See Warranty on page 10 for important information about commercial use of this product.
Operating Instructions SB660000
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference.
3-in-1 Finish
Nailer / Stapler
Table of Contents
Description . . . . . . . . . . . . . . . . . . . . . 1
Unpacking . . . . . . . . . . . . . . . . . . . . . . 1
Safety Guidelines . . . . . . . . . . . . . . . . 1
Important Safety Information . . . . . . 1
Tool Components and
Specifications. . . . . . . . . . . . . . . . . . . . 2
Operating Instructions . . . . . . . . . . . . 4
Lubrication . . . . . . . . . . . . . . . . . . . . 4
Recommended Hookup. . . . . . . . . . 4
Operational Mode . . . . . . . . . . . . . . 5
Work Contact Element (WCE). . . . . 5
Loading/Unloading The Tool. . . . . . 5
Adjusting the Fastener
Penetration. . . . . . . . . . . . . . . . . . . . 6
Adjusting the Direction
of the Exhaust . . . . . . . . . . . . . . . . . 6
User-Maintenance Instructions . . . . . 6
Clearing A Jam From The Tool . . . . 6
Technical Service . . . . . . . . . . . . . . . 6
Fastener And Replacement Parts . . 6
Tool Repair . . . . . . . . . . . . . . . . . . . . 6
Assembly Procedure For Seals. . . . . 6
Fasteners . . . . . . . . . . . . . . . . . . . . . . . 7
Troubleshooting Chart . . . . . . . . . . . . 9
Warranty . . . . . . . . . . . . . . . . . . . . . . 10
Description
This tool, which drives 3 different types of fasteners (18 gauge brads, 18 gauge 1/4 inch crown staples, and 16 gauge finish nails) is designed for decorative trim, molding, window casings, furniture trim, picture frame assembly, cabinetry, setting pre-hung doors, casebacks, and crafts. Features include: convenient top and side loading magazine which holds up to 100 fasteners, adjustable depth control, rubber grip, adjustable exhaust, and quick clear nose.
Unpacking
After unpacking the unit, inspect carefully for any damage that may have occurred during transit. Make sure to tighten fittings, bolts, etc., before putting unit into service.
Safety Guidelines
This manual contains information that is very important to know and understand. This information is provided for SAFETY and to PREVENT EQUIPMENT PROBLEMS. To help recognize this information, observe the following symbols.
Danger indicates
an imminently hazardous situation which, if not avoided, WILL result in death or serious injury.
Warning indicates
a potentially hazardous situation which, if not avoided, COULD result in death or serious injury.
Caution indicates
a potentially hazardous situation which, if not avoided, MAY result in minor or moderate injury.
Notice indicates
important information, that if not followed, may cause damage to equipment.
NOTE: Information that requires special attention.
Important Safety Instructions
INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS
This manual contains safety, operational and maintenance information. Contact your Campbell Hausfeld representative if you have any questions.
Model SB660000
Locate model and date code on tool and record below:
Model No.: _____________________ Date Code: _____________________
Retain these numbers for
future reference.
When using tools,
basic precautions should always be followed, including the following:
CALIFORNIA PROPOSITION 65
This product or
its power cord may contain chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. Wash hands after handling.
You can create dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement, or other masonry. This dust often contains chemicals known to cause cancer, birth defects, or other reproductive harm. Wear protective gear.
REMINDER: Keep your dated proof of purchase for warranty purposes!
Attach it to this manual or file it for safekeeping.
Campbell Hausfeld Nailers meet or exceed Industries’ Standards as set forth by the American National Standard Institute/International Staple, Nail and Tool Association in ANSI/ISANTA SNT-101-2002.
For parts, product & service information
visit www.chpower.com
IN734600AV 9/10
Operating Instructions SB660000
Important Safety Instructions (Continued)
GENERAL
a. To reduce the risks of
electric shock, fire, and injury to persons, read all the instructions before
using the tool.
b. Be thoroughly familiar with the
controls and the proper use of the equipment. Follow all instructions. Contact your Campbell Hausfeld representative if you have any questions.
c. Only persons well acquainted with
these rules of safe operation should be allowed to use the unit.
