Enermax EPG500AWT, EPG600AWT, EPG700AWT User Manual

INDEX
Precaution Notice............................................................................................ 1
ENERMAX PRO87+ series Power Supply Specification..............................2
ENGLISH........................................................................................................ 3
DEUTSCH ...................................................................................................... 7
ESPAÑOL ..................................................................................................... 11
ITALIANO .................................................................................................... 19
РУССКИЙ.................................................................................................... 23
POLSKI......................................................................................................... 27
Precaution Notice
Only a technician, authorized by ENERMAX, is allowed to perform maintenance service! Warranty is subject to void under unauthorized attempt to open the power case or modification of any kinds, even attempted only, of the power supply or its components!
ENERMAX will not be responsible for damages caused by following situations:
Opening of the PSU case and/or modification of any component or cable without ENERMAX’
written authorization.
Ignoring connector’s wrong insertion prevention design by attaching a connector to a device in
wrong orientation.
Connecting too many devices to one cable unit by using additional adaptor (Y cables). Damage caused by natural phenomena or uncontrollable forces, such as lightning, flooding, fire,
earthquake, etc.
This ENERMAX Technology Corporation product is warranted to be free from defects in material and workmanship for a period of five (5) years from the date of purchase. ENERMAX Technology Corporation agrees to repair or replace the product, at its own option and at no charge, if, during the warranty period, it is returned to nearest ENERMAX Technology Corporation subsidiary/agent with all shipping charges prepaid and bearing a return merchandize authorization (RMA) number, and if inspection reveals that the product is defective. Charges for removing or installing the product are excluded under the terms of this warranty agreement. This warranty shall not apply to any product, which has been subject to connection to a faulty power source, alteration, negligence, or accident, or to any product, which has been installed other than in accordance with these instructions. In no event shall ENERMAX Technology Corporation, or its subsidiaries, or agents be liable for damages for a breach of warranty in an amount exceeding the purchase price of this product!
If you are uncertain whether or not your ENERMAX PSU is defective, please contact your dealer/reseller for support!
Web Site: www.enermax.com Forum: forum.enermax.com E-mail: enermax@enermax.com.tw
ENERMAX Technology Corporation, 15F-2, No. 888, Jing-Guo Road, Taoyuan City (330), Taiwan (R.O.C.)
Tel. +886-3-316-1675 Fax. +886-3-346-6640
©2009 ENERMAX Technology Corporation. All rights reserved. Specifications are subject to change without prior notice. Actual product and accessories may differ from illustrations. Omissions and printing errors excepted. Content of delivery might differ in different countries or areas. Some trademarks may be claimed as the property of others. Reproduction in any manner without the written permission of ENERMAX is strictly forbidden.
1
ENERMAX PRO87+ Series Power Supply Specification
AC Input Voltage
AC Input Current
3.3V 0-20A 0-24A 0-24A 5V 0-20A
12V1 0-25A 0-25A 0-25A 12V2 0-25A 0-25A 0-25A 12V3 0-25A
-12V 0-0.5A 6W 0-0.5A 6W 0-0.5A 6W
5Vsb 0-3A 15W 0-3A 15W 0-3A 15W
Total Power
Peak Power 550W 660W 770W
Over Current Protection
Over Voltage Protection
(DC)
Under Voltage Protection
(AC)
Under Voltage Protection
Over Power Protection Activated when output power > 120 ~150% of rated max load.
Over Temperature Protection Activated when PSU heat sink > 90 ~ 120oC.
Short Circuit Protection Activated when any DC rails short-circuited.
