Brocade RFS4000 Installation Guide

Brocade Mobility RFS4000 Controller
Installation Guide
Supporting software release 4.3.0.0 and later
®
53-1001933-02 Rev B
Copyright © 2011 Brocade Communications Systems, Inc. All Rights Reserved.
Notice: This document is for informational purposes only and does not set forth any warranty, expressed or implied, concerning any equipment, equipment feature, or service offered or to be offered by Brocade. Brocade reserves the right to make changes to this document at any time, without notice, and assumes no responsibility for its use. This informational document describes features that may not be currently available. Contact a Brocade sales office for information on feature and product availability. Export of technical data contained in this document may require an export license from the United States government.
The authors and Brocade Communications Systems, Inc. shall have no liability or responsibility to any person or entity with respect to any loss, cost, liability, or damages arising from the information contained in this book or the computer programs that accompany it.
Brocade Communications Systems, Incorporated
Corporate and Latin American Headquarters Brocade Communications Systems, Inc. 130 Holger Way San Jose, CA 95134 Tel: 1-408-333-8000 Fax: 1-408-333-8101 E-mail: info@brocade.com
European Headquarters Brocade Communications Switzerland Sàrl Centre Swissair Tour B - 4ème étage 29, Route de l'Aéroport Case Postale 105 CH-1215 Genève 15 Switzerland Tel: +41 22 799 5640 Fax: +41 22 799 5641 E-mail: emea-info@brocade.com
Asia-Pacific Headquarters Brocade Communications Systems China HK, Ltd. No. 1 Guanghua Road Chao Yang District Units 2718 and 2818 Beijing 100020, China Tel: +8610 6588 8888 Fax: +8610 6588 9999 E-mail: china-info@brocade.com
Asia-Pacific Headquarters Brocade Communications Systems Co., Ltd. (Shenzhen WFOE) Citic Plaza No. 233 Tian He Road North Unit 1308 – 13th Floor Guangzhou, China Tel: +8620 3891 2000 Fax: +8620 3891 2111 E-mail: china-info@brocade.com
Document History
Title Publication number Summary of changes Date
Brocade Mobility RFS4000 Controller Installation Guide
Brocade Mobility RFS4000 Controller Installation Guide
53-1001933-02 Updated WEEE icon and
Korea Class B statement
53-1001933-01 New Document July 2010
May 2011
1 Introduction 1
Package contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Document conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Site preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
2 Specifications 5
Physical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Power cord specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Power protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3 LED Codes 7
System status LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Start up / POST (primary system or redundant system) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Controller status (primary system) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Controller status (Redundant System) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Fan LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Temperature status LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
RJ-45 Gigabit Ethernet LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
RJ-45 port speed LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
RJ-45 port activity LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
PoE status LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
SFP Gigabit Ethernet LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
SFP port speed LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
SFP port activity LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
4 Hardware Setup 13
Cabling Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Gigabit Ethernet on the Brocade Mobility RFS4000 Controller . . . . . . . . . . . . . . . .15
Installing Gigabit Ethernet SFPs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Connecting USB devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Rack mount instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Brocade Mobility RFS4000 Controller console port setup . . . . . . . . . . . . . . . . . . . .20
Supplying power to the Brocade Mobility RFS4000 Controller . . . . . . . . . . . . . . . . .22
Using the Brocade Mobility RFS4000 Controller reset button . . . . . . . . . . . . . . . . .23
Brocade Mobility RFS4000 Controller Installation Guide iii 53-1001933-02
Verifying the installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
5 Regulatory Information 25
Power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Country selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Laser devices - Gigabit Ethernet SFP option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Radio frequency interference requirements - FCC . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Radio frequency interference requirements - Canada . . . . . . . . . . . . . . . . . . . . . . . 27
CE Marking and European Economic Area (EEA) . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Statement of compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Japan (VCCI) - voluntary control council for interference Class B ITE . . . . . . . . . . . . . . . . . 28
Japan power cord statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Korea Warning Statement for Class B ITE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Waste Electrical and Electronic Equipment (WEEE) . . . . . . . . . . . . . . . . . . . . . . . . . 29
iv Brocade Mobility RFS4000 Controller Installation Guide
53-1001933-02

