To adjust the air ow .................................................................................................. 13
To adjust the air ow rate To adjust the air ow direction
Useful Functions
To operate wisely using the sensor ........................................................................... 16
3 Area INTELLIGENT EYE AUTO OFF
To use the timer ........................................................................................................ 17
ON/OFF TIMER COUNTDOWN OFF TIMER
To ensure a comfortable sleep .................................................................................. 19
COMFORT SLEEP TIMER
To guarantee high heating capacity when you wake up ............................................ 21
QUICK HEATING TIMER
To increase the cooling or heating power .................................................................. 23
POWERFUL
Tips for saving energy
A. Cover windows with a blind or a curtain.
Blocking sunlight and air from outdoors increases
the cooling/heating effect.
B. Be careful not to cool the room too much.
Keeping the temperature setting at a moderate level
helps save energy.
Recommended temperature setting
• For cooling: 26-28°C
• For heating: 20-24°C
C. Keep air lter clean.
Clogged air lters cause inef cient operation and waste energy.
When the AUTO CLEANING FILTER operation is enabled, the
air conditioner cleans the lter periodically. Ef cient operation is
available at any time without concerns about dirt.
Page 28
A
C
B
English
Before Operation
To purify the air in the room ...................................................................................... 24
FLASH STREAMER AIR PURIFYING FRESH AIR SUPPLY VENTILATION
To consider the environment of use .......................................................................... 25
ECONO OUTDOOR UNIT QUIET
To keep the air conditioner clean .............................................................................. 27
MOLD PROOF CLEANING FILTER
To know the status of your room and air conditioner ................................................. 30
INFORMATION
To change the default settings .................................................................................. 31
Menu settings
Cleaning
Cleaning (for service personnel) ............................................................................... 35
< When the TIMER lamp (orange) blinks > .................................................................................... 36
< When the MOLD PROOF / CLEANING FILTER lamp (green) blinks > ......................................37
When the Need Arises
When the OPERATION lamp (green) blinks ............................................................. 40
Troubleshooting (for service personnel) .................................................................... 42
Basic Operation
Useful Functions
Cleaning
When the Need
Arises
The English text is the original instruction.
Other languages are translations of the original instructions.
Tips for your comfort
INTELLIGENT EYE sensor
When the INTELLIGENT EYE sensor is used, the sensor detects the movement
of a person and adjusts the airow direction and operation.
Do you want to direct the airow away from you?
Do you want to save power consumption in a room with no person in it?
The sensor will cooperate with you.
FLASH STREAMER
Flash streamer decomposes mold and allergic substances.
It keeps air in the room and the inside of the air conditioner clean to make a
comfortable space.
Page 24
Page 15, 16
Safety precautions
Read the precautions in this manual carefully
before operating the unit.
• Keep this manual where the user can easily nd it.
• The precautions described herein are classied as WARNING and CAUTION. They both contain important information regarding safety.
Be sure to observe all precautions without fail.
WARNING .....................
CAUTION ......................
Never attempt.Be sure to follow the instructions.
• After reading, keep this manual in a convenient place so that you can refer to it whenever necessary. If the equipment is transferred to a
new user, be sure also to hand over the manual.
Failure to follow these instructions properly may result in personal injury or loss of life.
Failure to observe these instructions properly may result in property damage or
personal injury, which may be serious depending on the circumstances.
This appliance is lled with R32.
Be sure to establish an earth
connection.
WARNING
• Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
• The appliance must be stored in a room without continuously operating ignition sources (for example: open ames, an
operating gas appliance or an operating electric heater).
• Do not pierce or burn.
• Be aware that refrigerants may not contain an odour.
• The appliance must be installed, operated and stored in a room with a oor area larger than 1.8m
• In order to avoid re, explosion or injury, do not operate the unit when harmful, among which ammable or corrosive gases, are
detected near the unit.
• Be aware that prolonged, direct exposure to cool or warm air from the air conditioner, or to air that is too cool or too warm can
be harmful to your physical condition and health.
• Do not place objects, including rods, your ngers, etc., in the air inlet or outlet. Product malfunctioning, product or injury
damage may result due to contact with the air conditioner’s high-speed fan blades.
• Do not attempt to repair, dismantle, reinstall or modify the air conditioner yourself as this may result in water leakage, electric
shocks or re hazards.
• Do not use ammable spray near the air conditioner, or otherwise re may result.
• Do not use a refrigerant other than the one indicated on the outdoor unit (R32) when installing, moving or repairing. Using
other refrigerants may cause trouble or damage to the unit, and personal injury.
