Plena Mixer Amplifier | Installation and User Instructions | Important safeguards en | 2
Important safeguards
Alerts on the apparatus
This symbol found on the apparatus indicates
hazards arising from dangerous voltages.
This symbol found on the apparatus indicates
the user should read all safety statements found
in the operating instructions.
This symbol found on the apparatus indicates
double insulation.
Warning
To reduce the risk of fire or electrical shock, do
not expose this apparatus to rain or moisture.
This symbol found on the apparatus indicates
that the apparatus must be placed in a separate
collection facility for electronic waste and not
disposed with household waste.
1 Read instructions - All the safety instructions for use
should be read before the system is operated.
2 Retain instructions - The safety instructions and
operating instructions should be retained for future
reference.
3 Heed warnings - All warnings on the unit and in the
operating instructions should be adhered to.
4 Follow instructions - All operating instructions and
instructions for use should be followed.
5 Cleaning - Unplug system units from the mains
outlet before cleaning. Do not use liquid cleaners or
aerosol cleaners. Use only a dry cloth for cleaning.
6 Attachments - Do not use attachments not
recommended by the product manufacturer as they
may cause hazards.
7 Water and Moisture - Do not use this unit near water,
for example near a bathtub, washbowl, kitchen sink,
or laundry basket, in a wet basement, near a
swimming pool, in an unprotected outdoor
installation or any area which is classified as a wet
location.
8 Accessories - Do not place this unit on an unstable
stand, tripod, bracket or mount. This unit may fall,
causing serious injury to a person and serious
damage to the unit. Use only a stand, tripod, bracket
or mount recommended by the manufacturer, or
sold with the product. Any mounting of the unit
should follow the manufacturer's instructions, and
should use a mounting accessory recommended by
the manufacturer. An appliance and cart
combination should be moved with care. Quick
stops, excessive force, and uneven surfaces may
cause the appliance and cart combination to
overturn.
9 Ventilation - Openings in the enclosure, if any, are
provided for ventilation and to ensure reliable
operation of the unit and to protect it from
overheating. These openings must not be blocked or
covered. The unit should not be placed in a built-in
installation unless proper ventilation is provided or
the manufacturer's instructions have been adhered
to. Maintain a minimum distance of 2 inch (50 mm)
around the front, the rear, and the sides of the unit
for sufficient ventilation.
10 Heat sources - Do not install the unit near any heat
sources such as radiators, stoves, or other apparatus
that produce heat (including amplifiers).
11 Open flames - No open flames, such as lighted
candles, should be placed on the unit.
12 Power sources - Units should be operated only from
the type of power source indicated on the marking
label. If you are not sure of the type of power supply
you plan to use, consult your appliance dealer or
local power company. For units intended to operate
from battery power, or other sources, refer to the
"Installation and User Instructions".
13 Grounding or polarisation - This unit may be
equipped with a polarised alternating current line
plug (a plug having one blade wider than the other).
This plug will fit into the power outlet only one way.
This is a safety feature. If you are unable to insert the
plug fully into the outlet, try reversing the plug. If the
plug still fails to fit, contact your electrician to
replace your obsolete outlet. Do not defeat the safety
purpose of the polarised plug. Alternatively, this unit
may be equipped with a 3-wire grounding type plug
having a third (grounding) pin. This plug will only fit
into a grounding-type power outlet. This is a safety
feature. If you are unable to insert the plug into the
Bosch Security Systems | 2007-12 | PLE-1MA030-US, PLE-1MA060-US, PLE-1MA120-US en
Page 3
Plena Mixer Amplifier | Installation and User Instructions | Important safeguards en | 3
outlet, contact your electrician to replace your
obsolete outlet. Do not defeat the safety purpose of
the grounding-type lug.
14 Power-Cord Protection - Power supply cords should
be routed so that they are not likely to be walked on
or pinched by items placed upon or against them,
paying particular attention to cords and plugs,
convenience receptacles, and the point where they
exit from the appliance.
15 Overloading - Do not overload outlets and extension
cords as this can result in a risk of fire or electrical
shock.
16 Object and Liquid Entry - Never push objects of any
kind into this unit through openings as they may
touch dangerous voltage points or short-out parts
that could result in a fire or electric shock. Never
spill liquid of any kind on the unit.
17 Servicing - Do not attempt to service this unit
yourself as opening or removing covers may expose
to dangerous voltage or other hazards. Refer all
servicing to qualified service personnel.
18 Damage Requiring Service - Unplug the unit from
the outlet and refer servicing to qualified service
personnel under the following conditions:
•When the power-supply cord or plug is damaged.
•If liquid has been spilled, or objects have fallen
into the unit.
•If the unit has been exposed to rain or water.
•If the unit does not operate normally by following
the instructions for use. Adjust only those
controls that are covered by the instructions for
use, as an improper adjustment of other controls
may result in damage and will often require
extensive work by a qualified technician to
restore the units to their normal operation.
•If the unit has been dropped or the unit has been
damaged.
•When the unit exhibits a distinct change in
performance; this indicates a need for service.
19 Replacement Parts - When replacement parts are
required be sure the service technician has used
replacement parts specified by the manufacturer or
parts which have the same characteristics as the
original part. Unauthorised substitutions may result
in fire, electric shock or other hazards.
