Emko ESM-3710-N User manual [ml]

ESM-3710-N 77 x 35 DIN Size
Digital , ON / OFF Temperature
Controller
- 4 Digits Display
- NTC Input or PTC Input or
J Type thermocouple Input or, K Type thermocouple Input or, 2-Wire PT-100 Input or, 2-Wire PT-1000 Input
- Adjustable temperature offset
ON/OFF temperature control
-
- Selectable heating or cooling function
- Selection of operation with hysteresis
- Adjustable temperature offset
- Set value low limit and set value high limit boundaries
- Compressor protection delays
- Adjustable internal buzzer according to sensor defect status.
- Password protection for programming section
- Installing parameters using Prokey
ESM-3710-N 77x35 DIN Size Temperature Controller
- Remote access, data collecting and controlling with Modbus RTU
- Having CE mark according to European Norms
(Must be determined in order.)
Instruction Manual. ENG ESM-3710-N 01 V07 11/18
ENGLISH
1.Preface
ESM-3710N series temperature controllers are designed for measuring and controlling temperature. They can be used in many applications with their On / Off control form, heating and cooling control form and easy-use properties. Some application fields which they are used are below:
Application Fields Applications
Glass Heating Food Baking Ovens Plastic Incubators Petro-Chemistry Storages Textile, Automative Air Conditioning Machine Production Industries Etc... Etc...
1.1 Environmental Ratings
Operating Temperature : -20 to 70 °C
Max. Operating Humidity : 90% Rh (non-condensing)
Altitude : Up to 2000 m. Forbidden Conditions:
Corrosive atmosphere
c
Explosive atmosphere Home applications (The unit is only for industrial applications)
1.2 General Specifications
Standard
230V ( %15) 50/60HzV ±
Optional Supply Voltage
V
115 V (±%15) 50/60Hz,
V
24 V (±%15) 50/60Hz,
W
24 V (±%15) 50/60Hz, 10
- 30 V Z
NTC, PTC, J or K Type TC 2-Wire PT-100 2-Wire PT-1000
ESM-3710-N
Power Supply Input
Temperature Sensor Input
Standard
Output-1 (Relay Output)
Optional
Output-1 (SSR Drive Output)
Control Output
Alarm Output
Control Output
Alarm Output
Heating or Cooling
Function
ON/OFF Operation
2
1.3 Installation
A visual inspection of this product for possible damage occurred during shipment is recommended before installation. It is your responsibility to ensure that qualified mechanical and electrical technicians install this product.
If there is danger of serious accident resulting from a failure or defect in this unit, power off the system and separate the electrical connection of the device from the system.
The unit is normally supplied without a power supply switch or a fuse. Use power switch and fuse as required.
Be sure to use the rated power supply voltage to protect the unit against damage and to prevent failure.
Keep the power off until all of the wiring is completed so that electric shock and trouble with the unit can be prevented.
Never attempt to disassemble, modify or repair this unit. Tampering with the unit may results in malfunction, electric shock or fire.
Do not use the unit in combustible or explosive gaseous atmospheres.
During putting equipment in hole on the metal panel while mechanical installation some metal burrs can cause injury on hands, you must be careful.
Montage of the product on a system must be done with it’s fixing clamps. Do not do the montage of the device with inappropriate fixing clamp. Be sure that device will not fall while doing the montage.
It is your responsibility if this equipment is used in a manner not specified in this instruction manual.
1.4 Warranty
EMKO Elektronik warrants that the equipment delivered is free from defects in material and workmanship. This warranty is provided for a period of two years. The warranty period starts from the delivery date. This warranty is in force if duty and responsibilities which are determined in warranty document and instruction manual performs by the customer completely.
1.5 Maintenance
Repairs should only be performed by trained and specialized personnel. Cut power to the device before accessing internal parts. Do not clean the case with hydrocarbon-based solvents (Petrol, Trichlorethylene etc.). Use of these solvents can reduce the mechanical reliability of the device. Use a cloth dampened in ethyl alcohol or water to clean the external plastic case.