Surge & Inrush Protection
EPG500AWT EPG600AWT EPG700AWT
100-240VAC, 50-60Hz
(Maximum range:90-265VAC, 47-63Hz)
6.5 – 3A 8 – 3.5A 9 – 4A DC Output
Rated Combined Rated Combined Rated Combined
100W
492W (41A)
0-24A
0-25A
120W
600W (50A)
0-24A
0-25A
500W 600W 700W
Protection Circuit
DC Rail OCP trigger range
3.3V 30 – 40A 5V 30 – 40A
12V 30 – 40A
DC Rail OVP trigger range
3.3V 3.7-4.1V 5V 5.7-6.5V
12V 13.1-14.5V
DC Rail UVP trigger range
3.3V 2.0 – 2.4V 5V 3.3 – 3.7V
12V 8.5 – 9.5V
Activated when AC input voltage < 70VAC.
Sustain 2KV surge stroke. Sustain up to 48A inrush current @ 240VAC at cold start.
120W
696W (58A)
ENVIRONMENT
o
C (for full rated output)
o
C
o
C
o
C
Temperature
Humidity
Operation ambient: 0~50 Storage ambient: -40~70 Operation: to 85% relative humidity, non-condensing at 25 Storage: to 95% relative humidity, non-condensing at 50
OTHERS
Cooling One 13.9cm twister bearing fan, speed auto controlled.
o
C
MTBF
> 100,000 hours at 70% of full rated load, 230VAC/50Hz, 25
(MIL-HDBK-217F standard)
Dimension 150 (w) x 86 (h) x 160 (d) mm
Weight 2.35kg ±150g
Safety UL/cUL(Level 6), TUV, CCC, GOST, CB, BSMI
EMC CE, FCC, KCC
2
User’s Manual
Dear customer,
Thank you for choosing this ENERMAX PRO87+ power supply unit (PSU)! Please read this manual carefully and follow its instructions before installing the PSU.
We would like to draw your attention that a computer required very specific conditions to work best for you without failing. To avoid failures and to increase lifetime of the system, we suggest that:
Your system is NOT located near a radiator or any other heat producing device. Your system is NOT located near a magnetic device. Your system is NOT located in a moist and/or dusty and/or vibrating environment. Your system is NOT exposed to direct sunshine. Your system is sufficiently cooled by additional fans. If you use AC extension cables, please make sure it can support all connected appliances’
potential peak power draw. Or redistribute other high power consumption equipment, such as laser printers or monitors to other AC wall outlets. Exceeding the extension cable’s loading capacity could trigger its circuit breaker and cut off the power.
If you want to add the UPS (Uninterruptible Power Supply) for your system, please choose
adequate Watts/VA capacity UPS. Ex.
PSU Model
EPG500AWT 600W / 1000VA EPG600AWT 700W / 1100VA EPG700AWT 800W / 1200VA
* If you intend to add other appliance powered by the same UPS, such as monitor or printer,
please use higher capacity UPS according to all connected devices’ rated power draw.
* Please do not mistake VA capacity as Watts, or use insufficient power UPS. This would result
in less UPS battery runtime or the inability to power the system in battery mode.
Suggested minimum UPS output power capacity
(Based on efficiency & PFC at respective load)
COMPATIBILITY
ENERMAX PRO87+ series is compliant with: Intel ATX12V Power Supply Design Guide v2.3 specification and downward compatible with
v2.0, v2.01 and v2.2
ATX System Design Guide v2.2, v2.1 BTX/ EEB/ CEB/EPS12V
This PSU does not support MB with ISA expansion slot, which might require –5V power. –5V has been cancelled from Intel ATX12V v1.3 specification onwards.
ENGLISH
3
NAME OF PARTS
1Output cable: Please check “Cables &
Connectors” section.
# 1
# 2
# 3
# 1
# 2
2 13.9cm fan. 3 Honeycomb air vent. 4 ON/OFF switch: (I=ON, O=OFF). 5 AC Inlet. 6 CordGuard.
#1 To ensure best system cooling, do not block PSU fan’s air in-take and air vent area.
This PSU offers a special HeatGuard function. When the system is turned off, or goes into ACPI S3/S4 sleep mode, the PSU fan will keep dissipating the remaining heat for 30 ~ 60 seconds and prolonging system lifetime.
#2 When assembling or maintaining the system, please remove AC cord from AC inlet, or turn
ON/OFF switch into “OFF” position.
