Systems | ARA-FPSECIO-MOD - Secure I/O module
ARA-FPSECIO-MOD - Secure I/O module
Encrypted communication with the fingerprint readerSecure door control
4 digital inputs2 relay outputs
Secure I/O is a separate controller for door control and I/ O expansion. With encrypted communication to the finger print reader BioLite Solo, it provides secure and cost effective access control for the small to medium sized office.
For enhanced security the communication between the fingerprint reader and the secure IO is encrypted.
Installation example
1 = Power supply; 2 = Door lock; 3 = Exit button;
4 = Door sensor; 5 = RS485 secure communication;
6 = Secure I/O module
www.boschsecurity.com
2 | ARA-FPSECIO-MOD - Secure I/O module
Power connection
Recommended power supply
•12V ±10%, at least 500mA for Secure IO alone installation.
•Comply with standard IEC/EN 60950-1
•To share the power with other devices, use a power supply with higher current ratings.
RS485 connection
In case the length of RS-485 line is so long to affect communication stability, connect the enclosed 120 Ohm resistor between TRX+ and TRX-connector of Secure I/O.
Relay connection
Red line = fail secure lock Green line = fail safe lock
When using dead bolt or door strike, connect an enclosed diode as in the above diagram. Anode (line mark) of the diode should be connected to + power (Be careful of the direction)
CPU |
8 bit, 16 MHz Microcontroller |
Memory |
32 Kbyte flash |
Display |
10ea status LED |
IO |
4 digital inputs |
|
2 relay outputs |
Size (W x H x D) |
143 x 110 x 39 mm |
Power voltage |
12 V (max. 13.2 V) |
Power current |
500 mA (max. 800 mA) |
Normal switching capacity (normal- |
5 A – 125 Vac |
ly open) |
2 A – 250 Vac |
|
3 A – 30 Vdc |
Normal switching capacity (normal- |
2 A – 125 Vac |
ly closed) |
1 A – 250 Vac |
|
1 A – 30 Vdc |
ARA-FPSECIO-MOD - Secure I/O module ARA-FPSECIO-MOD
Accessory unit for secure door control and I/ O expansion.
Americas: |
Europe, Middle East, Africa: |
Asia-Pacific: |
Represented by |
Bosch Security Systems, Inc. |
Bosch Security Systems B.V. |
Robert Bosch (SEA) Pte Ltd, Security Systems |
|
130 Perinton Parkway |
P.O. Box 80002 |
11 Bishan Street 21 |
|
Fairport, New York, 14450, USA |
5600 JB Eindhoven, The Netherlands |
Singapore 573943 |
|
Phone: +1 800 289 0096 |
Phone: + 31 40 2577 284 |
Phone: +65 6258 5511 |
|
Fax: +1 585 223 9180 |
Fax: +31 40 2577 330 |
Fax: +65 6571 2698 |
|
security.sales@us.bosch.com |
emea.securitysystems@bosch.com |
apr.securitysystems@bosch.com |
|
www.boschsecurity.us |
www.boschsecurity.com |
www.boschsecurity.com |
|
© Bosch Security Systems Inc. 2010 | Data subject to change without notice T6755897099 | Cur: en-US, V5, 28 Oct 2010