1.6 Manufacturer Company
Manufacturer Information:
Emko Elektronik Sanayi ve Ticaret A.Ş. Demirtaş Organize Sanayi Bölgesi Karanfil Sk. No:6 16369 BURSA/TURKEY Phone : +90 224 261 1900 Fax : +90 224 261 1912
Repair and maintenance service information:
Emko Elektronik Sanayi ve Ticaret A.Ş. Demirtaş Organize Sanayi Bölgesi Karanfil Sk. No:6 16369 BURSA /TURKEY Phone : +90 224 261 1900 Fax : +90 224 261 1912
3
2. General Description
Front Panel IP65 protection NEMA 4X
Panel Surface (maximum thickness 15 mm / 0.59 inch)
Mounting Clamp
2.1 Front View and Dimensions of ESM-3710-N Temperature Controller
Maximum 15 mm / 0.59 inch
O
C
ESM3710-N
O
S
P
F
SET
P
ü
34,5 mm / 1.36 inch
76 mm / 3 inch
2.2 Panel Cut-Out
29 mm / 1.14 inch
6 mm / 0.24 inch
110 mm / 4.33 inch (min)
71 mm / 2.79 inch
65 mm / 2.56 inch
50 mm / 1.97 inch (min)
4
2.3 Panel Mounting
1
3
2
1-Before mounting the device in your panel, make sure that the cut-out is of the right size.
2-Insert the device through the cut-out. If the mounting clamps are on the unit, put out them before inserting the unit to the panel.
3- Insert the mounting clamps to the fixing sockets that located left and right sides of device and make the unit completely immobile within the panel
3
2.4 Removing from the Panel
1-Pull mounting clamps from left and right fixing sockets.
2-Pull the unit through the front side of the panel
1
2
Before starting to remove the unit from panel, power off the unit and the related system.
c
3. Using Prokey
TO USE PROKEY, VALUE OF THE PrC PARAMETER MUST BE ‘0’. IF PrC=1 AND BUTTON IS PRESSED MESSAGE WILL BE SHOWN. 10s. LATER DEVICE TURNS BACK TO THE MAIN OPERATION SCREEN OR YOU CAN PRESS SET BUTTON TO TURN BACK TO MAIN OPERATION SCREEN.
DOWNLOADING FROM DEVICE TO PROKEY
1.The device is programmed by using the parameters.
2.Energize the device then put in PROKEY and press button. Message is shown on the display. When the loading has finished, message is shown.
3.Press any button to turn back to main operation screen.
4.Remove the PROKEY.
NOTE: message is shown when an error occurs while programming. If you want to reload, put
in PROKEY and press button. If you want to quit, remove PROKEY and press button. The
device will turn back to main operation screen.
DOWNLOADING FROM PROKEY TO DEVICE
1.Switch off the device.
2.Put in PROKEY then energize the device.
3.When the device is energized, the parameter values in PROKEY, start downloading to the device automatically. At first, message is shown on the display, when loading has finished, message is shown.
4.After 10 seconds device starts to operate with new parameter values.
5.Remove the PROKEY.
NOTE: message is shown when an error occurs while programming. If you want to reload, switch off the device and put in PROKEY then energize the device. If you want to quit remove PROKEY and press button. The device will turn back to main operation screen.
5
4. Electrical Wiring Diagram
N
a
L
3
21 4 5 6 7
(-)
P/N : ESM-3710-N
Electrical Wiring Diagram for 30(15)A @ 240 V V Relay Output Devices:
P/N : ESM-3710-N
(+)
For SSR Output
N
a
L
3 4 21 5 6 7 8
4.1 Supply Voltage Input Connection of the Device
Power Supply Connection
L
N
a
(+)(-)
4
5
EXTERNAL
FUSE (1A T)
Note-1
Supply
Switch
c
Supply Voltage
V ±
230V ( %15) 50/60Hz ,
V ±
115V ( %15) 50/60Hz,
V ±
24V ( %15) 50/60Hz ,
W ±
24V ( %15) 50/60Hz ,
10..30 V - 1.5 W
Z
Must be determined in order.
Note-1 : External fuse is recommended.
Make sure that the power supply voltage is the same indicated on the instrument.
c
Switch on the power supply only after that all the electrical connections have been completed. Supply voltage range must be determined in order. While installing the unit, supply voltage range must be controlled and appropriate supply voltage must be applied to the unit.
There is no power supply switch on the device. So a power supply switch must be added to the supply voltage input.
c
Power switch must be two poled for seperating phase and neutral, On/Off condition of power supply switch is very important in electrical connection.
External fuse that on Vpower supply inputs must be on phase connection. External fuse that on Zpower supply inputs must be on (+) connection.
Temperature Sensor
TC,NTC,PTC,PT-100 or PT-1000
Supply Voltage Input
V ±
230V ( %15) 50/60Hz
V ±
115V ( %15) 50/60Hz
V ±
24V ( %15) 50/60Hz
10...30 V
Z
Must be determined in order.
