Dell PowerConnect 5524,PowerConnect 5524P,PowerConnect 5548,PowerConnect 5548P System User's Manual

Dell PowerConnect 5500 Series

System User Guide
FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\Maintenance Projects\Dell
DELL CONFIDENTIAL – PRELIMINARY 10/30/13 – FOR PROOF ONLY
Regulatory Models: PowerConnect 5524, 5524P, 5548, 5548P
Contax\sources\CxUGCover.fm
Template Last Updated -03/06/2010
NOTE: A NOTE indicates important information that helps you
make better use of your system.
CAUTION: A CAUTION indicates potential damage to
hardware or loss of data if instructions are not followed.
WARNING: A WARNING indicates a potential for property
damage, personal injury, or death.
____________________
Information in this document is subject to change without notice. © 2013 Dell Inc. All rights reserved.
Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden.
Trademarks used in this text: Dell™, the DELL logo, Dell Precision™, OptiPlex™, Latitude™, PowerEdge™, PowerVault™, PowerConnect™, OpenManage™, EqualLogic™, KACE™, FlexAddress™ and Vostro™ are trademarks of Dell Inc. Intel registered trademarks of Intel Corporation in the U.S. and other countries.
®
is a registered trademark and AMD Opteron™, AMD Phenom™, and
AMD AMD Sempron™ are trademarks of Advanced Micro Devices, Inc. Microsoft Windows trademarks or registered trademarks of Microsoft Corporation in the United States and/or other countries. Red Hat Enterprise Linux are registered trademarks of Red Hat, Inc. in the United States and/or other countries. Novell Novell Inc. in the United States and other countries. Oracle trademark of Oracle Corporation and/or its affiliates. Citrix and XenMotion Systems, Inc. in the United States and/or other countries. VMware SMP trademarks of VMWare, Inc. in the United States or other countries.
Other trademarks and trade names may be used in this publication to refer to either the entities claiming the marks and names or their products. Dell Inc. disclaims any proprietary interest in trademarks and trade names other than its own.
Regulatory Models PC5524, PC5524P, PC5548 and PC5548P
October 2013 A08
®
, Windows Server®, MS-DOS® and Windows Vista® are either
®
is a registered trademark and SUSE ™ is a trademark of
®
are either registered trademarks or trademarks of Citrix
®
, vMotion®, vCenter®, and vSphere® are registered trademarks or
®
, Pentium®, Xeon®, Core™ and Celeron® are
®
and Enterprise Linux®
®
is a registered
®
, Xen®, XenServer®
®
, Virtual
®
,
FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\Maintenance
Projects\Dell Contax\sources\Dell_ContaxUG_PrintTOC.fm

