ValveMate
™
7060RA Controller
Operating Manual
Electronic pdf files of EFD®manuals are also available at www.efd-inc.com/manuals.html
USA: 800-556-3484 or +1-401-434-1680
Europe: 0800 585733 or +44 (0) 1582 666334
Asia: +86 (21) 5854 2345
technical@efd-inc.com www.efd-inc.com
®
A NORDSON COMPANY
VALVEMATE
7060RA
M
M
M
A NORDSON COMPANY
Introduction and Specifications ..................................3
Operating Features ..................................................4-5
Controller Setup........................................................6-7
Adjusting the Spray ..................................................8-9
Input / Output Connections..................................10-11
Connecting More than One 7060RA Controller ........12
Troubleshooting Guide ..............................................13
Schematic and Replacement Parts List ....................14
Warranty ......................................................back cover
Contents
3 / Introduction and Specifications
The ValveMate7060RA provides nozzle air and drive motor on/off control
for the 782RA spray valve. The controller incorporates unique microprocessor
circuitry to provide exact time control and interact with the host computer.
A built-in air-pressure regulator provides LVLP (low volume low pressure)
nozzle air to ensure high transfer efficiency without overspray. The
ValveMate 7060RA is simple to use and will operate many millions of
cycles without maintenance.
Introduction
Specifications
Size: 19 x 14 x 7 cm (7.5” W x 5.6” D x 2.7” H)
Weight: 1.5 kg (3.3 lb)
Cabinet: Aluminum
Input Voltage: Selectable 100/120/220 VAC
Output circuit fuses: 5 x 20 mm cartridge fuses 315mA
Feedback Circuits: 5 to 24 VDC NC solid-state switch 250mA maximum
Initiate Circuit: 5 to 24 VDC momentary or dry contact closure
Air Input: 70 psi (4.8 bar)
Cycle Rate: Exceeds 400 per minute
Time Range: .001 to 99.9 seconds
Note: Specifications and technical
details are subject to engineering
changes without prior notification.
4 / Operating Features
1. Cycle / Test
Press to initiate one complete dispense cycle. Press again to interrupt
a timed cycle. Press and hold while
in the time override mode for continuous cycle. Release to stop.
2. Time override
Press to override timed deposit
mode. Display will show (---). While
in this mode, dispensing is manual
using the cycle button, voltage
initiate source or foot pedal (optional,
#2015A).
3. Time / Pressure and PSI / BAR toggle
Press to change digital display from
valve open-time to atomizing air pressure. Press and hold for three seconds to toggle between psi and bar.
Operating Features
VALVEMATE
7060RA
M
M
Atomizing
air regulator
123
546
Power
switch
M
®
A NORDSON COMPANY
5 / Operating Features
Operating Features
4. Program
Press to clear display to zeros. Display
flashes bright/dim while in program
mode. Press cycle button and hold
until proper amount is sprayed. Total
spray time will be displayed. Press
program button again to lock in
spray time.
5. Time set
Press to change time setting up or
down. Press and release to single step.
6. Motor control mode switch
Switch from OFF to continuous
ON for most applications or to
intermittent ON for low cycle use.
7. Foot pedal connector
If using the optional foot pedal, press
the pedal momentarily to initiate the
controller. To interrupt a timed dispense
cycle, press the pedal again.
220
7
Air input
quick-coupler
70 psi (4.8 bar)
minimum input
pressure
Valve
operating
air outlet
(white)
Atomizing
air outlet
(black)
Air
exhaust
I/O interface
terminal strip
Input power
cord receptacle
(see page 7)
Fuse 125 mA
100V 120V 220V
50/60Hz 20/17VA
1. Initiate +
2. Initiate -
3. Output +
4. Output -
5-24 VDC or
Contact Closure
5-24 VDC
250 mA
]
]
+- - -++-+
123456 87
Outlet B
Outlet A
Air Input
70 PSI
(4.8 bar)
Foot Pedal
5. Alarm +
6. Alarm -
7. Control Valve +
8. Control Valve -
5-24 VDC
250 mA
]