Relay or SSR Output
Temperature Sensor
NTC
Supply Voltage Input
V ±
230V ( %15) 50/60Hz
V ±
115V ( %15) 50/60Hz
V ±
24V ( %15) 50/60Hz
10...30 V
Z
Must be determined in order.
Relay Output
30(15)A@240 V V
Input
Input
6
Supply Voltage InputConnection for 30(15)A @ 240 V V Relay Output Devices:
L
N
EXTERNAL
FUSE (1A T)
a
(+)(-)
5
6
Note-1
Supply Switch
V ±
230V ( %15) 50/60Hz ,
V ±
115V ( %15) 50/60Hz,
V ±
24V ( %15) 50/60Hz ,
W ±
24V ( %15) 50/60Hz ,
10..30 V - 1.5 W
Z
Must be determined in order.
c
Supply Voltage
4.2 Device Label and Connection Diagram
230VV CONNECTION DIAGRAM
P/N : ESM-3710-N - 5.18.0.1/00.00/2.3.0.0
16(8)A @
230 VV ± 15%
250VV1HP
50/60Hz - 1.5VA
OUTPUT
NO NCC
LINE
LOAD
7
NTC
INPUT SCALE
(-50 ,100 ; -58 ,212 ) °C °C °F °F
RS-485
PROKEY
or
L
N
30(15)A @ 240 V V Connection Diagram for Relay Output Devices:
P/N:ESM-3710-N-5.18.0.3/00.00/2.3.0.0
30(15)A @ 240VV
230 VV ± 15%
OUTPUT
50/60Hz - 1.5VA
7 8
NTC
INPUT SCALE
(-50 ,100 ; -58 ,212 ) °C °C °F °F
RS-485
PROKEY
or
L
N
5.Front Panel Definition and Accessing to the Menus
5 6 7 7
1
2
BUTTON DEFINITIONS
1. Increment Button :
** It is used to increase the value in the Set screen and Programming mode.
2. Decrement, Silencing Buzzer and Downloading to Prokey Button :
** It is used to decrease the value in the Set screen and Programming mode. ** It is used to silence the buzzer. ** If Prc =0, it is used to download from device to prokey.
6
16A Fuse
30A Fuse
@250VV1HP
1
1
8
O
O
C
16(8)A
OUTPUT
C
2
30(15)A@240VV
OUTPUT
2
F
LOAD
9
S
3
3
LOAD
10
NCNO
P
ESM3710-N
SET
P
ü
a
4
5
L
N
a
54
6
L
N
3
3
4
RS-485
or
PROKEY
6
7
NTC
RS-485
or
PROKEY
7
8
NTC
7
3. Set Button :
** In the main operation screen; if this button pressed, set value will be displayed. Value can be changed using increment and decrement buttons. When Enter button pressed, value is saved and returns back to main operating screen. ** To access the programming screen; in the main operation screen, press this button for 5 seconds.
4. Enter Button :
** It is used to saving value in the Set screen and programming screen.
LED DEFINITIONS
5. Cooling led :
** This led indicates that cooling control is selected and process output relay is active. If any of compressor protection time active, this led blinks.
6.Heating led :
** This led indicates that heating control is selected and process output relay is active.
7.Celcius led :
** Indicates that device is in C mode.
8.Fahrenheit led :
** Indicates that device is in F mode.
9.Set led :
** Indicates that device is in Set value changing mode.
10.Program led :
**Blinks in programming mode .
6. Changing and Saving Temperature Set Value
Main Operation Screen
When SET button pressed ‘’S’’ led will
be active and temperature set value will
Temperature set value parameter (Default=50) MODBUS ADDRESS:40001
Temperature set value, can be programmed between minimum temperature set value and
maximum temperature set value .
be displayed.
When ENTER button pressed
temperature set value can be saved.
6.1 Programming Mode Parameter List
o
o
O
ESM3710-N
O
S
P
C
F
SET
P
ü
O
ESM3710-N
O
S
P
C
F
SET
P
ü
ü
SET Value Screen
O
ESM3710-N
O
S
P
C
F
SET
P
ü
Temperature set value can
be changed with increment
and decrement buttons.
Main Operation Screen
O
‘’S’’ will be inactive and goes back to
main operation screen.
ESM3710-N
O
S
P
C
F
SET
P
ü
ü
Temperature Unit Selection Parameter ( Default = 0 ) MODBUS ADDRESS:40002
°C selected. °F selected.
Decimal Seperator Enabling Parameter ( Default = 0 ) MODBUS ADDRESS:40003
Disable. Enable.
8
Note: If sensor input type is selected J, K, PT-100 or PT-1000 (BC =05,10,11 or 14) parameter is
skipped.
