Burkert 8112 User Manual [en, de, fr]

Operating Instructions
Lock tting ARV­LS8112.1
for LEVEL SWITCH 8112
- unpressurised operation

Contents

Contents
1.1 Function .............................
1.2 Target group ..........................
1.3 Symbolism used .......................
2 For your safety
2.1 Authorised personnel....................
2.2 Appropriate use........................
2.3 Warning about misuse ...................
3 Product description
3.1 Conguration..........................
3.2 Principle of operation....................
3.3 Storage and transport ...................
4 Mounting
4.1 Mounting sequence .....................
5 Maintenance and fault rectication
5.1 Maintenance ..........................
5.2 Instrument repair .......................
6 Dismounting
6.1 Dismounting steps ......................
6.2 Disposal .............................
3 3 3
4 4 4
5 5 5
6
7 7
8 8
7 Supplement
7.1 Technical data.........................
7.2 Dimensions...........................
2 Lock tting ARV-LS8112.1 --unpressurised operation
10
9
32053-EN-070220
About this document

1 About this document

1.1 Function

This operating instructions manual has all the information you need for quick setup and safe operation. Please read this manual before you start setup.

1.2 Target group

This operating instructions manual is directed to trained, qualied personnel. The contents of this manual should be made available to these personnel and put into practice by them.

1.3 Symbolism used

Information, tip, note
This symbol indicates helpful additional information.
Caution: If this warning is ignored, faults or malfunctions can result. Warning: If this warning is ignored, injury to persons and/or serious damage to the instrument can result. Danger: If this warning is ignored, serious injury to persons and/or destruction of the instrument can result.
Ex applications
This symbol indicates special instructions for Ex applications.
l List
The dot set in front indicates a list with no implied sequence.
à Action
This arrow indicates a single action.
1 Sequence
Numbers set in front indicate successive steps in a procedure.
32053-EN-070220
Lock tting ARV-LS8112.1 --unpressurised operation 3
For your safety

2 For your safety

2.1 Authorised personnel

All operations described in this operating instructions manual must be carried out only by trained specialist personnel authorised by the operator. For safety and warranty reasons, any internal work on the instruments must be carried out only by personnel authorised by the manufacturer.

2.2 Appropriate use

ARV-LS8112.1 is used for for innite locking with tube extension.
Detailed information on the application range of ARV­LS8112.1 is available in chapter "

2.3 Warning about misuse

Inappropriate or incorrect use of the instrument can give rise to application-specic hazards, e.g. vessel overll or damage to system components through incorrect mounting or adjustment.

2.4 General safety instructions

ARV-LS8112.1 is a high-tech instrument requiring the strict observance of standard regulations and guidelines. The user must take note of the safety instructions in this operating instructions manual, the country-specic installation standards (e.g. the VDE regulations in Germany) as well as all prevailing safety regulations and accident prevention rules.
Product description".
4 Lock tting ARV-LS8112.1 --unpressurised operation
32053-EN-070220

3 Product description

3.1 Conguration
Product description
Scope of delivery
Area of application
Functional principle
The scope of delivery encompasses:
l Lock tting ARV-LS8112.1 for LEVEL SWITCH 8112
vibrating level switch
l Documentation
- this operating instructions manual

3.2 Principle of operation

The lock tting ARV-LS8112.1 is a threaded tting and can be used together with a level sensor in tube version (LEVEL SWITCH 8112). Depending on the version, the tube extension of the sensor must have a diameter of 21.3 mm (0.84 in):
ARV-LS8112.1 cannot be used in coated tube extensions.
The wetted parts of ARV-LS8112.1 are made of steel (316L).
The ARV-LS8112.1 must only be used in unpressurized
vessels.
With the lock ttings, sensors with tube extension can be xed innitely.
The terminal screws protect the tube against sliding through.
The following versions are available:
l ø 21.3 mm - G1 A or 1 NPT (SW 41) l ø 21.3 mm - G1½ A or 1½ NPT (SW 60)

