This operating instructions manual has all the information you
need for quick setup and safe operation. Please read this
manual before you start setup.
1.2 Target group
This operating instructions manual is directed to trained,
qualified personnel. The contents of this manual should be
made available to these personnel and put into practice by
them.
1.3 Symbolism used
Information, tip, note
This symbol indicates helpful additional information.
Caution: If this warning is ignored, faults or
malfunctions can result.
Warning: If this warning is ignored, injury to persons and/or
serious damage to the instrument can result.
Danger: If this warning is ignored, serious injury to persons
and/or destruction of the instrument can result.
Ex applications
This symbol indicates special instructions for Ex applications.
lList
The dot set in front indicates a list with no implied sequence.
àAction
This arrow indicates a single action.
1Sequence
Numbers set in front indicate successive steps in a procedure.
All operations described in this operating instructions manual
must be carried out only by trained specialist personnel
authorised by the operator. For safety and warranty reasons,
any internal work on the instruments must be carried out only
by personnel authorised by the manufacturer.
2.2 Appropriate use
ARV-LS8112.1 is used for for infinite locking with tube
extension.
Detailed information on the application range of ARVLS8112.1 is available in chapter "
2.3 Warning about misuse
Inappropriate or incorrect use of the instrument can give rise to
application-specific hazards, e.g. vessel overfill or damage to
system components through incorrect mounting or adjustment.
2.4 General safety instructions
ARV-LS8112.1 is a high-tech instrument requiring the strict
observance of standard regulations and guidelines. The user
must take note of the safety instructions in this operating
instructions manual, the country-specific installation standards
(e.g. the VDE regulations in Germany) as well as all prevailing
safety regulations and accident prevention rules.
The lock fitting ARV-LS8112.1 is a threaded fitting and can be
used together with a level sensor in tube version (LEVELSWITCH 8112). Depending on the version, the tube extension
of the sensor must have a diameter of 21.3 mm (0.84 in):
ARV-LS8112.1 cannot be used in coated tube extensions.
The wetted parts of ARV-LS8112.1 are made of steel (316L).
The ARV-LS8112.1 must only be used in unpressurized
vessels.
With the lock fittings, sensors with tube extension can be fixed
infinitely.
The terminal screws protect the tube against sliding through.
The following versions are available:
l ø 21.3 mm - G1 A or 1 NPT (SW 41)
l ø 21.3 mm - G1½ A or 1½ NPT (SW 60)
Your instrument was protected by packaging during transport.
Its capacity to handle normal loads during transport is assuredby a test according to DIN EN 24180.
The packaging of standard instruments consists of environ-
ment-friendly, recyclable cardboard. For special versions, PE
foam or PE foil is also used. Dispose of the packaging material
via specialised recycling companies.
l Storage and transport temperature see "Supplement -
Technical data - Ambient conditions"
l Relative humidity 20 … 85 %
Mounting
4 Mounting
4.1 Mounting sequence
The numbers in brackets refer to the figures on the following
pages.
Note chapter "Mounting" and carry out the described steps in
reverse order.
If you proceed as follows, it is not necessary to readjust the
switching point and the lock fittings must not be dismounted
completely.
1 Switch off power supply of the sensor
2 Remove all connection cables
3 Loosen lock fitting with a screwdriver
4 Remove the sensor together with the lock fitting
6.2 Disposal
ARV-LS8112.1 consists of materials which can be recycled by
specialised recycling companies. Mark the instrument as
scrap and dispose it according to the national, legal
regulations.
Materials: see chapter "Technical data"