Contents

ContentsContents
1 Preface . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2 Features. . . . . . . . . . . . . . . . . . . . . . . . . . 15
IP Version 6 (IPv6) Support . . . . . . . . . . . . . . . 16
Stack Support . . . . . . . . . . . . . . . . . . . . . . 16
Power over Ethernet
Green Ethernet
Head of Line Blocking Prevention. . . . . . . . . . . . 17
Flow Control Support (IEEE 802.3X)
Back Pressure Support
Virtual Cable Testing (VCT) . . . . . . . . . . . . . . . 18
Auto-Negotiation
MDI/MDIX Support
MAC Address Supported Features . . . . . . . . . . . 18
. . . . . . . . . . . . . . . . . . . 16
. . . . . . . . . . . . . . . . . . . . . . 17
. . . . . . . . . . . 17
. . . . . . . . . . . . . . . . . 17
. . . . . . . . . . . . . . . . . . . . 18
. . . . . . . . . . . . . . . . . . . . 18
Contents
3
FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\Maintenance
Projects\Dell Contax\sources\Dell_ContaxUG_PrintTOC.fm
Layer 2 Features . . . . . . . . . . . . . . . . . . . . . 20
IGMP Snooping
. . . . . . . . . . . . . . . . . . . . . . 20
Port Mirroring . . . . . . . . . . . . . . . . . . . . . . 20
Broadcast Storm Control
VLAN Supported Features
. . . . . . . . . . . . . . . . . 20
. . . . . . . . . . . . . . . . 21
Spanning Tree Protocol Features . . . . . . . . . . . . 22
Link Aggregation
Quality of Service Features
. . . . . . . . . . . . . . . . . . . . . 24
. . . . . . . . . . . . . . . 24
Device Management Features. . . . . . . . . . . . . . 25
Security Features
Port Profile (CLI Macro)
. . . . . . . . . . . . . . . . . . . . 29
. . . . . . . . . . . . . . . . . 31
DHCP Server . . . . . . . . . . . . . . . . . . . . . . . 32
Protected Ports
iSCSI Optimization
. . . . . . . . . . . . . . . . . . . . . . 32
. . . . . . . . . . . . . . . . . . . . 32
Proprietary Protocol Filtering . . . . . . . . . . . . . . 32
3 Hardware Description . . . . . . . . . . . . . . 35
4 Contents
Device Models . . . . . . . . . . . . . . . . . . . . . . 36
Device Structure
. . . . . . . . . . . . . . . . . . . . . 36
LED Definitions. . . . . . . . . . . . . . . . . . . . . . 40
Power Supplies
. . . . . . . . . . . . . . . . . . . . . 44
FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\Maintenance
Projects\Dell Contax\sources\Dell_ContaxUG_PrintTOC.fm
4 Stacking Overview . . . . . . . . . . . . . . . . . 45
Stack Overview . . . . . . . . . . . . . . . . . . . . . 46
Stack Members and Unit IDs . . . . . . . . . . . . . . 49
5 Configuring the Switch . . . . . . . . . . . . . . 57
Configuration Work Flow . . . . . . . . . . . . . . . . 58
Connecting the Switch to the Terminal
. . . . . . . . . 59
Booting the Switch . . . . . . . . . . . . . . . . . . . 60
Configuring the Stack
Configuration Using the Setup Wizard
. . . . . . . . . . . . . . . . . . 61
. . . . . . . . . 61
6 Advanced Switch Configuration . . . . . . . 67
Using the CLI . . . . . . . . . . . . . . . . . . . . . . . 68
Accessing the Device Through the CLI
Retrieving an IP Address
. . . . . . . . . . . . . . . . 72
Security Management and Password Configuration . . 75
Configuring Login Banners
Startup Menu Procedures
. . . . . . . . . . . . . . . 78
. . . . . . . . . . . . . . . . 80
Software Download . . . . . . . . . . . . . . . . . . . 83
. . . . . . . . . 71
7 Using Dell OpenManage Administrator. . 87
Starting the Application . . . . . . . . . . . . . . . . . 88
Contents
5
FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\Maintenance
Projects\Dell Contax\sources\Dell_ContaxUG_PrintTOC.fm
Understanding the Interface . . . . . . . . . . . . . . . 88
Using the Switch Administrator Buttons
. . . . . . . . 91
Field Definitions . . . . . . . . . . . . . . . . . . . . . 93
Common GUI Features
GUI Terms
. . . . . . . . . . . . . . . . . . . . . . . . . 94
. . . . . . . . . . . . . . . . . . 93
CLI Commands . . . . . . . . . . . . . . . . . . . . . . 94
8 Network Security. . . . . . . . . . . . . . . . . . 97
Port Security . . . . . . . . . . . . . . . . . . . . . . . 98
. . . . . . . . . . . . . . . . . . . . . . . . . . 103
ACLs
ACL Binding . . . . . . . . . . . . . . . . . . . . . . 123
Proprietary Protocol Filtering
Time Range
. . . . . . . . . . . . . . . . . . . . . . . 127
Dot1x Authentication. . . . . . . . . . . . . . . . . . 132
. . . . . . . . . . . . . 125
9 Configuring System Information . . . . . . 155
6 Contents
General Switch Information . . . . . . . . . . . . . . 156
Time Synchronization
. . . . . . . . . . . . . . . . . 169
Logs. . . . . . . . . . . . . . . . . . . . . . . . . . . 195
IP Addressing
Diagnostics
. . . . . . . . . . . . . . . . . . . . . 209
. . . . . . . . . . . . . . . . . . . . . . . 255
Management Security . . . . . . . . . . . . . . . . . 261
FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\Maintenance
Projects\Dell Contax\sources\Dell_ContaxUG_PrintTOC.fm
DHCP Server . . . . . . . . . . . . . . . . . . . . . . . 297
. . . . . . . . . . . . . . . . . . . . . . . . . . 314
SNMP
File Management . . . . . . . . . . . . . . . . . . . . 337
Stack Management
. . . . . . . . . . . . . . . . . . . . . . . . . . 375
sFlow
. . . . . . . . . . . . . . . . . . . 367
10 Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . 385
Overview . . . . . . . . . . . . . . . . . . . . . . . . . 386
Jumbo Frames
Green Ethernet Configuration
Protected Ports . . . . . . . . . . . . . . . . . . . . . 395
Port Profile
