Daikin EKHWS150BA3V3, EKHWS200BA3V3, EKHWS300BA3V3, EKHWS200BA3Z2, EKHWS300BA3Z2 Installation manuals

INSTALLATION MANUAL
Domestic hot water tank for air to
water heat pump system
EKHWS150BA3V3 EKHWS200BA3V3 EKHWS300BA3V3
EKHWS200BA3Z2 EKHWS300BA3Z2
1
2
EKHWS150BA3V3 EKHWS200BA3V3 EKHWS200BA3Z2 EKHWS300BA3V3 EKHWS300BA3Z2
C
ONTENTS
Domestic hot water tank
for air to water heat pump system
age
P
Introduction........................................................................................ 1
General information ................................................................................... 1
Scope of this manual ................................................................................. 1
Model identification ....................................................................................1
Accessories ....................................................................................... 1
Accessories supplied with the domestic hot water tank............................. 1
Installation of the EKHWS domestic hot water tank.......................................... 2
Main components....................................................................................... 2
Outlook diagram......................................................................................... 3
Installation guidelines................................................................................. 3
Installing the domestic hot water tank........................................................ 3
Connecting the water circuits..................................................................... 3
Field wiring................................................................................................. 5
Maintenance ...................................................................................... 6
Troubleshooting ................................................................................. 7
General guidelines ..................................................................................... 7
General symptoms..................................................................................... 7
Technical specifications ..................................................................... 7
Domestic hot water tank specifications...................................................... 7
READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION. KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE REFERENCE.
IMPROPER INSTALLATION OR ATTACHMENT OF EQUIPMENT OR ACCESSORIES COULD RESULT IN ELECTRIC SHOCK, SHORT-CIRCUIT, LEAKS, FIRE OR OTHER DAMAGE TO THE EQUIPMENT. BE SURE ONLY TO USE ACCESSORIES MADE BY DAIKIN WHICH ARE SPECIFICALLY DESIGNED FOR USE WITH THE EQUIPMENT AND HAVE THEM INSTALLED BY A PROFESSIONAL.
IF UNSURE OF INSTALLATION PROCEDURES OR USE, ALWAYS CONTACT YOUR DAIKIN DEALER FOR ADVICE AND INFORMATION.
THE UNIT DESCRIBED IN THIS MANUAL IS DESIGNED FOR INDOOR INSTALLATION ONLY AND FOR AMBIENT TEMPERATURES RANGING 0°C~35°C.
Installation manual

Scope of this manual

This installation manual describes the procedures for unpacking, installing and connecting the EKHWS domestic hot water tanks.
Model identification
EK HWS 150 BA 3 V3
Booster heater voltage V3 = 1P, 230 V Z2 = 2P, 400 V (only for 200 l and 300 l models)
Capacity booster heater: 3 kW
Series
Indication of storage capacity in litres
Hot Water tank Stainless steel
European Kit
CCESSORIES
A

Accessories supplied with the domestic hot water tank

See figure 1
1
Thermistor + connection wire (12 m)
2
Contactor - fuse assembly
3
Contactor fixing screw
4
Tapping screw
5
Installation manual
6
3-way valve + motor
NOTE
For accessories supplied with the EKHWSU domestic hot water tank, refer to the manual supplied with the tank.
I
NTRODUCTION

General information

Thank you for purchasing this domestic hot water tank.
The EKHWS domestic hot water tank with integrated 3 kW electrical booster heater can be connected to the indoor unit. The domestic hot water tank is available in three sizes: 150, 200 and 300 litre. All models are floor mounted. The 200 and 300 litre models are also available as 400 V versions.
NOTE
EKHWS150~300BA3V3 + EKHWS200+300BA3Z2
Domestic hot water tank for air to water heat pump system
4P610547-1 – 2020.01
Especially for the United Kingdom
For installation of an EKHWSU domestic hot water tank, refer to the installation manual supplied with the tank.
Installation manual
1
I
NSTALLATION OF THE
WATER TANK
EKHWS
DOMESTIC HOT

Following descriptions are only for EKHWS*V3 and EKHWS*Z2 models, not for EKHWSU*V3 models

The total
system (indoor unit
and outdoor unit) is designed for combination with an
domestic hot water tank. In case
another tank is being used in combination with the
indoor unit, Daikin cannot guarantee neither good operation nor reliability of the system. For those reasons Daikin cannot give warranty of the system in such case.
The equipment is not intended for use in a potentially explosive atmosphere.
Domestic hot water quality must be according to EN directive 98/83 EC.
A drain device should be installed on the cold water connection on the domestic hot water tank.
For safety reasons, it is not allowed to add ethylene glycol to the water circuit. Adding ethylene glycol might lead to contamination of the domestic water if a leakage would occur in the heat exchanger coil.
It is important that the storage capacity of the domestic hot water tank meets normal daily fluctuations in consumption of domestic hot water without any fall of the water outlet temperature during use.
Immediately after installation, the domestic hot water tank must be flushed with fresh water. This procedure must be repeated at least once a day the first 5 consecutive days after installation.

Main components

In case of limited consumption of domestic hot water, e.g. at holiday residences or at houses that are occasionally not occupied, the domestic hot water tank installation must be fitted with a shunt pump.
The shunt pump can be time-controlled,
the shunt pump must operate to circulate the complete volume of the domestic hot water tank 1.5 times per hour,
and the shunt pump must operate, or be programmed for operation, during 2 uninterrupted hours per day at least.
2
3
1
4
1 Cold water connection
2 Hot water connection
3 Shunt pump
(field supply)
4 Non-return valve
(field supply)
In case of very long field water piping between the domestic hot water tank and the hot water end point (shower, bath, etc.) it can take more time before the hot water from the domestic hot water tank reaches the hot water end point.
1 Shower
1
2
2 Recirculation pump
1
Field supply
2
Hot water connection
3
Pressure relief valve connection
4
Pressure relief valve (field supply)
5
Electrical box
6
Electrical box lid
7
Recirculation hole
8
Thermistor socket
9
Flow inlet connection
10
Heat exchanger coil
11
Return outlet connection
12
Cold water connection
13
Threaded thermistor hole
If required connect a recirculation pump in between the hot water end point and the recirculation hole in the domestic hot water tank.
Installation manual
2
Domestic hot water tank for air to water heat pump system
EKHWS150~300BA3V3 + EKHWS200+300BA3Z2
4P610547-1 – 2020.01