Brocade RFS6000 Installation Guide

Page 1
®
Brocade Mobility RFS7000 Controller
Installation Guide
53-1001574-03 Rev B
Page 2
Copyright © 2009 - 2011 Brocade Communications Systems, Inc. All Rights Reserved.
Brocade, the B-wing symbol, BigIron, DCX, Fabric OS, FastIron, IronPoint, IronShield, IronView, IronWare, JetCore, NetIron, SecureIron, ServerIron, StorageX, and TurboIron are registered trademarks, and DCFM, Extraordinary Networks, and SAN Health are trademarks of Brocade Communications Systems, Inc., in the United States and/or in other countries. All other brands, products, or service names are or may be trademarks or service marks of, and are used to identify, products or services of their respective owners.
Notice: This document is for informational purposes only and does not set forth any warranty, expressed or implied, concerning any equipment, equipment feature, or service offered or to be offered by Brocade. Brocade reserves the right to make changes to this document at any time, without notice, and assumes no responsibility for its use. This informational document describes features that may not be currently available. Contact a Brocade sales office for information on feature and product availability. Export of technical data contained in this document may require an export license from the United States government.
The authors and Brocade Communications Systems, Inc. shall have no liability or responsibility to any person or entity with respect to any loss, cost, liability, or damages arising from the information contained in this book or the computer programs that accompany it.
Brocade Communications Systems, Incorporated
Corporate and Latin American Headquarters Brocade Communications Systems, Inc. 130 Holger Way San Jose, CA 95134 Tel: 1-408-333-8000 Fax: 1-408-333-8101 E-mail: info@brocade.com
European Headquarters Brocade Communications Switzerland Sàrl Centre Swissair Tour B - 4ème étage 29, Route de l'Aéroport Case Postale 105 CH-1215 Genève 15 Switzerland Tel: +41 22 799 5640 Fax: +41 22 799 5641 E-mail: emea-info@brocade.com
Asia-Pacific Headquarters Brocade Communications Systems China HK, Ltd. No. 1 Guanghua Road Chao Yang District Units 2718 and 2818 Beijing 100020, China Tel: +8610 6588 8888 Fax: +8610 6588 9999 E-mail: china-info@brocade.com
Asia-Pacific Headquarters Brocade Communications Systems Co., Ltd. (Shenzhen WFOE) Citic Plaza No. 233 Tian He Road North Unit 1308 – 13th Floor Guangzhou, China Tel: +8620 3891 2000 Fax: +8620 3891 2111 E-mail: china-info@brocade.com
Document History
Title Publication number Summary of changes Date
Brocade Mobility RFS7000 Controller Installation Guide
Brocade Mobility RFS7000 Controller Installation Guide
Brocade Mobility RFS7000 Controller Installation Guide
53-1001574-03 Updated WEEE icon and Korean
53-1001574-02 Updated company address Dec 2010
53-1001574-01 New document Dec 2009
Class A statement
May 2011
Page 3
1 Introduction 1
Package contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Site preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
2 Specifications 5
Physical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Power cord specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Power protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3 LED Codes 7
System status LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Start up / post (primary system or redundant system) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Switch status (primary system) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Switch status (redundant system) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Fan LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Temperature status LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
RJ-45 Gigabit Ethernet LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
RJ-45 port speed LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
RJ-45 port status LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
SFP Gigabit Ethernet LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
SFP port speed LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
SFP port status LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Out of band management port LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Out of band management port speed LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Out of band management port status LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
4 Hardware Setup 15
Cabling information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Gigabit Ethernet on the Mobility RFS7000 Controller . . . . . . . . . . . . . . . . . . . . . . . .16
Installing Gigabit Ethernet SFPs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Connecting USB devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Installing a compact flash card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Rack mount instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Mobility RFS7000 Controller console port setup . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Brocade Mobility RFS7000 Controller Installation Guide iii 53-1001574-03
Page 4
Supplying power to the Mobility RFS7000 Controller . . . . . . . . . . . . . . . . . . . . . . . . 23
Verifying the installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
5 Regulatory Information 25
Country selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Laser Devices - Gigabit Ethernet SFP option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Radio frequency interference requirements - FCC . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Radio frequency interference requirements - Canada . . . . . . . . . . . . . . . . . . . . . . . 26
CE marking and European Economic Area (EEA) . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Statement of compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Japan (VCCI) - voluntary control council for interference . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Class A ITE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Korea MIC/KCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Japan power cord statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Chinese CCC statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Waste Electrical and Electronic Equipment (WEEE) . . . . . . . . . . . . . . . . . . . . . . . . . 28
iv Brocade Mobility RFS7000 Controller Installation Guide
53-1001574-03
Page 5