About This Document

In this chapter
Audience v
Supported hardware and software v
Document conventions vi
Contacting Brocade vi
Warranty coverage vii
Audience
This document is designed for system administrators with a working knowledge of Layer 2 and Layer 3 switching and routing.
If you are using a Brocade Layer 3 switch, you should be familiar with the following protocols if applicable to your network – IP, RIP, OSPF, BGP, ISIS, IGMP, PIM, DVMRP, and VRRP.
Supported hardware and software
The following hardware platforms are supported by this release of this guide:
Brocade Mobility RFS4000 Controller
The following software version is supported by this release of this guide:
Software version 4.3.0.0 and later
Brocade Mobility RFS4000 Controller Installation Guide v 53-1001933-02
Document conventions
This section describes text formatting conventions and important notice formats used in this document.
Notes, cautions, and warnings
The following notices and statements are used in this manual. They are listed below in order of increasing severity of potential hazards.
NOTE
A note provides a tip, guidance or advice, emphasizes important information, or provides a reference to related information.
CAUTION
A Caution statement alerts you to situations that can be potentially hazardous to you or cause damage to hardware, firmware, software, or data.
DANGER
A Danger statement indicates conditions or situations that can be potentially lethal or extremely hazardous to you. Safety labels are also attached directly to products to warn of these conditions or situations.
Contacting Brocade
When contacting Brocade support, please provide the following information:
Serial number of the unit
Model number or product name
Software version
vi Brocade Mobility RFS4000 Controller Installation Guide
53-1001933-02
Customer Support Web Site
Brocade Support Central Web site, located at www.brocade.com/support provides information and online assistance including developer tools, software downloads, product manuals and online repair requests.
Downloads
http://www.brocade.com/support/
Manuals
http://www.brocade.com/support/
Because quality is our first concern at Brocade, we have made every effort to ensure the accuracy and completeness of this document. However, if you find an error or an omission, or you think that a topic needs further development, we want to hear from you. Forward your feedback to: documentation@brocade.com
Provide the title and version number and as much detail as possible about your comment, including the topic heading and page number and your suggestions for improvement.
.
E-mail and telephone access
Go to http://www.brocade.com/services-support/index.page for email and telephone contact information.
Warranty coverage
Contact Brocade Communications Systems using any of the methods listed above for information about the standard and extended warranties.
Brocade Mobility RFS4000 Controller Installation Guide vii 53-1001933-02
viii Brocade Mobility RFS4000 Controller Installation Guide
53-1001933-02
Chapter

Introduction

In this chapter
Package contents 2
Document conventions 2
Warnings 3
Site preparation 3
The Brocade Mobility RFS4000 Controller is a member of Brocade’s Mobility wireless controller family. The Brocade Mobility RFS4000 Controller provides centralized Wireless LAN (WLAN) configuration and management by coalescing a network “intelligence” previously spread across physically distributed access points. The Brocade Mobility RFS4000 Controller simplifies deployment of a Wired/Wireless 802.11 a/b/g/n network, for a SME/SMB. With the integrated Layer 2/Layer 3 Networking Services such as integrated Layer 2 Switching with PoE+ ports, Onboard DHCP Server, Security Services like Wired/Wireless Firewall, Wireless IDS/IPS, Onboard AAA Server and IPSEC VPN Gateway, and QoS mechanisms to support Voice & Video , the Brocade Mobility RFS4000 Controller transforms the enterprise by delivering a SMART Branch. The Brocade Mobility RFS4000 Controller is the WLAN’s point of management reducing wireless networking complexity by moving management out of the ceiling and into the wiring closet. The RFS4000 can adopt upto 6 Adaptive APs or Thin Access Points and does not require any additional licenses at this time, for AP adoption.
1
This document is written for the network device installer.
Brocade Mobility RFS4000 Controller Installation Guide 1 53-1001933-02

