Surface Mount
To + VDC (fuse @ 3A): |
RED |
To Chassis Ground: |
BLACK |
For Synchronization: YELLOW
Connect YELLOW wires of all heads together for synchronization (All heads must be set at the same pattern)
For Simultaneous or Alternating Flash:
1.Apply +VDC to RED and YELLOW wires simultaneously to enter Grouping mode; lighthead will display short (single or double) flashes:
˙Single flash = Group1 |
˙Double flash = Group2 |
2.Remove YELLOW wire from +VDC and momentarily apply to +VDC to change Groups:
˙Heads in the same Group flash together. ˙Group1 Heads alternate with Group2 Heads.
For Flash Pattern, momentarily apply +VDC to YELLOW wire:
˙once for next pattern ˙quickly three times for reset (see flash pattern chart)
Flash Patterns
1 |
Single (2Hz) |
13 |
Single H/L (split) |
2 |
Double (2Hz) |
14 |
Single (all) |
3 |
Triple (2Hz) |
15 |
Double (all) |
4 |
Quad (2Hz) |
16 |
Quad (all) |
5 |
Random |
17 |
Quint (all) |
6 |
Single (split) |
18 |
Mega (all) |
7 |
Double (split) |
19 |
Ultra (all) |
8 |
Quad (split) |
20 |
Single-Quad (all) |
9 |
Quint (split) |
21 |
Single H/L (all) |
10 |
Mega (split) |
22 |
Steady 2 (california) |
11 |
Ultra (split) |
23 |
Steady 4 (all) |
12 |
Single-Quad (split) |
|
|
120523