PTX/PDCR 1230
Specifications
General
Operating Ranges
• 1, 2.5 psi (0.75, 1.5 mH2O) gauge
• 5, 10, 15, 20, 30, 50, 75, 100, 150, 200, 300, 500,
900 psi (3.5, 7, 10, 15, 20, 35, 50, 70, 100, 150, 200, 350,
600 mH2O) gauge or absolute
Other pressure units can be specif ied.
Overpressure
• 10X for range 1 psig (0.75 mH
2
O)
• 8X 2.5 psi (1.5 mH2O)
• 6X 5 psi (1.5 to 3.5 mH2O)
• 4X for ranges above 5 psi (3.5 mH2O)
• 2000 psi (1400 mH2O) maximum
Pressure Media
Fluids compatible with titanium and polyurethane
Transduction Principal
Piezoresistive micromachined silicon strain gauge
Combined Error (Non-linearity, Hysteresis, and
Repeatability)
±0.25% full scale (FS) base standard line (BSL)
Temperature Effects Over Compensated Range of
30°F to 86°F (-1°C to 30°C)
±2.0% FS total error band (TEB) for ranges below 5 psi
(3.5 mH
2
O)
Resolution
Infinite
Insulation Resistance
100 MS @50 VDC
Relative Humidity
0 to 100%
Compensated Temperature Range
30°F to 86°F (-1°C to 30°C)
Operating Temperature Range
-5°F to 140°F (-20°C to 60°C)
Electrical Characteristics
Output
PTX 1230
Two-wire, 4 to 20 mA
PDCR 1230
• 25 mV/V for range 1 psi (0.75 mH
2
O)
• 5 mV/V for range 2.5 psi (1.5 and 3.5 mH2O)
• 10 mV/V for range 10 psi and above (7 mH2O)
Output is ratiometric to power supply (2.5 VDC minimum)
Electrical Connection
Vented polyurethane cable
Red
__
Positive supply
Black
__
Negative supply
Shield
__
connected to case
Any other conductors not connected.
Electrical Connection
Vented polyurethans cable
Red
__
Positive supply
White
__
Negative supply
Yellow
__
Positive output
Blue
__
Negative output
Shield
__
connected to case
Any other conductors not connected.
Installation Drawings
Ø 0.69 in
(17.5 mm)
7.8 in (198 mm) approximately
M14 x 1.5 in (38 mm) exposed
thread with nose cone removed
5/16 nominal
3.8 in (96.52 mm)
approximately
Length to order
M14 x 1.5 in (38 mm) exposed
thread with nose cone removed
5/16 nominal
Ø 0.69 in
(17.5 mm)
GE
Sensing
Length to order
PTX 1230
PDCR 1230