Package contents

1
Package contents
Inspect the package contents and report any missing or damaged items to your sales representative. The package should contain the following:
Brocade Mobility RFS4000 Controller
Console Cable
Installation Guide (this document)
Rubber Feet
Power Supply Unit (Part Number: 50-14000-244R)

Document conventions

The following graphical alerts are used in this document to indicate notable situations:
NOTE
Tips, hints, or special requirements that you should take note of.
CAUTION
Care is required. Disregarding a caution can result in data loss or equipment malfunction.
DANGER
Indicates a condition or procedure that could result in personal injury or equipment damage.
2 Brocade Mobility RFS4000 Controller Installation Guide
53-1001933-02

Warnings

Warnings
Read all installation instructions and site survey reports, and verify correct
Remove jewelry and watches before installing this equipment.
Install the equipment in a rack or on a desktop with adequate dimensions and
Verify the unit is grounded before connecting it to the power source.
Verify any device connected to this unit is properly wired and grounded.
Connect all power cords to a properly wired and grounded electrical circuit.
Verify the electrical circuits have appropriate overload protection.
Brocade strongly recommends the use of an Uninterruptible Power Supply
Verify that the power connector and socket are accessible at all times during
Do not work with power circuits in dimly lit spaces.
Do not install this equipment or work with its power circuits during
Verify there is adequate ventilation around the device, and ambient
This product is designed for in building installation only and is not intended to
1
equipment installation before connecting the system to its power source.
weight allowances.
(UPS) that supports the Brocade Mobility RFS4000 Controller power rating. Not using a UPS can result in data loss or equipment damage due to a power surge or power failure.
the operation of the equipment.
thunderstorms or other weather conditions that could cause a power surge.
temperatures meet equipment operation specifications.
be connected to exposed (outside plant) networks.

Site preparation

Consult your site survey and network analysis reports to determine specific
equipment placement, port capacity, power drops, and so on.
Assign installation responsibility to the appropriate personnel.
Identify where all installed components are located.
Verify appropriate rack mounting requirements, as required.
Provide a sufficient number of power drops for your equipment.
Brocade Mobility RFS4000 Controller Installation Guide 3 53-1001933-02
Site preparation
1
Ensure adequate, dust-free ventilation to all installed equipment.
Identify and prepare Ethernet and console port connections.
Verify that cable lengths are within the maximum allowable distances for
optimal signal transmission.
Verify that the Brocade Mobility RFS4000 Controller is powered through an
Uninterruptible Power Supply (UPS).
4 Brocade Mobility RFS4000 Controller Installation Guide
53-1001933-02
Chapter

Specifications

In this chapter
Physical specifications 5
Power cord specifications 5

Physical specifications

Width
Height
Depth
Weight
Operating Temperature
Operating Humidity
2
304.8mm (12.0in)
44.45mm (1.75 in) 1 RU
254mm (10.0 in)
2.15 Kg (4.75 lbs)
0°C - 40°C (32°F - 104°F)
5% - 85% RH, non-condensing
Operating Altitude
10,000 ft @ 28deg C < 15% Relative Humidity

Power cord specifications

A power supply is included, however a power cord is not supplied with the switch. Use only a correctly rated power cord certified (as appropriate) for the country of operation

Power protection

If possible, use a circuit dedicated to data processing equipment. Commercial
Brocade Mobility RFS4000 Controller Installation Guide 5 53-1001933-02
.
electrical contractors are familiar with wiring for data processing equipment and can help with the load balancing of these circuits.
Power cord specifications
2
Install surge protection. Be sure to use a surge protection device between the
electricity source and the Brocade Mobility RFS4000 Controller.
Install an Uninterruptible Power Supply (UPS). A UPS provides continuous
power during a power outage. Some UPS devices have integral surge protection. UPS equipment requires periodic maintenance to ensure reliability. A UPS of the proper capacity for the data processing equipment must be purchased.
6 Brocade Mobility RFS4000 Controller Installation Guide
53-1001933-02
Chapter

LED Codes

In this chapter
System status LEDs 7
RJ-45 Gigabit Ethernet LEDs 10
SFP Gigabit Ethernet LEDs 11
The Brocade Mobility RFS4000 Controller has four vertically-stacked LEDs on its front panel. Each of the six Gigabit Ethernet Ports have two status LEDs. These LEDs display two colors (green & amber), and three lit states (solid, blinking, and off). The following tables decode the combinations of LED colors and states for the System Status LEDs and the Gigabit Ethernet LEDs.