Hysteresis Parameter for Compressor Output ( Default = 1 ) MODBUS ADDRESS:40004
from -20 to 20 °C for NTC(-50°C, 100°C) or PTC(-50°C, 150°C) or J Type TC (0°C,800°C)
or J Type TC (0°C,1000°C) or PT-100(-50°C, 400°C)or PT-1000 (-50°C, 150°C) or PT-100 (-20°C, 100°C), from -36 to 36 °F for NTC(-58°F, 212°F) or PTC (-58°F, 302°F) or J Type TC (32°F,1472°F) or or K Type TC (32°F,1830°F) or PT-100(-58°F, 752°F) or PT-1000(-58°F, 752°F) or PT-100(-4°F, 212°F), from -10.0 to 10.0°C for NTC (-50.0°C,100.0°C) or PTC(-50.0°C,150.0°C) or PT-100 (-19.9°C,99.9°C), from -18.0 to
18.0°F for NTC (-58.0°F,212.0°F) or PTC (-58.0°F,302.0°F) or PT-100 (-4.0°F,212.0°F),
In ON/OFF control algorithm, temperature value is tried to keep equal to set value by opening or closing the last control element. ON/OFF controlled system, temperature value oscillates continuously. Temperature value’s oscillation period or amplitude around set value changes according to controlled system. For reducing oscillation period of temperature value, a threshold zone is formed below or around set value and this zone is named hysteresis.
Minimum Temperature Set Value Parameter (Default = Minimum Value of Device Scale ) MODBUS ADDRESS:40005
Temperature set value can not be lower than this value. This parameter value can be adjusted from minimum value of device scale to maximum temperature set value parameter
Maximum Temperature Set Value Parameter (Default = Maximum Value of Device Scale ) MODBUS ADDRESS:40006
Temperature set value can not be bigger than this value. This parameter value can be adjusted from minimum temperature set value parameter to maximum value of the device scale
Sensor Offset Parameter ( Default = 0 ) MODBUS ADDRESS:40007
from -20 to 20 °C for NTC(-50°C, 100°C) or PTC(-50°C, 150°C) or J Type TC (0°C,800°C) or
J Type TC (0°C,1000°C) or PT-100(-50°C, 400°C)or PT-1000 (-50°C, 150°C) or PT-100 (-20°C, 100°C), from -36 to 36 °F for NTC(-58°F, 212°F) or PTC (-58°F, 302°F) or J Type TC (32°F,1472°F) or or K Type TC (32°F,1830°F) or PT-100(-58°F, 752°F) or PT-1000(-58°F, 752°F) or PT-100(-4°F, 212°F), from -10.0 to 10.0°C for NTC (-50.0°C,100.0°C) or PTC(-50.0°C,150.0°C) or PT-100 (-19.9°C,99.9°C), from -18.0 to
18.0°F for NTC (-58.0°F,212.0°F) or PTC (-58.0°F,302.0°F) or PT-100 (-4.0°F,212.0°F),
Operating Type Parameter ( Default = 0) MODBUS ADDRESS:40008
If parameter value is ‘0’ device skips to parameter
Temperature
Set
Control Output
ON
OFF
HSt
HSt
Time
Time
Heating
Cooling
Compressor Start Delay at Power On Parameter ( Default = 0) MODBUS ADDRESS:40009
When power is first applied to the device, compressor is on when this time delay is expired. It can be adjusted from 0 to 20 minutes.
9
Compressor Stop-Start Delay Parameter ( Default = 0) MODBUS ADRES:40010
When compressor is inactive, this time delay must be expired for activation of the compressor. It can be adjusted from 0 to 20 minutes
Compressor Start-Start Delay Parameter ( Default = 0) MODBUS ADRES:40011
This time delay must be expired between two activation of the compressor. It can be adjusted from 0 to 20 minutes.
Sensor Defect Parameter ( Default = 0 ) MODBUS ADRES:40012
Compressor is OFF in case of sensor defect. Compressor is ON in case of sensor defect. Compressor operates periodically according to and Time periods in
case of sensor defect.
Compressor is active during this time period in case of probe defect (Default = 0) MODBUS ADRES:40013
If probe defect parameter is 2, then this parameter is observed. It can be adjusted from 0 to 99 minutes.
Compressor is inactive during this time period in case of probe defect ( Default = 0 )MODBUS ADRES:40014
If probe defect parameter is 2, then this parameter is observed. It can be adjusted from 0 to 99 minutes.
