Boss Genesis Cafe Installation And Service Manual

The Coffee
Professor
Reverse Osmosis System
Model – Genesis Cafe
advanced water purifier system available!
Installation and Service Guide
PLEASE READ THIS MANUAL CAREFULLY BEFORE
ATTEMPTING INSTALLATION
Page 1
REVERSE OSMOSIS WATER PURIFIERS
Of all methods that purify drinking water for domestic use, the process of REVERSE OSMOSIS is the most advanced, economical and effective. REVERSE OSMOSIS has the ability, unlike conventional filters, to remove contaminants such as dissolved solids and all other impurities.
The REVERSE OSMOSIS (RO) process works by forcing water under pressure through a special TFC Membrane. The membrane has the astounding quality of attracting water molecules and repelling dissolved impurities, even those smaller than the water molecules themselves.
The REVERSE OSMOSIS (RO) purifiers remove all the contaminants of concern to the consumer such as bacteria, viruses, parasites, heavy metals, inorganic chemicals, pesticides and algae.
RO purifiers flush the impurities down the drain rather than collecting them in the filters, as is the case with ordinary systems, preventing any build up within the system.
Also RO systems oxygenate the water giving it a lively fresh taste, unlike distilled water, which may have a flat dead taste.
With REVERSE OSMOSIS, you can be rest assured your drinking water is of the highest quality possible and the best possible investment for your families’ health.
HOW DOES IT WORK?
Polluted water is forced by mains water pressure against a semi-permeable membrane. Purified water molecules easily pass through the membrane while pollutants, typically being larger than the pores ( .0005 of a micron in size), cannot pass through and are washed away.
Please read this entire service guide before beginning installation
Page 2
This Reverse Osmosis Drinking Water System has been designed for simple installation and maintenance. By carefully reading this instruction manual and following the operational guidelines you will ensure a successful installation and reliable operation. Routine maintenance is essential to the longevity and performance of the system. Filters should be changed as per service intervals indicated on page 4.
CONDITIONS FOR OPERATION
Source Water Supply – TFC
System Pressure
40 - 90 PSI (300 - 620 kpa)
Temperature
2º - 40º C (36º - 104º F)
pH Range
3.0 - 11.0
Maximum Supply TDS Level
500 mg/L Turbidity
<1.0 Net Turbidity (NTU)
CAUTION
DO NOT USE THIS SYSTEM WHERE THE WATER IS MICROBIOLOGICALLY UNSAFE OR OF UKNOWN QUALITY WITHOUT FIRST CHECKING WITH YOUR DISTRIBUTOR. THIS SYSTEM IS DESIGNED FOR USE ON POTABLE WATER WITHIN THE ABOVE CONDITIONS FOR OPERATION.
ROCAFE
Reverse Osmosis Purifier
The ROCAFE drinking water purifier represents the very latest in design and ultimately has become the standard for the drinking water industry. The ROCAFE model remains unequalled in quality, reliability and overall performance.
Years of engineering experience, field-testing and continued design refinement combines to make the ROCAFE the best in its class.
STAGE 1 SEDIMENT PRE-FILTER
For Mechanical Filtration
Protects and extends the life of the membrane. Removes sediment particles –
grit, dust, rust, mud, algae etc.
STAGE 2 CARBON PRE-FILTER
For Membrane Protection
Page 3
A special high-grade carbon cartridge pre-filter is added to protect the TFC
Membrane from chlorine degradation.
Specially designed to remove – pesticides and other organic pollutants e.g.
chlorine, THM, TCE etc. Contains special acid washed, dedusted carbon with excellent absorbent qualities.
STAGE 3 ULTRAFINE RO MEMBRANE
Screens out the most minute microparticles. Pore size less than .0005 micron ( 1 micron = one thousand of a Millimetre) Effectively repels: heavy metal complexes including aluminium, lead, mercury etc,
microorganisms and colloidal matter.
STAGE 4 CARBON POLISHING POST-FILTER
Provides final polish resulting in superb tasting water.
STAGE 5 CALCITE RE-MINERALISER
CARTRIDGE REPLACEMENT
Sediment Pre-Filter
Up to 12 months
Carbon Pre-Filter
Up to 12 months
TFC RO Membrane
3 – 5 years
Carbon Post-Filter
12 to 24 months
Post Calcite Re-Mineraliser
24 to 48 month
INSTALLATION
Preparation
Check the following list of components to ensure that all parts are packed with your system
1 – Storage Tank 1 – RO System 1 – RO Water Faucet 1 – Installation Kit
Determine the location for the installation of the RO system. Avoid locations where the system might come in contact with hot water pipes or other hazards, taking into consideration ease of maintenance.
Determine the location for the faucet. Check to see that drilling the faucet hole will not damage pipes or wires running underneath the sink.
Determine the location for the storage tank. A maximum distance from tank to faucet of 4 metres (12 feet) is possible. The system will produce a faster flow at the faucet with the shortest tubing run from tank to faucet.
All tubing is colour coded for ease of installation. 1/4” Blue – Connects the feed water valve to the RO pre-filter. 1/4” Yellow – Connects the RO membrane product port to the storage tank. 1/4” Black – Connects the membrane brine port to the drain connector. 1/4” White – Connects the post-filter to the faucet.
Page 4
Loading...