newest
boards there is an “OPERATE” button at the upper left area of the board that may be
used in the same manner.
6.HARD SHUTDOWN: If the system has encountered an obstruction two times before
fully opening or closing – the HARD SHUTDOW N LED (upper right of board) will begin flashing – indicating a Hard Shutdown situation. Check to see that any obstructions are removed from the gates path and then press the “HARD SHUTDOWN RESET” button to restart the system.
7.Left Hand / Right Hand Operation: All APOLLO Slide Gates are shipped from the factory wired to close to the left (when looking out of the property). It is suggested to install and adjust the operator as it comes from the factory – then re-wire the system if
necessary. The easiest way to determine if your system requires re-wiring is to use
the LED Enable button. Once the LEDs are enabled, the OPEN LIMIT light should
come on in the open position and the CLOSED LIMIT light should come on when the
gate is closed. Should these be backwards – make the following changes: If the operator has a left/right input A/input B, move plug to other input. From the MASTER
plug – there are five wires going to a terminal strip… If operator does not have input
A/input B board, reverse the RED with the BLACK - and – reverse the ORANGE with
the WHITE. To verify that the wiring has been changed correctly: Manually move the
gate to the mid-way position and plug the main harness into the EMERGENCY BYPASS receptacle – the gate should OPEN. If it closes – the RED and BLACK motor
wires must be reversed. Once it is verified that the EMERGENCY BYPASS does open
the gate – then check the limit switch wiring. Dis-engage the mechanical release and
open the gate fully – verify the OPEN LIMIT led is on. Close the gate fully – verify the
CLOSED LIMIT led. If the limits are backwards – reverse the ORANGE and WHITE
limit wires.
8.Dual Gate Systems: Test dual gate systems individually. Turn program switch #3 ON
(disables SLAVE side of board) and test actuators one at a time using MASTER side
of board only. Confirm proper operation of each actuator. If both test 100% - then test
together by connecting both actuators and turning program switch #3 to the OFF position.
9.EMERGENCY BYPASS: At the bottom left of the board is the EMERGENCY BYPASS
receptacle. Plugging the operator harness into this receptacle will OPEN the gate
ONLY! It is intended to open the gate(s) should other methods fail. Note that if the motor draws more than 15 amps of current the fuse above the receptacle will blow. Also,
the gate operator will not stop by its self at the open position. The plug must be removed to stop the gate. (This is also a handy way to test that the current consumption
of the motor is within the normal limits)
10.FIRMWARE: In the upper right area of the board there is a micro-processor that has a
white label on it. This is the “FIRMWARE” of the system. Currently we are using firmware version V31.00.06. For troubleshooting versions of the firmware earlier than
V31.00.00 consult your original instructions that were included with your system. Systems that are out of warranty may be upgraded to newer version firmware for a nominal fee.
22
APOLLO Gate Ope ra t ors, Inc .
LIMITED TWO-YEAR WARRANTY
Apollo Gate Operators are warranted against defects for a period of
24 months from the date of purchase, providing recommended installation
procedures are followed. This warranty is in lieu of all other warranties
expressed or implied (some states do not allow limitations on how long an
implied warranty lasts, so this limitation may not apply to you) and shall be
considered void if damage was due to improper installation or use,
connection to improper power source, or if damage was caused by fire,
flood, or lightning. The manufacturer will not be responsible for any labor
charges incurred in the removal or replacement of defective parts.
In case of failure due to defective material or workmanship during the
warranty period, the defective part will be repaired or replaced at the
manufactu re r’s op t ion at no cha r ge if returned freigh t pr epa i d . Ne w or f a cto ry
rebuilt replacements may be used. Replacement parts are warranted for the
remaining portion of the original warranty period. The manufacturer will pay
standard ground freight on the return of repaired or replaced items in
warranty.