INSTALLATION INSTRUCTION
Detcon Remote Cal /
Remote Sensor Separation Kit
Remote
condulet with
sensor
Tubing for Cal
Gas
wiring to Control
Monitor
Sensor
Transmitter
Applies to all Remote Separation Kits
February 18, 2009• Document #2178• Revision 2.1
The Woodlands, Texas 77387
Ph.281.367.4100 / Fax 281.298.2868
DETCON, Inc.
3200 Research Forest Dr.,
www.detcon.com

Remote Cal Kit
Page intentionally blank
Phone: 888.367.4286, 281.367.4100 • Fax: 281.292.2860 •
Remote Cal Kit Remote_Cal_Kit_R21.doc ii
Shipping Address: 3200 A-1 Research Forest Dr., The Woodlands Texas 77381
Mailing Address: P.O. Box 8067, The Woodlands Texas 77387-8067
www.detcon.com • sales@detcon.com

Remote Cal Kit
1. Remove the sensor from the Transmitter Assembly and install the sensor on the Remote Condulet.
2. Install and wire the Sensor to the Terminal Board in the Remote Condulet as described in Figure 3.
3. Locate the most appropriate place(s), and Mount the Remote Condulet with Sensor and Transmitter
Assembly as shown in Figure 1.
4. Route the wiring from the Remote Condulet Terminal Board to the Sensor Transmitter Assembly.
Reference the Sensor Manual and wire the Remote Sensor to the Transmitter Assembly.
3
"NPT
4
Remote
condulet with
sensor
16AWG wire. (wire count
dependent on sensor type.)
Tubing for Cal
Gas
See Sensor Manual for
maximum distance.
Elevation eye level
Plug all unused
3
"NPT Ports
4
Figure 1 Remote Mounting
5. Install the splashguard with integral calibration port on the sensor.
Splash Guard
Calibration Port
Teflon Tubing
Sensor
Transmitter
2 or 3 conductor
wiring to Control
Monitor
Figure 2 Remote Calibration Tubing
Remote Cal Kit Rev. 2.1 Page 1 of 2

Remote Cal Kit
6. Connect ¼” Teflon sample tubing to the calibration port on the splashguard (Figure 2). Push the tubing
onto the calibration port until it seats completely.
7. TP & FP series sensors only: Reference the “Remote Mount Applications” section of the sensor
instruction manual for details on setting sensor heater/bridge voltages at the remote sensor location. Set
the heater/bridge voltage appropriately.
8. Calibrate the sensor to insure proper operation.
To Transmitter
Wht
Blk
Blu
Install Jumper
To Transmitter
Wht
Blk
Blu
Yel
To Transmitter
Wht
Blk
Blu
Yel
Wht
Blk
Yel
Blu
To FP Sensor
FP Combustible Series
To Transmitter
Red
Brn
Blk
Wth
Blu
Yel
Red
Brn
Wht
Blk
Yel
Blu
To IR Sensor
IR Infrared Series
Wht
Blk
Yel
Blu
To TP Sensor
Wht
Blk
Yel
Blu
To PI Sensor
TP Solid State H2S Series PID Universal VOC Sensor's
To Transmitter
Wht
Blu
Wht
Blu
To O2 Sensor
DM Oxygen Series
To Transmitter
Wht
Blk
Wht
Blk
NOTE: cut yellow wire off
if used with DM-500IS or
Blu
Yel
Yel
Blu
DM-600IS Sensors.
To IS Sensor
IS Toxic Series Sensors
Figure 3 Remote Condulet Wiring
Remote Cal Kit Rev. 2.1 Page 2 of 2