#3 AC cord can get loose in many ways. The ENERMAX CordGuard lock can fix your AC cord tightly to the
PSU, so that it will not be easily detached and avoid shut-downs of your PC. The following is CordGuard installation:
Set your PSU into the chassis, and please
make sure the I/O switch is on “O” position.
Plug the AC cord into your PSU.
1. CordGuard is for AC cords supplied with ENERMAX CordGuard-compatible PSUs. Other AC cords may be incompatible.
2. When assembling or maintaining the system, please remove AC cord from AC inlet, or turn I/O switch into “O” position.
Press two sides of the CordGuard lock
together, and set it into CordGuard holder near the AC inlet.
Lock CordGuard to latch onto AC cord.
4
ENGLISH
CONNECTOR TYPES
24P Mainboard
For new generations of ATX/EEB/CEB server/workstation MB.
8P CPU +12V (700W) Supports multi-CPU server/workstation systems and some single socket systems.
4+4P (8P) CPU +12V, in combined mode
8-pin configuration supports multi-CPU server/workstation systems and some single extreme CPU systems.
4+4P (8P) CPU +12V, in split mode
4-pin configuration supports certain single CPU systems. Some multi-CPU workstation/server system might also need this extra 4-pin 12V connector.
Please use the connector with “12V” marking.
6+2P (8P) PCI Express, in combined mode
8-pin configuration supports latest extreme graphic cards, which require 8-pin PCI-E connector.
6+2P (8P) PCI Express, in split mode / 6P PCI Express
6-pin configuration supports most performance PCI-E graphic cards, which require 6-pin PCI-E connector.
SATA
# 1
For SATA/SAS drives.
4P Molex
# 2
For IDE/SCSI/SAS drives or some AGP graphic card with traditional 4P power in socket.
FDD
For floppy drive or certain add-on card.
#1 Some SATA drives might accept SATA or 4P Molex power. Normally, use either one of
power connector to power the driver, BUT NOT BOTH! Please check the drive’s manual or details.
#2 Some MB might require this connector to share the +12V current from 24-pin Mainboard
connector to PCI-E slot. If your MB already supports 24-pin Mainboard connector, you may not need to add the 4P Molex connector on it. Please check the MB’s manual for details.
ENGLISH
5
BOOTING YOUR SYSTEM
Before booting your system, please check that:
1. Main power connector (24P) is properly connected.
2. CPU +12V power connector (4 or 8-pin configuration), and/or a 4P Molex connector (if required by MB) is properly connected.
3. All other needed connectors are properly connected.
4. AC cord is properly connected to wall outlet and PSU AC inlet.
5. Close your system chassis.
6. Turn on the PSU by switching the ON/OFF switch to “ON”, and your system is ready.
PROTECTION, SAFETY & SECURITY
This ENERMAX PSU features multiple protections. In case of most abnormal situations, the power supply will automatically turn off to avoid potential danger to itself and other PC components. It is usually a malfunction of components or user’s negligence to trigger off a protection event. In such circumstance, please check your PC devices and working environment for malfunction:
1. Turn I/O switch of power supply into “O” position, or disconnect AC cord from wall plug and
power supply AC inlet.
2. Check PSU for temperature by simply touching it. If it is very hot, this can be caused by
malfunction of case fans or the PSU fan itself and/or wrong positioning of your PC.
3. Wait some minutes until PSU cools off.
4. Reconnect AC cord to wall plug and power supply AC inlet.
5. Turn I/O switch of power supply into “I” position, and reboot your system.
6. Check, if all fans are working.
7. Contact technical support of the respective manufacturer of the component which you think might
be the cause to the problem. (e.g. MB, GPU or PSU)
If you have any question or need support, please contact your reseller or nearest ENERMAX subsidiary/agent or ENERMAX headquarter service center.
