Druck PTX1210, PMP1210 Data sheet

Page 1
PTX/PMP 1200 Series
Industrial Pressure Transmitters
" ±0.25% FS accuracy
" NACE compatible wetted parts
" Low-cost, rugged construction
" Class I, Div 1, Intrinsically safe certified " Ranges from 2.5 to 10,000 psi
PTX/PMP 1200
Page 2
PTX/PMP 1200 Series
Industrial Pressure Transmitters
The PTX/PMP 1200 Series is a complete range of pressure transmitters designed to optimize the relationship between price and performance while providing flexibility from a standard production device.
At the heart of the 1200 Series is an advanced, high stability pressure measurement element, micro-machined from single crystal silicon within Druck’s own Class 100 processing facility. The silicon element is mounted within a high integrity glass to metal seal and is fully isolated from thepressure media by a hastelloy isolation diaphragm, electron beam welded to the front of the glass to metal seal. Druck’s proprietary low oil volume isolation allows fast dynamic response plus minimal thermal error . The high output silicon allows for high overload capability.
Silicon wafers being loaded into an oxidation furnace.
Applications include general purpose industrial, refrigeration, oil & gas well head monitoring and control, compressor performance monitoring and static pressure measurements in flow applications.
Surface mount electronics condition the output from the silicon diaphragm, correct for thermally induced errors, and configure the output to the required 4-20 mA or 1-5 Vdc output. Advanced design features built into the electronic circuitry enable minimum sensor size with the utmost reliability. The electronics incorporate power supply regulation, reverse polarity, overvoltage and shor t circuit protection, coupled with EMC protection components.
The fully encapsulated solid state design ensures integrity of product under high levels of shock and vibration, with an ingress protection rating of NEMA 4X, depending on electrical termination selected.
A fully tested pressure core is stocked in quantity , requiring only the addition of the electrical termination. Prior to shipping, the sensor is adjusted to meet the particular pressure range and units and terminated with the electrical connection.
Some configurations allow access to zero and span potentiometers for adjustments during set up and calibration. Others are fixed and cannot be adjusted.
A range of stainless steel pressure adapters are available to modify the standard 1/4”NPT female pressure port.
The PTX/PMP 1200 Series is ideally suited to meet the rigorous demands of the Industrial, Automotive, Aerospace and Oil & Gas markets. The PMP 1200 is designed for applications where batteries and/or solar powered systems require very low power consumption. The PTX/PMP 1240 is also being qualified for Class I, Div 1 Explosion-proof service.
Computerized testing and calibration of pressure transducers.
Page 3
Standard specification
SPECIFICATION
Operating Pressure Ranges
0 to 2.5, 5, 10 psig 15, 20, 30, 50, 60, 100, 200, 300, 500, 600, 750 psig or psia. 0 to 1000, 1500, 2000, 3000, 5000, 7500, 10,000, 15,000 psi sg or psia
-15 to +30 psig, 0 to -5 and 0 to -15 psig;
11.5 to 17.0 psia (Barometric)
Please refer to manufacturer for additional ranges.
Overpressure
The rated pressure can be exceeded by the following without degrading performance: 4x for ranges to 900 psi g 2x for ranges 1000 to 10,000 psi sg
1.5x for range 15,00 0 psi
Pressure Containment
6x Full Scale for vented gauge 2500 psi for all absolute and sealed gauge ranges 2000 psi and below 20,000 psi for all absolute and sealed gauge ranges above 2000 psi
Refer to manufacturer for higher containment
Pressure Media
Fluids compatible with 316L Stainless Steel and Hastelloy C276 (NACE compatible)
Supply Voltage
PTX 1200 9 to 30 Vdc The minimum supply voltage (V must appear across the transmitter
min
) that
terminals is 9 Vdc and is calculated by:
V
-(0.02xR1)
Where Vs is supply voltage in volts
min=Vs
RL is total loop resistance in ohms
PMP 1200 8-30 Vdc, <2mA
Output
PTX 1200 4-20mA (2-wire configuration)
PMP 1200 1-5 Vdc (less than 2mA)
Zero and Span Offset
±0.5% F.S.