20 Safety Check - Upon completion of any service or
repairs to the units, ask the service technician to
perform safety checks to determine that the unit is in
proper operating condition.
21 Lightning - For added protection of the units during
a lightning storm, or when it is left unattended and
unused for long periods of time, unplug it from the
wall outlet and disconnect the cable system. This will
prevent damage to the unit due to lightning and
power-line surges.
22 Disconnection - To completely disconnect this unit
from the AC mains, disconnect the power supply
cord plug from the AC receptacle. The mains plug of
the power supply cord shall remain readily operable
to be able to disconnect power from the unit.
23 Before installing or operating this product, always
read the Safety Instructions, which are available as a
separate document (9922 141 7014x). These
instructions are supplied together with all equipment
that can be connected to the mains.
Bosch Security Systems | 2007-12 | PLE-1MA030-US, PLE-1MA060-US, PLE-1MA120-US en
Page 4
Plena Mixer Amplifier | Installation and User Instructions | Important safeguards en | 4
American Users
Note
This equipment has been tested and found to
comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC rules.
These limits are designed to provide reasonable
protection against harmful interference in a
residential installation.
This equipment generates, uses, and can
radiate radio frequency energy and, if not
installed and used in accordance with the
instructions, may cause harmful interference to
radio communications. However, there is no
guarantee that interference will not occur in a
particular installation. If this equipment does
cause harmful interference to radio or television
reception, which can be determined by turning
the equipment OFF and ON, the user is
encouraged to try to correct the interference by
one or more of the following measures:
•Reorient or relocate the receiving antenna.
•Increase the separation between the
equipment and the receiver.
•Connect the equipment into an outlet on a
circuit different from that to which the
receiver is connected.
•Consult the dealer or an experienced
radio/TV technician for help.
Canadian Users
Note
This Class B digital device complies with
Canadian ICES-003.
Cet appareil numérique de classe B est
conforme à la norme NMB-003 du Canada.
Thank you for choosing a Bosch Security Systems
product!
Bosch Security Systems | 2007-12 | PLE-1MA030-US, PLE-1MA060-US, PLE-1MA120-US en
Page 5
Plena Mixer Amplifier | Installation and User Instructions | Table of contents en | 5
Table of contents
Important safeguards ...................................................................................................................................................2
Table of contents ...........................................................................................................................................................5
2.1The Plena product range .......................................................................................................................................................9
2.2Contents of box .......................................................................................................................................................................9
3.1Unpack unit ............................................................................................................................................................................15
3.2Install unit in rack (optional) ............................................................................................................................................... 15
3.4Connect unit to mains ......................................................................................................................................................... 15
4.Connections and settings ........................................................................................................................................ 17
4.2.2Call only ............................................................................................................................................................................ 22
4.2.3Music only ........................................................................................................................................................................22
4.3.2Pin settings and labelling ..............................................................................................................................................26
Bosch Security Systems | 2007-12 | PLE-1MA030-US, PLE-1MA060-US, PLE-1MA120-US en
Page 6
Plena Mixer Amplifier | Installation and User Instructions | Table of contents en | 6
5.1Switch on and off ................................................................................................................................................................. 27
5.1.1Switch on .........................................................................................................................................................................27
5.1.2Switch off .........................................................................................................................................................................27
5.3.2Volume control ................................................................................................................................................................28
5.4Tone control .......................................................................................................................................................................... 28
5.5.1Master volume control ...................................................................................................................................................28
6.Technical data ............................................................................................................................................................. 29
6.1.1Mains power supply .......................................................................................................................................................29
6.1.4RJ-45 input 1 x ................................................................................................................................................................29
6.1.5Mic/line input 4 x ............................................................................................................................................................. 29
6.1.7Emergency / telephone 1 x ..........................................................................................................................................30
6.1.8Master/music output 1 x ...............................................................................................................................................30
6.1.9Loudspeaker outputs 70 V ...........................................................................................................................................30
Bosch Security Systems | 2007-12 | PLE-1MA030-US, PLE-1MA060-US, PLE-1MA120-US en
Page 7
Plena Mixer Amplifier | Installation and User Instructions | Introduction en | 7
1Introduction
1.1 Purpose
The purpose of these Installation and User Instructions
is to provide information required for installing,
configuring and operating a Plena Mixer Amplifier.
1.2 Digital document
These Installation and User Instructions are also
available as a digital document in the Adobe Portable
Document Format (PDF).
1.3 Intended audience
These Installation and User Instructions are intended
for installers and users of a Plena system.
1.4 Related documentation
Safety Instructions (9922 141 1036x).
1.5 Alerts
Four types of alerts are used in this manual. The alert
type is closely related to the effect that may be caused if
it is not observed. These alerts - from least severe effect
to most severe effect - are:
•Note
Alert containing additional information. Usually, not
observing a note alert does not result in damage to
the equipment or personal injuries.
•Caution
The equipment can be damaged if the alert is not
observed.
•War ning
Persons can be (severely) injured, or the equipment
can be seriously damaged, if the alert is not
observed.
•Danger
Not observing the alert can result in death.