Web Site: www.enermax.com Forum: forum.enermax.com
E-mail: enermax@enermax.com.tw
©2009 ENERMAX Technology Corporation. All rights reserved. Specifications are subject to change without prior notice. Actual product and accessories may differ from illustrations. Omissions and printing errors excepted. Content of delivery might differ in different countries or areas. Some trademarks may be claimed as the property of others. Reproduction in any manner without the written permission of ENERMAX is strictly forbidden.
6
ENGLISH
Benutzerhandbuch
Sehr geehrte Kundin, sehr geehrter Kunde,
Vielen Dank, dass Sie sich für dieses ENERMAX PRO87+-Netzteil (PSU) entschieden haben! Bitte lesen Sie sich dieses Handbuch sorgfältig durch und folgen Sie bitte seinen Anweisungen bevor Sie das Netzteil installieren! Wir möchten Sie darauf hinweisen, dass moderne Systeme sehr empfindlich geworden sind und genau definierte Bedingungen benötigen, um optimal ohne Ausfälle arbeiten zu können. Um solche Ausfälle zu vermeiden und die Lebensdauer Ihres Systems zu verlängern, empfehlen wir Ihnen sicherzustellen, dass:
Ihr System nicht neben einer Heizung oder einer anderen Wärmequelle steht. Ihr System nicht neben einer magnetischen Quelle steht. Ihr System nicht in einer feuchten und/oder staubigen und/oder vibrierenden Umgebung steht. Ihr System nicht dem direkten Sonnenlicht ausgesetzt ist. Ihr System ausreichend durch Lüfter gekühlt wird. Falls Sie ein Verlängerungskabel verwenden, stellen Sie bitte sicher, dass dieses dazu geeignet ist, den
maximalen Strombedarf sämtlicher angeschlossener Geräte zu leisten. Andernfalls schließen Sie bitte weitere viel Strom verbrauchende Geräte (wie Laserdrucker oder Monitor) an eine andere Steckdose an. Ein Überschreiten der maximalen Durchleitungsfähigkeit des Verlängerungskabels könnte zu einem Auslösen der Sicherung führen.
Falls Sie eine USV (Unterbrechungsfreie Stromversorgung) verwenden möchten, nutzen Sie bitte eine
mit ausreichender Watt/VA-Kapazität. Z. B.:
PSU Modell
Empfohlene kleinste USV-Kapazität
(gemäß Effizienz & PFC bei entsprechender Last) EPG500AWT 600W / 1000VA EPG600AWT 700W / 1100VA EPG700AWT 800W / 1200VA
* Falls Sie andere Geräte wie Monitor oder Drucker gleichfalls an die USV anschließen möchten,
wählen Sie bitte eine USV mit höherer Kapazität gemäß der Summe der Leistungsaufnahme aller angeschlossenen Geräte.
* Bitte verwechseln Sie nicht VA mit Watt und nutzen Sie bitte eine ausreichende USV. Andernfalls
verkürzt sich die Laufzeit der Batterie und gefährdet die Versorgung des Systems im Batterie-Modus.
KOMPATIBILITÄT
ENERMAX PRO87+ PSU Serie ist kompatibel mit:
Intel ATX12V Power Supply Design Guide v2.3 Spezifikation und abwärtskompatibel mit v2.0, v2.01,
v2.2.
ATX System Design Guide v2.2, v2.1.
BTX / EEB / CEB / EPS12V.
Dieses Netzteil unterstützt keine MB`s mit ISA Erweiterungsslots, welche -5V benötigen könnten.
-5V wurde ab Intel ATX12V v1.3 Spezifikation abgeschafft.
DEUTSCH
7
DETAILBESCHREIBUNG
Ausgangskabel: Bitte lesen Sie den
Abschnitt „Kabel & Anschlüsse“.