• To avoid electric shocks, do not operate with wet hands.
2
.
• Beware of re in case of refrigerant leakage. If the air conditioner is not operating correctly, i.e. not generating cool or warm air,
refrigerant leakage could be the cause. Consult your dealer for assistance. The refrigerant within the air conditioner is safe and
normally does not leak.
However, in the event of a leakage, contact with a naked burner, heater or cooker may result in generation of noxious gas. Do
not use the air conditioner until a qualied service person conrms that the leakage has been repaired.
• Do not attempt to install or repair the air conditioner yourself. Improper workmanship may result in water leakage, electric
shocks or re hazards. Please contact your local dealer or qualied personnel for installation and maintenance work.
• When the air conditioner is malfunctioning (giving off a burning odour, etc.) turn off power to the unit and contact your local
dealer. Continued operation under such circumstances may result in a failure, electric shocks or re hazards.
• Be sure to install an earth leakage circuit breaker. Failure to install the earth leakage circuit breaker may result in electric
shocks or re.
• Be sure to earth the unit. Do not earth the unit to a utility pipe, lightning conductor or telephone earth lead. Imperfect earthing
may result in electric shocks.
CAUTION
• Do not use the air conditioner for purposes other than those for which it is intended. Do not use the air conditioner for cooling
precision instruments, food, plants, animals or works of art as this may adversely affect the performance, quality and/or
longevity of the object concerned.
• Do not expose plants or animals directly to airow from the unit as this may cause adverse effects.
3
• Do not place appliances that produce naked ames in places exposed to the airow from the unit as this may impair
combustion of the burner.
• Do not block air inlets nor outlets. Impaired airow may result in insufcient performance or trouble.
• Do not sit on the outdoor unit, put things on the unit, or pull the unit. Doing so may cause accidents, such as falling or toppling
down, thus resulting in injury, product malfunctioning, or product damage.
• Do not place objects that are susceptible to moisture directly beneath the indoor or outdoor units. Under certain conditions,
condensation on the main unit or refrigerant pipes, air lter dirt or drain blockage may cause dripping, resulting in fouling or
failure of the object concerned.
• After prolonged use, check the unit stand and its mounts for damage. If they are left in a damaged condition, the unit may fall
and cause injury.
• To avoid injury, do not touch the air inlet or aluminium ns of the indoor or outdoor units.
• The appliance is not intended for use by unattended young children or inrm persons. Impairment of bodily functions and harm
to health may result.
• Children should be supervised to ensure that they do not play with the unit or its remote controller. Accidental operation by a
child may result in impairment of bodily functions and harm health.
• Avoid impacts to the indoor and outdoor units, or otherwise product damage may result.
• Do not place ammable items, such as spray cans, within 1m of the air outlet.
The spray cans may explode as a result of hot air from the indoor or outdoor units.
• Be careful not to let pets urinate on the air conditioner. Urination on the air conditioner may result in electric shocks or re.
• Do not wash the air conditioner with water, as this may result in electric shocks or re.
• Do not place water containers (vases etc.) above the unit, as this may result in electric shocks or re hazards.
• To avoid oxygen depletion, ensure that the room is adequately ventilated if equipment such as a burner is used together with
the air conditioner.
• Before cleaning, be sure to stop unit operation, turn off the circuit breaker or remove the power cord. Otherwise, an electric
shock and injury may result.
• Only connect the air conditioner to the specied power supply circuit. Power supplies other than the one specied may result in
electric shocks, overheating and res.
• Arrange the drain hose to ensure smooth drainage. Imperfect drainage may cause wetting of the building, furniture etc.
• Do not place objects in direct proximity of the outdoor unit and do not let leaves and other debris accumulate around the unit.
Leaves are a hotbed for small animals which can enter the unit. Once in the unit, such animals can cause malfunctions, smoke
or re when making contact with electrical parts.
• Do not place objects around the indoor unit.
Doing so may have an adverse inuence on the performance, product quality, and life of the air conditioner.
• This appliance is not intended to be used by persons with reduced physical, sensory or mental capabilities, or with lack of
operation knowledge, unless they have been given supervision or instruction concerning the appliance use by person
responsible for their safety.
Keep out of children’s reach to ensure that they do not play with the appliance.
• For care and cleaning, call service personnel.
P002
Before Operation
This is an appliance that is not accessible to the general public.
