Danby DPAC10010, DPAC9010 User Manual

Owner’s Use and Care Guide
Guide d’utilisation et soins de Propriètaire
Model • Modèle
DPAC9010, DPAC10010
Danby Products Ltd, Guelph, Ontario Canada N1H 6Z9
Danby Products Inc, Findlay, Ohio USA 45840
V1.12.09 JF
If the unit changes ownership, be sure the manual accompanies this unit.
CONSERVER CES INSTRUCTIONS POUR CONSULTATION ULTÉRIEUR:
En cas de revente l’appareil, ce manuel doit être inclus avec l’appareil.
CAUTION:
Read and follow all
safety rules and
operating instructions
before first use of this product.
MISE EN GARDE :
Veuillez lire
attentivement les
consignes de sécurité et
les directives
d'utilisation avant
l'utilisation initiale de
ce produit.
PORTABLE AIR CONDITIONER
Owner’s Use and Care Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 10
• Welcome
• Important Safety Information
• Features
• Installation
• Operation
• Care and Maintenance
• Troubleshooting
CLIMATISEUR PORTATIF
Guide d’utilisation et soins de Propriètaire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 - 20
• Bienvenue
• Consignes de Sécurité Importante
• Caractéristiques
• Installation
• Fonctionnement
• Soins et Entretien
• Dépannage
Thank you for choosing a Danby appliance to provide you and your family with all of the “Home Comfort” requirements of your home, cottage, or office. This Owner’s Use and Care Guide will provide you with valuable information necessary for the proper care and maintenance of your new appliance. If properly maintained, your Danby appliance will give you many years of trouble free operation. Please take a few moments to read the instructions thoroughly and familiarize yourself with all of the operational aspects of this appliance.
Your Danby Portable Air-Conditioner is a multi-functional room air-exchanging, air-processing appliance, designed to offer you the functions of; Air Conditioning, Dehumidifying, and Independent Fan. Each individual mode is featured with “oscillating” air swing capabilities. This unit can be conveniently moved from room to room within your home and set up in just minutes. Imagine the convenience of 4 Season Home Comfort at your fingertips, anywhere, anytime.
For easy reference, may we suggest you attach a copy of your sales slip/receipt to this page, along with the following information, located on the manufacturers nameplate on the rear panel of the unit.
Model Number:
Serial Number:
Date of Purchase:
This information will be necessary if your unit requires servicing and/or for general inquiries. To contact a
Customer Service Representative, call Danby TOLL FREE: 1-800-26- (1-800-263-2629)
WELCOME
1
READ ALL SAFETY INFORMATION BEFORE USING
1) Check available power supply and resolve any wiring problems
BEFORE installation and operation of this unit. All wiring must comply with local and national electrical codes and be installed by a qualified electrician. If you have any questions regarding the following instructions, contact a qualified electrician.
2) This appliance draws 7.8 nameplate amps under Cooling Mode
and may be used in any properly wired, general purpose 15 amp household grounded receptacle.
3) For your safety and protection, this unit is grounded through the
power cord plug when plugged into a matching wall outlet. If you are not sure whether the wall outlets in your home are properly grounded, please consult a qualified electrician.
WARNING: Improper connection of the grounding plug can
result in risk of Fire, Electric Shock, and/or injury to Persons associated with the appliance. Check with a qualified service representative if in doubt that the appliance is proplery grounded.
4) DO NOT USE PLUG ADAPTERS OR EXTENSION CORDS
WITH THIS UNIT. If it is necessary to use an extension cord with this unit, use an approved “air conditioner” extension cord only (available at most local hardware stores).
5) To avoid the possibility of personal injury, always disconnect the
power supply to the unit before installing and/or servicing.
TABLE 1
Suggested Individual Branch Circuit
Nameplate Amps *AWG Wire Size
9.5 16 AWG- American Wire Gauge
*Based on copper wire at 60°C temperature rating.
TABLE 2
Receptacle and Fuse Types Rated Volts 125 Amps 13 Wall Outlet
Fuse Size 15 Time Delay Fuse Plug Type
(or Circuit Breaker)
IMPORTANT SAFETY INFORMATION
ELECTRICAL
SPECIFICATIONS
CAUTION: Do not leave this unit
unattended in a space where people or animals cannot react to a failed unit are located. A failed unit can cause extreme overheating or death in such an enclosed, unattended space.
2
The power cord supplied with this air conditioner contains a device that senses damage to the power cord. To test if your power cord is working properly, you must do the following:
1) Connect the power supply cord to an electrical
outlet.
2) The power supply cord has two buttons located on
the head of the plug. One button is marked “TEST”, and the other is marked “RESET”. Press the “TEST” button; you will hear a click as the “RESET” button pops out.
3) Press the “RESET” button; you will hear a click
as the button engages.
4) The power supply cord is now energized and
supplying electricity to the air conditioner (on some products this is also indicated by a light on the plug head).
NOTE: The power cord supplied with this air conditioner contains a current leakage detection device designed to reduce the risk of fire. In the event the power supply cord is damaged, it cannot be repaired and must be replaced with a new cord from the product manufacturer.
• Under no circumstances should this device be used to turn the unit on or off.
• The “RESET” button must always be pushed in (engaged) for correct operation.
• The power supply cord must be replaced if it fails to reset when the “TEST” button is pushed in.