About This Document

In this chapter

Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v
Supported hardware and software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v
Document conventions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v
Contacting Brocade . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vi
Warranty coverage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii

Audience

This document is designed for system administrators with a working knowledge of Layer 2 and Layer 3 switching and routing.
If you are using a Brocade Layer 3 Switch, you should be familiar with the following protocols if applicable to your network – IP, RIP, OSPF, BGP, ISIS, IGMP, PIM, DVMRP, and VRRP.

Supported hardware and software

The following hardware platforms are supported by this release of this guide:
Brocade Mobility RFS7000 Controller

Document conventions

This section describes text formatting conventions and important notice formats used in this document.
Brocade Mobility RFS7000 Controller Installation Guide v 53-1001574-03
Page 6
Notes, cautions, and warnings
NOTE
CAUTION
DANGER
The following notices and statements are used in this manual. They are listed below in order of increasing severity of potential hazards.
A note provides a tip, guidance or advice, emphasizes important information, or provides a reference to related information.
A Caution statement alerts you to situations that can be potentially hazardous to you or cause damage to hardware, firmware, software, or data.
A Danger statement indicates conditions or situations that can be potentially lethal or extremely hazardous to you. Safety labels are also attached directly to products to warn of these conditions or situations.

Contacting Brocade

When contacting Brocade support, please provide the following information:
Serial number of the unit
Model number or product name
Software version
Customer Support Web Site
Brocade Support Central Web site, located at www.brocade.com/support provides information and online assistance including developer tools, software downloads, product manuals and online repair requests.
vi Brocade Mobility RFS7000 Controller Installation Guide
53-1001574-03
Page 7
Downloads
http://www.brocade.com/support/
Manuals
http://www.brocade.com/support/
Because quality is our first concern at Brocade, we have made every effort to ensure the accuracy and completeness of this document. However, if you find an error or an omission, or you think that a topic needs further development, we want to hear from you. Forward your feedback to: documentation@brocade.com
Provide the title and version number and as much detail as possible about your comment, including the topic heading and page number and your suggestions for improvement.
Email access and telephone access
Go to http://www.brocade.com/services-support/index.page for email and telephone contact information.

Warranty coverage

.
Contact Brocade Communications Systems using any of the methods listed above for information about the standard and extended warranties.
Brocade Mobility RFS7000 Controller Installation Guide vii 53-1001574-03
Page 8
viii Brocade Mobility RFS7000 Controller Installation Guide
53-1001574-03
Page 9
Chapter

Introduction

In this chapter
Package contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Site preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
The Brocade Mobility RFS7000 Controller is a high-performance member of Brocade’s Wireless Controller family. The Mobility RFS7000 Controller provides centralized Wireless LAN (WLAN) configuration and management by coalescing a network “intelligence” previously spread across physically distributed access points. By replacing access points with simpler access ports (or “thin” access points), the Mobility RFS7000 Controller becomes a WLAN’s single point of contact, thus reducing wireless networking complexity by moving management out of the ceiling and into the wiring closet. In addition, through the use of patented Virtual AP architecture, the Mobility RFS7000 Controller lets you create multiple WLANs without changing or adding to the existing wired network infrastructure.
This document is written for the network device installer.
1