System status LEDs

3
System Status 1
1
SYS
System Status 2
Fan status
Temperature status
Brocade Mobility RFS4000 Controller Installation Guide 7 53-1001933-02
2
System status LEDs
3

Start up / POST (primary system or redundant system)

System status 1 LED System status 2 LED Event
off off power off
green blinking green blinking power on self test (POST)
green solid green blinking post succeeded (operating
green solid off post succeeded (normal
amber blinking off post failure
alternating green blinking & amber blinking
NOTE
During controller start up, the Temperature status LED will be lit Solid Amber. This is normal behavior and does not indicate an error. At the completion of start up the Temperature Status LED will controller to Solid Green.
alternating green blinking & amber blinking
running
system loading)
operation)
system boot up error

Controller status (primary system)

System status 1 LED
off off power off
green solid off redundancy feature enabled
green solid green solid redundancy feature enabled
green solid amber blinking no country code configured on the controller or access
8 Brocade Mobility RFS4000 Controller Installation Guide
System status 2 LED
Event
primary system normal operation no access ports adopted
primary system normal operation actively adopting access ports
port or adaptive ap license and country code configured, but no aps adopted
53-1001933-02
System status LEDs

Controller status (Redundant System)

3
System status 1 LED
off off power off
green solid off redundant system normal operation
green blinking green solid redundant system failed over and adopting
green blinking alternating green blinking &
System status 2 LED Event
ports
redundant system not failed over.
amber blinking

Fan LED

Fan LED Event
off system off / POST start
green blinking POST in process
green solid all system fans normal operation
amber solid redundant cooling failure system operational
amber blinking system cooling failure - system will be held in reset until the issue
is resolved

Temperature status LED

Temperature LED Event
off system off
green solid ambient inlet temperature is within specified operating limit
amber solid ambient inlet temperature is near the maximum operating
temperature. during controller start up this LED will be lit solid amber. this is normal behavior and does not indicate an error.
amber blinking ambient inlet temperature is above the maximum specified
operating temperature. system will be held in reset until the issue
is resolved
Brocade Mobility RFS4000 Controller Installation Guide 9 53-1001933-02

RJ-45 Gigabit Ethernet LEDs

3
RJ-45 Gigabit Ethernet LEDs
LAN
PoE
21

RJ-45 port speed LED

Port speed LED Event
off 10 Mbps
green solid 100 Mbps
green blinking 1000 Mbps
amber blinking port fault
3
4
5

RJ-45 port activity LED

Port status LED Event
off no link or administratively shut down
green solid link present
10 Brocade Mobility RFS4000 Controller Installation Guide
53-1001933-02

SFP Gigabit Ethernet LEDs

Port status LED Event
green blinking activity: transmit and receive
amber blinking link fault

PoE status LED

Port status LED Event
off PoE disabled or not in use
green solid PoE enabled and powering port
amber solid PoE over-limit
amber blinking PoE port fault
SFP Gigabit Ethernet LEDs
3
UPLINK
SFP
Port speed
Port activity
Brocade Mobility RFS4000 Controller Installation Guide 11 53-1001933-02
SFP Gigabit Ethernet LEDs
3

SFP port speed LED

Port speed LED Event
green blinking 1000 Mbps
amber blinking module or Tx/Rx fault loss

SFP port activity LED

Port status LED Event
off no link or administratively shut down
green solid link present / operational
amber blinking module or Tx/Rx fault loss
12 Brocade Mobility RFS4000 Controller Installation Guide
53-1001933-02
Chapter

