Daikin RMKS112LV1A, RMXS112LV1A, RMKS140LV1A, RMXS140LV1A, RMKS160LV1A Service Manual

...
REMOVAL
PROCEDURE
SERVICE MANUAL
Outdoor Unit
Inverter
Multi Type
11.2/14.0/16.0 kW Class 48000 Btu/h Class
Si181296_A
Service Manual Removal Procedure
Outdoor Unit
zCooling Only zHeat Pump
RMKS112LV1A RMXS112LV1A RMKS140LV1A RMXS140LV1A RMKS160LV1A RMXS160LV1A
RMXS48LVJU
zBP Unit
BPMKS967A2 BPMKS967A3
BPMKS048A2U BPMKS049A3U
Si181296_A
Removal Procedure 1
Table of Contents
1. Outdoor Unit............................................................................................2
1.1 Outer Panels ............................................................................................2
1.2 PCBs / Electrical Components .................................................................4
1.3 Outdoor Fans / Fan Motors ....................................................................12
1.4 Thermistors ............................................................................................13
1.5 Electronic Expansion Valves / Peripheral Equipments...........................14
1.6 Four Way Valve......................................................................................17
1.7 Compressor............................................................................................18
2. BP Unit ..................................................................................................21
2.1 PCB Assembly .......................................................................................21
2.2 Electronic Expansion Valve Coils...........................................................23
Note:
The illustrations may be slightly different depending on the model.
The illustrations are for heat pump models as representative.
Outdoor Unit Si181296_A
2 Removal Procedure
1. Outdoor Unit
1.1 Outer Panels
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work.
Step
Procedure Points
1
2
3
4
5
6
7
Remove the 8 screws and remove the top panel.
Remove the screw of the front panel (2).
Push the front panel (2) downward to release the hook and remove it.
Remove the screw and remove the piping cover (front).
Remove the 4 screws and remove the piping cover (rear).
Slide the outdoor temperature thermistor to the right and detach it.
Remove the 6 screws and remove the right side panel.
It is possible to remove only the front panel (2) without removing the top panel.
Top panel
(R12962)
Front panel (2)
Piping cover (front)
(R18289)
Outdoor temperature thermistor
Right side panel
Piping cover (rear)
Si181296_A Outdoor Unit
Removal Procedure 3
8 The outdoor unit has 2
discharge grilles. Remove the 4 screws and unfasten the 4 hooks to remove a discharge grille.
U.S. model: The front panel (1) has 2 air outlet protection nets. To detach an air outlet protection net, remove the 4 screws.
910Remove the 7 screws
of the front panel (1).
Push the front panel (1) upward and remove it.
On the rear side of the front panel (1), a reinforce plate is attached. Be careful not to lose it while removing the front panel (1).
Step
Procedure Points
Discharge grille
Discharge grille
Hook
Hook
Hook
Front panel (1)
(R18960)
Reinforce plate
(R18961)
Outdoor Unit Si181296_A
4 Removal Procedure
1.2 PCBs / Electrical Components
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work.
Step
Procedure Points
1. Remove the terminal cover (The U.S. models only).
M5(2) × 12
1 Remove the screw on
the terminal cover (upper) and open the terminal cover (upper).
2 Remove the screw and
open the terminal cover (lower).
M5(3) × 12
3 Remove the 2 screws
and remove the terminal covers.
M5(3) × 12
Terminal cover (upper)
Screw
(R18962)
Terminal cover (lower) Screw
Terminal mounting
plate
(R18963)
(R18964)
Screw
Si181296_A Outdoor Unit
Removal Procedure 5
2. Remove the PCBs and electrical components.
M5(3) × 12
1 Remove the 2 screws
of the terminal mounting plate. (Except the U.S. models.)
2 Remove the screw
above the electrical component assembly.
M5(3) × 12
3 Unfasten the clamp
from the terminal mounting plate.
Step
Procedure Points
(R12966)
Terminal mounting plate
(R9220)
(R18065)
Outdoor Unit Si181296_A
6 Removal Procedure
4 Cut off the 3 clamps.
5 Disconnect the relay
connector for the reactor lead wire from each other.
Step
Procedure Points
(R18066)
(R18067)
(R18068)
(R9225)
Si181296_A Outdoor Unit
Removal Procedure 7
6 Disconnect the
connectors [X106A] [X107A].
[X106A] [X107A]: fan motor
7 Release the fan motor
lead wires from the hooks.
8 Release the lead wires
of the solenoid valves and four way valve from the fixing plate and then remove the electrical component assembly.
Step
Procedure Points
(R12967)
[X106A] [X107A]
(R9227)
(R9228)