Package contents

Inspect the package contents and report any missing or damaged items to your sales representative. The package should contain the following:
Mobility RFS7000 Controller with Rack Brackets installed
Console Cable
Brocade Mobility RFS7000 Controller Installation Guide (this document)
China RoHS compliance document
Brocade Mobility RFS7000 Controller Installation Guide 1 53-1001574-03
Page 10

Warnings

CAUTION
1
Warnings
Read all installation instructions and site survey reports, and verify correct
Remove jewelry and watches before installing this equipment.
Install the equipment in a rack with adequate dimensions and weight
Verify the rack is anchored and cannot tip over or break away from its
Verify the unit is grounded before connecting it to the power source.
Verify any device connected to this unit is properly wired and grounded.
Connect all power cords to a properly wired and grounded electrical circuit.
Verify the electrical circuits have appropriate overload protection.
Attach only approved power cords to the device.
Brocade strongly recommends the use of an Uninterruptible Power Supply
Verify that the power connector and socket are accessible at all times during
Do not work with power circuits in dimly lit spaces.
Do not install this equipment or work with its power circuits during
Verify there is adequate ventilation around the device, and ambient
Before installing or handling the Mobility RFS7000 Controller, have on hand an
equipment installation before connecting the system to its power source.
allowances.
mountings.
(UPS) that supports the IP-RFS7000 power rating. Not using a UPS can result in data loss or equipment damage due to a power surge or power failure.
the operation of the equipment.
thunderstorms or other weather conditions that could cause a power surge.
temperatures meet equipment operation specifications.
ESD wrist strap or other ESD voltage limiting device.
For safety reasons, the ESD wrist strap should contain a 1 meg ohm series resistor.
2 Brocade Mobility RFS7000 Controller Installation Guide
53-1001574-03
Page 11

Site preparation

Site preparation
Consult your site survey and network analysis reports to determine specific
equipment placement, port capacity, power drops, and so on.
Assign installation responsibility to the appropriate personnel.
Identify where all installed components are located.
Verify appropriate rack mounting requirements.
Provide a sufficient number of power drops for your equipment.
Ensure adequate, dust-free ventilation to all installed equipment.
Identify and prepare Ethernet and console port connections.
Verify that cable lengths are within the maximum allowable distances for
optimal signal transmission.
Verify that the Mobility RFS7000 Controller is powered through an
Uninterruptible Power Supply (UPS).
1
Brocade Mobility RFS7000 Controller Installation Guide 3 53-1001574-03
Page 12
Site preparation
1
4 Brocade Mobility RFS7000 Controller Installation Guide
53-1001574-03
Page 13
Chapter

Specifications

In this chapter
Physical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Power cord specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Physical specifications

Width
Height
Depth
Weight
Operating temperature
Operating humidity
Operating altitude
2
440mm (17.32 in)
44.45mm (1.75 in)
390.8mm (15.38 in)
6.12 Kg (13.5 lbs) 0°C - 40°C
5% - 85% RH, non-condensing
3 km (10000 ft)

Power cord specifications

A power cord is not supplied with the switch. Use only a correctly rated power cord certified (as appropriate) for the country of operation

Power protection

If possible, use a circuit dedicated to data processing equipment. Commercial
electrical contractors are familiar with wiring for data processing equipment and can help with the load balancing of these circuits.
Install surge protection. Be sure to use a surge protection device between the
electricity source and the Mobility RFS7000 Controller.
Brocade Mobility RFS7000 Controller Installation Guide 5 53-1001574-03
.
Page 14
Power cord specifications
2
Install an Uninterruptible Power Supply (UPS). A UPS provides continuous
power during a power outage. Some UPS devices have integral surge protection. UPS equipment requires periodic maintenance to ensure reliability. A UPS of the proper capacity for the data processing equipment must be purchased.
6 Brocade Mobility RFS7000 Controller Installation Guide
53-1001574-03
Page 15
Chapter
System Status 1
Fan status
Temperature status
System Status 2