Read and
understand tool labels and manual. Failure to follow warnings, dangers, and cautions could result in DEATH or SERIOUS INJURY.
WORK AREA
a. Keep the work area clean and well
lighted. Cluttered benches and dark
areas increase the risks of electric shock, fire, and injury to persons.
b. Do not operate the tool
in explosive atmospheres, such as in the presence of flammable liquids, gases, or dust. The tool is able to create
sparks resulting in the ignition of the dust or fumes.
c. Keep bystanders, children, and
visitors away while operating the tool. Distractions are able to result in
the loss of control of the tool.
PERSONAL SAFETY
a. Stay alert. Watch what you are
doing and use common sense when operating the tool. Do not use the tool while tired or under the influence of drugs, alcohol, or medication. A moment of
inattention while operating the tool increases the risk of injury to persons.
b. Dress properly. Do not wear loose
clothing or jewelry. Contain long hair. Keep hair, clothing, and gloves away from moving parts.
Loose clothes, jewelry, or long hair increases the risk of injury to persons as a result of being caught in moving parts.
c. Avoid unintentional starting.
Be sure the switch is off before connecting to the air supply. Do not
carry the tool with your finger on the switch or connect the tool to the air supply with the switch on.
d. Do not overreach. Keep proper
footing and balance at all times.
Proper footing and balance enables better control of the tool in unexpected situations.
e. Use safety equipment. A dust mask,
non-skid safety shoes and a hard hat must be used for the applicable conditions.
f. Always wear eye
protection.
g. Always wear hearing
protection when using the tool. Prolonged
exposure to high intensity noise is able to cause hearing loss.
h. Do not attach the hose or tool to
your body. Attach the hose to the structure to reduce the risk of loss of balance if the hose shifts.
i. Always assume that the tool
contains fasteners. Do not point the tool toward yourself or anyone whether it contains fasteners or not.
j.
nail. This is able to cause the nail to be deflected and hit someone, or cause the tool to react and result in a risk of injury to persons.
Do not nail on
top of another
k. Remove finger
from the trigger when not driving fasteners. Never carry the tool with finger on trigger,
the tool is able to fire a fastener.
Always remain in a
firmly balanced position when using or handling the tool.
Avoid long extended
periods of work with the tool. Stop using the tool if you feel pain in hands or arms.
Tool Components and Specifications
 • REQUIRES: 0.7 SCFM with
10 fasteners per minute @ 90 psi
 •AIR INLET: 1/4 inch NPT  • MAGAZINE CAPACITY:
100+ Fasteners per Load
 • BRADS: 3/8 inch to 2 inch, 18 gauge  • FINISH NAILS: 3/4 inch to 2-1/2 inch, 16 gauge
 • STAPLES: 1/2 inch to 1-5/8 inch;
1/4 inch crown
 • WEIGHT: 5 lbs. 7 oz.  • LENGTH: 12-3/4 inches  • HEIGHT: 12 inches  • MAXIMUM PRESSURE:
120 psi
 • PRESSURE RANGE:
60 psi – 120 psi
www.chpower.com
Depth Control
Work Contact
Element (WCE)
Adjustable
Quick
Clear
Nose
Adjustable Exhaust
Trigger
Magazine Rail
18 gauge Nail Ribs
Fastener Discharge Area
16 gauge Nail Slot
Magazine
Latch Button
2
Operating Instructions SB660000
Important Safety Instructions (Continued)
TOOL USE AND CARE
a. Use clamps or another practical way
to secure and support the workpiece to a stable platform. Holding the
work by hand or against the body is unstable and is able to lead to loss of control.
b. Do not force the tool. Use the
correct tool for the application. The correct tool will do the job better and safer at the rate for which the tool is designed.
c. Do not use the tool if the switch
does not turn the tool on or off. Any tool that cannot be controlled with the switch is dangerous and must be repaired.
d.
source before making adjustments, doing tool maintenance, clearing jams, leaving work area,loading, or unloading the tool. Such
precautionary measures reduce the risk of injury to persons.