1.6 Icons
1.6.1Note icons
The icons used in combination with Notes provide extra
information about the Note. See the following
examples:
Note
General icon for notes.
Note
Consult the indicated source of information.
1.6.2Caution, Warning, and Danger
icons
The icons used in combination with Caution, Warnings,
and Dangers indicate the type of hazard present. See the
following examples:
Caution, Warning, Danger
General icon for Cautions, Warnings and
Dangers.
Caution, Warning, Danger
Icon for risk of electric shock.
Caution, Warning, Danger
Icon for risk of electrostatic discharge.
Bosch Security Systems | 2007-12 | PLE-1MA030-US, PLE-1MA060-US, PLE-1MA120-US en
Page 8
Plena Mixer Amplifier | Installation and User Instructions | Introduction en | 8
1.7 Conversion tables
In this manual, SI units are used to express lengths,
masses, temperatures etc. These can be converted to
non-metric units using the following information.
table 1.1: Conversion of units of length
1 in =25.4 mm1 mm =0.03937 in
1 in =2.54 cm1 cm =0.3937 in
1 ft =0.3048 m1 m =3.281 ft
1 mi =1.609 km1 km =0.622 mi
table 1.2: Conversion of units of mass
1 lb =0.4536 kg1 kg =2,2046 lb
table 1.3: Conversion of units of pressure
1 psi =68.95 hPa1 hPa =0.0145 psi
Note
1 hPa = 1 mbar.
table 1.4: Conversion of units of temperature
° F = 9 . ( ° C + 32)° C = 5 . ( ° F 32)
° F = 5° C = 9
Bosch Security Systems | 2007-12 | PLE-1MA030-US, PLE-1MA060-US, PLE-1MA120-US en
Page 9
Plena Mixer Amplifier | Installation and User Instructions | Description en | 9
2Description
2.1 The Plena product range
The Plena Mixer Amplifier is part of the Plena product
range. Plena provides public address solutions for places
where people gather to work, worship, trade, or relax. It
is a family of system elements that are combined to
create public address systems tailored for virtually any
application
The Plena product range includes:
•mixers
•preamplifiers
•power amplifiers
•a music source unit
•a digital message manager
•a feedback suppressor
•call stations
•an All-in-One system
•a voice alarm system
•a timer
•a charger
•a loop amplifier
The various elements are designed to complement each
other thanks to matched acoustical, electrical and
mechanical specifications.
The volume of each microphone/line signal can be
individually adjusted to obtain the required mix; the
mixed output is controlled via the master volume
control and separate high/low tone controls.
The unit is easy to use, and provides a crisp call or clear
music. The amplifier also has enhanced features such as
ducking level control, priority, labelling, and setting
indicators.
All Microphone/line inputs can be switched between
microphone level and line level sensitivity. The inputs
are balanced but can also be used unbalanced. Phantom
power can be selected via a DIP switch to provide
power to condenser microphones. Input channels 1
and 2 can take priority over all other microphone and
music inputs:
•Input 1 can be activated by contact closure on a PTT
(push to talk). A chime can be configured to precede
an announcement.
•Input 2 can be switched automatically if a signal is
available at the input, for example, if someone
speaks into the microphone (VOX activation).
A telephone/70 V emergency input with VOX
activation is also provided for easy integration with
another PA system or a telephone paging system. It has
its own volume control and overrides all other inputs,
including the call station and inputs 1 and 2.
2.2 Contents of box
The packaging box contains the following contents:
•PLE-1MA030-US, PLE-1MA060-US, or
PLE-1MA120
•Labels and colored pins for indicating favorite
settings
•Power cord
•Plena Bonus CD
•Mounting brackets (LBC 1901/00)
2.3 The Plena Mixer Amplifier
The Plena Mixer Amplifier is a high performance,
professional public address unit for mixing up to four
separate microphone/line signals, and any one of three
separate music signals. For a schematic overview of the
Plena Mixer Amplifier, see figure 2.1 on the next page.
Bosch Security Systems | 2007-12 | PLE-1MA030-US, PLE-1MA060-US, PLE-1MA120-US en
The unit also has a line output to add amplifiers for
larger systems that require more output power. This
output can be switched to music only, for example, so
that music on hold can be provided for the telephone
system.
Users can create custom labels for inputs and music
sources. These labels can be attached to the special
holders at the front of the mixer amplifier. Colored pins
can also be inserted at various positions around the
volume and tone dial controls to indicate favorite
settings for a particular application.
Page 10
Plena Mixer Amplifier | Installation and User Instructions | Description en | 10
An LED meter monitors the master output before the
zone selection. This signal is also present on the
headphone connector below the output meter. For
total reliability and ease of use, a limiter is integrated
into the output stage to restrict output if the user
applies too much signal.
70V
0
LINE
1(disc)
2(radio)
3(aux)
LINE
LINE/MIC
LINE/MIC
LINE
/MIC
Powe r
/MIC
Ph antom
PTT
ducking
DIP
115V, 23 0 V
DIP drive
201
figure 2.1: Schematic overview of the Plena Mixer Amplifier
Music/Line
Bal. output
Amplifier
Click
sup pr essi on
70V
8Ohm
0
0
Call only 70V
70V
00
8Ohm
Bosch Security Systems | 2007-12 | PLE-1MA030-US, PLE-1MA060-US, PLE-1MA120-US en
Page 11
Plena Mixer Amplifier | Installation and User Instructions | Description en | 11
2.4 Controls, connectors and
indicators
Note
2.4.1Front panel
See figure 2.2 for an overview of the controls and
indicators.
