-1 dB
-2 dB
-3 dB
-1 dB
-2 dB
-3 dB
10 30 50 70 100 Hz 1 kHz 1MHz 5 MHz
40 dB
80 dB
120 dB
160 dB
10 30 50 70 100 Hz 1 kHz
Video | TC8235GIT Ground Loop Isolation Transformer
TC8235GIT Ground Loop Isolation
Transformer
www.boschsecurity.com
u Ground isolation for 75 Ohm video/data lines
u 10 Hz to 7 MHz bandwidth
The TC8235GIT is a one-to-one isolation transformer
for 75 Ohm coax video/data lines. These units are
designed to eliminate the effects of power line and
spurious noise potentials between ground points on
transmitted signals.
Installation/configuration notes
Signal Transmission
u Low insertion loss
u Insulated BNC connectors
u Excellent discrimination against power line inter-
ground potentials
Ground Isolation
Circuit Diagram of Transformer
Input 75 Ω UNB
Output 75 Ω UNB
40.1
(1.58)
59.7
(2.35)
43.2
(1.70)
50.8
(2.00)
1
38.1
(1.50)
2 | TC8235GIT Ground Loop Isolation Transformer
Technical specifications
Electrical
Impedance Levels 75 Ω unbalanced, input and output
Insertion Loss 0.5 dB at 1 kHz
Return Loss Better than 20 dB,120 Hz to 5 MHz
Sine Wave Transmission(Bandwidth)
Amplitude Flat loss is 0.45 dB maximum at 15 kHz, 3 dB
down relative mid-frequency response at 10 Hz
and 7 MHz
Phase Linear with slope of 18 MHz,
1 MHz to 5 MHz
Ground Isolation En/Eo = 115 dB at 60 Hz (decreases with
frequency at 6 dB/octave to 30 dB minimum at
1 MHz
Dielectric Withstanding Voltage
500 Vrms, 60 Hz (from connectors to case and each other)
Mechanical
Weight 223 g (0.5 lb)
Finish Black
Ordering information
TC8235GIT Ground Loop Isolation Transformer
Order number TC8235GIT
Dimensional Outline in mm (inches)
1 Insulated BNC Connector (2)