e. Store the tool when it is idle out
of reach of children and other untrained persons. A tool is
dangerous in the hands of untrained users.
f. Maintain the tool with care. Keep
a cutting tool sharp and clean. A properly maintained tool, with sharp cutting edges reduces the risk of binding and is easier to control.
g. Check for misalignment or binding
of moving parts, breakage of parts, and any other condition that affects the tool’s operation. If damaged,
have the tool serviced before using. Many accidents are caused by poorly maintained tools. There is a risk of bursting if the tool is damaged.
h. Use only those fasteners listed
in the Accessories section of this manual. Fasteners not identified
for use with this tool by the tool manufacturer are able to result in a risk of injury to persons or tool damage when used in this tool.
i. Select an appropriate tool actuation
system, taking into consideration the work application for which the tool is used.
Disconnect the
tool from the air
Never use
gasoline or other flammable liquids to clean the tool. Never use the tool in the presence of flammable liquids or gases. Vapors could ignite by a spark and cause an explosion which will result in death or serious personal injury.
Do
not remove, tamper with, or otherwise cause the trigger lock or trigger to become inoperable. Do not operate any tool which has been modified in a like fashion. Death or serious personal injury could result.
Do
not touch the trigger unless driving fasteners. Never attach air line to tool or carry tool while touching the trigger. The tool could eject a fastener which will result in death or serious personal injury. Also actuate the trigger lock to the safe position when not in use.
Always disconnect the tool from the power source when unattended, performing any maintenance or repair, clearing a jam, or moving the tool to a new location. Do not load the tool with fasteners when the trigger is depressed. The tool could eject a fastener causing death or serious personal injury.
Always fit tool with a fitting or hose coupling on or near the tool in such a manner that all compressed air in the tool is discharged at the time the fitting or hose coupling is disconnected. Do not use a check valve or any other fitting which allows air to remain in the tool. Death or serious personal injury could occur.
Never
place hands or any other body parts in the fastener discharge area of the tool. The tool might eject a fastener and could result in death or serious personal injury.
Never
carry the tool by the air hose or pull the hose to move the tool or a compressor. Keep hoses away from heat, oil and sharp edges. Replace any hose that is damaged, weak or worn. Personal injury or tool damage could occur.
3
Always assume the
fasteners. Respect the tool as a working implement; no horseplay. Always keep others at a safe distance from the work area in case of accidental discharge of fasteners. Do not point the tool toward yourself or anyone whether it contains fasteners or not. Accidental triggering of the tool could result in death or serious personal injury.
Do
drive a fastener on top of other fasteners. The fastener could glance and cause death or a serious puncture wound.
Do not operate or allow anyone else to operate the tool if any warnings or warning labels are not legible. Warnings or warning labels are located on the tool magazine and body.
Do not drop or
Dropping or throwing the tool can result in damage that will make the tool unusable or unsafe. If the tool has been dropped or thrown, examine the tool closely for bent, cracked or broken parts and air leaks. STOP and repair before using or serious injury could occur.
Avoid using the
magazine is empty. Accelerated wear on the tool may occur.
Clean and check all
and fittings before connecting the tool to an air supply. Replace any damaged or worn hoses or fittings. Tool performance or durability may be reduced.
tool contains
not
!
throw the tool.
tool when the
air supply hoses
WARNING
SERVICE
a. Tool service must be performed only
by qualified repair personnel.
b. When servicing a tool, use only
identical replacement parts. Use only authorized parts.
c. Use only the lubricants supplied
with the tool or specified by the manufacturer.
Do not make any
modifications to the tool without first obtaining written approval from Campbell Hausfeld. Do not use the tool if any shields or guards are removed or altered. Do not use the tool as a hammer. Personal injury or tool damage may occur.
www.chpower.com
Operating Instructions SB660000
Important Safety Instructions (Continued)
Disconnect air
supply and release tension from the pusher before attempting to clear jams because fasteners can be ejected from the front of the tool. Personal injury may occur.