Installation site
< To install the air conditioner in the following types of environments, consult the dealer >
• Places with an oily environment or where steam or soot occurs.
• Salty environment such as coastal areas.
• Places where sulde gas occurs such as hot springs.
• Places where snow may block the outdoor unit.
• The indoor unit is at least 1m away from any television or radio set (unit may cause interference with the picture or sound).
• The drain from the outdoor unit must be discharged to a place of good drainage.
Consider nuisance to your neighbours from noises
< For installation, choose a place as described below >
• A place solid enough to bear the weight of the unit which does not amplify the operating sound or vibration.
• A place from where the air discharged from the outdoor unit or the operating sound will not annoy your neighbours.
Electrical work
• For power supply, be sure to use a separate power circuit dedicated to the air conditioner.
System relocation
• Relocating the air conditioner requires specialized knowledge and skills. Please consult the dealer if relocation is necessary for
moving or remodeling.
4
Names and functions of parts
Indoor unit
(top surface)
Front panel
Auxiliary ap
(horizontal blade)
Page 13
Flap (horizontal blade)
Page 13
Air outlet
Display
MOLD PROOF /
CLEANING FILTER lamp (green)
QUICK HEATING TIMER lamp (red)
Shutter
(bottom
air inlet)
INTELLIGENT EYE sensorAir inlet
Louvres (vertical blades)
(Inside of the air outlet located on the
right and left sides.)
Page 13
Model name plate
Transmitter/Receiver
• Sends/receives signals to/from the remote
controller.
• The OPERATION lamp blinks with beep
sound to indicate signal reception.
OPERATION lamp (green)
TIMER lamp (orange)
< List of lamps >
LampColourStateDescription
TIMER lamporange
OPERATION lampgreen
QUICK HEATING TIMER
lamp
MOLD PROOF /
CLEANING FILTER lamp
dark red
bright red
green
Lights up
Blinks
Lights upThe air conditioner is running.
Blinks
Lights up
Lights up
Blinks
TIMER is set.
It is time to clean the streamer unit.
Check the error code.
QUICK HEATING TIMER is set.
Preparatory heating operation or QUICK HEATING TIMER operation is
running.
The air conditioner is running with the AUTO MOLD PROOF set to “On”.
MOLD PROOF operation or CLEANING FILTER operation is running.
It is time to clean the dust box.
Page 21
Page 17
Page 40
CaseSound type
Operation startbeep-beep
Setting changebeep
Operation stoplong beep
Page 36
Page 21
Page 37
Page 27
Page 27, 28
5
When the front panel is open
Page 35
Display unit
INTELLIGENT EYE sensor
Detects human motion to
con rm that a person is in
the area.
Air supply lter (black)
Removes dust taken in from
the outdoor air.
Humidifying temperature
and humidity sensor
(inside the unit)
Detects the temperature and
humidity of the humidi ed air to
control the degree of humidity.
Dust box
Scrapes dust off the air lter with the dust
brush and collects it.
Air lter (white)
(2 locations at right and left)
Page 39
Page 37
Page 38
Indoor unit ON/OFF switch
• Press to start the operation with the mode set to
“AUTO” and air ow rate to “AUTO”.
Press the button again to stop the operation.
• Use this button when no remote controller is
immediately available.
Streamer unit
Prevents mold and allergens
with the decomposition power
of the streamer discharge.
Page 36
Photocatalytic airpurifying and
deodorising lter
(black)
Adsorbs mold, allergens and
odour.
Page 39
Indoor temperature
and humidity sensor
(inside the unit)
Detects the temperature and
humidity in the room.
Before Operation
Outdoor unit
Humidifying unit air inlet
(front and back)
Humidifying unit air
outlet (front)
Humidifying unit
Air inlet
(side and back)
Air outlet
Drain outlet
(rear side of the bottom)
Drains water out from the outdoor unit during HEATING or
HUMID HEATING operation.
Outdoor temperature sensor
(back)
Detects the outdoor temperature.
Refrigerant pipes, inter-unit
wire and humidifying hose
Earth terminal
(inside)
Drain hose
Drains water from the indoor unit
during COOLING, “SARARA” DRY or
DRY COOLING operation.
Model name plate
6
Names and functions of parts
Remote controller
Display (LCD), with backlight
• Displays the operating conditions.
(All displayed here for your reference.)
• Press any of the operation buttons tolight
the backlight for about 5 seconds.
• Before use, peel off the protection sheet.
AUTO button
Automatically selects an appropriate operation
mode (COOLING or HEATING) based on the
indoor temperature and starts the operation.
