Datasheet XWT4805-15, XWT4805-12, XWT2405-15, XWT2405-12, XWT1205-12 Datasheet (Power-One)

...
Page 1
(888) IPD-CONVerters
(888) 473-2668 www.ipdconverters.com
XWT SERIES - TRIPLE, 150 WATT
Rev. 11/2000
DESCRIPTION
XWT DC/DC converters are high power, triple output converters that cover a wide range of applications. The XWT features remote sense leads for accurate point of load regulation, and has short circuit and overcurrent protection. For single and dual output high power solutions, see the XWS and XWD series.
TECHNICAL SPECIFICA TIONS
Input
Voltage Range 12 VDC Nominal 10 - 20 VDC 24 VDC Nominal 18 - 36 VDC 48 VDC Nominal 36 - 72 VDC
Input Ripple Current 20% Iin Max. Reverse Input Current 100% Iin Max.
Output
Setpoint Accuracy ±1% All Outputs Line Regulation Vin Min. - Vin Max., I Load Regulation I Minimum Output Current 10 % All Outputs
Min.- I
out
out
Dynamic Regulation, Loadstep 25% I
Pk Deviation 4% V Settling Time 500 µs
Voltage Trim Range ±10% Current Limit Threshold Range, % of I
Turn-On Time 10 ms Remote Shutdown TTL and CMOS Compatible, Positive Logic Switching Frequency 200 kHz Isolation
Input - Output 500 VDC Temperature Coefficient ±0.02%/°C
Case Temperature
Operating Range -25 to +85°C
Storage Range -40 to +125°C Thermal Shutdown Range 105 to 115°C Humidity Max., Non-Condensing 95% Vibration, 3 Axes, 5 Min Each 5 g, 10 - 55 Hz MTBF† (Bellcore TR-NWT-000332) Consult Factory Safety Consult Factory Weight (approx.) 15.4 oz
Rated ±1% V
out
Max., Vin Nom. ±1% V
Rated 110% - 130%
out
General
All Outputs
out
All Outputs
out
FEA TURES
• High Power Package
• Wide Input Range
• 12, 24, and 48V Input Versions
85
80
75
70
EFFICIENCY %
65
60
10 20 30 40 50 60 70 80 90 100
90
85
80
75
EFFICIENCY %
out out
††
70
65
10 20 30 40 50 60 70 80 90 100
MTBF predictions may vary slightly from model to model.
Specifications typically at 25°C, normal line, and full load, unless otherwise stated.
Soldering Conditions: I/O pins, 260°C, ten seconds; fully compatible with commercial wave-soldering equipment.
Safety: Agency approvals may vary from model to model. Please consult factory for specific model information.
• Trim and Enable Pin
• Remote Sense Pins
• 500V Isolation
Efficiency vs. Load (24V Input)
XWT2405-12
EFF. (18v) EFF. (24v) EFF. (36v)
Efficiency vs. Load (48V Input)
XWT4805-12 XWT4805-15
LOAD %
Notes
1
Page 2
XWT SERIES - TRIPLE, 150 WATT
MODELS - (See the last page of this file for options.)
Vin
(Volts)
12 12 24 24 48 48
Vin Range
(Volts)
10 - 20 10 - 20 18 - 36 18 - 36 36 - 72 36 - 72
Iin Max.*
(Amps)
25.0
25.0
13.2
13.2
6.8
8.8
* Maxi mum i np ut c urre nt at mi ni mum i np ut v o l tag e , maxi mum rate d outp ut p ower. ** A t nomi nal V in, rated o u tp u t.
MECHANICAL DRAWING
5.50"
(139.7mm)
#4-40 THREADED INSERTS 4PLS.
1
2
3
3.50"
(88.9mm)
-0.60"
(-15.2mm)
4
5
6
7
0
BOTTOM VIEW
Vout
(Volts)
5, ±12 5, ±15 5, ±12 5, ±15 5, ±12 5, ±15
Iout Rated
(Amps)
12, ±3. 0 12, ±2. 5 15, ±4. 0 15, ±3. 3 15, ±4. 0 15, ±3. 3
8
9
10
11
12
13
14
4.300"
(109.2mm)
Ripple & No ise
Pk-Pk (mV)
50/120/120 50/150/150 50/120/120 50/150/150 50/120/120 50/150/150
2.625"(66.7mm)
2.250"(57.2mm)
1.875"(47.6mm)
1.500"(38.1mm)
1.125"(28.6mm)
0.750"(19.1mm)
0.375"(9.5mm)
0
-0.375"(-9.5mm)
-0.625"(-15.9mm)
Efficiency
Typ. **
79% 81% 83% 83% 84% 85%
Model
XWT1205-12 XWT1205-15 XWT2405-12 XWT2405-15 XWT4805-12 XWT4805-15
Thermal Impedance
Natural Convection 2.5 °C/W 100 LFM 2.1 °C/W 200 LFM 1.7 °C/W 300 LFM 1.3 °C/W 400 LFM 1.1 °C/W
Note: Thermal impedance data is dependent on many environmental factors. The exact thermal performance should be validated for specific application.