1 Power button.
2 Label holder for user-defined description of
microphone/line inputs - custom labels can be
created by user.
3 Label holder for user-defined description of music
sources - custom labels can be created by user.
4 Master high tone control.
5 Master volume control - controls all inputs except
8 Music source selector (for music inputs 1, 2, and 3).
9 Music source volume control.
10 Master low tone control.
11 Air inlet holes.
2.4.2Plena PLE-WP2Z3S wall panel
The optional Plena PLE-WP2Z3S wall panel can be
used to remotely control the unit from a maximum of
four remote locations. The appearance of the wall panel
is matched to the Bosch loudspeaker volume controls.
The music source can be easily changed. The status of
each music source is indicated by an LED.
A standard CAT 5 cable is used to connect the wall
panel to the mixer-amplifier. The maximum distance is
200 m. Please refer to the relevant datasheet for more
information.
Users can create custom labels for the
microphone/line inputs and description of the
music sources. These labels can be attached to
the mixer amplifier at position numbers 2 and 3
(see figure 2.2). Colored pins can also be
inserted at various positions around the dial
controls to indicate the favorite settings for a
particular application. For more information on
inserting and removing pins, see section 4.3.2.
Note
Do not obstruct the airflow into the unit.
12 Headphone socket.
1
figure 2.2: Front panel
23
789101211
456
B
Bosch Security Systems | 2007-12 | PLE-1MA030-US, PLE-1MA060-US, PLE-1MA120-US en
Page 12
Plena Mixer Amplifier | Installation and User Instructions | Description en | 12
2.4.3Rear panel
See figure 2.3 for an overview of the connectors and
switches:
1 Tel. emergency/70V input, Euro style pluggable
screw terminal connector - VOX function. This input
has highest priority.
2 Telephone emergency/70V input volume control -
control range -25 dB to 0dB (see number 1).
3 Remote control wall-panel-input, RJ-45 connector.
Wall panel incorporates: BGM source selection, and
zone on/off control.
4 Ducking level control for microphone/line inputs 1
and 2.
5 Music input (number 1 disc), 2x RCA/cinch
connectors. Stereo, summed mono.
6 Music input (number 2 radio), 2x RCA/cinch
connectors. Stereo, summed mono.
7 Music input (number 3 auxiliary), 2x RCA/cinch
connectors. Stereo, summed mono.
8 Music master output, XLR connector - switch setting
for line out, or music only. This output can carry out
either music only, or the master output. For more
information, see chapter 4.2.3.
9 Cooling fan (PLE-1MA120 only).
15 Microphone/line 4 input, Euro style pluggable screw
terminal connector - DIP switch settings for mic/line,
and phantom power
(see number 14).
Always allow adequate space at the rear of the
unit for ventilation.
10 Microphone/line 1 input with trigger, Euro style
pluggable screw terminal connector - DIP switch
settings for: chime, PTT (push to talk), mic/line,
speech filter, and phantom power (see number 11).
11 DIP switch for microphone/line 1 and microphone/
line 2 (see numbers 10 and 12 respectively).
12 Microphone/line 2 input, Euro style pluggable screw
terminal connector - DIP switch settings for speech
filter, mic/line, VOX, and phantom power (see
number 11).
13 Microphone/line 3 input, Euro style pluggable screw
terminal connector - DIP switch settings for mic/line,
and phantom power (see number 14).
14 DIP switch for microphone/line 3 and microphone/
line 4 (see numbers 13 and 15 respectively).
Bosch Security Systems | 2007-12 | PLE-1MA030-US, PLE-1MA060-US, PLE-1MA120-US en
Page 13
Plena Mixer Amplifier | Installation and User Instructions | Description en | 13
943567218
Call
Trigger
Gnd
Telephone/Emergency Input
Gnd
0100V
Chime Ducking
figure 2.3: Rear panel
h
Off
Line
Off
Speec
Speech
Off
Off
Line
Chime
Flat
PTT
Mic
Flat
Phantom
Vox
Mic
PLE-2CS
MuteMix
Wall Panel
1(disc) 2(radio) 3(aux) Insert
Mic Line
Phantom Off
Mic Line
In
Music
Line
Only
Out
Out
Off
Mic Line
Phantom
Mic Line
Output
Zone 1 OutZone 2 Out
PLE-10M2-EU
2 Channel Mixer
115/230V~, 50/60Hz
S/N
Design & Quality
The Netherlands
F01U.066.938
8900 192 21001
Rated input
power: 40VA
Line fuse
T1L250V for 230V
T1.6L250V for 115V
Apparatus delivered
connected for 230V~
19181716141311121510
Bosch Security Systems | 2007-12 | PLE-1MA030-US, PLE-1MA060-US, PLE-1MA120-US en
Page 14
Plena Mixer Amplifier | Installation and User Instructions | Description en | 14
Intentionally left blank
Bosch Security Systems | 2007-12 | PLE-1MA030-US, PLE-1MA060-US, PLE-1MA120-US en
Page 15
Plena Mixer Amplifier | Installation and User Instructions | Installation en | 15
3Installation
3.1 Unpack unit
1 Remove the unit from the box, and discard the
packaging material according to local regulations.