Page 11
OFF button
Page 11
Stops the operation.
Transmitter/Receiver
Transmitter/Receiver
• Sends/receives signals to/from the indoor
unit.
• The remote controller must be used with the
transmitter/receiver pointed towards the
transmitter/receiver of the indoor unit.
Transmission will fail if there is an
obstruction such as a curtain between the
remote controller and indoor unit.
• The maximum distance for communication is
about 7m.
TEMPERATURE button
Page 12
Adjusts the temperature setting.
FLASH STREAMER AIR PURIFYING /
FRESH AIR SUPPLY VENTILATION
button
• Performs streamer discharge.
Page 24
• Fresh air is taken in from outside.
Cover
After you open the cover, close it
completely. The buttons on the
cover will not function properly if
the cover is not securely closed.
Cover
Model ARC477A1
Direct operation buttons
Starts the COOLING, “SARARA” DRY,
HEATING or “URURU” HUMIDIFY operation.
Page 11
HUMIDITY button
Page 12
Adjusts the humidity setting.
FAN button
Page 13
Adjusts the air ow rate setting.
OFF TIMER button
Sets the time until the operation stops.
Page 18
Notes on remote controller
• Take care to avoid dropping the remote controller or getting it wet. (Dropping or getting it wet may break it.)
• When the remote controller gets dirty, wipe it with a dry soft cloth.
• Signal communication may become poor if an electronic-starter-type uorescent lamp (such as inverter-type lamps) or TV is in the room.
Consult the service shop if that is the case.
• The sensitivity may become poor if the transmitter/receiver is exposed to direct sunlight.
7
Air ow direction buttons
1/12
Adjust the vertical and horizontal
air ow directions.
Page 13
SENSOR button
: Detects a person and
adjusts the air ow
direction.
: Automatically switches the
unit off when nopresence
is detected.
Page 16
FAN ONLY button
Performs FAN ONLY operation.
Page 11
Open the cover
1/12
A menu item is shown above.
A menu item is shown below.
FLASH STREAMER AIR PURIFYING
FRESH AIR SUPPLY VENTILATION
AUTO MOLD PROOF
AUTO CLEANING FILTER
3 Area INTELLIGENT EYE
AUTO OFF
POWERFUL
ECONO
OUTDOOR UNIT QUIET
The number of menu items.
1/12
ECONO/QUIET button
: Limits the maximum power consumption.
: Reduces the noise from the outdoor unit.
Page 24
Page 24
Page 27
Page 28
Page 16
Page 16
Page 23
Page 25
Page 25
Page 31
Before Operation
Page 25
POWERFUL button
Increases the air ow rate in the
COOLING or HEATING
operation.
Page 23
RESET button
Resets the dust box cleaning indicator and
streamer unit cleaning indicator.
Page 36, 37
INFORMATION button
Provides information such as
temperature and power
consumption.
Page 30
TIMER button
Sets the TIMERS.
Page 17, 19, 21
PREVIOUS button
Goes back to the previous
display.
MOLD PROOF button
Reduces mold and odour inside the unit.
CLEANING FILTER button
Removes dirt such as dust attached to the air lter.
CLOCK button
Sets the time of the clock.
SET UP button
Shows the SET UP display.
Page 31
SELECT button
Selects items.
Page 27
Page 10
BRIGHTNESS button
Sets the brightness of the
indoor unit lamps.
Page 10
APPLY button
Completes the remote
controller operation.
CANCEL button
Exits the SET UP display.
Cancels the timer settings.
Page 28
8
Preparation before operation
To set the batteries
1. Pull down the upper tab to open the
1
1
2. Insert 2 dry batteries AA.LR6 (alkaline).
Upper tab
33
cover.
• Using batteries other than AA.LR6 (alkaline) may lead to
improper operation.
Do not confuse
and sides.
the
Hole
Screws
2
2
Remote controller
holder
Lower tab
(2 locations)
Projection
3. Insert the 2 lower tabs on the cover to put
the cover back in place.
To x the remote controller holder to a wall
1. Choose a place where the signals can
reach the unit.
2. Fix the remote controller holder to a wall,
a pillar, or similar location with the screws
procured locally.
3. Fit the projection of the remote controller
holder into the hole at the back of the
remote controller.
Turn on the circuit breaker
• After the power is turned on, the aps of the indoor unit open and
close once to set the reference position.
