Broan HRV90H User Manual

HRV90H
ERV90HC
HRV90H
FRESH AIR SYSTEM
SPECIFICATION SHEET
FEATURES
20% smaller than comparable units / Designed for
applications where space is critical, such as closet and utility rooms in condominiums, apartments, and pre-fabricated homes. Also has compact footprint
design for an easy t in mechanical rooms, closets, and other tight-t applications. A versatile solution for
the most demanding applications.
State-of-the-art ventilation technology / Performance
sized for new ventilation standards and will not over-dry the house. The most exible Heat Recovery
Ventilator (HRV) on the market.
Bottom door opening / Design allows easy access
from any angle.
Side (HRV90HS) and top (HRV90HT) port
conguration / Versatile design allows for vertical or horizontal conguration, facilitating installation and maintenance (factory-congured).
Removable electric drawer / Easy maintenance of
major sub-components.
Interchangeable core / Allows unit to be changed from
HRV to ERV in the summer.
Convenient three-mode wall control (VT4W)
(Optional) (Min/Max Intermittent: 20-min. On / 40-min.
Off).
GENERAL SPECIFICATIONS
For houses up to 3,000 sq. ft.
45 to 96 cfm (0.4 in. w.g.)
Voltage: 120 VAC
Frequency: 60 Hz
Dimensions: 12.81” x 22.56” x 19.81”
Weight: 39 lbs
Shipping Weight: 42 lbs
Warranty: 2 years on parts - 10 years on core
HVI Rated of air ow: 106 cfm
Power Consumed (max): 150 Watts
Supply air duct connections: 5” diameter
Exhaust air duct connections: 5” diameter
Filter: 30 ppi washable reticulated foam
Cabinet: 20 ga. Pre-painted steel
Mounting: Suspension by chains and springs
Wall control modes: Low/High Speeds
Power: 150 Watts
Current: 1.3 Amps
Continuous duty, permanently lubricated motors
36” power cord
Broan-NuTone LLC Hartford, Wisconsin www.broan.com 800-558-1711
REFERENCE QTY. REMARKS Project
Location
Architect
Engineer
Contractor
Submitted by Date
MODEL HRV90H
W arm
Cold
Cold
Cold
Cold
W
arm
W arm
W arm
Cold
Cold
Cold
Cold
W
arm
W arm
PERFORMANCE SPECIFICATIONS
Ventilation Performance
External
Static Pressure
Net Supply Airflow
Gross Airflow
Supply Exhaust
Pa In. W.g. L/s cfm L/s cfm L/s cfm
25 0.1 52 110 52 110 57 122
50 0.2 50 106 50 106 55 116
75 0.3 48 101 48 102 53 113
100 0.4 45 96 46 97 50 1 07
125 0.5 43 92 43 92 48 1 03
150 0.6 41 87 41 87 45 96
175 0.7 38 81 38 81 43 91
Energy Performance
Sensible
Recovery
Efficiency
Supply Temperature Net Airflow
Average
Power
Heating C F L/s cfm Wat ts % %
0 32 23 48 68 66 78 0.07
0 32 30 63 82 65 76 0.04
0 32 44 93 116 59 68 0.04
-25 -13 30 63 110 55 81 0.08
Tota l R eco ver y E ffi cie ncy
Cooling 3 5 95 Not Tes ted
Apparent
Sensible
Effectiveness
Latent
Recovery
Moisture
Transfer
INSTALLATION OPTIONS
Bulkhead Installation
(Mechanical Room)
Broan-NuTone LLC Hartford, Wisconsin www.broan.com 800-558-1711
- Return Connection
Direct Exhaust
Return-Return
Connection
Loading...