Hardware Setup

This chapter contains the following sections:
Cabling Information 14
Gigabit Ethernet on the Brocade Mobility RFS4000 Controller 15
Connecting USB devices 18
Rack mount instructions 19
Brocade Mobility RFS4000 Controller console port setup 20
Supplying power to the Brocade Mobility RFS4000 Controller 22
Using the Brocade Mobility RFS4000 Controller reset button 23
Verifying the installation 24
4
Console
/$13R(HQDEOHGJLJDELWHWKHUQHW
SRUWV
Brocade Mobility RFS4000 Controller Installation Guide 13 53-1001933-02
:$1
USB83/,1.
([SUHVV&DUG6ORW

Cabling Information

4
Cabling Information
The Brocade Mobility RFS4000 Controller has five RJ-45 Gigabit Ethernet ports, one Gigabit SFP (fiber) port, one USB port, one Console connector and one ExpressCard slot. The above diagram shows each of those ports and the cables or devices attached to them. The sections that follow describe detailed connection and cabling information for each port. For software configuration, please see the Brocade Mobility RFS4000, RFS6000 and RFS7000 System Reference Guide available from the Brocade website at http://www.brocade.com/support/
14 Brocade Mobility RFS4000 Controller Installation Guide
..
53-1001933-02

Gigabit Ethernet on the Brocade Mobility RFS4000 Controller

Gigabit Ethernet on the Brocade Mobility RFS4000 Controller
The Brocade Mobility RFS4000 Controller has five RJ-45 Gigabit Ethernet ports and one 1 combo Gigabit (RJ45 + SFP) uplink port. Using the RJ-45 ports requires connecting a Category-6 Ethernet cable to the port. To use the Gigabit SFP port, first install the SFP Module.

Installing Gigabit Ethernet SFPs

1. Open the bail on the transceiver.
4
Open bail to insert or remove SFP transceiver
Brocade Mobility RFS4000 Controller Installation Guide 15 53-1001933-02
Gigabit Ethernet on the Brocade Mobility RFS4000 Controller
4
2. Insert the SFP transceiver into the corresponding port on the controller.
3. Once the SFP transceivers are properly seated in their ports, close the bails to lock the transceivers in place.
Close bail to lock SFP transceiver in place
4. Insert the fiber optic cables into the installed transceivers.
16 Brocade Mobility RFS4000 Controller Installation Guide
53-1001933-02
Gigabit Ethernet on the Brocade Mobility RFS4000 Controller
4
Brocade Mobility RFS4000 Controller Installation Guide 17 53-1001933-02

Connecting USB devices

4
Connecting USB devices
USB
port
The Brocade Mobility RFS4000 Controller contains one USB port for connecting USB flash storage devices to the controller. The controller can use the USB flash storage device for file transfers and firmware updates. Follow the setup instructions below to connect the devices to the controller and then access those devices through the Web UI or Command Line Interface.
1. Connect the USB flash drive to the USB .
2. Wait a few seconds for the drive to be recognized by the controller.
3. Follow the instructions in the Brocade Mobility RFS4000, RFS6000 and
RFS7000 System Reference Guide or Brocade Mobility RFS4000, RFS6000 and RFS7000 CLI Reference Guide for more information on accessing USB
storage devices from the controller for file transfers or firmware updates. These guides are available from the Brocade website at
http://www.brocade.com/support/
18 Brocade Mobility RFS4000 Controller Installation Guide
53-1001933-02

Rack mount instructions

Attach to Rack
1U Rack Mount Kit
Back
Switch Guides
Front
Power Supply Guide
Cable Management
NOTE
The controller supports USB flash devices formatted with FAT or VFAT (FAT32) filesystems only. If your flash storage device is formatted with another filesystem you will need to format
Rack mount instructions
To install the Brocade Mobility RFS4000 Controller in a rack:
1. Attach the controller to the 1U rack mount kit (Part Number
RFS-4010-MTKT1U-WR) using the guides provided.
4
Brocade Mobility RFS4000 Controller Installation Guide 19 53-1001933-02
2. Place the power supply unit in the rack mount tray in the space provided.