POWER
SUPPLY CORD
Your Danby appliance is designed to be highly efficient in energy savings. Follow these
recommendations for greater efficiency.
1) Select a thermostat setting that suits your comfort
needs and leave at that chosen setting.
2) The air filter is very efficient in removing
airborne particles. Keep the air filter clean at all times.
3) Use drapes, curtains or shades to keep direct
sunlight from penetrating and heating room, but do not allow drapes or curtains to obstruct the air flow around the unit.
4) Start your air conditioner before the outdoor air
becomes hot and uncomfortable, to avoid an initial period of discomfort while the unit is cooling off the room. Use of the automatic start/stop programmable TIMER feature can be a major asset in this regard if utilized to the fullest extent.
5) When outdoor temperatures are cool enough, turn
the air conditioner off and use the FAN MODE. This circulates indoor air, providing some cooling comfort while utilizing less electricity.
IMPORTANT SAFETY INFORMATION (cont’d)
ENERGY-SAVING
TIPS
3
Air Exhaust
LCD Display
Front Panel
Handles
Wheels
Air Filter
Air inlet
Air outlet
Cover
Electricity cable
Water drain
Air inlet
FEATURES
Air Conditioning Mode ONLY: Your window kit
has been designed to fit most standard “vertical”/ ”horizontal” windows up to a maximum height of 80” (203cm). For vertical window applications, multi lock positions are provided on the edge of each slider section to secure each sliding section together.
1) Select a suitable location, making sure you have
access to an electrical outlet.
2) Install the flexible hose to the rear side of the unit.
Insert the hose collar on top of the exhaust opening and twist to lock into position.
3) Install the adjustable Sliding Window Kit as
required (see Fig. 4a & 4b).
4) Install the opposite end of the flexible exhaust
hose into the window exhaust adapter.
5) Install the window exhaust adapter into the
opening in the slider section, making sure the window slider sections are secure.
6) Plug the unit into a 115V/60Hz grounded electrical
outlet.
Sliding Window Kit: Min.: 28
1
/3” (67.5cm)
Max.: 80” (203cm)
Sliding Window Kit: Min.: 28 1/3 (72cm) Max.: 80” (203cm)
Horizontal Window
Vertical Window
WINDOW KIT
INSTALLATION
Back of window panel
Tube Adapters
Fig. 2
Instructions for Assembling the Sliding Window Kit- Fig. 2
1) Insert tube adapters through the back of the window panel.
2) Secure each tube adapter with four screws through the front of the
window panel.
3) Insert window panel extensions into window panel. Lightly tighten the
screws in the window panel to hold the extensions in place.
Fig 3a
Fig 3b
4
INSTALLATION
Fig. 1
INSTALLATION ACCESSORIES
Flexible Exhaust Hose Exhaust Nozzle Connector
Fixture
Sliding Window Kit: 28 1/3” (72cm)- 80” (203cm)
Screws
Water hose (79”/ 200cm)
ELECTRIC SHOCK HAZARD: To avoid the possibility of
personal injury, disconnect power to the unit before installing or servicing. Caution: To avoid installation/operation difficulties, read these instructions thoroughly.
Flexible Exhaust Hose (13cm) & Exhaust nozzle connector (2 pcs)... from 17
7
/10 (45cm) to 53 1/6” (135cm)
Flexible Exhaust Hose (11cm) & Exhaust nozzle connector (2pcs)...from 15
3
/4” (40cm) to 51 1/5” (130cm)
Adjustable sliding window/door kit (3 pcs)... from 28
1
/3”(72cm) to
80” (203cm)
Fixture..... (2 pcs) & Screws..... (8 pcs)
NOTE: The exhaust/window kit must be installed at all times when
the unit is operating under AIR CONDITIONING mode. There should be at least 11.8” (30cm) clearance between the unit and any other objects or building structures, and should be installed on a level surface.
Warning Light
Receiving Sensor
KEY PAD FUNCTIONS
POWER SWITCH: Turns unit ON/OFF MODE: Allows you to scroll through and
select desired operating mode.
FAN: Select from three different fan settings;
High, Medium, and Low.
AUTO-TIMER
AUTO-TIMER Adjust: AUTO TURN OFF- With machine in running mode,
press timer button to set timer control. Press
buttons to select number of hours you would
like the unit to run before it automatically shuts off.
AUTO TURN ON- With machine in stand by mode, press timer button to set timer control. Press
buttons to select number of hours before the unit
automatically starts running in air conditioning mode.
NOTE: The time is adjustable between 1-24 hours.
TEMPERATURE Adjust:
• Used for adjusting the thermostat.
• The default display is room temperature.
• In cooling mode, when button is pressed, the set temperature is displayed and may be adjusted. After 15 seconds the display will revert back to room temperature. Temperature is only adjustable in cool mode.
Warning Light
Condensed water may accumulate in the unit. If the internal tank becomes full, the Warning signal in the LCD Display will light up and the unit will not operate until it has been drained.
NOTE: By pressing both buttons at the same time for more than 3 seconds, the display will toggle between Celsius and Fahrenheit.
LCD Display
Cooling Mode
Dehumidify Mode Fan Only Mode High Fan Speed
Medium Fan Speed
Low Fan Speed
Display Set Temperature
Display Timer Setting of Auto Switch ON /
OFF
Warning Light (the machine will stop
running)
OPERATION
5
Loading...
+ 14 hidden pages