Bosch Eco26+ Installation Manual

SAR8854
Rev. 07/08
Installation Manual
Bosch Eco26
+ External Model BC2600RA
www.bosch.com.au
To be installed and serviced only by an authorised person
This appliance is not suitable for use as a pool heater
The "authorised installing person" is responsible for:
appliance.
2. Ensure unit performs to the specifications stated on the
3. Demonstrate operation of unit to
customer before leaving.
4.
customer
.
Failure to install this appliance in accordance with these installation instructions may void warranty
In the interest of continued product improvement, Bosch reserves the right to alter these specifications
without notice.
1. Correct commissioning of this
rating label.
Hand these instructions to
This appliance must be installed in accordance with the manufacturer's installation instructions, AS5601, AS/NZS3500.4, AS3000 wiring regulations and all Local Building, Water and Gas fitting regulations.
Installation Instructions
*SAR8854C*
2
Installation Instructions
Potential dangers from accidents during installation and use are divided into the following three categories. Closely observe these warnings, they are critical to your safety.
Prohibited
Disconnect Power
Earth
Be sure to do
Requests to Installers
• In order to use the water heater safely, read this installation manual carefully, and follow the installation instructions.
• Failures and damage caused by erroneous work or work not as instructed in this manual are not covered by the warranty.
• Check that the installation was done properly in accordance with this Installation Manual upon completion.
After completing installation, please either place this Installation Manual in a plastic pouch and attach it to the side of the water heater,
or hand it to the customer to retain for future reference.
WARNING: If the information in this manual is not followed exactly, a fire or explosion may result
causing property damage, personal injury or death.
Installation Manual
CONDENSING GAS WATER HEATER
Bosch Eco26+ <BC2600RA> (Outdoor Installation)
DANGER indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.
DANGER
CAUTION
WARNING
CAUTION
Robert Bosch (Australia) Pty. Ltd.
3
Installation Instructions
1.
Included Accessories
The following accessories are included with the unit. Check for any missing items before starting installation.
QtyShapePart
Tapping Screw
1
each
Part Shape Qty
5
Owner's Guide,
Installation Manual
(this document)
2.
Optional Accessories
The accessories listed below are not included with the units, but may be necessary for installation.
QtyShapePartPart Shape Qty
1
Main Controller
(YPRM67XB)
1
Bathroom Controller
(YPRS67XB)
Sub Controller
(YPRP62XB)
1
Priority
Burner on
Temp.
Bath Fill
ON/OFF
Bath Fill
Volume setting
Set Time
Press 2sec. to set time
Main Controller
YPRM67XB
Priority
Burner on
Temp.
Bath Fill
ON/OFF
Bath Fill
Priority
Call
Bathroom Controller
YPRS67XB
Priority Burner on
Hot Water Temp
Sub Controller
YPRP62XB
Hot Water Temp.
Call
ON/OFF
Maximum two Sub controllers can be used. See P.14 for details.
4
Installation Instructions
3.
Before Installation
Do Not Use Equipment for Purposes Other Than Those Specified
Do not use for other than increasing the temperature of the water supply, as unexpected accidents may occur as a result.
Check Water Supply Quality
If the water supply is hard, acidic or otherwise impure, treat the water with approved methods in order to ensure full warranty coverage.
WARNING
CAUTION
Check the Gas
Check that the data plate (located inside of front cover) or a temporary label (located on the front cover) indicates the correct type of gas.
Check that the gas supply line is sized for 178 MJ/hr for this unit.
DO NOT OPERATE WITH ANY OTHER GAS TYPE.
Check the Power
The power supply required is 240/230VAC, at 50Hz. Using the incorrect voltage may result in fire or electric shock.
Warning labels
Located on the right side of the casing -PLEASE READ THESE LABELS CAREFULLY!
Use Extreme Caution if Using With a Solar Pre-Heater
A solar transfer valve must be installed with all solar applications when using Bosch Eco 26+.
Solar systems installed without a solar transfer valve will void all Bosch warranty.
For NG Gas
MODEL BC2600RA GAS TYPE GAS CONSUMPTION HEAT OUTPUT ELECTRICAL RATING RATED POWER HOT WATER SUPPLY CAPACITY GAS PRESSURE TEST POINT
: NG : 178MJ/hr : 45.7kW : AC240/230V 50Hz : 56.0W : 26L/min RAISED 25°C : MAX : 0.73kPa
: MIN : 0.18kPa
5
Installation Instructions
4.
Choosing Installation Site
* Locate the appliance in an area where water leakage from the unit or connections will not result in
damage to the area adjacent to the appliance or to the lower floors of the structure. When such locations cannot be avoided, it is recommended that a suitable drain pan, adequately drained, be installed under the appliance. The pan must not restrict combustion air flow.
DANGER
Indoor
This water heater is for outdoor installation only. Never install it indoors. Do not enclose the termination with corrugated metal or other materials.
This will cause carbon monoxide poisoning and a potential fire hazard.
Avoid places where fires are common, such as those where petrol, benzene and adhesives are handled, or places in which corrosive gases (ammonia, chlorine, sulfur, ethylene compounds, acids) are present. May result in fire.
Avoid installation in places where dust or debris will accumulate.
Dust may block the air-supply opening, causing the performance of the device fan to drop and incomplete combustion to occur as a result.
Avoid installation in places where special chemical agents (e.g., hair spray or spray detergent) are used.
Ignition failures and malfunction may occur as a result.
Carbon Monoxide Poisoning Hazard. Do not install this water heater in a mobile home, recreation vehicle or on a boat.
Prohibited
WARNING
6
Installation Instructions
5. Installation Clearances
Before installing, check for the following:
The location of the flue terminal must comply with the clearances shown on this page. If you are unsure about clearances not indicated here, in general refer to AS5601, or your local authority. In Western Australia refer to the WA Office of Energy rules and regulations.
Flue outlet must be free from any combustible material.
WARNING
Install the water heater in a location where it is free from obstacles and stagnant air.
Consult with the customer concerning the location of installation.
Do not install the water heater near staircases or emergency exits.
Do not install the water heater where the exhaust will blow on outer
walls or material not resistant to heat. Also consider the surrounding trees and animals.
The heat and moisture from the water heater may cause discoloration of walls and resinous materials, or corrosion of aluminium materials.
Do not locate the vent termination directed towards a window or any other structure which has glass or wired glass facing the termination.
Install in a location where the exhaust gas flow will not be affected by fans or range hoods.
Take care that noise and exhaust gas will not affect neighbours.
Avoid installation where the unit will be exposed to excessive winds.
Before installing, make sure that the vent termination will have the proper
clearances according to AS5601, or your local authority.
On combustible surfaces e.g. weatherboards etc. it is not required to install a fire proof back board.
CAUTION
Prohibited
Loading...
+ 12 hidden pages