EMERSON LPS121, LPS122, LPS123, LPS124, LPS125 Service Manual

...
Page 1
Rev. 03.24.08
LPS120 Series
1 of 3
Embedded Power for Business-Critical Continuity
LPS120 Series
120 Watts
Special Features
• 3" x 5" footprint
• Less than 1U high
• EN61000-3-2 compliant
•Remote sense
• Power fail and remote inhibit
• Single wire current sharing
• Adjustable main output
• Built-in Class B EMI filter
• Overvoltage protection
• Overload protection
• Thermal overload protection
• 5 V Standby output and 12V Fan output
Total Power: 80 - 130 Watts Input Voltage: 85 - 264 VAC # of Outputs: Single
Electrical Specifications
Safety
Input
Input ra nge:
85 - 264 VAC ; 127 - 300VDC
Frequency:
47-440 Hz
Inrush current:
40A max., cold start @ 25°C
Efficiency:
80% typical at full load
EMI/RFI:
FCC Class B conducted; CISPR22 Class B conducted; EN55022 Class B conducted; VDE0878PT3 Class B conducted
Power factor:
0.99 typical Safety ground leakage current:
0.5mA @ 50/60 Hz, 264 VAC input
Output
Maximum power:
80W for convection ; 130W with 30CFM forced air
Adjustment range:
±5% minimum on the main outputs
Fan output:
12V @ 500mA - 5%, +7%
Standby outputs:
5V @ 500mA ±5%
Hold-up time:
20ms @ 125W load, 120VAC input
Overload protection:
Short circuit protection on all outputs. Case overload protect­ed @ 120-135% above rating
Overvoltage protection:
20-35% above nominal output
Remote sense: Compensates for 0.5 V lead drop max. Will operate without
remote sense connected. Reverse connection protected.
Logical Control
Power failure: TTL logic signal goes high 100-500 msec after main output; it
goes low at least 4 msec before loss of regulation
Remote inhibit: Requires a contact closure to disable the outputs, except 5V
standby.
Remote sense: Compensates for 0.5 V lead drop min. Will operate without
remote sense connected. Reverse connection protected.
TUV: 60950 UL: 60950 CSA 60950 NEMKO: 60950 AUSTEL: 60950 CB: Certificate and report CE: Mark (LVD)
RoHS
Page 2
Embedded Power for Business-Critical Continuity
Mechanical Drawing
Rev. 03.24.08
LPS120 Series
2 of 3
Operating temperature:
0° to 50°C ambient derate each output as 2.5% per degree from 50° to 70°C. -20°C start up
Storage temperature: -40°C to +85°C Electromagnetic susceptibility:
designed to meetEN61000-4;
-2, -3, -4, -5, -6, -8, -11 Level 3
Humidity:
Operating; non-condensing 10% to 95% RH
Vibration:
IEC68-2-6 to the levels of IEC721-3-2
MTBF demonstrated
>550,000 hours at full load and 25°C ambient conditions
Environmental Specifications
P1
NEUTRAL
EARTH
4.55
(115.6)
SK1
LIVE
3.00
(76.2)
2.55
(64.8)
0.15" DIA. 4 places
5.00
(127.0)
(4.0)
SK3
V
Adjust
POT
5
1
10
6
SK3
1
2
M3.5 (2 places)
SK2
1.29
(32.8)
0.20" (5)
Page 3
Connector LPS120
SK1 Pin1 Neutral
Pin3 Line
SK2 TB-1 COMMON
TB-2 Main output
SK3 Pin1 +V1 Remote sense
Pin2 -V1 Remote sense Pin3 +Remote inhibit Pin4 -Remote inhibit Pin5 +Power fail Pin6 Common Pin7 SWP Pin8 +12V Pin9 12V common Pin10 +5V standby
Mating Connectors
(SK1)AC Input: Molex 09-50-8031 (connector) 08-52-0113 (pins)
(SK2)DC Output: Molex series 19141-0058/0063 Spade lug
(SK3) Control Signals:
Molex 90142-0010 (USA) PINS: 90119-2110 or Amp: 87977-3 PINS: 87309-8
Astec Connector Kit # 70-841-020, includes all of the above.
Rev. 03.24.08
LPS120 Series
3 of 3
Embedded Power for Business-Critical Continuity
Ordering Information
Model
Number
Output
Voltage
Minimum
Load
Maximum Load
with Convection
Cooling
Maximum Load
with 30CFM
Forced Air
Peak Load Regulation
2
Ripple
P/P
(PARD)
3
LPS121 3.3V 0A 21A 36A 29A ±2% 50mV
LPS122 5V 0A 16A 26A 29A ±2% 50mV
LPS123 12V 0A 6.7A 10.8A 12.8A ±2% 120mV
LPS124 15V 0A 5.3A 8.7A 10.0A ±2% 150mV
LPS125 24V 0A 3.4A 5.4A 6.3A ±2% 240mV
LPS128 48V 0A 1.7A 2.7A 3.2A ±2% 480mV
1. Peak current lasting <30 seconds with a maximum 10% duty cycle.
2 . At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3 . Peak-to-peak with 20 MHz bandwidth and 10 μF (tantalum capacitor) in parallel with a 0.1 μF capacitor at rated
line voltage and load ranges.
4 . When in parallel a 10% load is required for each power supply.
Notes:
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ±.02”.
3. mounting holes MH1, MH2, MH3 should be grounded for EMI purpose
4. Mounting MH1 is safety ground connection
5. Specifications are for convection rating at factory settings at 115 VAC input 25 C deg unless otherwise stated.
6. This power supply requires mounting on metal standoffs
0.20” (5m) in height.
7. Warranty: 2 year
8. Weight: 0.71 lb. / 0.32 kg
Pin Assignments
Americas
5810 Van Allen Way Carlsbad, CA 92008 USA Telephone: +1 (760) 930 4600 Facsimile: +1 (760) 930 0698
Europe (UK)
Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355
Asia (HK)
14/F, Lu Plaza 2 Wing Yip Street Kwun Tong, Kowloon Hong Kong Telephone: +852 2176 3333 Facsimile: +852 2176 3888
For global contact, visit:
www.powerconversion.com
techsupport.embeddedpower @emerson.com
While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions.
Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2008 Emerson Electric Co.
EmersonNetworkPower. com
Embedded Computing
Embedded Power
Monitoring
Outside Plant
Power Switching & Controls Precision Cooling Racks & Integrated Cabinets
Services
Surge Protection
Emerson Network Power.
The global leader in enabling business-critical continuity.
AC Power
Connectivity
DC Power
Loading...