Port Configuration
LAG Configuration . . . . . . . . . . . . . . . . . . . . 410
Storm Control
Port Mirroring
. . . . . . . . . . . . . . . . . . . . . . 389
. . . . . . . . . . . . . . 391
. . . . . . . . . . . . . . . . . . . . . . . . 398
. . . . . . . . . . . . . . . . . . . . 404
. . . . . . . . . . . . . . . . . . . . . . 415
. . . . . . . . . . . . . . . . . . . . . . 418
11 Address Tables . . . . . . . . . . . . . . . . . . . 423
Overview . . . . . . . . . . . . . . . . . . . . . . . . . 424
Static Addresses
Dynamic Addresses
. . . . . . . . . . . . . . . . . . . . . 425
. . . . . . . . . . . . . . . . . . . 428
Contents
7
FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\Maintenance
Projects\Dell Contax\sources\Dell_ContaxUG_PrintTOC.fm
12 GARP . . . . . . . . . . . . . . . . . . . . . . . . . . . 431
GARP Overview . . . . . . . . . . . . . . . . . . . . 432
GARP Timers . . . . . . . . . . . . . . . . . . . . . . 433
13 Spanning Tree . . . . . . . . . . . . . . . . . . . . 435
Spanning Tree Protocol Overview. . . . . . . . . . . 436
Global Settings
. . . . . . . . . . . . . . . . . . . . . 438
STP Port Settings. . . . . . . . . . . . . . . . . . . . 443
STP LAG Settings
Rapid Spanning Tree
. . . . . . . . . . . . . . . . . . . . 448
. . . . . . . . . . . . . . . . . . 451
Multiple Spanning Tree . . . . . . . . . . . . . . . . 455
14 VLANs . . . . . . . . . . . . . . . . . . . . . . . . . . 467
Virtual LAN Overview . . . . . . . . . . . . . . . . . 468
VLAN Membership
Port Settings . . . . . . . . . . . . . . . . . . . . . . 476
LAGs Settings
Protocol Groups
Protocol Port . . . . . . . . . . . . . . . . . . . . . . 489
GVRP Parameters
. . . . . . . . . . . . . . . . . . . 473
. . . . . . . . . . . . . . . . . . . . . 482
. . . . . . . . . . . . . . . . . . . . 485
. . . . . . . . . . . . . . . . . . . 491
8 Contents
Private VLAN
. . . . . . . . . . . . . . . . . . . . . . 495
Voice VLAN. . . . . . . . . . . . . . . . . . . . . . . 499
FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\Maintenance
Projects\Dell Contax\sources\Dell_ContaxUG_PrintTOC.fm
15 Link Aggregation . . . . . . . . . . . . . . . . . . 509
Link Aggregation Overview . . . . . . . . . . . . . . . 510
LACP Parameters . . . . . . . . . . . . . . . . . . . . 512
LAG Membership
. . . . . . . . . . . . . . . . . . . . 515
16 Multicast . . . . . . . . . . . . . . . . . . . . . . . . 517
Multicast Support Overview. . . . . . . . . . . . . . . 518
Global Parameters . . . . . . . . . . . . . . . . . . . . 520
Bridge Multicast Groups
Bridge Multicast Forward All
. . . . . . . . . . . . . . . . 522
. . . . . . . . . . . . . . 526
IGMP Snooping . . . . . . . . . . . . . . . . . . . . . 528
Unregistered Multicast
Multicast TV VLAN
. . . . . . . . . . . . . . . . . 534
. . . . . . . . . . . . . . . . . . . . 536
17 LLDP . . . . . . . . . . . . . . . . . . . . . . . . . . . 541
LLDP Overview. . . . . . . . . . . . . . . . . . . . . . 542
LLDP Properties
. . . . . . . . . . . . . . . . . . . . . 543
LLDP Port Settings
. . . . . . . . . . . . . . . . . . . . 547
MED Network Policy . . . . . . . . . . . . . . . . . . 550
LLDP MED Port Settings
Neighbors Information
. . . . . . . . . . . . . . . . . 553
. . . . . . . . . . . . . . . . . . 558
Contents
9
FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\Maintenance
Projects\Dell Contax\sources\Dell_ContaxUG_PrintTOC.fm
18 Dynamic ARP Inspection . . . . . . . . . . . . 561
Dynamic ARP Inspection Overview . . . . . . . . . . 562
Global Settings. . . . . . . . . . . . . . . . . . . . . 563
Dynamic ARP Inspection List
Dynamic ARP Inspection Entries
. . . . . . . . . . . . . 565
. . . . . . . . . . . 567
VLAN Settings . . . . . . . . . . . . . . . . . . . . . 569
Trusted Interfaces
. . . . . . . . . . . . . . . . . . . 571
19 DHCP Snooping . . . . . . . . . . . . . . . . . . . 573
DHCP Snooping . . . . . . . . . . . . . . . . . . . . 574
DHCP Relay. . . . . . . . . . . . . . . . . . . . . . . 587
20 iSCSI Optimization . . . . . . . . . . . . . . . . . 595
Optimizing iSCSI Overview . . . . . . . . . . . . . . 596
Global Parameters
iSCSI Targets . . . . . . . . . . . . . . . . . . . . . . 602
iSCSI Sessions
. . . . . . . . . . . . . . . . . . . 599
. . . . . . . . . . . . . . . . . . . . . 604
21 Statistics/RMON . . . . . . . . . . . . . . . . . . 607
10 Contents
Configuring iSCSI Using CLI
. . . . . . . . . . . . . . 606
Table Views . . . . . . . . . . . . . . . . . . . . . . 608
RMON Components
. . . . . . . . . . . . . . . . . . 626
FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\Maintenance
Projects\Dell Contax\sources\Dell_ContaxUG_PrintTOC.fm
Charts . . . . . . . . . . . . . . . . . . . . . . . . . . 644
22 Quality of Service . . . . . . . . . . . . . . . . . 651
QoS Features and Components . . . . . . . . . . . . . 652
General. . . . . . . . . . . . . . . . . . . . . . . . . . 654
QoS Basic Mode
QoS Advanced Mode
QoS Statistics . . . . . . . . . . . . . . . . . . . . . . 699
. . . . . . . . . . . . . . . . . . . . . 670
. . . . . . . . . . . . . . . . . . 679
Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . 706
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 721
Revision History . . . . . . . . . . . . . . . . . . . . . . 737
Contents
11
FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\Maintenance
Projects\Dell Contax\sources\Dell_ContaxUG_PrintTOC.fm
12 Contents
1