Brocade Mobility RFS4000 Controller console port setup

4
3. Attach the mounting tray to the rack using screws appropriate for your rack’s mounting holes.
Brocade Mobility RFS4000 Controller console port setup
To add the Brocade Mobility RFS4000 Controller to the network and prepare it for initial configuration:
1. Using the supplied console cable (pictured below), connect the Brocade Mobility RFS4000 Controller serial port to an RS-232 (DB-9) serial port on a separate computer (the “configuration computer”).
The pinout for the RJ-45 to DB9 cable is shown in the following table.
RJ-45 1 2 3 4,5 6 7 8
DB9 8 6 2 5 3 4 7
20 Brocade Mobility RFS4000 Controller Installation Guide
53-1001933-02
Brocade Mobility RFS4000 Controller console port setup
2. On the configuration computer, configure a terminal emulation application
(such as HyperTerminal) as follows:
3. On the configuration computer, configure a terminal emulation application
(such as HyperTerminal) as follows:
4
Terminal type
Port
Terminal settings
Brocade Mobility RFS4000 Controller Installation Guide 21 53-1001933-02
VT-100
COM port
19200bps transfer rate 8 data bits no parity 1 stop bit no flow control no hardware compression

Supplying power to the Brocade Mobility RFS4000 Controller

4
Supplying power to the Brocade Mobility RFS4000 Controller
Power Inlet
1. Plug the power supply (Part Number: 50-14000-244R) into the power inlet at the back of the Brocade Mobility RFS4000 Controller.
2. Plug the cord into a standard AC outlet with a voltage range of 100 to 240 VAC.
CAUTION
An improper shutdown can render the Brocade Mobility RFS4000 Controller inoperable such that it could require service by Brocade Support. Do not remove AC power without first following the shutdown procedure. An abrupt loss of power can corrupt the information stored on the device.
22 Brocade Mobility RFS4000 Controller Installation Guide
53-1001933-02

Using the Brocade Mobility RFS4000 Controller reset button

4
Using the Brocade Mobility RFS4000 Controller reset button
Reset Button
The Brocade Mobility RFS4000 Controller has a reset button on the rear of the switch near the power connector.
To reset the switch to factory defaults:
1. Connect a computer to the Console Port as outlined in Brocade Mobility
RFS4000 Controller console port setup on page 4-20
2. Reset the switch using the Web UI or the Command Line Interface.
3. As soon as the switch resets, depress the reset button on the rear of the switch
and continue to hold it through the boot up process until the following message is displayed in the console:
Startup config will be RESET to factory default
loading linux image 2 .......................
Welcome to RFS4000
Brocade Mobility RFS4000 Controller Installation Guide 23 53-1001933-02

Verifying the installation

4
CAUTION
Using the switch reset button will reset all configuration information and settings on the switch to factory defaults. All previously configured information and settings will be lost. The country code will need to be set when the switch is rebooted before any access ports or adaptive APs will be adopted.
Verifying the installation
View the LEDs on the front panel of the Brocade Mobility RFS4000 Controller to ensure the device is functioning properly. The normal LED pattern follows this path:
During the Power On Self Test (POST), the System 1 and System 2 LEDs both
blink green.
If the POST test fails, the System 1 LED will blink amber. If the POST test
succeeds, the System 1 LED will be lit solid green.
As the software is initialized, the System 2 LED will blink green.
After the software has finished initializing, the System 1 LED will be lit solid green and the bottom System 2 LED will be off. The Brocade Mobility RFS4000 Controller is ready to be configured, as described in the Brocade Mobility RFS4000, RFS6000 and RFS7000 System Reference Guide available from the Brocade website at
http://www.brocade.com/support/.
Other LED codes indicate the presence (or absence) of different standby states, or errors. A guide to the Brocade Mobility RFS4000 Controller LED codes is provided in
LED Codes on page 3-7.
24 Brocade Mobility RFS4000 Controller Installation Guide
53-1001933-02
Chapter