AIR SOURCE
a. Never connect to an air source that
is capable of exceeding 200 psi.
Over pressurizing the tool is able to result in bursting, abnormal operation, breakage of the tool or serious injury to persons. Use only clean, dry, regulated compressed air at the rated pressure or within the rated pressure range as marked on the tool. Always verify prior to using the tool that the air source has been adjusted to the rated air pressure or within the rated air-pressure range.
b. Never use oxygen, carbon dioxide,
combustible gases or any bottled gas as an air source for the tool.
Such gases are capable of explosion and serious injury to persons.
O
CO
Do not use any type of reactive gases, including, but not limited to, oxygen and combustible gases, as a power source. Use filtered, lubricated, regulated compressed air only. Use of a reactive gas instead of compressed air may cause the tool to explode which will cause death or serious personal injury.
2
Use only a pressure-regulated compressed air source to limit the air pressure supplied to the tool. The regulated pressure must not exceed 120 psi. If the regulator fails, the pressure delivered to the tool must not exceed 200 psi. The tool could explode which will cause death or serious personal injury.
120 psi
SAVE THESE INSTRUCTIONS
DO NOT DISCARD
Operating Instructions
LUBRICATION
This tool requires lubrication before using the tool for the first time and before each use. If an inline oiler is used, manual lubrication through the air inlet is not required on a daily basis.
The work surface
can become damaged by excessive lubrication. Proper lubrication is the owner’s responsibility. Failure to lubricate the tool properly will dramatically shorten the life of the tool and void your warranty.
1. Disconnect the air
supply from the tool to add lubricant.
2. Turn the tool so the
air inlet is facing up. Place 4-5 drops of 30 W non-detergent oil into air inlet. Do not use detergent oils, oil additives, or air- tool oils. Air tool oils contain solvents which will damage the tool's internal components.
3. After adding oil, run
tool briefly. Wipe off any excess oil from the cap exhaust.
RECOMMENDED HOOKUP
The illustration below shows the recommended hookup for the tool.
1. The air compressor must be able to maintain a minimum of 60 psi when the
60 psi Min.
120 psi Max.
tool is being used. An inadequate air supply can cause a loss of power and inconsistent driving.
2. An oiler can be used to provide oil circulation through the tool. A filter can be used to remove liquid and solid impurities which can rust or “gum up” internal parts of the tool.
3. Always use air supply hoses with a minimum working pressure rating equal to or greater than the pressure from the power source if a regulator fails, or 150 psi, whichever is greater. Use 1/4 inch air hose for runs up to 50 feet. Use 3/8 inch or greater air hoses for 50 foot run or longer.
150 psi or greater
4. Use a pressure regulator on the compressor, with an operating pressure of 0 psi - 125 psi. A pressure regulator is required to control the operating pressure of the tool between 60 psi and 120 psi.
Minimum Recommended Hookup
Quick
Quick Plug
www.chpower.com
Coupler
Quick Plug
Quick
Coupler
Air Hose
4
Operating Instructions SB660000
Operating Instructions (Continued)
OPERATIONAL MODE - SINGLE CYCLE
Always know the
operational mode of the tool before using. Failure to know the operational mode could result in death or serious personal injury.
This tool requires the trigger to be pulled each time a nail is driven. The nailer can be actuated by depressing the Work Contact Element (WCE) against the work surface followed by pulling the trigger.
The trigger must be released to reset the tool before another nail can be driven.
WORK CONTACT ELEMENT (WCE)
Check the operation
of the Work Contact Element (WCE) trip mechanism before each use. The WCE must move freely without binding through its entire travel distance. The WCE spring must return the WCE to its fully extended position after being depressed. Do not operate the nailer if the WCE trip mechanism is not operating properly. Personal injury may occur.
1. Disconnect the air
supply from the tool.
5. Depress the WCE against the work surface without pulling the trigger. The tool MUST NOT OPERATE. Do not use the tool if it operates without pulling the trigger. Personal injury may result.
6. Remove the tool from the work surface. The WCE must return to its original down position. The tool MUST NOT OPERATE. Do not use the tool if it operates while lifted from the work surface. Personal injury may result.