Preface

PowerConnect 5524/5548 and PowerConnect 5524P/5548P are stackable, advanced multi-layer devices.
This guide contains the information needed for installing, configuring, and maintaining the device through the web-based management system, called the OpenManage Switch Administrator.
This guide describes how to configure each system through the web-based management system and through CLI commands.
The
CLI Reference Guide,
provides additional information about the CLI commands.
which is available on the Documentation CD,
DELL CONFIDENTIAL – PRELIMINARY 10/30/13 - FOR PROOF ONLY
Dell PowerConnect 55xx Systems User Guide 13
FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\Maintenance Projects\Dell
Contax\sources\CxUGPrefix.fm
DELL CONFIDENTIAL – PRELIMINARY 10/30/13 - FOR PROOF ONLY
14 Dell PowerConnect 55xx Systems User Guide
2

Features

This section describes the features of the PowerConnect 5524/P and 5548/P switches.
For a complete list of all updated device features, see the latest software version Release Notes.
This section contains the following topics:
IP Version 6 (IPv6) Support
•Stack Support
Power over Ethernet
Green Ethernet
Head of Line Blocking Prevention
Flow Control Support (IEEE 802.3X)
•Back Pressure Support
Virtual Cable Testing (VCT)
Auto-Negotiation
MDI/MDIX Support
MAC Address Supported Features
Layer 2 Features
IGMP Snooping
Port Mirroring
Broadcast Storm Control
•VLAN Supported Features
Spanning Tree Protocol Features
Link Aggregation
Quality of Service Features
Quality of Service Features
Device Management Features
DELL CONFIDENTIAL – PRELIMINARY 10/30/13 - FOR PROOF ONLY
Dell PowerConnect 55xx Systems User Guide 15
FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\Maintenance Projects\Dell
Security Features
•DHCP Server
•Protected Ports
iSCSI Optimization
Proprietary Protocol Filtering
Contax\sources\CxUGFeatures.fm

IP Version 6 (IPv6) Support

The device functions as an IPv6-compliant host, as well as an IPv4 host (also known as dual stack). This enables device operation in a pure IPv6 network as well as in a combined IPv4/IPv6 network.
For more information, see "IP Addressing" on page 209.

Stack Support

The system supports up to eight units with two fixed HDMI stacking ports. The HDMI ports are 1.3a specification, Category 2 High Speed cables, 340 MHz (10.2 Gbit/s).
it is recommended to use HDMI cable version 1.4
The stacking feature supports the following features:
•Fast-link failover
Software auto-synch.
Improved response time to events, such as master failover
Auto-numbering algorithm when choosing unit number
For more information, see "Stacking Overview" on page 45

Power over Ethernet

Power over Ethernet (PoE) provides power to devices over existing LAN cabling, without updating or modifying the network infrastructure. When PoE is used, the network devices do not have to be placed next to a power source. PoE can be used in the following applications:
IP Phones
Wireless Access Points
DELL CONFIDENTIAL – PRELIMINARY 10/30/13 - FOR PROOF ONLY
16 Dell PowerConnect 55xx Systems User Guide
FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\Maintenance Projects\Dell
•IP Gateways
•PDAs
Audio and video remote monitoring
For more information, see "Power over Ethernet" on page 162.
Contax\sources\CxUGFeatures.fm

Green Ethernet

Green Ethernet, also known as Energy Efficient Ethernet (EEE), is an effort to make networking equipment environmentally friendly, by reducing the power usage of Ethernet connections.
The Short-Reach method, which reduces power over Ethernet cables shorter than 40m, is supported by the device.
For more information, see "Green Ethernet Configuration" on page 391.

Head of Line Blocking Prevention

Head of Line (HOL) blocking results in traffic delays and frame loss caused by traffic competing for the same egress port resources. To prevent HOL blocking, the device queues packets, and packets at the head of the queue are forwarded before packets at the end of the queue.

Flow Control Support (IEEE 802.3X)

Flow control enables lower-speed devices to communicate with higher-speed devices, by requesting that the higher-speed device refrain from sending packets. Transmissions are temporarily halted to prevent buffer overflows.
For more information, see "Flow Control" on page 387.

Back Pressure Support

On half-duplex links, the receiving port prevents buffer overflows by occupying the link so that it is unavailable for additional traffic.
For more information, see "Protected Ports" on page 395.
DELL CONFIDENTIAL – PRELIMINARY 10/30/13 - FOR PROOF ONLY
Dell PowerConnect 55xx Systems User Guide 17
FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\Maintenance Projects\Dell
Contax\sources\CxUGFeatures.fm

Virtual Cable Testing (VCT)

VCT detects and reports copper link cabling faults, such as open cables and cable shorts.
For more information, see "Diagnostics" on page 255.

