EA102A-304
Installation Instructions
EN
Receiver
EA102A-304 | Installation Instructions |
1.0 Specifications
EN | 2
1.0 Specifications
Table 1: Specifications
Enclosure
Temperature
Range
Power
RF Input
Frequency
Signal
Strength
Antenna Type
Compatibility
Available in indoor and weatherproof
outdoor enclosure
-40°C to +65°C (-40°F to +149°F)
12 VDC, 25 mA typical,
55 mA with horn sounding
304.000 MHz
Measured in 255 steps
Diversity antennas
SE2x-304 Series and SE4x-304 Series
Transmitters; EA500B Transponder with
a ROM version 4.00 or greater
Note:
The EA102A-304 is compatible only with other
“-304” equipment (such as the SE2x-304 and
SE4x-304).
Do not
install this unit in conjunction
with an EA500B Transponder with a ROM version
earlier than 4.00.
2.0 Mounting
Choose a mounting location based on the previous site
survey. Mount the receiver as close as possible to the
location found with the test receiver. Use the following
sections as a guideline for receiver mounting and
spacing.
2.1 Indoor Receiver Installation
Receiver Spacing: Receiver spacing should be no
more than 24.4 m (80 ft.) between receivers for standard
construction. Range depends on the construction of the
building. For example, a building with hollow drywall
walls may support 24.4 m (80 ft.) spacing, but a building
with steel reinforced concrete may require reduced
spacing. It is very important to maintain a consistent
spacing as this ensures optimum signal locating. The
better the receivers can detect a transmitted signal, the
more accurate the locating.
Mounting Height: Mound receivers 1.5 m to 1.8 m
(5 ft. to 6 ft.) from the floor. Maintain a consistent
mounting height to ensure optimum signal locating. Do
not place receivers close to the ceiling. This places them
closer to the floor above reducing the
floor-to-floor location accuracy. It is also helpful to
place the receivers somewhat higher on the top floor to
be covered and somewhat lower on the bottom floor to
be covered.
Multi-Floor Installations: Mount receivers over one
another in multi-floor installations. This helps maintain
proper floor-to-floor reception (see Figure 1).
Figure 1: Receiver Locations
x = Receiver location inside building
Select a mounting location that:
• provides a clear line-of-sight of the protected area, if
possible.
• is at least 31 cm (1 ft.) away from metal objects such
as HVAC ducts.
• is on an inside wall, if possible.
• is 1.5 m to 1.8 m (5 ft. to 6 ft.) from the floor.
• is not at a barrier where it is important to resolve
which side an alarm location is on.
• is not damaged by tampering or opening doors.
2.2 Outdoor Receiver Installation
Receiver Spacing: Mount receivers every 91.5 m
(300 ft.). It is very important to maintain spacing as
consistent as possible to ensure optimum signal locating.
The more the receivers can detect a transmitted signal,
the more accurate the locating. Make sure each receiver
has a clear line-of-sight of the intended protection area.
Mounting Height: Mount receivers 3 m (10 ft.) above
grade. Maintain a mounting height that is as consistent
as possible to ensure optimum signal locating.
Bosch Security Systems | 6/03 | 37247D
EA102A-304 | Installation Instructions |
6
BUS
POWER
RG
+
–
+
–
5
1
2
3
4
5
3.0 Wiring
EN | 3
Overhangs/Eaves: Receiver locations should be below
building overhangs and eaves. Most transmissions occur
1 m (a few feet) above grade. Therefore, mounting above
overhangs and eaves can result in inaccurate signal
locating. Be especially careful around metal roofs as
these can block the signal.
Select a mounting location that:
• provides a clear line-of-sight of the protected area.
• is away from metallic objects such as chain-link
fences and electrical transformers. If coverage is
required near such items, perform testing near them
to determine the potential need for additional
receivers.
• is 3 m (10 ft.) above grade.
• is not at a barrier where it is important to resolve
which side an alarm location is on.
• is easy to service.
• is not damaged by tampering.
3.0 Wiring
Apply power only after all connections are
made and inspected.
3.1 EA102A-304 Layout
Figure 3: EA120A-304 Layout
Connect wiring as shown in Figure 2.
Figure 2: Multiplex Loop Wiring
1
BUS 0
PWR 0
–+–+
3
1 - Transponder
2 - Typical receiver
3 - To next device
1 - Left antenna 4 - Address
2 - Right antenna 5 - Jumpers
3 - Tamper 6 - To transponder signal bus
–
BUS
+
–
POWER
+
2