LED Codes

In this chapter
System status LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
RJ-45 Gigabit Ethernet LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
SFP Gigabit Ethernet LEDs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Out of band management port LEDs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
The Mobility RFS7000 Controller has four vertically-stacked LEDs on its front panel. Each of the switch’s Gigabit Ethernet ports have two status LEDs. These LEDs display two colors (green & amber), and three lit states (solid, blinking, and off). The following tables decode the combinations of LED colors and states for the System Status LEDs and the Gigabit Ethernet LEDs.

System status LEDs

3
Brocade Mobility RFS7000 Controller Installation Guide 7 53-1001574-03
Page 16
System status LEDs
NOTE
3

Start up / post (primary system or redundant system)

System status 1 LED System status 2 LED Event
Off Off Power off
Green blinking Green Blinking Power On Self Test (POST) running
Green solid Green Blinking POST succeeded (Operating System
Green solid Off POST succeeded (Normal Operation)
Amber blinking Off POST Failure
Alternating green blinking & amber blinking
During switch start up, the Temperature status LED will be lit Solid Amber. This is normal behavior and does not indicate an error. At the completion of start up the Temperature Status LED will switch to Solid Green.
Alternating Green Blinking & Amber Blinking
Loading)
Boot Up Error: Device has an invalid checksum

Switch status (primary system)

System status 1 LED System status 2 LED Event
Off Off Power off
Green solid Off No Redundancy Feature Enabled
Green solid Green solid Redundancy Feature Enabled
Actively Adopting Access Points
Green solid Amber blinking No License to adopt Access Points or No
Country Code configured on the switch.
8 Brocade Mobility RFS7000 Controller Installation Guide
53-1001574-03
Page 17
System status LEDs

Switch status (redundant system)

System status 1 LED System status 2 LED Event
Off Off Power off
Green Solid Off No Redundancy Feature Enabled
Green Blinking Green Solid Redundant System failed over and
adopting ports
Green Blinking Alternating Green Blinking
& Amber Blinking
Green Solid Amber Blinking No License to adopt Access Points
Redundant System not failed over.
or No Country Code configured on the switch.

Fan LED

Fan LED Event
Off System Off / POST Start
Green Blinking POST in Process
Green Solid All System Fans Normal Operation
Amber Solid Redundant Cooling Failure
System Operational
Amber Blinking System Cooling Failure
System will be held in reset until the issue is resolved
3
Brocade Mobility RFS7000 Controller Installation Guide 9 53-1001574-03
Page 18

RJ-45 Gigabit Ethernet LEDs

sym_006
Port
speed
Port
status
Port
speed
Port
status
3

Temperature status LED

Temperature LED Event
Off System Off
Green Solid Ambient Inlet Temperature is within specified
operating limit
Amber Solid Ambient Inlet Temperature is near the maximum
operating temperature
During switch start up this LED will be lit Solid Amber. This is normal behavior and does not indicate an error.
Amber Blinking Ambient Inlet Temperature is above the
maximum specified operating temperature
System will be held in reset until the issue is resolved
RJ-45 Gigabit Ethernet LEDs
10 Brocade Mobility RFS7000 Controller Installation Guide
53-1001574-03
Page 19

SFP Gigabit Ethernet LEDs

sym_
Port
speed
Port
status
Upper
Port
Lower
Port

RJ-45 port speed LED

Port speed LED Event
Off 10 Mbps
Green Solid 100 Mbps
Green Blinking 1000 Mbps
Amber Blinking Port Fault

RJ-45 port status LED

Port status LED Event
Off No Link or Administratively shut down
Green Solid Link present
Green Blinking Activity: Transmit and Receive
Amber Blinking Link Fault
3
SFP Gigabit Ethernet LEDs
Brocade Mobility RFS7000 Controller Installation Guide 11 53-1001574-03
Page 20

