Classe Audio 10, DR-10 Service manual

4.5 (2)

 

Date:

August 27, 2007

 

Model Number:

DR-10 / MODEL 10

Classé Audio Inc.

Subject:

Service manual

 

 

 

 

Classé Audio, Inc. 5070 François Cusson Lachine, Québec Canada H8T1B3, www.classeaudio.com

PRO-SVR_LEGACY

Page 1 of 10

Table of Contents

Introduction 3

Important Notes on Servicing 3

Ordering Replacement Parts 3

Block Diagrams 4

Start up Procedure 5

Protection Modes and Indicators 6

Troubleshooting Guide 7

Output Transistors Testing and Replacement 8

Calibrations and Adjustments 9

Fuses 10

Schematics 11

The contents of this document as well as the files associated with it contain confidential information that is proprietary to Classé Audio Incorporated and are intended solely for the purpose of servicing product. No part of its contents may be used, copied, disclosed, or conveyed to any party in any manner whatsoever without prior written permission from Classé Audio Incorporated.

PRO-SVR_LEGACY

Page 2 of 10

Introduction

Please read this manual carefully before commencing servicing!

Only qualified and authorized personnel should attempt to service this product.

The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated dangerous voltage within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.

The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions.

Classé has a global product support network. For product assistance or to order replacement parts please contact your nearest service center always quoting the unit serial number.

North America

Phone: (978) 664-2870 E-mail: classe@bwgroupusa.com

Europe

Phone: 44 (0) 1903 221 700 E-mail: classe@bwgroup.com

Asia

Phone: (852) 2790 8903 E-mail: classe@bwgroup.hk

Rest of the World

Phone: (514) 636-6384 E-mail: cservice@classeaudio.com

Important Notes on Servicing

1.ALWAYS observe ESD precautions when handling electronic modules or PCBAs.

2.NEVER exchange boards with a different revision number, unless authorized by Classé.

3.ALWAYS use Classé original replacement parts. The use of generic parts may void the warranty of

the unit.

Ordering Replacement Parts

There may be a delay in processing incomplete requests. Please be sure to include all required information. Remember to quote the serial number of the unit on all replacement part orders and the Classé order number when returning defective parts for credit.

PRO-SVR_LEGACY

Page 3 of 10

Classe Audio 10, DR-10 Service manual

Block diagrams

PRO-SVR_LEGACY

Page 4 of 10

Start Up Procedure

When receiving a unit, an assiduous visual inspection must be performed. Do not connect the unit without analysing the symptoms reported by the customer and the results of the inspection.

Using the troubleshooting guide, find the problem and proceed to the repair. Once this step is done, follow these steps, known as the start-up procedure, to ensure that everything in the unit is in working condition.

1.Proceed with a post repair visual inspection. Take the time to check if every wire is reconnected properly, every screw is bolted on, no soldering and/or metal residues lying in the unit, every fuse has been replaced, etc.

2.Connect the unit to a variable transformer, setted to 0Vac.

3.Turn the bias trimpot (R17) counter clockwise until a click is heard.

4.Slowly raise the voltage to 10Vac, and check positive and negative rails and pre-driver supply. Check fuses.

5.If one or more supply are not within specifications, return to the troubleshooting guide.

6.Slowly raise voltage until you hear relays click, this point is around 55Vac. Recheck every supply.

7.If one or more supply are not within specifications, return to the troubleshooting guide.

8.Raise voltage to 120Vac. Recheck every supply

9.Report to Calibration and adjusments to adjust bias and DC offset. Note that bias can be adjusted to 14mV, and the following tests can be performed before the unit is send to the burn-in bench for a 24 hours warm-up.

10.Connect the unit to a load, and to a source using balanced inputs and single ended inputs, independently.

11.Perform a test with a 200Hz, a 2kHz and a 20kHz tone, both sinus wave and square wave. Check the output with a oscilloscope, on 4 ohms and 8 ohms loads. Take special cares about oscillation and phase correlation between channels.

12.Connect the unit to a small speaker, and short the input. Check for any noise. Perform this step with single ended inputs and balanced inputs, independently.

13.Put the unit on a burn-in bench, and let it sit for 24 hours, then readjust bias. Let the unit on the burnin bench for another 72 hours.

14.Redo steps 10 to 13 before shipping to the customer.

PRO-SVR_LEGACY

Page 5 of 10

Loading...
+ 11 hidden pages