7. Pull the trigger and depress the WCE against the work surface. The tool MUST NOT OPERATE.
8. Depress the WCE against the work surface. Pull the trigger. The tool MUST OPERATE.
An improperly
functioning tool must not be used. Do not actuate the tool unless the tool is placed firmly against the work piece.
3a. For 18 gauge nails, insert a stick
of Campbell Hausfeld nails or equivalent (see “Fasteners” section) into the magazine against the ribs. Make sure the pointed ends of the fasteners are resting on the bottom ledge of the magazine when loading. Make sure the nails are not dirty or damaged.
3b. For 16 gauge nails, insert the nail
points down into the slot next to the rail.
Magazine Rail
3c. For staples, load a clip of staples
with the crowns straddling the magazine rail.
2. Remove all fasteners from the magazine (see Loading/ Unloading).
3. Make sure the trigger and WCE move freely up and down without sticking or binding.
4. Reconnect air supply to the tool.
LOADING/UNLOADING THE NAILER
1. Always disconnect the tool from the air supply before loading fasteners.
2. Push down on
Latch
Button
the latch button. Pull back on the magazine cover.
5
Magazine Rail
4. Push the magazine cover forward until latch button pops up.
5. Always unload all fasteners before removing tool from service. Unloading is the reverse of loading, except that you must disconnect the air supply before unloading.
www.chpower.com
Operating Instructions SB660000
Operating Instructions (Continued)
ADJUSTING THE FASTENER PENETRATION
The tool is equipped with an adjustable depth of drive feature. This allows the user to determine how deep a fastener will be driven into the work surface.
1. Adjust operating pressure so nails are driven consistently. Do not exceed 120 psi.
2. To drive the nail shallower, turn the wheel (C) to right to the extent desired.
3. To sink a nail deeper, turn the wheel (C) to left to the extent desired.
4. Make sure trigger and WCE move freely up and down without binding or sticking after each adjustment.
ADJUSTING THE DIRECTION OF THE EXHAUST
The tool is equipped with an adjustable direction exhaust deflector. This is intended to allow the user to change the direction of the exhaust. Simply twist the deflector to any direction desired.
(C)
Rotate
User - Maintenance Instructions
CLEARING A JAM FROM THE TOOL
1. Disconnect the air supply from the nailer.
2. Remove all nails from the magazine (see Loading/ Unloading). Failure to do so will cause the nails to eject from the front of the tool.
3. Undo latch by pulling out and down. The wire latch will disengage from the hooks on the nose.
4. The door can now be rotated, exposing the jammed fastener.
5. Remove the jammed fastener, using pliers or a screwdriver if required.
6 Rotate door back into
the closed position.
7. Extend the wire latch and place over the hooks on the nose.
8. Close the latch by pushing the latch up and in until the latch snaps into place.
TECHNICAL SERVICE
Please call our Tool Hotline at 1-800­543-6400 with any questions regarding the operation or repair of this tool or for additional copies of this manual.
FASTENER AND REPLACEMENT PARTS
Use only genuine
Campbell Hausfeld 18 gauge fasteners (or equivalent - see Fastener Interchange Information). Tool performance, safety and durability could be reduced if improper fasteners are used. When ordering replacement parts or fasteners, specify by part number.
TOOL REPAIR
Only qualified personnel should repair the tool and they should use genuine Campbell Hausfeld replacement parts and accessories, or parts and accessories which perform equivalently.
ASSEMBLY PROCEDURE FOR SEALS
When repairing a tool, the internal parts must be cleaned and lubricated. Parker O-lube or equivalent must be used on all o-rings. Each o-ring must be coated with O-lube before assembling. A small amount of oil must be used on all moving surfaces and pivots. After reassembling, a few drops of 30W non-detergent oil or equivalent, must be added through the air line before testing.