2 Use your fingernails to carefully peel off the
protective plastic film from the label holders. Do not
use sharp or pointed objects.
3.2 Install unit in rack (optional)
The Plena Mixer Amplifier is intended for tabletop use,
but you can also mount the unit in a 19" rack (see
figure 3.1).
If you mount the unit in a rack, you must:
•ensure that it does not exceed the overheating
temperature (45 °C ambient).
•use the included Bosch mounting brackets
(LBC 1901/00).
•remove the 4 feet from the bottom of the unit.
3.3 Check settings/connections
1 Connect any additional equipment (see section 4.1
and 4.2).
2 Check the settings (see section 4.3).
3.4 Connect unit to mains
Caution
Potential equipment damage. Before
connecting power, always check the voltage
indicator plate at the rear of the unit.
1 Make sure the power switch on the front of the unit
is set to Off.
2 Connect the power cord to the mains connector and
plug it into the mains outlet.
1
figure 3.1: Installing the unit in a rack
B
figure 3.2: Power connection and voltage selector
Bosch Security Systems | 2007-12 | PLE-1MA030-US, PLE-1MA060-US, PLE-1MA120-US en
Page 16
Plena Mixer Amplifier | Installation and User Instructions | Installation en | 16
Intentionally left blank
Bosch Security Systems | 2007-12 | PLE-1MA030-US, PLE-1MA060-US, PLE-1MA120-US en
Page 17
Plena Mixer Amplifier | Installation and User Instructions | Connections and settings en | 17
4Connections and settings
4.1 Connecting inputs
4.1.1Priority microphone (input 1)
The priority microphone (or a generic call station) that
can be used with push to talk (PTT) should be
connected to “microphone/line 1 input”. The PTT
mode can be activated by setting the DIP switch (11) at
the rear of the unit. Microphone/line 1 input has
priority over all other microphone/line inputs.
If, however, the “Tel. emergency/70V input” receives a
signal, all inputs including microphone/line 1 input will
be overruled.
The microphone/line 1 input has a Euro style pluggable
screw terminal connector. This Euro style pluggable
screw terminal connector has a trigger input, which can
be used in combination with the Euro connector.
The priority microphone can be connected to the
microphone/line 1 input with trigger as follows:
•Euro connector with trigger. See figure 4.1.
•Euro connector only (without trigger).
Set the DIP switch settings for microphone/line 1 with
trigger, as required. See section 4.3.
Note
When connecting an unbalanced line level
(200 mV) signal to the microphone/line input,
connect it as follows: Signal to +, connect to and GND to ground.
figure 4.1: Euro connector with trigger
Bosch Security Systems | 2007-12 | PLE-1MA030-US, PLE-1MA060-US, PLE-1MA120-US en
Page 18
Plena Mixer Amplifier | Installation and User Instructions | Connections and settings en | 18
4.1.2Secondary microphone (input 2)
Connect a secondary microphone to “microphone/line
input 2”. See figure 4.2.
Microphone/line input 2 has a DIP switch (11) at the
rear of the unit for setting the VOX mode. If the DIP
switch is set to VOX, the microphone/line input will
automatically be switched when a signal is sensed at the
microphone/line 2 input. For example, when someone
speaks into the microphone, other sound will either be
muted or ducked, depending on the setting of the
ducking level control at the rear of the unit. See
section 4.3.
The Tel. emergency/70V input and Microphone/line
input 1 all have priority over the Microphone/line
input 2. Therefore, any signal received on any one of
these inputs will always be heard regardless of the
ducking level control setting for Microphone/line
input 2.
Set the DIP switch settings for microphone/line input 2
as required. See section 4.3.
4.1.3Additional microphones
(inputs 3 and 4)
Connect additional microphones to microphone/line
inputs 3 and 4 as required. See figure 4.2. These
microphones will mix with the background music.
Set the DIP switch settings for microphone/lines 3 and
4, as required. See section 4.3.
figure 4.2: Connecting microphone inputs
Bosch Security Systems | 2007-12 | PLE-1MA030-US, PLE-1MA060-US, PLE-1MA120-US en
Page 19
Plena Mixer Amplifier | Installation and User Instructions | Connections and settings en | 19
4.1.4Emergency inputs
The Tel. emergency/70V input, with VOX functionality,
is used for receiving emergency announcements or
signals (such as a fire alarm). This input has absolute
priority, and will overrule all inputs when an emergency
announcement or signal is received.
Either a telephone line or a 70 V input signal can be
connected to the Euro style pluggable screw terminal
connector (1) at the rear of the unit. See section 4.1.4.1
and section 4.1.4.2.
Caution
Never connect telephone lines and a 70 V signal
to the Euro style connector at the same time.
To adjust the volume of the emergency announcement
or signal, turn the rotary dial (2) at the rear of the unit.
For safety reasons, the volume of the emergency
announcement or signal cannot be set to zero.