Auto-Negotiation

Auto-negotiation enables the device to advertise modes of operation. The auto-negotiation function enables an exchange of information between two devices that share a point-to-point link segment, and automatically configures both devices to take maximum advantage of their transmission capabilities.
The PowerConnect 5500 series enhances auto-negotiation by providing port advertisement. Port advertisement enables the system administrator to configure the port speeds that are advertised.
For more information, see "Port Configuration" on page 404 or "LAG Configuration" on page 410.

MDI/MDIX Support

Standard wiring for end stations is known as Media-Dependent Interface (MDI), and standard wiring for hubs and switches is known as Media- Dependent Interface with Crossover (MDIX).
If auto-negotiation is enabled, the device automatically detects whether the cable connected to an RJ-45 port is MDIX (crossed) or MDI (straight). This enables both types to be used interchangeably.
If auto-negotiation is not enabled, only MDI (straight) cables can be used.
For more information, see "Port Configuration" on page 404 or "LAG Configuration" on page 410.

MAC Address Supported Features

MAC Address Capacity Support

The device supports up to 16K MAC addresses and it reserves specific MAC addresses for system use.
DELL CONFIDENTIAL – PRELIMINARY 10/30/13 - FOR PROOF ONLY
18 Dell PowerConnect 55xx Systems User Guide
FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\Maintenance Projects\Dell
Contax\sources\CxUGFeatures.fm

Static MAC Entries

MAC entries can be manually entered in the Bridging Table, as an alternative to learning them from incoming frames. These user-defined entries are not subject to aging, and are preserved across resets and reboots.
For more information, see "Static Addresses" on page 425.

Self-Learning MAC Addresses

The device enables controlled MAC address learning from incoming packets. The MAC addresses are stored in the Bridging Table.
For more information, see "Dynamic Addresses" on page 428.

Automatic Aging for MAC Addresses

MAC addresses from which no traffic is received for a given period, are aged out. This prevents the Bridging Table from overflowing.
For more information, see "Dynamic Addresses" on page 428.

VLAN-Aware MAC-Based Switching

The device always performs VLAN-aware bridging. Classic bridging (IEEE802.1D), in which frames are forwarded based only on their destination MAC address, is not performed. However, a similar functionality can be configured for untagged frames. Frames addressed to a destination MAC address that is not associated with any port are flooded to all ports of the relevant VLAN.

MAC Multicast Support

Multicast service is a limited Broadcast service that enables one-to-many and many-to-many connections for information distribution. In Layer 2 Multicast service, a single frame is addressed to a specific Multicast address, from which copies of the frame are transmitted to the relevant ports. When Multicast groups are statically enabled, you can set the destination port of registered groups, as well as define the behavior of unregistered Multicast frames.
For more information, see "Multicast" on page 517.
DELL CONFIDENTIAL – PRELIMINARY 10/30/13 - FOR PROOF ONLY
Dell PowerConnect 55xx Systems User Guide 19
FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\Maintenance Projects\Dell
Contax\sources\CxUGFeatures.fm

Layer 2 Features

IGMP Snooping

Internet Group Membership Protocol (IGMP) Snooping examines IGMP frame contents, when they are forwarded by the device from work stations to an upstream Multicast router. From the frame, the device identifies work stations configured for Multicast sessions, and which Multicast routers are sending Multicast frames. The IGMP Querier simulates the behavior of a Multicast router. This enables snooping of the Layer 2 Multicast domain even if there is no Multicast router.
For more information, see "IGMP Snooping" on page 528.

Port Mirroring

Port mirroring monitors network traffic by forwarding copies of incoming and outgoing packets from a monitored port to a monitoring port. Users specify which target port receives copies of all traffic passing through a specified source port.
For more information, see "Port Mirroring" on page 418.

Broadcast Storm Control

Storm Control enables limiting the number of Multicast and Broadcast frames accepted by and forwarded by the device.
When Layer 2 frames are forwarded, Broadcast and Multicast frames are flooded to all ports on the relevant VLAN. This occupies bandwidth, and loads all nodes connected on all ports.
For more information, see "Storm Control" on page 415.
DELL CONFIDENTIAL – PRELIMINARY 10/30/13 - FOR PROOF ONLY
20 Dell PowerConnect 55xx Systems User Guide
FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\Maintenance Projects\Dell
Contax\sources\CxUGFeatures.fm

VLAN Supported Features

VLAN Support

VLANs are collections of switching ports that comprise a single Broadcast domain. Packets are classified as belonging to a VLAN, based on either the VLAN tag or on a combination of the ingress port and packet contents. Packets sharing common attributes can be grouped in the same VLAN.
For more information, see "VLANs" on page 467.

Port-Based Virtual LANs (VLANs)

Port-based VLANs classify incoming packets to VLANs, based on their ingress port.
For more information, see "Defining VLAN Membership Using CLI Commands" on page 474.

Full 802.1Q VLAN Tagging Compliance

IEEE 802.1Q defines an architecture for virtual, bridged LANs, the services provided in VLANs, and the protocols and algorithms involved in the provision of these services.
For more information, see "Virtual LAN Overview" on page 468.

