Emerson 92C Installation Guide

Installation Guide English – May 2002
Type 92C
Introduction
This installation guide provides instructions for installation, startup, and adjustment. To receive a copy of the instruction manual, contact your local Fisher Sales Office or Sales Representative or view a copy at www.FISHERregulators.com. For further information refer to:
Type 92C Instruction Manual, form 5135, D100255X012.
P.E.D. Categories
This product may be used as a safety accessory with pres­sure equipment in the following Pressure Equipment Di­rective 97/23/EC categories. It may also be used outside of the Pressure Equipment Directive using sound engi­neering practice (SEP) per table below.
EZISTCUDORPSEIROGETACEPYTDIULF
52dna,02,51ND
TPN)hcni-1dna,4/3,2/1(
PES1
Specifications
Body Sizes and End Connection Style
DN 15, 20, and 25 (1/2, 3/4, and 1-inch) NPT screwed
Maximum Allowable Inlet and Pilot Supply Pressures
Regulator Pressure Drops
Outlet Control Pressure Range
Maximum Outlet Pressures
Loading Pressure For Pressure-Loaded Regulator
Proof Test Pressure
(1)
Cast Iron: Steel:
Minimum: Maximum Operating:
pressure settings equal to or below 3,4 bar (50 psig); 13,8 bar (200 psig) for outlet pressure settings above 3,4 bar (50 psig)
Maximum Emergency:
bar (250 psig); Steel construction, 20,7 bar (300 psig)
0,3 to 4,8 bar (5 to 70 psig) with green pilot control spring, or 1,4 to 10,3 bar (20 to 150 psig) with red pilot control spring
Maximum Operating Outlet Pressure: Maximum Emergency Outlet (Casing) Pressure:
Iron construction, 17,2 bar (250 psig); Steel construction, 20,7 bar (300 psig)
Maximum allowable loading pressure is 17,2 bar (250 psig) for cast iron construction and 20,7 bar (300 psig) for steel construction; the maximum allowable diaphragm differential pressure of 10,3 bar (150 psig) for cast iron and steel constructions must not be exceeded.
All Pressure Retaining Components have been proof tested per Directive 97/23/EC - Annex 1, Section 7.4
17,2 bar (250 psig)
20,7 bar (300 psig)
(1)
1,0 bar (15 psig)
10,3 bar (150 psig) for outlet
Cast Iron construction, 17,2
(1)
(1)
10,3 bar (150 psig)
Cast
(1)
Maximum Temperature Capabilities
Cast Iron: Steel:
208°C (406°F)
260°C (500°F)
(1)
Installation
Only qualified personnel should install or service a regulator. Regulators should be installed, operated, and maintained in accordance with international and applicable codes and regulations, and Fisher instructions.
If the regulator vents fluid or a leak develops in the system, it indicates that service is required. Failure to take the regulator out of service immediately may create a hazardous condition.
Personal injury, equipment damage, or leakage due to escaping fluid or bursting of pressure­containing parts may result if this regulator is overpressured or is installed where service conditions could exceed the limits given in the Specifications section, or where conditions exceed any ratings of the adjacent piping or piping connections.
To avoid such injury or damage, provide pressure­relieving or pressure-limiting devices (as required by the appropriate code, regulation, or standard) to prevent service conditions from exceeding limits.
Additionally, physical damage to the regulator could result in personal injury and property damage due to escaping fluid. To avoid such injury and damage, install the regulator in a safe location.
Clean out all pipelines before installation of the regulator and check to be sure the regulator has not been damaged or has collected foreign material during shipping. For NPT bodies, apply pipe compound to the male pipe threads. For flanged bodies, use suitable line gaskets and approved piping and bolting practices. Install the regulator in any position desired, unless otherwise specified, but be sure flow through the body is in the direction indicated by the arrow on the body.
Note
It is important that the regulator be installed so that the vent hole in the spring case is unobstructed at all times. For outdoor installations, the regulator should be located away from vehicular traffic and positioned so that water, ice, and other foreign materials cannot enter the spring case through the vent. Avoid placing the regulator beneath eaves or downspouts, and be sure it is above the probable snow level.
1. The pressure/temperature limits in this installation guide and any applicable standard or code limitation should not be exceeded.
www.FISHERregulators.com
D100255XENG
Type 92C
Overpressure Protection
The recommended pressure limitations are stamped on the regulator nameplate. Some type of overpressure protection is needed if the actual inlet pressure exceeds the maximum operating outlet pressure rating. Overpressure protection should also be provided if the regulator inlet pressure is greater than the safe working pressure of the downstream equipment.
Regulator operation below the maximum pressure limitations does not preclude the possibility of damage from external sources or debris in the line. The regulator should be inspected for damage after any overpressure condition.
Startup
The regulator is factory set at approximately the midpoint of the spring range or the pressure requested, so an initial adjustment may be required to give the desired results. With proper installation completed and relief valves properly adjusted, slowly open the upstream and downstream shutoff valves.
Adjustment
To change the outlet pressure, remove the closing cap or loosen the locknut and turn the adjusting screw clockwise to increase outlet pressure or counterclockwise to decrease pressure. Monitor the outlet pressure with a test gauge during the adjustment. Replace the closing cap or tighten the locknut to maintain the desired setting.
Taking Out of Service (Shutdown)
To avoid personal injury resulting from sudden release of pressure, isolate the regulator from all pressure before attempting disassembly.
Parts List
Regulator
Key Description
1 Regulator Body Assembly
with bushing 2 Diaphragm Flange 3 Seat Ring 4 Valve Plug 5 Valve Plug Guide 6 Stem Guide Bushing 7 Valve Plug Spring 8 Diaphragm 9 Diaphragm Gasket 10 Pitot Tube 11 Stem Assembly 12 Cap Screw 13 Nameplate 14 Drive Screw 15 Diaphragm Ring
Type 6392 Pilot
Key Description
1 Pilot Body 2 Spring Case 3 Seat Ring 4 Valve Plug 5 Valve Plug Guide 6 Stem Assembly 7 Diaphragm 8 Diaphragm Gasket 9 Lower Spring Seat 10 Stem Guide Bushing 11 Valve Plug Spring 12 Strainer Screen 13 Control Spring 14 Upper Spring Seat 15 Jam Nut 16 Adjusting Screw 17 Cap Screw 18 Nameplate 19 Drive Screw 26 Valve Plug Cap
STEEL OR STAINLESS STEEL CONSTRUCTION
26A1536_A
CAST IRON CONSTRUCTION
16A1520_B
Figure 2. Type 6392 Pilot
Figure 1. Type 92C Regulator
©Fis her C ontro ls Inte rnati onal, I nc., 2002; All R ights Rese rved
Fisher and Fisher Regulators are marks owned by Fisher Controls International, Inc. The Emerson logo is a trade mark and service mark of Emerson Electric Co. All other marks are the property of their respective owners.
The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. We reserve the right to modify or improve the designs or specifications of such products at any time without notice.
For information, contact Fisher Controls, International:
Within USA (800) 588-5853 – Outside USA (972) 542-0132 France – (33) 23-733-4700 Singapore – (65) 770-8320 Mexico – (52) 57-28-0888
Printed in U.S.A.
www.FISHERregulators.com