4.1.4.1Connecting 70 Volt input signal
Connect the 70 Volt input signal as shown in
figure 4.3.
Note
Tel. emergency input does not mute the
incoming signal so that an incoming pilot tone
will be fed to the zone outputs. With this feature
it is possible to use the mixer amplifier in a
Bosch Voice Alarm System when using end of
line boards (PLN-1EOL).
The signal that is delivered to the unit should be
quiet when a call is not made. The pilot tone and
frequencies below 300 Hz are filtered from the
trigger signal so that the input will not trigger
from a pilot tone or low frequency rumble.
The master volume control setting (5) does not influence
the volume setting of the emergency announcement or
signal.
figure 4.3: Connecting 70 Volt input signal
Bosch Security Systems | 2007-12 | PLE-1MA030-US, PLE-1MA060-US, PLE-1MA120-US en
Page 20
Plena Mixer Amplifier | Installation and User Instructions | Connections and settings en | 20
4.1.4.2Connecting telephone lines
Connect the telephone lines as shown in figure 4.4.
Caution
A connection to a telephone network must
always be made via a telephone coupler that
provides adequate isolation between the
telephone network (PBX) and the Plena system.
The telephone coupler must also meet all
relevant requirements for this type of
communication equipment as imposed by law
and/or responsible telecommunication
organizations in the country of use. Never try to
make a direct connection between the telephone
network and the mixer amplifier.
figure 4.4: Connecting emergency telephone lines
Bosch Security Systems | 2007-12 | PLE-1MA030-US, PLE-1MA060-US, PLE-1MA120-US en
Page 21
Plena Mixer Amplifier | Installation and User Instructions | Connections and settings en | 21
4.1.5Music source inputs
When using a CD player, tuner or other auxiliary
device for background music, connect the line-out
connectors of the music source to the appropriate line-in
connectors of the mixer amplifier.
figure 4.5: Connecting music source inputs
Bosch Security Systems | 2007-12 | PLE-1MA030-US, PLE-1MA060-US, PLE-1MA120-US en
Page 22
Plena Mixer Amplifier | Installation and User Instructions | Connections and settings en | 22
4.2 Connecting outputs
4.2.1Main output
Connect speakers to the 70 V or 4 Ohm terminal on the
Euro style pluggable screw terminal connector (16) at
the rear of the unit.
Also see section 4.2.4 “Connecting speakers”.
4.2.2Call only
Connect speakers to the 70 V terminal on the Euro style
pluggable screw terminal connector (16) at the rear of
the unit.
Also see section 4.2.4 “Connecting speakers”.
4.2.3Music only
Use the music master output connector (8) to provide a
dedicated music out source for another device. For
example, the music master output can be connected to a
telephone coupler, so that callers can listen to music
when they are put on hold (see figure 4.6).
To select the dedicated music out source, set the internal
jumper. Only the music inputs (5, 6, and 7) will be
audible. All other inputs, including the Tel.
emergency/70V input will not be sent to this output.
To hear all mixed inputs (microphone/line, emergency,
and music) set the internal jumper.
figure 4.6: Connecting music source inputs
Bosch Security Systems | 2007-12 | PLE-1MA030-US, PLE-1MA060-US, PLE-1MA120-US en
Page 23
Plena Mixer Amplifier | Installation and User Instructions | Connections and settings en | 23
4.2.4Connecting speakers
4.2.4.1Constant voltage loudspeakers
figure 4.7: Connecting speakers
The mixer amplifier can drive 70 V constant voltage
loudspeakers.
Connect the loudspeakers in parallel and check the
loudspeaker polarity for in-phase connection. The
summed loudspeaker power should not exceed the
rated amplifier output power.
4.2.4.2Low impedance loudspeakers
figure 4.8: Connecting speakers
Connect low impedance loudspeakers to the 4 Ohm/0
terminals. This output can deliver the rated output
power into an 4 Ohm load. Connect multiple
loudspeakers in a series/parallel-arrangement to make
the combined impedance 4 Ohm or higher. Check the
loudspeaker polarity for in-phase connection.
You can use the Call Only output for 3-wire remote
volume control override. You can also use this output as
an extra zone where announcements can be heard, but
not music.
Bosch Security Systems | 2007-12 | PLE-1MA030-US, PLE-1MA060-US, PLE-1MA120-US en
Page 24
Plena Mixer Amplifier | Installation and User Instructions | Connections and settings en | 24
4.3 Unit settings
4.3.1Rear panel settings
The unit can be quickly set-up for operation by setting
the following controls at the rear of the unit:
•DIP switches
•Rotary dials.
See the following tables for an overview of the settings
and typical examples of their use.
table 4.1: DIP switch settings
DIP switchOnOffTypical example (On)
Chime
(mic/line 1)
PTT “Push to talk”
(mic/line 1 only)
LineInput signal from line.Input signal from
Speech filterEnhances clarity of speech, by
Phantom powerProvides power to condenser
VOX
(mic/line 2 only)
Chime will be sounded at the
beginning of an announcement.
This input is muted when the push
to talk contact is open. When the
push to talk contact is closed:
•this input is available for
speech.
•a chime will sound, if selected.