Buzzer Function Selection Parameter ( Default = 0 ) MODBUS ADDRESS:40015
Buzzer is inactive. Buzzer is active during sensor failures.
Buzzer is active during this time
If buzzer function selection parameter value =0, this parameter can not be observed. Buzzer stays active during this time. It can be adjusted from 1 to 99 minutes
When this parameter is 1, if decrement button is pressed, is observed. In this condition buzzer is active till buzzer silence button is pressed.
Communication Mode Selection Parameter ( Default = 0 ) MODBUS ADDRESS:40017
PROKEY communication selected. Rs485 communication selected.
Slave ID Parameter ( Default = 1 ) MODBUS ADDRESS=40018
Device communication address parameter (1 to 247).
Programming Section Accessing Password . ( Default = 0 ) MODBUS ADDRESS:40019
It is used for accessing to the programming section. It can be adjusted from 0 to 9999. If it is selected 0, password will not be asked
, , , , and Parameters are observed if Operation type
i
is selected “Cooling”. If operation type is selected “Heating ” ,skip to the parameter
( Default = ) MODBUS ADDRESS:40016
6.2 Modbus Adresses of Device Status Parameters (Read Input Register)
MODBUS ADDRESS:30001 Temperature Value MODBUS ADDRESS:30002 Reserved MODBUS ADDRESS:30003 Led Status : 0.bit C Led,
A
6.bit Compressor Led,
A
13.bit Program Led, 14.bit Set Led MODBUS ADDRESS:30004 Device Status : 1.bit Buzzer Status
A
2.bit Sensor Lost Status MODBUS ADDRESS:30005 Output Status MODBUS ADDRESS:30006 Device Type and Device Version
o
10
6.3 Operation Graphics of ESM-3710-N ControllerTemperature
1-If Operating Type Parameter Value = 1 (Cooling), Switch On Delay After Power On Parameter Value ³ 1 , Compressor Stop/Start Time Delay Parameter Value ³ 1 and Compressor Start/Start Time Delay Parameter Value ³ 1;
Power
°C
SET
Output
Led
Output
2-If Operating Type Parameter Value = 0 (Heating),
i
Hst
Temperature
Value
SET
ON
OFF
to set value by opening or closing the last control element. ON/OFF controlled system, temperature value oscillates continuously. Temperature value’s oscillation period or amplitude around set value changes according to controlled system. For reducing oscillation period of temperature value, a threshold zone is formed below or around set value and this zone is named hysteresis. Action of control output is described with figures above.
HSt
Temperature Control Output
HSt HSt
In ON/OFF control algorithm, temperature value is tried to keep equal
Time
Time
Time
Time
Time
Time
6.4 Failure Messages in ESM-3710-N Temperature Controller
Screen Blinking Sensor failure . Sensor connection is wrong or there is no sensor connection. If buzzer function selection parameter is 1, internal buzzer starts to operate.
11
6.5 Entering To The Programming Mode, Changing and Saving Parameter
Main Operation Screen
ESM3710-N
O
O
S
P
C
F
SET
P
O
O
S
C
F
ü
P
ESM3710-N
SET
P
ü
When SET button is pressed for 5
seconds, “P” led starts to blink. If
programming mode entering password is different from 0,
programming mode entering screen
will be observed.
O
O
S
P
C
F
Note1: If programming
mode accessing password is 0, Temperature Unit screen is observed instead of programming screen
ESM3710-N
SET
P
Programming Mode
Entering Screen
Press OK button for
accessing to the
password entering
screen.
O
O
C
ü
Password Entering Screen
Enter programming mode accessing password
with increment and decrement buttons.
Note2: If programming mode accessing password is 0, only three parameters are accessible, and the parameter values can be changed.
Programming Screen
ESM3710-N
O
O
S
P
C
F
SET
P
Password Entering Screen
Press OK button for entering
the password.
O
O
C
ü
Press SET button for accessing to the parameter value. Press increment button for accessing to the next parameter, press decrement button for accessing to the previous parameter.
ESM3710-N
O
O
S
P
C
F
SET
P
Hysteresis Value for Compressor Output
Change the value with increment
and decrement buttons.
O
O
C
ü
Hysteresis Value for
Compressor Output
Press OK button for saving the
parameter.
If no operation is performed in programming mode for 20 seconds, device turns to main
i
operation screen automatically..