Out of band management port LEDs

sym_0
Port
speed
Port
status
3

SFP port speed LED

Port speed LED Event
Green Blinking 1000 Mbps
Amber Blinking Module or Tx/Rx Fault Loss

SFP port status LED

Port status LED Event
Off No Link or Administratively shut down
Green Solid Link present / Operational
Amber Blinking Module or Tx/Rx Fault Loss
Out of band management port LEDs
12 Brocade Mobility RFS7000 Controller Installation Guide
53-1001574-03
Page 21
Out of band management port LEDs

Out of band management port speed LED

Port speed LED Event
Off 10 Mbps
Green Solid 100 Mbps
Amber Blinking Port Fault

Out of band management port status LED

Port status LED Event
Off No Link
Green Solid Link present
Green Blinking Activity: Transmit and Receive
Amber Blinking Link Fault
3
Brocade Mobility RFS7000 Controller Installation Guide 13 53-1001574-03
Page 22
Out of band management port LEDs
3
14 Brocade Mobility RFS7000 Controller Installation Guide
53-1001574-03
Page 23
Chapter
sym_023
Gigabit Ethernet
SFPs
Console
connector
Out-of-band
management
port
(FE Port)
Compact
Flash
USB
ports
Gigabit Ethernet
RJ45s

Hardware Setup

This chapter contains the following sections:
Cabling information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Gigabit Ethernet on the Mobility RFS7000 Controller . . . . . . . . . . . . . . . . . 16
Connecting USB devices. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Installing a compact flash card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Rack mount instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Mobility RFS7000 Controller console port setup . . . . . . . . . . . . . . . . . . . . 22
Supplying power to the Mobility RFS7000 Controller . . . . . . . . . . . . . . . . 23
Verifying the installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
4
Brocade Mobility RFS7000 Controller Installation Guide 15 53-1001574-03
Page 24

Cabling information

sym_005
Out-of-Band
Management
Gigabit
SFP
Port 1
Gigabit
Ethernet
Port 1
Console
Compact Flash
USB 1 USB 2
Gigabit
Ethernet
Port 2
Gigabit
SFP
Port 2
Gigabit
SFP
Port 3
Gigabit
SFP
Port 4
Gigabit
Ethernet
Port 3
Gigabit
Ethernet
Port 4
4
Cabling information
The Mobility RFS7000 Controller has four RJ-45 Gigabit Ethernet ports, four Gigabit SFP (fiber) ports, one Out-of-band management port and one Console connector. The diagram shows each of those ports and the cables or devices attached to them. The sections that follow describe detailed connection and cabling information for each port. For software configuration, please see the Mobility RFS7000 Controller System Reference Guide available from the Brocade website.

Gigabit Ethernet on the Mobility RFS7000 Controller

The Mobility RFS7000 Controller has four RJ-45 Gigabit Ethernet ports and four Gigabit SFP (fiber optic) ports. Using the RJ-45 ports requires connecting a Category-6 Ethernet cable to the port. To use the Gigabit SFP ports, first install the SFP modules (Part No. FIBER-3000-1S-WWR).
16 Brocade Mobility RFS7000 Controller Installation Guide
53-1001574-03
Page 25
Gigabit Ethernet on the Mobility RFS7000 Controller
Gigabit Ethernet
RJ45s
Gigabit Ethernet
SFPs
Open bail to insert or remove
SFP transceiver

Installing Gigabit Ethernet SFPs

4
1. Open the bail on the transceiver.
Brocade Mobility RFS7000 Controller Installation Guide 17 53-1001574-03
Page 26
Gigabit Ethernet on the Mobility RFS7000 Controller
4
2. Insert each of the SFP transceivers into the corresponding ports on the switch.
3. Once the SFP transceivers are properly seated in their ports, close the bails to lock the transceivers in place.
4. Insert the fiber optic cables into the installed transceivers.
18 Brocade Mobility RFS7000 Controller Installation Guide
53-1001574-03
Page 27