•the music and other mic/line
inputs will be reduced in
volume to the level set by the
ducking level control knob.
cutting-off the lower frequencies
of the signal.
microphones.
Temporarily suppresses the
background music to an
adjustable “ducking level” (see
table 4.2) while you speak into the
microphone. The VOX mode is
normally used with hand-held
microphones such as the
LBC 2900/15. Background music
and announcements will be heard
in the selected zones. A chime is
not available in this mode.
Chime will not be sounded
at the beginning of an
announcement.
Push to talk off. The signal
will be mixed with the other
mic/line signals.
Microphone 1 will mix with
the background music or
the other microphones in
the selected zones.
microphone.
Speech filter inactive.Use for announcements
Phantom power
unavailable.
VOX inactive.
Microphone 2 will mix with
the background music or
the other microphones in
the selected zones.
Announcement of train
departure time.
Users can have private
conversations during live
broadcasts (for example,
with an all call
call-station, such as the
PLE-1CS).
Depends on set-up.
Enable phantom power if
you use electret or
condenser microphones.
Use to make casual
announcements (such as
announcing the winner of
a competition) while
temporarily suppressing
the background music to
an adjustable ducking
level.
Bosch Security Systems | 2007-12 | PLE-1MA030-US, PLE-1MA060-US, PLE-1MA120-US en
Page 25
Plena Mixer Amplifier | Installation and User Instructions | Connections and settings en | 25
table 4.2: Rotary controls
Rotary controlEffectTypical example
Ducking level controlSets the required ducking level when VOX and/or
push to talk is active (see table 4.1). When the
ducking level is set to mute, the music volume will be
fully attenuated; when the ducking level is set to mix,
Set the ducking level control to
mute if you want the
announcement to be heard without
background music.
both music and speech inputs can be heard - music
and speech will be mixed. When ducking the music
input is ducked (attenuated), the microphone/line
inputs are always muted when a call is made.
Te l ep h on e
emergency/70V
volume control
Attenuates the emergency announcement or signal.
Control range from -25 dB to 0 dB. For safety
reasons, the volume of the emergency
announcement or signal cannot be fully set to zero.
Set the volume of the emergency
announcement to a higher level
when the system is being used in
large open areas.
Note
When PTT or VOX are selected, the ducking
control controls between 3 dB attenuation (very
little ducking) to –∞ dB (muted).
When ducking, the music is also present on the
Call only output. If you do not want this, set the
ducking control to mute.
Bosch Security Systems | 2007-12 | PLE-1MA030-US, PLE-1MA060-US, PLE-1MA120-US en
Page 26
Plena Mixer Amplifier | Installation and User Instructions | Connections and settings en | 26
4.3.2Pin settings and labelling
Users can create custom labels for the: microphone/line
inputs, description of the music sources, and audio
output zones 1 and 2. These labels can be attached to
the mixer amplifier at position numbers 2 and 3 (see
figure 2.2). Colored pins can also be inserted at various
positions around the dial controls to indicate the favorite
settings for a particular application.
The pins are engineered in such a way that they cannot
be taken out by hand. This is to prevent tampering. The
pins are intended to be inserted once, during installation
of the unit. The silver pins should be used to indicate
the preferred settings of the unit. The red pins can
optionally be used to indicate the maximum setting of a
knob.
If these settings have to be changed, use a pair of softtipped pliers to carefully remove the pins. If you do not
have a pair of soft-tipped pliers, you can use ordinary
pliers instead, but first place some plastic tape on the
tips of the pliers to prevent damaging the front of the
unit.
To remove the clear plastic covers in front of the labels:
1 Carefully insert a small screwdriver into the cut-out
at the bottom of the plastic cover.
2 Gently lift the cover, and bend it in the middle. Take
care not to force the cover or the front panel.
To reattach the plastic covers with paper labels:
1 Insert the paper label into the holder at the front of
the unit.
2 Pick up the cover, and then bend it slightly in the
middle by hand.
3 Fit the cover into the slot at the front of the unit, and
then gently release the cover, making sure that the
paper label stays in place.
Bosch Security Systems | 2007-12 | PLE-1MA030-US, PLE-1MA060-US, PLE-1MA120-US en
Page 27
Plena Mixer Amplifier | Installation and User Instructions | Operation en | 27
5Operation
5.1 Switch on and off
5.1.1Switch on
Caution
Potential equipment damage. Before applying
power, always check the voltage indicator plate
at the rear of the unit.
1 Set the power button (1) on the front of the unit to
On - pushed in (see figure 5.1).
5.1.2Switch off
Set the power button (1) on the front of the unit to Off popped out (see figure 5.1).
1
figure 5.1: Front panel
23
789101211
456
B
Bosch Security Systems | 2007-12 | PLE-1MA030-US, PLE-1MA060-US, PLE-1MA120-US en
Page 28
Plena Mixer Amplifier | Installation and User Instructions | Operation en | 28
5.2 Microphone/line controls
Note
Users can create custom labels for the
microphone/line inputs and description of the
music sources. These labels can be attached to
the mixer amplifier at position numbers 2 and 3
(see figure 5.1). Colored pins can also be
inserted at various positions around the dial
controls to indicate the favorite settings for a
particular application.