13.9cm Lüfter. #1 Honigwabenluftauslass. #1 I/O Schalter: separater Netzteil-
An/Aus-Schalter (I=AN, O=AUS). #2
Stromeingang. #2 CordGuard. #3
#1 Bitte blockieren Sie nicht die Lufteinlässe/Luftauslässe, um eine bestmögliche Systemkühlung zu
gewährleisten. Dieses PSU verfügt über eine besondere HeatGuard-Funktion: Wenn das System abgeschaltet oder in den ACPI-S3/S4-Schlafmodus gebracht wird, wird der PSU-Lüfter die Restwärme für 30-60 Sek. abführen und so die Lebensdauer des Systems verlängern.
#2 Entfernen Sie immer das Stromkabel vom Netzteil und schalten Sie den I/O-Schalter auf
„O“ während Sie am System arbeiten.
#3 Der Netzstecker kann sich auf unterschiedliche Weise lösen. Der ENERMAX-CordGuard fixiert
den Stecker am Netzteil. Er verhindert unfreiwillige Systemabstürze durch einen versehentlich gezogenen Netzstecker:
Setzen Sie das Netzteil in das Gehäuse ein.
Stellen Sie sicher, dass der Netzschalter auf “O“ (Aus) steht.
Drücken Sie die beiden Seiten des CordGuard
zusammen und befestigen Sie ihn an der dafür vorgesehenen Stelle.
Schließen Sie das Netzkabel am Netzteil
an.
1. Der CordGuard ist nur für Netzkabel geeignet, die mit CordGuard-kompatiblen ENERMAX-Netzteilen ausgeliefert wurden. Andere Netzkabel sind mit dem ENERMAX-CordGuard ggf. nicht kompatibel.
2. Beim Zusammenbauen oder bei der Wartung des Systems ziehen Sie bitte immer den Netzstecker oder stellen Sie den Netzschalter auf “O“(Aus).
Klappen Sie den CordGuard herunter und
sichern Sie auf diese Weise den Netzstecker.
8
DEUTSCH
Anschlusstypen
24P Mainboard
Für die neueste Generation von ATX/EEB/CEB Server/Workstation MB’s.
8P CPU +12V (700W) Unterstützt Multi-CPU Server/Workstation-Systeme und einige Ein-Sockel-Systeme.
4+4P (8P) CPU +12V, in “kombiniertem Modus”
Unterstützt Multi-CPU Server/Workstation-Systeme und einige Hochleistungs-Einzel-CPU-Systeme.
4+4P (8P) CPU +12V, in “getrenntem Modus”
4-Pin Konfiguration unterstützt herkömmliche Einzel-CPU-Systeme. Einige Multi-CPU-Systeme benötigen möglicherweise ebenfalls diesen zusätzlichen Stecker.
Bitte verwenden Sie das Modul mit der „+12V” Markierung.
6+2P (8P) PCI Express, in “kombiniertem Modus”
8-Pin Konfiguration unterstützt die neuesten Grafikkarten, welche diesen 8-Pin PCI-E Stecker benötigen.
6+2P (8P) PCI Express, in “getrenntem Modus” / 6P PCI Express
6-Pin Konfiguration unterstützt die meisten Grafikkarten, welche diesen 6-Pin PCI-E Stecker benötigen.
SATA
# 1
Für SATA/SAS-Laufwerke.
4P Molex
# 2
Für IDE/SCSI/SAS-Laufwerke oder einige AGP Grafikkarten mit traditionellem 4-Pin Stecker.
FDD
Für Floppy-Laufwerke oder einige Erweiterungskarten.
#1 Einige SATA-Laufwerke unterstützen SATA- & 4-Pin-Molex-Stecker. Schließen Sie nur einen Stecker an!
Lesen Sie ansonsten im Handbuch des Laufwerks nach!
#2 Einige MB´s unterstützen diesen Stecker zur zusätzlichen Stromversorgung des 20-Pin-MB-Steckers. Falls
Ihr MB einen 24-Pin-MB-Sockel besitzt, sollten Sie den 4-Pin-Molex-Stecker nicht anschließen. Lesen Sie dies bitte im Handbuch des MB´s nach!
DEUTSCH
9
Loading...
+ 21 hidden pages