3.3 Storage and transport

Packaging
Storage and transport tem-
perature
32053-EN-070220
Lock tting ARV-LS8112.1 --unpressurised operation 5
Your instrument was protected by packaging during transport. Its capacity to handle normal loads during transport is assured by a test according to DIN EN 24180.
The packaging of standard instruments consists of environ-
ment-friendly, recyclable cardboard. For special versions, PE foam or PE foil is also used. Dispose of the packaging material via specialised recycling companies.
l Storage and transport temperature see "Supplement -
Technical data - Ambient conditions"
l Relative humidity 20 85 %
Mounting

4 Mounting

4.1 Mounting sequence

The numbers in brackets refer to the gures on the following pages.
1
2
Fig. 1: Lock tting ARV-LS8112.1 - unpressurised 1 Lock tting 2 Terminal screws (3 pcs.)
1 Screw the lock tting (1) with a resistant seal ring into the
thread of your vessel and tighten the lock tting (1) on the hexagon
2 Clean the connection tube of the sensor and the lock tting
carefully and remove grease, oil and dirt. Insert the sensor into the lock tting. Slide the tube into the requested position and hold it
3 Make sure that the sensor is in the correct position (height).
The height adjustment of the sensor determines also the
switching point
4 Tighten the terminal screws (2) with a torque of 4 ±1 Nm
(3 ±0.7 lbf ft)
The terminal screws (2) press lightly into the tube and x the tube of the sensor in this position.
6 Lock tting ARV-LS8112.1 --unpressurised operation
32053-EN-070220
Maintenance and fault rectication
5 Maintenance and fault rectication

5.1 Maintenance

When used as directed in normal operation, ARV-LS8112.1 is completely maintenance free.

5.2 Instrument repair

If a repair is necessary, please proceed as follows:
You can download a return form from our homepage.
By doing this you help us carry out the repair quickly and
without having to call for needed information.
l Print and ll out one form per instrument l Clean the instrument and pack it damage-proof l Attach the lled in form and if necessary, a safety data
sheet to the instrument
l Send the instrument to the address of the agency serving
you, in Germany directly to the headquarters
32053-EN-070220
Lock tting ARV-LS8112.1 --unpressurised operation 7
Dismounting

6 Dismounting

6.1 Dismounting steps

Note chapter "Mounting" and carry out the described steps in reverse order.
If you proceed as follows, it is not necessary to readjust the switching point and the lock ttings must not be dismounted completely.
1 Switch opower supply of the sensor 2 Remove all connection cables 3 Loosen lock tting with a screwdriver 4 Remove the sensor together with the lock tting

6.2 Disposal

ARV-LS8112.1 consists of materials which can be recycled by specialised recycling companies. Mark the instrument as scrap and dispose it according to the national, legal regulations.
Materials: see chapter "Technical data"
If you cannot dispose of the instrument properly, please
contact us about disposal methods or return.
8 Lock tting ARV-LS8112.1 --unpressurised operation
32053-EN-070220

7 Supplement

7.1 Technical data

General data
Material 316L corresponds to 1.4404 or 1.4435 Process tting
- G1 A or 1 NPT
- G1½ A or 1½ NPT
Tube diameter of the sensor ø 21.3 mm (0.84 in) Materials
- Lock tting 316L
- Process seal Klingersil C-4400
Terminal screws Pin with hexagon DIN 913 M5x8 Torque
- Terminal screws (M5) 4 ±1 Nm (3 ±0.7 lbf ft)
Process conditions
Operating pressure unpressurized Product temperature -50 +250 °C (-58 +482 °F)
1)
Supplement
Approvals
The lock ttings have no own approvals
1)
not with thread NPT
32053-EN-070220
Lock tting ARV-LS8112.1 --unpressurised operation 9
Supplement

7.2 Dimensions

Lock tting ARV-LS8112.1 for LEVEL SWITCH 8112
ø 21,3mm
27
(
/32")
")
8
/
3
35mm (1
20mm
25
")
32
/ (
41mm
(1 39/64")
G1A/ 1 NPT
60mm
(2 23/64")
G1½A/ 1½ NPT
Fig. 2: Lock tting ARV-LS8112.1 unpressurized for LEVEL SWITCH 8112
10 Lock tting ARV-LS8112.1 --unpressurised operation
32053-EN-070220
Supplement
32053-EN-070220
Lock tting ARV-LS8112.1 --unpressurised operation 11
Loading...