Long Range PIR with POPIT Interface ZX794Z
Installation Instructions
Trademark names are used throughout this document. In most cases, these designations are claimed as trademarks or
registered trademarks in one or more countries by their respective owners. Rather than placing a trademark symbol in
every occurrence of a trademark name, Bosch Security Systems, Inc. (hereinafter referred to as Bosch) uses the names only
in an editorial fashion and to the benefit of the trademark owner with no intention of infringing the trademark.
1.0 Specifications
• Coverage: Standard OA80 80 ft. by 50 ft. (24.4 m by 15.3 m )
Optional OA120 120 ft. by 25 ft. (36.6 m by 7.6 m)
Optional OA200 200 ft. by 10 ft. (61.0 m by 3.1 m)
• Input Power: Connect to the Zonex Bus of the control panel.
• Current Draw: Less than 500 micro-amps. Two milliamps when in walk test mode (LED on).
• Standby Power: Standby power supplied by the Zonex Bus. 500 micro-amp-hours required for each hour of
standby time needed. Four hours minimum is required for UL Listed Requirements.
• Sensitivity: Field selectable for Standard, Intermediate, or High.
• Tamper: A tamper condition is signaled through the Zonex Bus and displayed at the keypads when the cover
is removed.
• Temperature: The storage and operating range is -20° to +120°F (-29° to +49°C). For UL Listed Requirements,
the range is +32° to +120°F (0° to +49°C).
• Requirements: Compatible Bosch Security Systems control panel with POPEX module installed.
• Options: OA120-2* Long Range Optical Assembly, OA200-2* Long Range Optical Assembly, and TC6000
Test Cord.*
• Reading Bosch Security Systems, Inc. Product Date Codes: For Product Date Code information, refer to the
Bosch Security Systems, Inc. Web site at: http://www.boschsecurity.com/datecodes/
*Shipped in packages of two
2.0 Programming
Program the address DIP switches as described for the control panel you are using.
Note: When installing with a D7212B1, D8112, or D9112B1; place switch number “0” in the ON position.
Recommended point type programming: D8112 = 7571
D9112B1/D7212B1 = Point type 2, point response 2, no ring until restored.
D9412/D9112 = Point type 2, point response E, no ring until restored.
ZX794Z
3.0 Mounting
Select a location likely to intercept an intruder moving across the coverage pattern (review Section 10.0 Coverage Patterns,
page 8). The recommended mounting height is 7.5 ft. (2.3 m) when using the OA80 or OA120, or 10 ft. (3.1 m) when
using the OA200. Each mounting surface should be solid and vibration free.
• Remove the cover by inserting a thin screwdriver into each of the slots at the top and bottom of the cover. Twist
gently until the cover snaps free of the tabs on the base.
3.1 Bracket Mounting
Note: The use of the B334 Mounting Bracket (included) is strongly recommended when installing this detector.
Because variations exist in the surfaces of most mounting walls, most units are not mounted at perfect angles to the floor or
walls. This may cause the pattern to point away from the “ideal” direction.
For example: A shift of only 1 degree will cause a pattern shift of 1.7 ft. (0.52 m) at 100 ft. (30.5 m). Under worst case
conditions, this will cause the pattern to be aimed over the head of intruders at maximum range, or into walls of narrow
corridors. What may seem to be poor range or catch performance, may be the result of improper alignment.
To insure proper catch performance, a bracket mounted detector permits the flexibility needed to properly adjust the
direction of the coverage pattern.
ZX794Z Installation Instructions
F01U069538-08 Page 2 © 2011 Bosch Security Systems, Inc.
If Mounting to the B334 Mounting Bracket:
1. Remove the cover of the bracket by inserting a thin screwdriver into the notch on the side of the bracket and
twisting gently.
2. Insert the alarm and power wiring through the center hole from the rear of the B334 base. (Do not insert
wiring if the bracket is to be surface mounted).
3. Mount the B334 to a standard single-gang switch or outlet box using the supplied Bevel Head screws. (If
surface mounting the unit, use the wall screw/anchor assemblies or appropriate alternatives).
4. Remove the circuit board from its base. Press the two circuit board retainer tabs outward and lift the circuit
board away from the base.
5. Remove the sticker covering the entrance from the back of the detector base.
6. Insert the threaded stud through the appropriate stud hole in the B334 bracket. Use the bottom hole for wall
mounting, the front hole for ceiling mounting. Make sure the hex head is seated in place.
7. Complete the assembly by securing the detector base to the B334 bracket using the supplied curved washer and
hex nut (see Bracket to Base Assembly drawing).
8. Hand tighten the hex nut.
9. Thread the bracket wiring through the stud and along the wiring channel in the detector’s base to the area of
the circuit board’s terminal strip.
10. Return the circuit board to its base. Slide the back of the circuit board under the tabs at the back of the base,
then snap the front into place.
11. Aim the detector in the desired general direction and tighten the hex nut using the supplied hex wrench.
12. Should the detector require realignment, loosen the hex nut, reposition the detector, and then retighten the nut.
ZX794Z
ZX794Z Installation Instructions
© 2011 Bosch Security Systems, Inc. Page 3 F01U069538-08