STORAGE
The tool should be stored in a cool dry place.
www.chpower.com
9. Make sure the trigger and WCE move freely up and down without sticking or binding.
6
Operating Instructions SB660000
Fasteners
18 GAUGE BRAD NAILS
The following Campbell Hausfeld Brad nails are available at local retail stores. For help locating any item, call customer service at 1-800-543-6400. Campbell Hausfeld nails meet or exceed ASTM Standard F1667.
Nails Per
Model Length Shank Gauge Finish Head Collation
FB180016 5/8 inch 18 Gauge Galvanized Brad / Brown Adhesive 100 1000 FB180025 1 inch 18 Gauge Galvanized Brad / Brown Adhesive 100 1000 FB180030 1-1/4 inch 18 Gauge Galvanized Brad / Brown Adhesive 100 1000 FB180040 1-1/2 inch 18 Gauge Galvanized Brad / Brown Adhesive 100 1000 FB180050 2 inch 18 Gauge Galvanized Brad / Brown Adhesive 100 1000
This tool drives most brands of brad nails with these specifications:
• Length:3/8 inch to 2 inch
• Gauge:18
Stick
Nails Per
Box
16 GAUGE FINISH NAILS
The following Campbell Hausfeld finishing nails are available at local retail stores. If you need help locating any item, call customer service at 1-800-543-6400. Campbell Hausfeld nails meet or exceed ASTM Standard F1667.
Nails Per
Model Length Shank Gauge Finish Head Collation
FB160025 1” 16 Gauge Galvanized Brad Adhesive 50 1000 FB160040 1-1/2” 16 Gauge Galvanized Brad Adhesive 50 1000 FB160050 2” 16 Gauge Galvanized Brad Adhesive 50 1000 FB160065 2-1/2” 16 Gauge Galvanized Brad Adhesive 50 1000
This tool drives most brands of finish nails with these specifications:
• Length:3/4 inch to 2-1/2 inch
• Gauge:16
Stick
Nails Per
Box
7
www.chpower.com
Operating Instructions SB660000
Fasteners
CROWN STAPLES
The following Campbell Hausfeld staples are available at local retail stores. If you need help locating any item, call customer service at 1-800-543-6400. Campbell Hausfeld staples meet or exceed astm Standard F1667.
Wire
Model Length
FN180615 1/2 inch 18 Gauge 1/4 inch Chisel Galvanized / Vinyl Coated Adhesive 100 1000 FN180620 3/4 inch 18 Gauge 1/4 inch Chisel Galvanized / Vinyl Coated Adhesive 100 1000 FN180625 1 inch 18 Gauge 1/4 inch Chisel Galvanized / Vinyl Coated Adhesive 100 1000 FN180630 1-1/4 inch 18 Gauge 1/4 inch Chisel Galvanized / Vinyl Coated Adhesive 100 1000
This tool drives most brands of 1/4 inch crown staples with these specifications:
• Length:1/2 inch to 1-5/8 inch
• Gauge:18
Diameter
Crown
Size Point Finish Collation
Staples
Per Stick
Staples
Per Box
www.chpower.com
8
Operating Instructions SB660000
Troubleshooting Chart
Stop using tool immediately if any of the following problems occur. Serious personal injury could occur.
Any repairs or replacements must be done by a Qualified Service Person or Authorized Service Center.
Symptom Possible Cause(s) Corrective Action
Air leaking at trigger valve area.
Air leaking between housing and nose.
Air leaking between housing and cap.