GVRP Support

GARP VLAN Registration Protocol (GVRP) provides IEEE 802.1Q­compliant VLAN pruning and dynamic VLAN creation. When GVRP is enabled, the device registers and propagates VLAN membership on all ports that are part of the active underlying Spanning Tree Protocol topology.
For more information, see "GVRP Parameters" on page 491.

Voice VLAN

Voice VLA N en abl es n e tw o rk administrators to enhance VoIP service by configuring ports to carry IP voice traffic from IP phones on a specific VLAN. VoIP traffic has a preconfigured OUI prefix in the source MAC address. Network administrators can configure VLANs from which voice IP traffic is
DELL CONFIDENTIAL – PRELIMINARY 10/30/13 - FOR PROOF ONLY
Dell PowerConnect 55xx Systems User Guide 21
FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\Maintenance Projects\Dell
forwarded. Non-VoIP traffic is dropped from the Voice VLAN in Auto-Voice VLAN Secure mode. Voice VLAN also provides QoS to VoIP, ensuring that the quality of voice does not deteriorate if the IP traffic is received unevenly.
For more information, see "Voice VLAN" on page 499.
Contax\sources\CxUGFeatures.fm

Guest VLAN

Guest VLAN provides limited network access to unauthorized ports. If a port is denied network access via port-based authorization, but the Guest VLAN is enabled, the port receives limited network access through the Guest VLAN.
For more information, see "Dot1x Authentication" on page 132.

Private VLAN

The Private VLAN feature provides Layer 2 isolation between ports that share the same Broadcast domain, or in other words, it creates a point-to­multipoint Broadcast domain. The ports can be located anywhere in the Layer 2 network (compared to the Protected Ports feature, where the ports must be in the same stack).
For more information, see "Private VLAN" on page 495.

Multicast TV VLAN

The Multicast TV VLAN feature provides the ability to supply multicast transmissions to Layer 2-isolated subscribers, without replicating the multicast transmissions for each subscriber VLAN. The subscribers are the only receivers of the multicast transmissions.
For more information, see "Multicast TV VLAN" on page 536.

Spanning Tree Protocol Features

Spanning Tree Protocol (STP)

802.1d Spanning tree is a standard Layer 2 switch requirement that enables bridges to automatically prevent and resolve Layer 2 forwarding loops. Switches exchange configuration messages using specifically-formatted frames, and selectively enable and disable forwarding on ports.
For more information, see "Spanning Tree" on page 435.
DELL CONFIDENTIAL – PRELIMINARY 10/30/13 - FOR PROOF ONLY
22 Dell PowerConnect 55xx Systems User Guide
FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\Maintenance Projects\Dell
Contax\sources\CxUGFeatures.fm

Fast Link

STP can take 30–60 seconds to converge. During this time, STP detects possible loops, enabling time for status changes to propagate and for relevant devices to respond. This period of 30-60 seconds is considered too long a response time for many applications. The Fast Link option bypasses this delay, and can be used in network topologies, where forwarding loops do not occur.
For more information on enabling Fast Link for ports and LAGs, see "STP
or
Port Settings" on page 443
"Static Addresses" on page 425.

IEEE 802.1w Rapid Spanning Tree

Spanning Tree takes 30–60 seconds for each host to decide whether its ports are actively forwarding traffic. Rapid Spanning Tree (RSTP) detects uses of network topologies to enable faster convergence, without creating forwarding loops.
For more information, see "Spanning Tree" on page 435.

IEEE 802.1s Multiple Spanning Tree

Multiple Spanning Tree (MSTP) operation maps VLANs into STP instances. MSTP provides a different load balancing scenario. Packets assigned to various VLANs are transmitted along different paths within MSTP Regions (MST Regions). Regions are one or more MSTP bridges by which frames can be transmitted. The standard lets administrators assign VLAN traffic to unique paths.
For more information, see "Spanning Tree" on page 435.

STP BPDU Guard

BPDU Guard is used as a security mechanism, to protect the network from invalid configurations.
BPDU Guard is usually used either when fast link ports (ports connected to clients) are enabled or when the STP feature is disabled. When it is enabled on a port, the port is shut down if a BPDU message is received and an appropriate SNMP trap is generated.
For more information, see "Spanning Tree" on page 435.
DELL CONFIDENTIAL – PRELIMINARY 10/30/13 - FOR PROOF ONLY
Dell PowerConnect 55xx Systems User Guide 23
FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\Maintenance Projects\Dell
Contax\sources\CxUGFeatures.fm

Link Aggregation

Up to 32 Aggregated Links may be defined, each with up to eight member ports, to form a single Link Aggregated Group (LAG). This enables:
Fault tolerance protection from physical link disruption
Higher bandwidth connections
Improved bandwidth granularity
High bandwidth server connectivity
A LAG is composed of ports with the same speed, set to full-duplex operation.
For more information, see "LAG Configuration" on page 410.

Link Aggregation and LACP

LACP uses peer exchanges across links to determine, on an ongoing basis, the aggregation capability of various links, and continuously provides the maximum level of aggregation capability achievable between a given pair of devices. LACP automatically determines, configures, binds, and monitors the port binding within the system.
For more information, see "Link Aggregation" on page 509.