Connecting USB devices

USB
ports
Connecting USB devices
4
The Mobility RFS7000 Controller contains two USB ports for connecting USB flash storage devices to the switch. The switch can use the USB flash storage devices for file transfers and firmware updates. Follow the setup instructions below to connect the devices to the switch and then access those devices through the Web UI or Command Line Interface.
1. Connect the USB flash drive to either of the USB ports.
2. Wait a few seconds for the drive to be recognized by the switch.
3. Follow the instructions in the Mobility RFS7000 Controller System Reference
Guide or Mobility RFS7000 Controller CLI Reference for more information on accessing USB storage devices from the switch for file transfers or firmware updates.
Brocade Mobility RFS7000 Controller Installation Guide 19 53-1001574-03
Page 28

Installing a compact flash card

NOTE
Compact
Flash slot
Compact Flash
4
The switch supports USB flash devices formatted with FAT or VFAT (FAT32) filesystems only. If your flash storage device is formatted with another filesystem you will need to format
Installing a compact flash card
The Mobility RFS7000 Controller contains a Compact Flash slot for file transfers, firmware updates and use by Brocade service technicians. Follow the setup instructions below to connect a Compact Flash Card to the switch and then access that card through the Web UI.
1. To use a Compact Flash card with the Mobility RFS7000 Controller insert the
2. Once the Compact Flash card has been inserted, follow the instructions in the
20 Brocade Mobility RFS7000 Controller Installation Guide
card into the Compact Flash slot.
Mobility RFS7000 Controller System Reference Guide or Mobility RFS7000 Controller CLI reference to use the Compact Flash card for file transfers or firmware updates.
53-1001574-03
Page 29

Rack mount instructions

Rack mount instructions
4
To install the Mobility RFS7000 Controller in a rack:
1. The rack mounting brackets are installed at the factory. No additional steps are
needed.
2. Attach the brackets to the rack using screws appropriate for your rack’s
mounting holes.
Brocade Mobility RFS7000 Controller Installation Guide 21 53-1001574-03
Page 30

Mobility RFS7000 Controller console port setup

4
Mobility RFS7000 Controller console port setup
To add the Mobility RFS7000 Controller to the network and prepare it for initial configuration:
1. Using the supplied console cable (pictured below), connect the Mobility RFS7000 Controller serial port to an RS-232 (DB-9) serial port on a separate computer (the “configuration computer”).
2. On the configuration computer, configure a terminal emulation application (such as HyperTerminal) as follows:
Terminal type
Port
Terminal settings
22 Brocade Mobility RFS7000 Controller Installation Guide
VT-100
COM port
19200bps transfer rate 8 data bits no parity 1 stop bit no flow control no hardware compression
53-1001574-03
Page 31

Supplying power to the Mobility RFS7000 Controller

CAUTION
sym_0
Rack mount
bracket
AC inlet
Supplying power to the Mobility RFS7000 Controller
1. Plug an approved AC power cord into the power connector at the back of the
Mobility RFS7000 Controller.
4
2. Plug the cord into a standard AC outlet with a voltage range of 100 to 240 VAC.
An improper shutdown can render the Mobility RFS7000 Controller inoperable such that it could require service by Brocade Support. Do not remove AC power without first following the shutdown procedure. An abrupt loss of power can corrupt the information stored on the device.
Brocade Mobility RFS7000 Controller Installation Guide 23 53-1001574-03
Page 32

Verifying the installation

4
Verifying the installation
View the LEDs on the front panel of the Mobility RFS7000 Controller to ensure the device is functioning properly. The normal LED pattern follows this path:
During the Power On Self Test (POST), the System 1 and System 2 LEDs both
blink green.
If the POST test fails, the System 1 LED will blink amber. If the POST test
succeeds, the System 1 LED will be lit solid green.
As the software is initialized, the System 2 LED will blink green.
After the software has finished initializing, the System 1 LED will be lit solid
green and the bottom System 2 LED will be off. The Mobility RFS7000 Controller is ready to be configured, as described in the Mobility RFS7000 Controller System Reference Guide.
Other LED codes indicate the presence (or absence) of different standby states, or errors. A guide to the Mobility RFS7000 Controller LEDs codes is provided in “LED
Codes” on page 7.
24 Brocade Mobility RFS7000 Controller Installation Guide
53-1001574-03
Page 33
Chapter
!

