Service Function Adjustment | 5
2.2.2 2. Service Level
Operating
Change or query of a service function
:
B To enter to 2. service level must be entered first in 1. level.
Press button for 5 second. The service function onf1.
level will be shown on Display (e.g. 1.2.C).
B To enter to 2. level : Press both “+” and “-” buttons for 3
second. The service function of 2. level will be shown on
Display (e.g. 2.1.A).
B Select the desired/requested service code with “+” or “-”
button.
B Press button again (for entering)..
After that you will see the selected (default) value on Display.
Changing / Adjustment of Value:
B Change the values with “+” or “-” button.
Storage/Save of Value :
B Press button until [ ] symbol will be shown on Display.
Exit from Service level :
B For the exit from service level press the or Stand by
button.
The flow temperature will be shown again on display.
2. Level
Service
Code
Description Range Initial (Factory Setting)
2.1.A CH max. heat output 30 - 100 % 100 %
2.1.b DHW max. heat ou tput (in winter mode) 30 - 100 % 100 %
2.2.b CH max flow temperature 35 - 82°C 82°C
2.3.d CH min. heat output 30 - 100 % 30 %
2.3.F Delay time after DHW in winter mode (Heating mode is disabled for this
period of time)
0 - 5 min. 1 min.
2.8.A Software version number e.g.. 162 112 -
2.8.E Reset to factory (default) setting 0 0
2.9.A Operation mode permanent : (0 = Normal, 1= min. power, 2 = max.
power)
0 - 2 0
2.9.E Delay time for the turbine ( each unit = 0,5 sec.) 1 - 6 2
2.9.F Pump over run) (CH circuit) 0 - 10 min. 3
2.A.A Actual flow temperature ºC -
2.A.b Actual DHW temperatur ºC -
2.A.F Actual combustion chamber temperature ºC -
2.b.d Selection of flue length (MAP Value) (0 = off, 1 - 10 : fan speed accord-
ing flue pipe length, see flue manuel for details)
0 - 10 0
2.b.F Solar mode delay time (sec.) 1 - 50 1
2.c.F Pump "over run” (DHW mode) 0 - 30 sec. 5 sec.
2.0.A Gas Convertion (0 = NG, 1 = LPG) 0 -1 0
Tab. 2 2. level service functions