BootP and DHCP Clients

DHCP enables additional setup parameters to be received from a network server upon system startup. DHCP service is an on-going process. DHCP is an extension of BootP.
For more information, see "DHCP IPv4 Interface" on page 214.

Quality of Service Features

Class of Service 802.1p Support

The IEEE 802.1p signaling technique is an OSI Layer 2 standard for marking and prioritizing network traffic at the data link/MAC sub-layer. 802.1p traffic is classified and sent to the destination. No bandwidth reservations or limits
DELL CONFIDENTIAL – PRELIMINARY 10/30/13 - FOR PROOF ONLY
24 Dell PowerConnect 55xx Systems User Guide
FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\Maintenance Projects\Dell
are established or enforced. 802.1p is a spin-off of the 802.1Q (VLANs) standard. 802.1p establishes eight levels of priority, similar to the IP Precedence IP Header bit-field.
Contax\sources\CxUGFeatures.fm

Advanced QoS

Frames that match an ACL and were permitted entrance are implicitly labeled with the name of the ACL that permitted their entrance. Advanced mode QoS actions defined in network policies can then be applied to these flows.
The switch can set DSCP values and map IPv6 DSCP to egress queues in the same way it does for IPv4. The switch detects IPv6 frames by the IPv6 ether­type.
For more information about Advanced QoS, see "QoS Advanced Mode" on page 679.

TCP Congestion Avoidance

The TCP Congestion Avoidance feature activates an algorithm that breaks up or prevents TCP global synchronization on a congested node, where the congestion is due to multiple sources sending packets with the same byte count.
For more information, see "The following is an example of the CLI commands:" on page 667.

Device Management Features

SNMP Alarms and Trap Logs

The system logs events with severity codes and timestamps. Events are sent as SNMP traps to a Trap Recipient List.
For more information, see "SNMP" on page 314
DELL CONFIDENTIAL – PRELIMINARY 10/30/13 - FOR PROOF ONLY
Dell PowerConnect 55xx Systems User Guide 25
.
FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\Maintenance Projects\Dell
Contax\sources\CxUGFeatures.fm

SNMP Versions 1, 2, and 3

Simple Network Management Protocol (SNMP) over the UDP/IP protocol controls access to the system. A list of community entries is defined, each consisting of a community string and its access privileges. There are three levels of SNMP security: read-only, read-write, and super. Only a super user can access the Community table.
For more information, see "SNMP" on page 314.

Web-Based Management

Web-based management enables managing the system from any web browser. The system contains an Embedded Web Server (EWS) that serves HTML pages, through which the system can be monitored and configured. The system internally converts web-based input into configuration commands, MIB variable settings, and other management-related settings.

Management IP Address Conflict Notification

This feature validates the uniqueness of the switch's IP address, whether it is assigned manually or through DHCP. If the IP address is not unique, the switch performs actions according to the address type. If the IP address is static, see more information about this in "IPv4 Interface Parameters" on page 210. If the IP address is dynamic, see more information about this in"DHCP IPv4 Interface" on page 214.

Flow Monitoring (sflow)

The switch supports statistics collection, using a sampling technology called sFlow that is based on RFC 3176. The sFlow sampling technology is embedded within the switch, and provides the ability to continuously monitor traffic flows on some or all the interfaces simultaneously.
For more information, see "sFlow" on page 375.

Configuration File Download and Upload

The device configuration is stored in a configuration file. The configuration file includes both system-wide and port-specific device configuration. The system can display configuration files as a collection of CLI commands that are stored and manipulated as text files.
DELL CONFIDENTIAL – PRELIMINARY 10/30/13 - FOR PROOF ONLY
26 Dell PowerConnect 55xx Systems User Guide
FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\Maintenance Projects\Dell
Contax\sources\CxUGFeatures.fm

Auto-Update of Configuration/Image File

This feature facilitates installation of new devices. When you enable the various auto-update options, the device automatically downloads a new image or configuration file when it receives its IP address from a TFTP server, and automatically reboots, using the image or configuration file it received.
For more information, see "Auto-Update/Configuration Feature" on page 338.

TFTP Trivial File Transfer Protocol

The device supports boot image, software, and configuration upload/download via TFTP.

USB File Transfer Protocol

The device supports boot image, software, and configuration upload/download via USB.

Remote Monitoring

Remote Monitoring (RMON) is an extension to SNMP that provides comprehensive network traffic monitoring capabilities. RMON is a standard MIB that defines MAC-layer statistics and control objects, enabling real-time information to be captured across the entire network.
For more information, see "Statistics/RMON" on page 607.

Command Line Interface

Command Line Interface (CLI) syntax and semantics conform as much as possible to common, industry standards. CLI is composed of mandatory and optional elements. The CLI interpreter provides command and keyword completion to assist users and save typing.