Pin Function
1 No Pin 2-V 3-V 4+V 5+V 6 Enable
in in
in in
7 Case 8 - Sense 1
9-V 10 +V
11 + Sense1 12 - V 13 Common 2 & 3 14 + V
out1
out1
out2
out3
DIA 0.040" 13PL.
(1.0mm)
Tolerances
Inches: (Millimeters) .XX ± 0.040 .X ± 1.0 .XXX ± 0.010 .XX ± 0.25
0.92"
(23.4mm)
Pin: ± 0.002 ± 0.05
(Dimensions as listed unless otherwise specified.)
2
Page 3
MECHANICAL DRAWING
(888) IPD-CONVerters
(888) 473-2668 www.ipdconverters.com
XWT SERIES - TRIPLE, 150 WATT
TERMINAL STRIP OPTION
#4-40 THREADED INSERTS 4PLS.
2
3
4
5
6
7
4.300"
(109.22mm)
5.50"
(139.7mm)
PIN VIEW
DIA 0.041" 13PLS.
(1.04mm)
81
9
10
11
12
13
14
0.375" EA. (9.53mm)
3.50"
(88.90mm)
3.000"
(76.20mm)
UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES TOLERANCES:
.X }.030 .XX }.040 .XXX }.010
FRACTION }.030
0.52"
(13.2mm)
0.92"
(23.4mm)
DIA 0.18"
(4.6mm)
0.25"
(6.4mm)
3
Page 4
OPTIONS
When ordering equipment options, use the following suffix information. Select the option(s) that you prefer and add them to the model number. Example ordering options are located below the options table.
OPTION SUFFIX APPLICABLE SERIES REMARKS
Negative Logic N HAS, HBD, HBS, HES, LES, QBS,
Lucent Compatible Trim T HAS, HBD, HBS, HES, QBS, QES Terminal Strip TS XWS, XWD, XWT Trim 1 IAS, LES Enable 2 I A D, IAS, LES, SMS Trim and Enable 3 I AS, LES Current Share 4 S MS Headerless Y Encapsulated EWS, IWS, OWS
PIN LENGTH AND HEATSINK OPTIONS
0.110” (2.8mm) Pin Length 8 All Units (Except SMS)
0.150” (3.8mm) Pin Length 9 All Units (Except SMS)
0.24” (6.1mm) Horizontal Heatsink 1H All Units (Except DIP, SIP, and SM
0.24” (6.1mm) Vertical Heatsink 1V All Units (Except DIP, SIP, and SM
0.45” (11.4mm) Horizontal Heatsink
0.45” (11.4mm) Vertical Heatsink 2V All Units (Except DIP, SIP, and SM
0.95” (24.1mm) Horizontal Heatsink
0.95” (24.1mm) Vertical Heatsink 3V All Units (Except DIP, SIP, and SM
2H All Units (Except DIP, SIP, and SM
3H All Units (Except DIP, SIP, and SM
QES, TES, TQD
Packages)
Packages)
Packages)
Packages)
Packages)
Packages)
TTL “Low” Turns Module ON TTL “High” Turns Module OFF
Standard Pin Length is 0.180” (4.6mm)
Includes Thermal Pad
Includes Thermal Pad
Includes Thermal Pad
Includes Thermal Pad
Includes Thermal Pad
Includes Thermal Pad
Example Options:HBS050ZG-ANT3V = HBS050ZG-A with negative logic, Lucent compatible trim, and
0.95” vertical heatsink. LES015YJ-3N = LES015YJ with optional trim and enable, negative logic. QBS066ZG-AT8 = QBS066ZG-A with Lucent compatible trim and 0.110” pin length.
NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc.
TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
4
Loading...