Regulatory Information

In this chapter
Country selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Laser Devices - Gigabit Ethernet SFP option . . . . . . . . . . . . . . . . . . . . . . . 25
Radio frequency interference requirements - FCC . . . . . . . . . . . . . . . . . . . 26
Radio frequency interference requirements - Canada. . . . . . . . . . . . . . . . 26
CE marking and European Economic Area (EEA) . . . . . . . . . . . . . . . . . . . . . 27
Waste Electrical and Electronic Equipment (WEEE). . . . . . . . . . . . . . . . . . 28
This regulatory section applies to the Mobility RFS7000 Controller.
All Brocade devices are designed to be compliant with rules and regulations in locations they are sold and will be labeled as required.
Any changes or modifications to Brocade equipment, not expressly approved by Brocade, could void the user’s authority to operate the equipment.
5

Country selection

Select only the country in which you are using the device. Any other selection will make the operation of this device illegal.

Laser Devices - Gigabit Ethernet SFP option

Complies with 21CFR1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated July 26, 2001.
EN60825-1:1994+ A1:2002 +A2:2001
IEC60825-1:1993+A1:1997+A2:2001
The laser classification is marked on the device.
Brocade Mobility RFS7000 Controller Installation Guide 25 53-1001574-03
Page 34

Radio frequency interference requirements - FCC

CAUTION
5
Class 1 Laser devices are not considered to be hazardous when used for their intended purpose. The following statement is required to comply with US and international regulations:
This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Radio frequency interference requirements - FCC
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Radio frequency interference requirements - Canada

This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
26 Brocade Mobility RFS7000 Controller Installation Guide
53-1001574-03
Page 35

CE marking and European Economic Area (EEA)

この装置は、情報処理装置等電波障害自主規制協議会(VCCI)の基準に基づくクラスA 情報技術装置です。この装置を家庭環境で使用すると電波妨害を引き起こすことがありま す。この場合には使用者が適切な対策を講ずるよう要求されることがあります。
급 기기 ( 업무용 방송통신기기 ): 이 기기는 업무용 (A 급 ) 으로 전자파적합등록
한 기기이오니 판매자 또는 사용자는 이 점을 주의하시기 바라며 , 가정외의 지역
서 사용하는 것을 목적으로 합니다
CE marking and European Economic Area (EEA)

Statement of compliance

Brocade hereby declares that this device is in compliance with all the applicable Directives, 2004/108/EC, 2006/95/EC. A Declaration of Conformity may be obtained from http://www2symbol.com/doc/

Japan (VCCI) - voluntary control council for interference

5

Class A ITE

This is a Class A product based on the standard of the Voluntary Control Council for Interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio interference may occur, in which case, the user may be required to take corrective actions.

Korea

A 을 에
Class A device (Broadcasting Communication Device for Office Use): This device
Brocade Mobility RFS7000 Controller Installation Guide 27 53-1001574-03
obtained EMC registration for office use (Class A), and may be used in places other than home. Sellers and/or users need to take note of this.
.
Page 36

Waste Electrical and Electronic Equipment (WEEE)

5

Japan power cord statement

Chinese CCC statement

Waste Electrical and Electronic Equipment (WEEE)
For information on WEEE, please go to:
http://www.brocade.com/company/corporate-citizenship/product-recycling/Overv iew/index.page.
28 Brocade Mobility RFS7000 Controller Installation Guide
53-1001574-03
Page 37
Page 38
Page 39
Page 40
Loading...