Notes on batteries
• The batteries will last for about 1 year. If the remote controller display begins to fade and the reception degrades within
1 year, however, replace both batteries with new AA.LR6 (alkaline) ones at the same time.
• The batteries that come with the remote controller are for initial operation. The batteries may run out in less than 1 year.
• When the TIMERS are set, the settings are cancelled after replacing the batteries. Set the TIMERS again.
• When the air conditioner is not used for a long time, take the batteries out.
9
To set the clock
1. Press .
2. Press to set the clock to the current
time.
• Each time you press , the time changes by 1 minute. If
you press and hold the button, the time changes by
10 minutes.
3. Press .
• After “ CLOCK Set ” appears, the normal screen is
displayed again.
Before Operation
< To set the clock after replacing the batteries >
When the clock is set, the set time is saved in the indoor unit. After replacing the batteries,
direct the remote controller toward the indoor unit and press . (The time will be set
automatically.) If “12:00” keeps on blinking, follow steps 1 to 3 above.
To set the position where the indoor unit is installed
Set “INSTALLED POSITION” in the menu settings.
Page 31, 33
• To adjust the airow properly, set the “INSTALLED POSITION”.
To set the brightness of the indoor unit lamps
Press .
BRIGHTNESS High
(default)
BRIGHTNESS Low
BRIGHTNESS Off
Note on setting the clock
• If the indoor unit’s internal clock is not set to the correct time, the ON/OFF TIMER, COMFORT SLEEP TIMER and QUICK HEATING
TIMER will not operate punctually.
10
To set operation modes
AUTO operation
To operate in appropriate operation mode (COOLING or HEATING)
based on the set temperature and the indoor temperature.
Press .
COOLING operation
To lower the temperature.
Press .
“SARARA” DRY operation
To lower the humidity.
Press .
DRY COOLING operation
To lower the temperature and humidity.
Press during COOLING operation.
• Press during “SARARA” DRY operation to switch the
operation to DRY COOLING.
HEATING operation
To raise the temperature.
Press .
“URURU” HUMIDIFY operation
To raise the humidity.
Press while the unit is not
operating.
HUMID HEATING operation
To raise the temperature and humidity.
Press during HEATING
operation.
• Press the button again to go back to HEATING operation.
• Press
during HEATING operation or during “URURU”
HUMIDIFY operation to switch the operation to HUMID HEATING.
OPERATION lamp (green)
11
FAN ONLY operation
To blow air.
Press .
< To stop the operation >
Press .
To adjust the temperature
Press .
To adjust the humidity
Press .
Notes on humidity settings
SettingDescription
: MOISTURISING
: CONTINUOUSContinues humidifying or dehumidifying.
: HIGHHumidies or dehumidies with high power.
: STANDARDHumidies or dehumidies with moderate power.
: LOWHumidies or dehumidies with low power.
: OFFDoes not perform humidity control.
Notes on temperature and humidity settings in each operation mode
ModeTemperatureHumidity
AUTO18-30ºCThe humidity setting is not available.
COOLING
DRY COOLINGMOISTURISING, CONTINUOUS, LOW, STANDARD, HIGH or OFF *4
“SARARA” DRY*1CONTINUOUS, LOW, STANDARD or HIGH
HEATING
HUMID HEATINGOFF *6 , LOW, STANDARD, HIGH, CONTINUOUS or MOISTURISING
“URURU” HUMIDIFY*2LOW, STANDARD, HIGH or CONTINUOUS
*1 When the temperature is changed, the DRY COOLING operation starts.
*2 When the temperature is changed, the HUMID HEATING operation starts.
*3 When the humidity is lowered, the DRY COOLING operation starts.
*4 When “OFF” is selected, the COOLING operation starts.
*5 When the humidity is raised, the HUMID HEATING operation starts.
*6 When “OFF” is selected, the HEATING operation starts.
Keeps the humidity high and does not blow air directly on the body to make the operation gentle to your
skin.
The operation is recommended when you are worried about the dryness of your skin. The airow rate
cannot be changed.
18-32ºC
10-30ºC
*3
*5
Basic Operation
Notes on “SARARA” DRY operation
• This mode mixes dehumidied cool air with room air to adjust the air outlet temperature and remove moisture.
• When the indoor temperature rises, the DRY COOLING operation automatically starts.
• When the outdoor temperature is lower than the indoor temperature, dehumidifying is less effective.
