Bosch OD850-F1 Specsheet

Intrusion Alarm Systems | OD850 Series Outdoor TriTech Detectors
OD850 Series Outdoor TriTech Detectors
www.boschsecurity.com
u Motion Analyzer II PIR signal processing
u Linear travel distance (LTD) microwave signal
processing
The OD850 Series TriTech detectors are for use outdoors and in other harsh environments. They use a combination of passive- infrared (PIR) and microwave detection with advanced signal processing.
System overview
The detectors process PIR signals with Motion Analyzer II signal processing and microwave signals with Linear Travel Distance (LTD) signal processing. The detectors can distinguish between small, repetitive motions such as tree limbs moving in the wind and the more purposeful motions of intruders. These advanced processing techniques and the detectors' mechanical design combine to provide superior performance in a wide range of weather conditions.
Functions
Motion Analyzer II Processing
This PIR signal processor uses multiple thresholds and timing windows to analyze timing, amplitude, duration, and polarity of signals to make an alarm decision. Extreme levels of thermal and illumination disturbances caused by hot and cold drafts, sunlight, or lightning do not cause an alarm.
u Timed relay output adjustable from two sec to 10
min
u AND/OR mode
LTD Microwave Signal Processing
This microwave signal processor measures the linear travel distance of a target to make an alarm decision. It eliminates alarms for objects that move but do not travel, such as tree limbs and hanging signs.
Two Sensitivity Levels
The detectors have two user-selectable PIR sensitivity settings: Standard sensitivity is the recommended setting for a minimum of false alarms. The detector tolerates environment extremes on this setting. Intermediate sensitivity is the recommended setting for any location where an intruder is expected to cover only a small portion of the protected area. The detector tolerates normal environments on this setting. This setting identifies intruders more quickly, but may produce more false alarms.
Adjustable Timed Relay Output
In addition to an alarm relay, there is a Form C, unsupervised, timed relay contact that alternates state 1 sec after an alarm and follows a user-selectable timer. The time expires at the set time after the last alarm (it resets on each new alarm).
0 ft
0 m
0 ft
7.5 m
25 ft
25 ft
50 ft
7.5 m
15 m
0 m
0 m
0 ft
0 ft
0 m
3 m
15 m
50 ft
10 ft
2 | OD850 Series Outdoor TriTech Detectors
AND/OR Mode
This DIP-switch setting specifies whether the detector reports alarm situations in the AND mode (when both technologies simultaneously sense an alarm condition) or in the OR mode (when either the PIR or microwave technology senses an alarm state). OR mode provides faster detection in some conditions as the detector activates the alarm relay based on a single technology input.
LEDs
The high-efficiency LEDs (one red and one green) use the same technology as traffic lights to make them visible in sunlight. A DIP-switch setting allows the user to disable these LEDs during standard operation to save power.
Draft and Insect Immunity
The sealed optical chamber prevents drafts and insects from affecting the detector.
Certifications and approvals
Australia C-tick
Europe IEC IP=54 per IEC 60529
OD850-F2 only: Complies with EN50131-1 grade 2
Installation/configuration notes
Top View Standard Broad Coverage: 15 m x 15 m (50 ft x 50 ft)
Region Certification
Europe CE 89/336/EEC, EN55022: 1998
CE 2004/108/EC EMC Directive (EMC);
Belgium INCERT B-509-0038
Russia GOST OD850-F1 only: DE.AE63.B03457
USA UL OD850-F1 only: ANSR: Intrusion Detec-
FCC OD850-F1 only: ESVOD850-F1
Canada ULC ANSR7.BP1448 Intrusion-detection
China CCC OD850-F1-CHI only:
Brazil ANATEL OD850-F1 only: 0873-03-1855
Singapore iDA OD850-F1 only: #LPREQ-S0155-2004
+A1:2000 +A2:2003, EN50130-4: 1996 +A1:1998 +A2:2003, EN61000-3-3: 1995 +A1:2001, EN61000-4-2: 1995 +A1:1998 +A2:2001, EN61000-4-3: 2002 +A1:2002, EN61000-4-4: 1995 +A1:2000 +A2:2001, EN61000-4-5: 1995 +A1:2001, EN61000-4-6: 1996 +A1:2001, EN61000-4-11" 1994 +A1:2001, EN300 440-1 V1.3.1: 2001-09, EN300 440-2 V1.1.1: 2001-09
2006/95/EC Low-Voltage Directive (LVD); 1999/5/EC Radio Equipment and Telecommunications Terminal Equip­ment (R&TTE) [OD850-F1] [OD850-F2]
tion Units (UL639), ANSR7: Intrusion Detection Units Certified for Canada (ULC-S306)
Units Certified for Canada
2009031901000551
Side View Standard Broad Coverage: 15 m x 15 m (50 ft x 50 ft)
Mounting Considerations
• Wall Mounting: The OD850 detectors can be mounted directly on a wall or on the supplied B335 Swivel Mount Bracket. Alternatively, they can be mounted directly on a standard rectangular electrical box. The detectors should be mounted 2.1 m to 2.7 m (7 ft to 9 ft) above the ground. The recommended height is
2.1 m (7 ft); leveled both horizontally and vertically.
• Ceiling Mounting: The detectors can be mounted on a ceiling using the optional B338 Ceiling-Mount Bracket.
Power Considerations
• Power Limits: Input power must be provided by an Approved Limited Power Source. All outputs must be connected to SELV (safety extra-low voltage) circuits only.
• Standby Power: This detector has no internal standby battery. For UL Listed product installations, 4 hr
(248 mAh) of standby power must be supplied by the control unit or by a UL Listed burglary power supply.
Technical specifications
Enclosure Design
Dimensions: 16.5 cm x 8.25 cm x 6.35 cm
(6.5 in. x 3.25 in. x 2.5 in.)
Material: Polycarbonate