Regulatory Information

In this chapter
Country selection 26
Laser devices - Gigabit Ethernet SFP option 26
Radio frequency interference requirements - FCC 26
Radio frequency interference requirements - Canada 27
CE Marking and European Economic Area (EEA) 27
Waste Electrical and Electronic Equipment (WEEE) 29
This regulatory section applies to the Brocade Mobility RFS4000 Controller.
All Brocade devices are designed to be compliant with rules and regulations in locations they are sold and will be labeled as required.
Any changes or modifications to Brocade equipment, not expressly approved by Brocade, could void the user’s authority to operate the equipment.
CAUTION
This product is designed and approved for in-building installation only and is not intended to be connected to exposed (outside plant) networks.
5

Power supply

Use only a Brocade approved power supply output rated at 48Vdc and minimum
2.5A. The power supply shall be Listed to UL/CSA 60950-1; and certified to IEC60950-1 and EN60950-1 with SELV outputs. Use of alternative power supply will invalidate any approval given to this device and may be dangerous.
Brocade Mobility RFS4000 Controller Installation Guide 25 53-1001933-02

Country selection

5
Country selection
Select only the country in which you are using the device. Any other selection will make the operation of this device illegal.

Laser devices - Gigabit Ethernet SFP option

!
Complies with 21CFR1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated July 26, 2001.
EN60825-1:1994+ A1:2002 +A2:2001
IEC60825-1:1993+A1:1997+A2:2001
The laser classification is marked on the device.
Class 1 Laser devices are not considered to be hazardous when used for their intended purpose. The following statement is required to comply with US and international regulations:
CAUTION
Use of controls, adjustments or performance of procedures other than those specified herein may result in hazardous laser light exposure.

Radio frequency interference requirements - FCC

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However there is no guarantee that interference will not occur in a particular
26 Brocade Mobility RFS4000 Controller Installation Guide
53-1001933-02

Radio frequency interference requirements - Canada

installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna
Increase the separation between the equipment and receiver
Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected
Consult the dealer or an experienced radio/TV technician for help.
Radio frequency interference requirements - Canada
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.

CE Marking and European Economic Area (EEA)

5

Statement of compliance

Brocade hereby declares that this device is in compliance with all the applicable Directives, 2004/108/EC, 2006/95/EC. A Declaration of Conformity may be obtained from http://www.2symbol.com/doc/
Brocade Mobility RFS4000 Controller Installation Guide 27 53-1001933-02
CE Marking and European Economic Area (EEA)
5

Japan (VCCI) - voluntary control council for interference Class B ITE

この装置は、情報処理装置等電波障害自主規制協議会 (VCCI)の基準に基 づくクラス B 情報技術装置です。この装置は、家庭環境で使用することを目的 としていますが、この装置がラジオやテレビジョン受信機に近接して使用され ると、受信障害を引き起こすことがあります。 取扱説明書に従って正しい取り 扱いをして下さい。
This is a Class B product based on the standard of the Voluntary Control Council for Interference from Information Technology Equipment (VCCI). If this is used near a radio or television receiver in a domestic environment, it may cause radio interference. Install and use the equipment according to the instruction manual.

Japan power cord statement

Korea Warning Statement for Class B ITE

Class B device (Broadcasting Communication Device for Home Use): This device obtained EMC registration mainly for home use (Class B) and may be used in all areas
Turkish WEEE Statement of Compliance
EEE Yönetmeli?ine Uygundur
28 Brocade Mobility RFS4000 Controller Installation Guide
53-1001933-02

Waste Electrical and Electronic Equipment (WEEE)

5
Waste Electrical and Electronic Equipment (WEEE)
For information on WEEE, please go to:
http://www.brocade.com/sites/dotcom/company/ corporate-responsibility/corporate-citizenship/product-recycling/ weee.page.
Brocade Mobility RFS4000 Controller Installation Guide 29 53-1001933-02
Waste Electrical and Electronic Equipment (WEEE)
5
30 Brocade Mobility RFS4000 Controller Installation Guide
53-1001933-02
Loading...