Tool skips driving fastener 1. Worn bumper 1. Replace bumper
Tool runs slow or has loss of power
Fasteners are jammed in tool 1. Guide on driver is worn 1. Replace guide
O-Rings in trigger valve housing are
Replace o-rings
damaged
1. Loose screws in housing 1. Tighten screws
2. Damaged O-Rings 2. Replace o-rings
3. Damage to bumper 3. Replace bumper
1. Loose screws 1. Tighten screws
2. Damaged seal 2. Replace seal
2. Dirt in nose piece 2. Clean drive channel
3. Dirt or damage prevent fasteners or
3. Clean magazine
pusher from moving freely in magazine
4. Damaged pusher spring 4. Replace spring
5. Inadequate air flow to tool 5. Check fitting, hose, or compressor
6. Worn O-Ring on piston or lack of
6. Replace and lubricate o-rings
lubrication
7. Damaged O-Ring on trigger valve 7. Replace o-rings
8. Air leaks 8. Tighten screws and fittings
9. Cap seal leaking 9. Replace seal
1. Tool not lubricated sufficiently 1. Lubricate nailer
2. Broken spring in cylinder cap 2. Replace spring
3. Exhaust port in cap is blocked 3. Replace damaged internal parts
2. Fasteners are not correct size 2. Use only recommended fasteners
3. Fasteners are bent 3. Replace with undamaged fasteners
4. Magazine or nose screws are loose 4. Tighten screws
5. Driver is damaged 5. Replace driver
9
www.chpower.com
Operating Instructions SB660000
Limited Warranty
1. DURATION: From the date of purchase by the original purchaser as follows: One (1) Year.
2. WHO GIVES THIS WARRANTY (WARRANTOR): Campbell Hausfeld / Scott Fetzer Company, 100 Production Drive, Harrison, Ohio, 45030, Telephone: (800) 543-6400.
3. WHO RECEIVES THIS WARRANTY (PURCHASER): The original purchaser (other than for purposes of resale) of the Campbell Hausfeld product.
4. WHAT PRODUCTS ARE COVERED BY THIS WARRANTY: This Campbell Hausfeld nailer or stapler.
5. WHAT IS COVERED UNDER THIS WARRANTY: Substantial defects in material and workmanship which occur within the duration of the warranty period with the exceptions below.
6. WHAT IS NOT COVERED UNDER THIS WARRANTY:
A. Implied warranties, including those of merchantability and FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED FROM
THE DATE OF ORIGINAL PURCHASE AS STATED IN THE DURATION. If this product is used for commercial, industrial or rental purposes, the warranty will apply for ninety (90) days from the date of purchase. Some States do not allow limitation on how long an implied warranty lasts, so the above limitations may not apply to you.
B. ANY INCIDENTAL, INDIRECT, OR CONSEQUENTIAL LOSS, DAMAGE, OR EXPENSE THAT MAY RESULT FROM ANY
DEFECT, FAILURE, OR MALFUNCTION OF THE CAMPBELL HAUSFELD PRODUCT. Some States do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
C. Any failure that results from an accident, purchaser’s abuse, neglect or failure to operate products in accordance
with instructions provided in the owner’s manual(s) supplied with product. Accident, purchaser’s abuse, neglect or failure to operate products in accordance with instructions shall also include the removal or alteration of any safety
devices. If such safety devices are removed or altered, this warranty is void. D. Normal adjustments which are explained in the owner’s manual(s) provided with the product. E. Items or service that are normally required to maintain the product, e.g. o-rings, springs, bumpers, debris shield,
driver blades, gaskets, packings or seals, lubricants, or any other expendable part not specifically listed. These items
will only be covered for ninety (90) days from date of original purchase. Underlined items are warranted for defects
in material and workmanship only.
7. RESPONSIBILITIES OF WARRANTOR UNDER THIS WARRANTY: Repair or replace, at Warrantor’s option, products or components which are defective, have malfunctioned and/or failed to conform within the duration of the specific warranty period.
8. RESPONSIBILITIES OF PURCHASER UNDER THIS WARRANTY:
A. Provide dated proof of purchase and maintenance records. B. Call Campbell Hausfeld (800) 543-6400 to obtain your warranty service options. Freight costs must be borne by the
purchaser.
C. Use reasonable care in the operation and maintenance of the products as described in the owner’s manual(s).
9. WHEN WARRANTOR WILL PERFORM REPAIR OR REPLACEMENT UNDER THIS WARRANTY: Repair or replacement will be scheduled and serviced according to the normal work flow at the servicing location, and depending on the availability of replacement parts.
This Limited Warranty applies in the United States, Canada and Mexico only and gives you specific legal rights. You may also have other rights which vary from state to state or country to country.
www.chpower.com
10
Loading...
+ 22 hidden pages