Press increment button for accessing to the next parameter, press decrement button for accessing to the previous parameter
Hysteresis Parameter for
Compressor Output
ESM3710-N
S
P
F
SET
P
ü
ESM3710-N
S
P
F
SET
P
ü
ESM3710-N
S
P
F
SET
P
ü
12
7. Specifications
Device Type : Temperature Controller Housing & Mounting : 76mm x 34.5mm x 71mm plastic housing for panel
Protection Class : NEMA 4X (Ip65 at front, Ip20 at rear). Weight : Approximately 0.20 Kg. Environmental Ratings : Standard, indoor at an altitude of less than 2000 meters
Storage / Operating Temperature : -30 C to +80 C / -20 C to +70 C Storage / Operating Humidity : 90 % max. (None condensing) Installation : Fixed installation Overvoltage Category : II. Pollution Degree : II, office or workplace, none conductive pollution Operating Conditions : Continuous Supply Voltage and Power :
:10 - 30
Temperature Sensor Input : NTC, PTC, TC, RTD NTC input type : NTC (10 kW @25 °C ) PTC input type : PTC (1000 W @25 °C ) Thermocouple input type : J, K (IEC584.1) (ITS 90) Thermoresistance input type : PT-100, PT-1000 (IEC751) (ITS 90) Accuracy : ± 1 % of full scale for thermoresistance Cold Junction Compensation : Automatically ± 0.1°C / ± 1°C Sensor Break Protection : Upscale Sampling Cycle : 3 samples per second Control Form : ON / OFF Relay Output : 16(8) A@250 V V for Resistive load ( Output)
(Electrical life : 100.000 switching at full load)
Optional SSR Drive Output : Maximum 20mA, Maximum 17V Display : 14 mm Red 4 digits LED Display LED : S (Green), P (Green), C (Yellow), F(Yellow),
Compressor Output (Red), Heating Output (Red) Internal Buzzer : ³83dB
Approvals :
: 115 : 24 : 24
Mounting. Panel cut-out is 71x29mm.
with none condensing humidity.
o o o o
V ±
230V ( %15) 50/60Hz - 1.5VA
V ±
V ( %15) 50/60Hz - 1.5VA
V ±
V ( %15) 50/60Hz - 1.5VA
W ±
V ( %15) 50/60Hz - 1.5VA
VZ 1.5W
Z
o o
,
Compressor
13
8.Ordering Information
00 00
U
V W Z/
/
800°C/1472°F 999°C/1830°F
400°C/752°F
99.9°C/212°F 400°C/752°F
99.9°C/212°F 150°C/302°F 100°C/212°F
ESM-3710-N
(77x35 DIN Sizes)
Supply VoltageA
24VW ( %15) 50/60Hz - 1.5VA ±
2
24V ( %15) 50/60Hz - 1.5VAV ±
3
115V ( %15) 50/60Hz - 1.5VAV ±
4
230V ( %15) 50/60Hz - 1.5VAV ±
5
10 - 30 V Z
8
Input Type
BC
J ,Fe CuNi IEC584.1(ITS90)
05
K ,NiCr Ni IEC584.1(ITS90)
10
PT 100, IEC751(ITS90)
11
PT 100, IEC751(ITS90
09
PT 1000, IEC751(ITS90)
14
PT 1000, IEC751(ITS90
13
PTC (Not-1)
12
NTC (Not-1)
18
Compressor Output
E
Relay Output (16(8) A@250 V V,at resistive Load, 1 NO,1NC )
1
SSR Driver Output (Maximum 20m, Maximum 17VZ )
2
Relay Output (30(15)A@240 V V,at resistive Load, 1 NO)
3
(Only valid for NTC Input Type devices)
Temp. Sensor which is given with ESM-3710-N
V
0
None
PTC-M6L40.K1.5 (PTC Air Probe 1.5 mt Silicon Cable)
1
PTCS-M6L30.K1.5.1/8” (PTC Liquid Probe 1.5 mt Silicon Cable)
2
NTC-M5L20.K1.5 (NTC Sensor, thermoplastic moulded with 1.5 m cable for cooling application)
3
NTC-M6L50.K1.5 ( NTC Sensor, stainless steel housing with 1.5 m cable for cooling application)
4
Customer
All order information of ESM-3710-N Temperature Controller are given on the table at above. User may form appropriate device configuration from information and codes that at the table and convert it to the ordering codes.Firstly, supply voltage then other specifications must be determined. Please fill the order code blanks according to your needs. Please contact us, if your needs are out of the standards.
Note-1:If input type is selected PTC or NTC (BC= 12, 18), Temperature sensor is given with the device.For this reason, if input type is selected as PTC,sensor type (V = 0,1 or 2) or if input type is selected as NTC, sensor type (V = 0,3 or 4) must be declared in ordering information.
c c
9
Because of limited mechanical life of relay output contact, SSRoutput is recommended which the device use PID control algoritm. The device with ON/OFF control algoritm, hysteresis parameter must be set a suitable value for your system, to avoid too much relay switching.