Use the volume controls (7) to individually control the
sound level of microphone/line inputs 1 through 4.
5.3 Music controls
5.3.1Source selection
Use the music source selector (8) to select one of the
connected music sources.
5.5 Output controls
5.5.1Master volume control
Use the master volume control dial (5) to collectively
control the sound level of all outputs, except the
emergency announcement/signal.
5.3.2Volume control
Use the music source volume control (9) to control the
sound level of the selected music source.
5.4 Tone control
The tone controls are not standard bass and
treble controls: they can be used as a traditional tone
control with high and low control, but also have a
powerful contour that addresses problems found in real
situations.
The tone control for the low frequencies boosts deep
bass first without making the sound boomy, and cuts
rumble without loosing warmth in the low frequencies.
Use the Hi (high) and Lo (low) tone controls (see
figure 5.1, numbers 4 and 10) to change the tone.
Bosch Security Systems | 2007-12 | PLE-1MA030-US, PLE-1MA060-US, PLE-1MA120-US en
Page 29
Plena Mixer Amplifier | Installation and User Instructions | Technical data en | 29
6Technical data
6.1 Electrical
6.1.1Mains power supply
Voltage
230 VAC, ±10%, 50/60 Hz
Inrush Current PLE-1MA030-US
4.5 A
Inrush Current PLE-1MA060-US
5 A
Inrush Current PLE-1MA120-US
10 A
6.1.2Power consumption
PLE-1MA030-US
100 VA
PLE-1MA060-US
200 VA
PLE-1MA120-US
400 VA
6.1.3Performance
Frequency response
50 Hz to 20 kHz (+1/-3 dB @ -10 dB ref. rated
output)
Distortion
<1% @ rated output power, 1 kHz
Bass Control
Max -12/+12 dB (frequency is level dependent)
Treble Control
Max -12/+12 dB (frequency is level dependent)
6.1.5Mic/line input 4 x
Input 1 (Push-to-talk contact with ducking
functionality)
5-pin Euro style, balanced, phantom
Input 2-4 (VOX with ducking functionality on input
2)
5-pin Euro style, balanced, phantom
Sensitivity
1 mV (mic); 200 mV (line)
Vox sensitivity
-15 dB (attack time 20 ms; release time 4 s)
Impedance
>1 kohm (mic); >5 kohm (line)
S/N (flat at max volume)
63 dB (mic); >70 dB (line)
S/N (flat at min volume/muted)
>75 dB
Dynamic range
100 d B
S/N (flat at max volume)
>63 dB (mic); >70 dB (line)
S/N (flat at min volume/muted)
>75 dB
CMRR
>40 dB (50 Hz to 20 kHz)
Headroom
>25 dB
Speech filter
-3 dB @ 315 Hz, high-pass, 6 dB/oct
Phantom power supply
16 V via 1.2 kohm (mic)
6.1.4RJ-45 input 1 x
Wall panel input
For PLE-WP3S2Z
Bosch Security Systems | 2007-12 | PLE-1MA030-US, PLE-1MA060-US, PLE-1MA120-US en
Page 30
Plena Mixer Amplifier | Installation and User Instructions | Technical data en | 30
6.1.6Music inputs 3x
Connector
Cinch, stereo converted to mono
Sensitivity
200 mV
Impedance
22 kohm
S/N (flat at max volume)
>70 dB
S/N (flat at min volume/muted)
>75 dB
Headroom
>25 dB
6.1.10Loudspeaker output 4 Ohm*
Connector
Screw terminal, floating
PLE-1MA030-US
16 V ( 3 0 W )
PLE-1MA060-US
22 V (60 W)
PLE-1MA120-US
31 V (120 W)
6.2 Mechanical
6.1.7Emergency / telephone 1 x
Connector
7-pin, Euro style pluggable screw connector
Sensitivity tel
100 mV – 1 V adjustable
Sensitivity 70V
10 V – 70 V adjustable
Impedance
>10 kohm
S/N (flat at max volume)
>65 dB
VOX
threshold 50 mV; attack time 150 ms; release time 2 s
6.1.8Master/music output 1 x
Connector
5-pin Euro style pluggable screw connector, balanced
Nominal level
1 V
Impedance
<100 ohm
Dimensions (H x W x D)
100 x 430 x 270 mm (19" wide, 2U high)
Mounting
Stand-alone, 19" rack
Color
Charcoal
Weight (PLE-1MA030-US)
Approx. 5 kg
Weight (PLE-1MA060-US)
Approx. 8.5 kg
Weight (PLE-1MA120-US)
Approx. 10.5 kg
6.3 Environmental
Operating temperature
-10 to +45 ºC
Storage temperature
-40 to +70 ºC
Relative humidity
<95%
Acoustic noise level of fan (PLE-1MA120-US)
<33 dB SPL @ 1 m
6.1.9Loudspeaker outputs 70 V
Connector
Screw connector, floating
Max / rated PLE-1MA030-US
45 W / 30 W
Max / rated PLE-1MA060-US
90 W / 60 W
Max / rated PLE-1MA120-US
180 W / 120 W
Bosch Security Systems | 2007-12 | PLE-1MA030-US, PLE-1MA060-US, PLE-1MA120-US en