• When the outdoor temperature is lower than 18ºC, the room is dehumidied by alternating the COOLING and HEATING operations. In
addition, the ventilation is controlled properly and the room humidity is lowered by taking outdoor air into the room. (Air intake
dehumidifying)
Notes on DRY COOLING operation
• In order to lower the humidity, the airow rate during the DRY COOLING operation becomes lower than that in the COOLING operation.
• When the humidity is not lowered, “SARARA” DRY operation automatically starts.
Note on “URURU” HUMIDIFY operation
• The humidifying unit collects moisture from the outdoor air to humidify the room.
Note on HUMID HEATING operation
• When the indoor temperature rises by HEATING operation, the indoor humidity may drop temporarily.
12
To adjust the airow
To adjust the airow rate
Press .
• Each time you press the button, the airow rate indicator changes.
(Some indicators may not appear depending on the operation mode.
.......
AUTOIndoor unit quietAirow rate 1-5
Page 14
)
• When the airow is set to “
sound from the unit will become quieter.
• If the temperature does not reach the desired point, change the airow rate setting.
”, indoor unit quiet operation will start and the operating
To adjust the airow direction
< To change the vertical airow direction >
Press .
• Each time you press the button, the airow direction indicator changes.
(Some indicators may not appear depending on the operation mode.
• The aps move vertically.
...
BREEZESwingingAUTOCirculation
< To change the horizontal airow direction >
Level 1-6
Press .
• Each time you press the button, the airow direction indicator changes.
(Some indicators may not appear depending on the setting of “INSTALLED POSITION”.
Page 33
• The louvres move horizontally.
)
Page 14
)
13
AUTO WideTo the left
To the rightSwinging
Front
blowing
< To combine vertical and horizontal airow directions (3-D airow) >
Set the vertical and
horizontal airow
directions to “Swinging”.
• The aps and louvres move alternately.
• To cancel 3-D airow, press
.
or
Swinging Swinging
Notes on airow rate
• When the airow rate setting is “AUTO”, starting COOLING, “SARARA” DRY, or DRY COOLING operation (including the operation
selected with “AUTO”) triggers the deodorising function which reduces odour coming from the indoor unit and the unit does not blow air
immediately. Wait for about 40 seconds. (SMELL PROOF)
• When the airow rate is lowered, the aps and louvres will stop. When the vertical airow direction is set to “Swinging”, the aps stop in
an upward direction.
• At smaller airow rates, the cooling/heating effect is also smaller.
< Airow rate settings in each operation mode >
ModeAirow rate setting
“SARARA” DRY / DRY COOLINGAUTO
AUTO / COOLING / HEATING / “URURU” HUMIDIFY / HUMID HEATING* / FAN ONLY AUTO, Indoor unit quiet, Airow rate 1-5
* When the humidity is set to “MOISTURISING”, the airow rate becomes “AUTO”.
Notes on vertical airow direction
“AUTO”, “Circulation” and “BREEZE” airow can be set according to the operation mode.
Circulation airow BREEZE airow
This setting blows air far using the space of the
ceiling. Moreover, air can be circulated in the whole
room by taking air from the shutter (bottom air inlet),
to eliminate the temperature variation.
< Settings of “AUTO”, “Circulation”, and “BREEZE” airow in each operation mode >
Mode
AUTO
COOLING / “SARARA” DRY / DRY COOLING
HEATING / “URURU” HUMIDIFY / HUMID HEATING––
FAN ONLY–
AUTOCirculation BREEZE
This setting automatically adjusts the airow rate and
vertical airow direction to generate a breeze-like
airow. It is a comfortable airow even when it blows
on your body.
Airow direction setting
––
Basic Operation
< Settings of “AUTO” airow in each operation mode >
ModeAirow direction setting
COOLING / DRY COOLING
HEATING / HUMID HEATINGDownward air blowing and circulation airow are repeated.
“SARARA” DRY
“URURU” HUMIDIFYCirculation
< Movable range of the aps >
The movable range of the aps varies according to the operation mode.
Circulation airow BREEZE airow
When the indoor temperature is a little lower Circulation airow
When the indoor temperature is a little higher BREEZE airow
COOLING / “SARARA” DRY /
DRY COOLING
HEATING /
“URURU” HUMIDIFY /
HUMID HEATING
FAN ONLY
CAUTION
• Always use a remote controller to adjust the angles of the aps and louvres. If you attempt to move the aps and louvres forcibly by
hand when they are swinging, the mechanism may be damaged.
• Always use a remote controller to adjust the louvres angles. Inside the air outlet, a fan is rotating at a high speed.
14