Instructions for use:

Appliance description

Chimney panelling

Light / fan switches

Lighting

Filter grille

Operating modes

Exhaust-air mode:

The extractor-hood fan extracts the kitchen vapours and conveys them through the grease filter into the atmosphere.

The grease filter absorbs the solid particles in the kitchen vapours.

The kitchen is kept almost free of grease and odours.

DWhen the extractor hood is operated in exhaust-air mode simultaneously with a different burner which also makes use of the same chimney (such as gas, oil or coal-fired heaters, continuous-flow heaters, hot-water boilers) care must be taken to ensure that there is an adequate supply of fresh air which will be needed by the burner for combustion.

Safe operation is possible provided that the underpressure in the room where the burner is installed does not exceed 4 Pa (0.04 mbar).

Operating modes

This can be achieved if combustion air can flow through non-lockable openings, e.g. in doors, windows and via the air- intake/exhaust-air wall box or by other technical measures, such as reciprocal interlocking, etc.

If the air intake is inadequate, there is a risk of poisoning from combustion gases which are drawn back into the room.

An air-intake/exhaust-air wall box by itself is no guarantee that the limiting value will not be exceeded.

Note: When assessing the overall requirement, the combined ventilation system for the entire household must be taken into consideration. This rule does not apply to the use of cooking appliances, such as hobs and ovens.

Unrestricted operation is possible if the extractor hood is used in recirculating mode

– with activated carbon filter.

Circulating-air mode:

An activated carbon filter must be fitted for this operating mode (see Filters and

maintenance).

The complete installation set and replacement filters can be obtained from specialist outlets.

The corresponding accessory numbers can be found at the end of these operating instructions.

The extractor-hood fan extracts the kitchen vapours which are purified in the grease filter and activated carbon filter and then conveyed back into the kitchen.

The grease filter absorbs the grease particles in the kitchen vapours.

The activated carbon filter binds the odorous substances.

If no activated carbon filter is installed, it is not possible to bind the odorous substances in the cooking vapours.

3

Before using for the first time

Important notes:

The Instructions for Use apply to several versions of this appliance. Accordingly, you may find descriptions of individual features that do not apply to your specific appliance.

This extractor hood complies with all relevant safety regulations.

Repairs should be carried out by qualified technicians only.

Improper repairs may put the user at considerable risk.

Do not use the appliance if damaged.

The appliance is not intended for use by young children or infirmed persons without supervision.

Young children should be supervised to ensure they do not play with the appliance.

If the connecting cable for this appliance is damaged, the cable must be replaced by the manufacturer or his customer service or a similarly qualified person in order to prevent serious injury to the user.

The appliance may be connected to the mains by a qualified technician only.

Dispose of packaging materials properly (see Installation instructions).

This extractor hood is designed for domestic use only.

Light bulbs must always be fitted when the extractor hood is in use.

Defective bulbs should be replaced immediately to prevent the remaining bulbs from overloading.

Never operate the extractor hood without a grease filter.

Overheated fat or oil can easily catch

fire.

If you are cooking with fat or oil, e.g. chips, etc., never leave the cooker unattended.

Before using your appliance for the first time, please read these Instructions for Use carefully. They contain important information concerning your personal safety as well as on use and care of the appliance.

Please retain the operating and installation instructions for a subsequent owner.

Do not flambé food directly under the extractor hood.

!Risk of grease filter catching fire due to flames.

The hotplates must always be covered with a utensil.

Restrictions apply to the use of the extractor hood over a solid-fuel burner (coal, wood, etc.). (See Installation instructions).

Gas hobs / Gas cookers

Do not use all the gas hotplates simultaneously for a prolonged period (max. 15 minutes) at maximum thermal load, otherwise there is a risk of burns if the housing surfaces are touched or a risk of damage to the extractor hood. If the extractor hood is situated over a gas hob, operate the hood at maximum setting if three or more gas hotplates are operated simultaneously.

4

Operating procedure

The most effective method of removing vapours produced during cooking is to:

Switch the ventilator ON

as soon as you begin cooking.

Switch the ventilator OFF

a few minutes after you have finished cooking.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Light

 

 

 

 

 

Display for

Fan follow-

 

 

 

 

 

 

 

 

 

fan setting

on

 

 

 

 

 

 

 

 

 

 

 

 

Fan OFF

 

 

Reduce fan speed

Fan ON and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

increase

 

 

 

 

 

 

 

 

 

 

 

 

 

 

speed

Acoustic signal:

When a button is pressed, this is verified by an acoustic signal.

Switching off the acoustic signal:

Simultaneously press buttons 0 and + until a signal is emitted after approx. 3 seconds.

Switching on the acoustic signal:

Repeat the process.

Switching the fan ON

Press the + button.

Setting the required fan speed:

Press the + button.

The fan speed is increased by one step.

Press the – button.

The fan speed is reduced by one step.

Switching the fan OFF:

Press the 0 button.

The displayed { goes out shortly afterwards.

Or:

Keep pressing the – button until the fan

switches off.

The displayed { goes out shortly afterwards.

Intensive setting:

Maximum power is obtained at the intensive setting. It is only required for short intervals.

Keep pressing the + button until a ç appears in the display.

If the intensive setting is not cancelled by

hand, the fan will automatically switch back to step } after 10 minutes.

Fan follow-on:

Press the button.

The fan continues to run at step | for 10 minutes, and at the same time a dot flashes in the display. After this period the fan switches off automatically.

Lighting:

The light can be switched on at any time, even though the fan is switched off.

Adjusting the brightness:

Hold down the a button until the desired brightness is obtained.

Switching on the light automatically, e.g. via a timer:

Fan and light must be switched off.

Switching on:

Simultaneously press the – and ! buttons.

After approx. 3 seconds the light switches on to acknowledge the setting.

Switching off:

Repeat the process with the light switched on.

After approx. 3 seconds the light switches off to acknowledge the setting.