Syslog

Syslog is a protocol that enables event notifications to be sent to a set of remote servers, where they can be stored, examined, and acted upon. The system sends notifications of significant events in real time, and keeps a record of these events for after-the-fact usage.
For more information on Syslog, see "Logs" on page 195.
DELL CONFIDENTIAL – PRELIMINARY 10/30/13 - FOR PROOF ONLY
Dell PowerConnect 55xx Systems User Guide 27
FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\Maintenance Projects\Dell
Contax\sources\CxUGFeatures.fm

SNTP

The Simple Network Time Protocol (SNTP) assures accurate network Ethernet Switch clock time synchronization up to the millisecond. Time synchronization is performed by a network SNTP server. Time sources are prioritized by strata. Strata define the distance from the reference clock. The higher the stratum (where zero is the highest), the more accurate the clock.
For more information, see "Time Synchronization" on page 169.

Domain Name System

Domain Name System (DNS) converts user-defined domain names into IP addresses. Each time a domain name is assigned, the DNS service translates the name into a numeric IP address. For example, www.ipexample.com is translated into 192.87.56.2. DNS servers maintain domain name databases containing their corresponding IP addresses.
For more information, see "Domain Name System" on page 242.

802.1ab (LLDP-MED)

The Link Layer Discovery Protocol (LLDP) enables network managers to troubleshoot, and enhances network management by discovering and maintaining network topologies over multi-vendor environments. LLDP discovers network neighbors by standardizing methods for network devices to advertise themselves to other systems, and to store discovered information. The multiple advertisement sets are sent in the packet Typ e L en gt h Va lu e (TLV) field. LLDP devices must support chassis and port ID advertisement, as well as system name, system ID, system description, and system capability advertisements.
LLDP Media Endpoint Discovery
by enabling various IP systems to co-exist on a single network LLDP. It provides detailed network topology information, emergency call service via IP phone location information, and troubleshooting information.
For more information, see "LLDP" on page 541.
(LLDP-MED) increases network flexibility
DELL CONFIDENTIAL – PRELIMINARY 10/30/13 - FOR PROOF ONLY
28 Dell PowerConnect 55xx Systems User Guide
FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\Maintenance Projects\Dell
Contax\sources\CxUGFeatures.fm

Security Features

SSL
Secure Socket Layer (SSL) is an application-level protocol that enables secure transactions of data through privacy, authentication, and data integrity. It relies upon certificates and public and private keys.

Port-Based Authentication (Dot1x)

Port-based authentication enables authenticating system users on a per-port basis via an external server. Only authenticated and approved system users can transmit and receive data. Ports are authenticated via the Remote Authentication Dial-In User Service (RADIUS) server using the Extensible Authentication Protocol (EAP). Dynamic VLAN Assignment (DVA) enables network administrators to automatically assign users to VLANs during the RADIUS server authentication.
For more information, see "Dot1x Authentication" on page 132.

Locked Port Support

Locked Port increases network security by limiting access on a specific port to users with specific MAC addresses. These addresses are either manually defined or learned on that port. When a frame is seen on a locked port, and the frame source MAC address is not tied to that port, the protection mechanism is invoked.
For more information, see "Port Security" on page 98.

RADIUS Client

RADIUS is a client/server-based protocol. A RADIUS server maintains a user database that contains per-user authentication information, such as user name, password, and accounting information.

RADIUS Accounting

This feature enables recording device management sessions (Telnet, serial, and WEB but not SNMP) and/or 802.1x authentication sessions.
DELL CONFIDENTIAL – PRELIMINARY 10/30/13 - FOR PROOF ONLY
Dell PowerConnect 55xx Systems User Guide 29
FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\Maintenance Projects\Dell
Contax\sources\CxUGFeatures.fm
Due to the complexity of 802.1x setup and configuration, many mistakes can be made that might cause loss of connectivity or incorrect behavior. The
802.1x Monitor mode enables applying 802.1x functionality to the switch, with all necessary RADIUS and/or domain servers active, without actually taking any action that may cause unexpected behavior. In this way, the user can test the 802.1x setup before actually applying it.
For more information, see "RADIUS" on page 291.
SSH
Secure Shell (SSH) is a protocol that provides a secure, remote connection to a device. SSH version 2 is currently supported. The SSH server feature enables an SSH client to establish a secure, encrypted connection with a device. This connection provides functionality that is similar to an inbound telnet connection. SSH uses RSA and DSA Public Key cryptography for device connections and authentication.
For more information, see "Security Management and Password Configuration" on page 75.

TAC ACS+

TACACS+ provides centralized security for validation of users accessing the device. TACACS+ provides a centralized, user management system, while still retaining consistency with RADIUS and other authentication processes.
For more information, see "TACACS+" on page 282.

Password Management

Password management provides increased network security and improved password control. Passwords for SSH, Telnet, HTTP, HTTPS, and SNMP access are assigned security features.
For more information, see "Password Management" on page 286.
The switch provides the ability to demand strong passwords, meaning that they must contain both upper and lower-case letters, numbers, and punctuation marks.
For more information, see "Password Management" on page 286.
DELL CONFIDENTIAL – PRELIMINARY 10/30/13 - FOR PROOF ONLY
30 Dell PowerConnect 55xx Systems User Guide
Loading...
+ 709 hidden pages