Before commissioning the device, parameters must be set in accordance with desired use. Incomplete or incorrect configuration can cause dangerous stiuations.
A BC D E FG HI /
0 1 0 0
/
Scale(°C)
0°C/32°F ; 0°C/32°F ;
-50°C/-58°F ;
-19.9°C/-4°F ;
-50°C/-58°F ;
-19.9°C/-4°F ;
-50°C/-58°F ;
-50°C/-58°F ;
14
9.Optional Accessories
Because of limited mechanical life of relay output contact, SSRoutput is recommended which the device use PID control algoritm. The device with ON/OFF control algoritm, hysteresis parameter must be set a suitable value
c
for your system, to avoid too much relay switching. Before commissioning the device, parameters must be set in accordance with desired use.
Incomplete or incorrect configuration can cause dangerous stiuations.
c
1.RS-485 Module 2.PROKEY Programming Module
c
V Ş Vac,
RS-485 Communication Interface
Z Ş Vdc
Ş Vdc or Vac
W
can be applied
The device is programmed(Upload or Download) by using the parameters.
Your Technology Partner
Thank you very much for your preference to use Emko Elektronik products, please visit our web page to download detailed user manual.
www.emkoelektronik.com.tr
15
16
ESM-3710-N Digitaler
EIN/AUS-Temperaturregler
DIN-Größe 77 x 35
– 4-stelliges Display – NTC-Eingang oder
PTC-Eingang oder Thermoelement-Eingang Typ J oder Thermoelement-Eingang Typ K oder 2-adriger PT-100-Eingang oder 2-adriger PT-1000-Eingang (Muss in der Bestellung angegeben werden.)
– Einstellbarer Temperatur-Offset EIN/AUS-Temperaturregelung Auswählbare Heiz- oder Kühlfunktion – Auswahl des Betriebs mit Hysterese – Einstellbarer Temperatur-Offset – Sollwertunter- und -obergrenzen – Auswahl des Kompressorbetriebs: durchgängiger Betrieb, Stop
ESM-3710-N Temperaturregler DIN Größe 77x35
oder intermittierender Betrieb bei einem Sensordefekt – Kompressorschutzverzögerungen – Einstellbarer interner Summer abhängig vom Sensordefekt-Status. – Passwortschutz für den Programmierabschnitt – Installationsparameter unter Verwendung von Prokey – Fernzugriff, Datenerfassung und Regelung mit Modbus RTU – Mit CE-Zeichen gemäß europäischen Normen
Bedienungshandbuch. GER ESM-3710-N 01 V07 11/18
DEUTSCH
1. Vorwort
Temperaturregler der Baureihe ESM-3710-N sind auf die Temperaturmessung und -regelung ausgelegt. Mit ihrer Ein/Aus-Regelungsfunktion, Heiz- und Kühlfunktionen und benutzerfreundlichen Eigenschaften können sie in zahlreichen Anwendungen eingesetzt werden. Nachfolgend sind einige Anwendungsbereiche aufgelistet, für die sie geeignet sind:
Anwendungsbereiche Anwendungen
Glas Heizung Lebensmittel Backöfen Kunststoff Brutschränke Petrochemie Lager Textil, Automation Klimaanlagen Maschinenproduktion Industrie Usw.
1.1 Umgebungssollwerte
Betriebstemperatur : -20 bis 70 °C
Max. Betriebsfeuchte : 90 % RF (nicht kondensierend)
Höhe : Bis zu 2000 m.