Long term Stability
±0.2% F.S./annum
Combined Non-linearity, Hysteresis and Repeatability
±0.25% F.S. BSL maximum
Zero and Span Accessability
Models 1210, 1225 and 1265 only Zero ±5% FS Span ±5% FS
Temperature Limits
Process: -400 to +2500F Storage: -500 to +1850F Compensated: -40 to +1800F
Operating T emperature Range
-400 to +1850F
Temperature Effects
±2% F.S. typically; ±3% FS Thermal Error Band Maximum over compensated temperature range. Errors increase pro rata below 5 psi
Weight
10 oz. Nominal
Pressure Connection
1/4” NPT female to 10,000 psi 3/8” Autoclave for 10,00 0 & 15,0 0 0 psi ranges
Electrical Connection
1210 DIN connector zero and span
accessible
1225 Cable out with zero and span
accessible 1240 1/2” NPT male conduit fitting 1260 6 pin bayonet connection 1265 6 pin bayonet zero and span
accessible
Ingress Protection
Designed to meet Nema 4X when properly installed with conduit fitting connection
Voltage Spike Protection
Units will withstand 600V spike test to ENV 50142 without damage applied between excitations lines and case
Safety Classifications
UL Intrinsically Safe for Class I, Div 1, Grps A, B, C and D, Class II, Grps E, F, G cUL Intrinsically Safe for Class I, Div 1,
OPTIONS
Pressure port: 1/2” NPT female via adapter 1/4” NPT male via adapter 1/2” NPT male, welded adapter Conduit Fitting: 1/2” NPT female, via adapter CSA/FM/UL Approval (state which logo on transducer) Extra Cable Length (state length in feet or meters) NIST Room Temperature 9-pt Calibration Certificate Alternate Engineering Units (equivalent to standard psi ranges)
ORDERING INFORMATION
Please state the following: (1) Type number PTX or PMP 1200
Model
Code
2 wire, 4-20 mA current output
PTX PMP 3-wire, 1 to 5 Vdc, Low power
Code
DIN Connector (demountable)
1210 1225
Cable (demountable) 1/2” NPT Male Conduit Fitting
1240
6-pin Bayonet Connector1260 6-pin Bayonet Connector (demountable)
1265
(2) Operating pressure range (gauge, sealed gauge or absolute) (3) Options (if required)
Grps A, B, C and D, Class II, Grps E, F, G
Factory Mutual Approvals
Intrinsically Safe for Class I, Div 1, Grps A, B, C, D for hazardous locations
PTX/PMP 1240 only Explosion-proof and intrinsically safe for Class I, Div 1, Grps A, B, C, D; Class I, Div 2, Grps A, B, C, D; Class II, Grps E, F, G; Class III for hazardous locations
Canadian Standards Association (CSA) Approvals
Intrinsically Safe in hazardous locations Class I, Div 1, Grps A, B, C, D
PTX/PMP 1240 only
RELATED PRODUCTS
LPM/LPX 800 0 Series Wet/Wet Low Pressure
Differential PTX 500/60 0 Pressure Transmitters PTX 1230/1830 Submersible Pressure
Transmitters MDK-24/MDK-LV Lightning Arresters DPI 610/615 Portable Pressure Calibrators DPI 280 Series Indicators
Please refer to the manufacturer for further information and data sheets.
Continuing development sometimes necessitates specification changes without notice.
Explosion-proof and intrinsically safe in in hazardous locations Class I, Div 1, Grps A, B, C, D; Class I, Div 2, Grps A, B, C, D; Class II, Grps E, F, G;
Druck is an ISO 9001 registered company.
Class III
Venting is provided by a flame-arresting filter designed to allow the transmitter to breathe while preventing the ingress of fluids.
Wiring Details
Function
PTX/PMP
1225/1240
PTX/PMP
1260/1265
PTX/PMP
1210
Wire Color Pin Letter Pin Number
Supply + Red A (1) Supply – Black B (2) Output + (PMP White C (3) versions only) Case Ground Shield F ( )
ABCDE
Page 4
PTX/PMP 1200 Series
Industrial Pressure Transmitters
Installation Drawings - dimensions in inches
(1210 demountable)
A full range of alternative cable and connector versions are available­refer to Druck for further information
Associated Products
(1240 fixed)
(1260 fixed)
Druck manufactures a comprehensive range of pressure instrumentation to complement the PTX/PMP 1200 Series.
Portable pressure, temperature and electrical field calibrators allow for local calibration reducing plant down time while maintaining the quality requirements of ISO 9000. In addition, the Druck range of calibration equipment is completed by primary standard deadweight testers.
(1225 demountable)
(1265 demountable)
Left: DPI 610 Field Portable Pressure Calibrator Center: DPI 145 Multi-Function Digital Meter Right: DPI 605 Precision Portable Pressure Calibrator Inset: LP Series of Low Pressure Sensors
Druck Incorporated
4 Dunham Drive New Fairfield CT 06812 Tel: (203) 746-0400 Fax: (203) 746-2494 E-Mail:usa.sales@druck.com http://www.druck.com
cd
http://www.pressure.com
The LP Series provides full scale absolute ranges as low as 0.03 psia and differential ranges as low as ±0.04 inches H2O wet/wet differential pressure.
For further information and product data sheets- refer to Druck.
Representative
PDS- A083 9/01