80 PLUS Verification and Testing Report
TYPICAL EFFICIENCY (50% Load):
6/12 Amps
50/60 Hz
750 Watts
Note: All measurements were taken with input voltage at 115 V nominal at 60 Hz. Input AC Current Waveform (ITHD = 6.68%, 50% Load)
0.81 0.97 16.85% 10% 90.09 11.57/0.03 3.41/1.32 5.05/1.32 5.13/0.21 76.57 85.00%
1.58 0.95 24.14% 20% 173.39 11.58/0.05 3.41/2.64 5.05/2.62 5.13/0.42 153.46 88.50%
3.78 0.99 6.68% 50% 431.40 11.61/0.13 3.4/6.61 5.04/6.54 5.14/1.05 383.02 88.79%
7.97 0.99 3.92% 100% 909.90 11.71/0.25 3.39/13.22 5.03/13.07 5.14/2.11 762.60 83.81%
Enermax Technology Corporation
12V (cumulative of 12V1, 12V2, etc.)
DC Terminal Voltage (V)/ DC Load Current (A)
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
0% 25% 50% 75% 100% 125%
Efficiency (%)
Loading (% of Rated Output Power)
Efficiency of the Power Supply
Efficiency
Input Watts
Output Watts
0
100
200
300
400
500
600
700
800
900
1000
20% 50% 100%
Power (Watts)
Loading (% of Rated Output Power)
Input and Output Power
These tests were conducted by a third party independent testing firm on behalf of the
80 PLUS Program. 80 PLUS is a certification program to promote highly-efficient
power supplies (greater than 80% efficiency in the active mode) in technology
applications. http://www.80plus.org/
-80.0
-60.0
-40.0
-20.0
0.0
20.0
40.0
60.0
80.0
-200
-100
0
100
200
-0.002 0.003 0.008 0.013
Current (A)
Voltage (V)
Time (s)
Input Current and Voltage Waveforms
Voltage Current