Unzulässige Bedingungen: Korrosive Atmosphäre
c
Explosive Atmosphäre Anwendungen im Wohnbereich (Das Gerät ist nur für industrielle Anwendungen vorgesehen)
1.2 Allgemeine Spezifikationen
Standard
230V ( %15) 50/60HzV ±
Optionale Versorgungsspannung
V
115 V (±%15) 50/60Hz,
V
24 V (±%15) 50/60Hz,
W
24 V (±%15) 50/60Hz,
- 30 V Z
10
NTC, PTC, J order K Typ TC 2-adriges PT-100 2-adriges PT-1000
ESM-3710-N
Stromversorgung Eingang
Temperatursensor Eingang
Standard
Ausgang-1 (Relaisausgang)
Optional
Ausgang-1
(SSR-Antriebsausgang)
Steuerausgang Alarmausgang
Steuerausgang Alarmausgang
Hei- oder Kühlfunktion EIN/AUS-Betrieb
2
1.3 Installation
Vor der Installation dieses Produkts wird eine Sichtprüfung auf etwaige beim Transport verursachte Schäden empfohlen. Sie müssen sicherstellen, dass dieses Produkt von qualifizierten Elektrikern und Mechanikern installiert wird. Falls bei einem Ausfall oder Defekt dieser Einheit die Gefahr eines ernsthaften Unfalls besteht, schalten Sie das System aus und trennen den Stromanschluss des Geräts vom System. Die Einheit wird normalerweise ohne Netzschalter und Sicherung ausgeliefert. Verwenden Sie bei Bedarf einen Netzschalter und eine Sicherung. Achten Sie darauf, die Auslegungsspannung für die Stromversorgung zu verwenden, um das Gerät vor Schäden zu schützen und Ausfälle zu vermeiden. Schalten Sie den Strom erst ein, wenn die gesamte Verdrahtung abgeschlossen ist, sodass ein Stromschlag und Probleme mit dem Gerät vermieden werden können. Versuchen Sie auf keinen Fall, dieses Gerät zu zerlegen, zu ändern oder zu reparieren. Eine Manipulation des Geräts führt zu Fehlfunktion, Stromschlag oder Brand. Setzen Sie das Gerät nicht in feuergefährlichen oder explosiven gasförmigen Atmosphären ein. Wenn Sie die Ausrüstung bei der mechanischen Installation in die Öffnung in der Metallplatte einsetzen, können Metallgrate Verletzungen an den Händen verursachen. Sie müssen vorsichtig sein. Die Montage des Produkts an einem System muss unter Verwendung der zugehörigen Befestigungsklammern erfolgen. Führen Sie die Montage des Geräts nicht mit ungeeigneten Befestigungsklammern durch. Achten Sie darauf, dass das Gerät während der Montage nicht zu Boden fällt. Sie sind dafür verantwortlich, dass dieses Gerät nicht auf eine Weise verwendet wird, die nicht in diesem Anweisungshandbuch angegeben ist.
1.4 Garantie
EMKO Elektronik garantiert, dass die Ausrüstung frei von Material- und Herstellungsschäden ist. Diese Garantie gilt für einen Zeitraum von zwei Jahren. Der Garantiezeitraum beginnt mit dem Lieferdatum. Diese Garantie gilt, solange der Kunde alle im Garantiedokument und im Betriebshandbuch angegebenen Verpflichtungen und Verantwortlichkeiten einhält.
1.5 Wartung
Reparaturen dürfen ausschließlich von geschultem und spezialisiertem Personal durchgeführt werden. Trennen Sie die Stromversorgung zu dem Gerät, bevor Sie auf interne Bauteile zugreifen. Reinigen Sie das Gehäuse nicht mit auf Kohlenwasserstoff basierenden Lösungsmitteln (Benzin, Trichloräthylen usw.). Durch den Einsatz dieser Lösungsmittel kann die mechanische Zuverlässigkeit des Geräts beeinträchtigt werden. Verwenden Sie ein mit Ethylalkohol oder Wasser befeuchtetes Tuch, um das äußere Kunststoffgehäuse zu reinigen.
1.6 Herstellerunternehmen
Herstellerinformationen Informationen zum Reparatur- und Wartungsservice:
Emko Elektronik Sanayi ve Ticaret A.Ş. Demirtaş Organize Sanayi Bölgesi Karanfil Sk. No:6 16369 BURSA/TURKEY Telefon: +90 224 261 1900 Fax : +90 224 261 1912 Emko Elektronik Sanayi ve Ticaret A.Ş. Demirtaş Organize Sanayi Bölgesi Karanfil Sk. No:6 16369 BURSA /TURKEY Telefon: +90 224 261 1900 Fax : +90 224 261 1912
3
2. Allgemeine Beschreibung
Frontplatte IP65-Schutz NEMA 4X
Schaltschrankoberfläche (max. Dicke 15 mm / 0,59")
Montageklammer
2.1 Vorderansicht und Abmessungen des Temperaturreglers ESM-3710-N
Maximum 15 mm / 0.59 inch
O
C
ESM3710-N
O
S
P
F
SET
P
ü
34,5 mm / 1.36 inch
76 mm / 3 inch
2.2 Einbauausschnitt
29 mm / 1.14 inch
6 mm / 0.24 inch
110 mm / 4.33 inch (min)
71 mm / 2.79 inch
65 mm / 2.56 inch
50 mm / 1.97 inch (min)
4