Bosch AE115 User Manual

Bosch
BoschThermotechnology Corp. 340 Mad River Park, Waitsfield, VT 05673
Thermotechnology Corp.
Important Safety Instructions
When using this electrical equipment, basic safety precautions should always be followed, including the following:
1. READ AND FOLLOW ALL INSTRUCTIONS.
2. This appliance must be grounded.
3. Disconnect this product from the electrical supply before cleaning, servicing or removing the cover.
4. To reduce the risk of injury, close supervision is necessary when the product is used near children or elderly persons.
5. Warning: Mount the unit onto a flat section of wall, well away from any potential splashes of water or spray and away from areas where direct moist or wet contact could occur.
6. Warning: Do not install the heater in a location where it may be subject to freezing.
7. Warning: Do not install a check valve or any other type of back flow preventer within ten feet of the cold water inlet.
8. The electrical installation must conform to current National Electrical Codes.
9. Warning: Do not switch the heater on if you suspect that it may be frozen. Wait until you are sure that it has completely thawed out.
10. The PowerStar is designed to heat potable cold water for domestic purposes. The maximum inlet water temperature it can handle is 86 degrees F. Contact Bosch Thermotechnology Corp. before specifying or installing the appliance in any other appli cation.
11. Additional Canadian safety instructions:
a) As per the Canadian Electrical Code, C22.1-02 Section 26-744, an auxiliary terminal block
must be fitted to the unit before connecting to the electrical supply (Kit Part N° “AE Canada Kit”). (See Page 7).
b) A green terminal (or a wire connector marked “G,” “GR,” “GROUND” or “GROUNDING”) is
provided within the control. To reduce the risk of electrical shock, connect this terminal or connector to the grounding terminal of the electrical service of supply panel with a continuous copper wire in accordance with the Canadian Electrical Code, Part I.
c) This product shall be protected by a Class A ground fault circuit interrupter.
Contents
Specifications 3 Installing the PowerStar 3 Starting up the PowerStar 8 How the PowerStar works 9 Using the PowerStar 10 Spare Parts 11 Maintenance 11 Troubleshooting 12 Warranty 15
SAVE THESE INSTRUCTIONS
Keep this guide in a safe place once your unit has been installed.
You may need to refer to it for general instructions or future maintenance.
2
Specifications
AE115 Unit AE125 Unit
Voltage supply 2 x 240V AC (Canada 240VAC) 3 x 240V AC (Canada 240VAC) Amperage 2 x 40 A (Canada 80 A) 3 x 40 A (Canada 120 A) Maximum output 17.25 kW 26.85kW Temperature control range 95°F to 131°F 95°F to 131°F Pressure range 15 psi to 150 psi 15 psi to 150 psi Minimum flow rate 0.6 US gal / min 0.8 US gal / min Maximum flow rate See Graph 1, Page 8 See Graph 1, Page 8 Dimensions (excl. water couplers) 15½” H x 151/4” W x 4½” D 15½” H x 151/4” W x 4½” D Weight (without water) 20 lbs 22 lbs
Note: The unit will work at lower supply voltages but the following changes will apply:
Maximum output 15kW at 220V
13kW at 208V
Temperature control range 87°F to 116°F at 220V
82°F to 108°F at 208V Maximum flow rate (refer to Graph 1, Page 8)
84% of maximum at 220V
75% of maximum at 208V
22.5kW at 220V 20kW at 208V 87°F to 116°F at 220V 82°F to 108°F at 208V 84% of maximum at 220V 75% of maximum at 208V
Installing the PowerStar
WARNING:
If water supply has a high mineral content, a water softening system is strongly recommended. Damage to the water heater resulting from scale or hard minerals will not be covered under warranty.
DISCLAIMER:
In the Commonwealth of Massachusetts a licensed plumber or electrician must perform the installation. (Approval number: P1-09-25).
Locating the Powerstar
WARNING:
Do not install the water heater in an area where there is a chance of freezing. Damage to the water heater as a result of freezing will not be covered under warranty.
If being used in a public place, locate the heater out of easy reach to discourage vandalism.
Mount the unit onto a flat section of wall, well away from any potential splashes of water or spray
and away from areas where direct moist or wet contact could occur.
Should it be necessary to service the Powerstar, observe the following clearances. These are not required clearances, but would facilitate any service work.
Recommended minimum
clearances for servicing
Top 12” Bottom 6”
Sides 0” Front 12”
3
Mounting the Powerstar
WARNING:
The heater must only be installed in the orientation shown in Diagram 1 i.e., mounted in a vertical position with the water fittings located at the bottom of the heater. Under no circumstances should the heater
be mounted differently.
Undo the retaining screws on the front cover and take the cover off the heater. Hold the back plate in position against the wall and mark the four mounting holes
Drill the holes and secure the heater using the four wood screws supplied.
Diagram 1
AE115 Unit AE125 Unit
Water Connections
WARNING:
Do not install a non-return check valve within 10 feet of the inlet.
WARNING:
Do not apply heat or solder to connections or pipe if they are already connected to the unit.
DISCLAIMER:
In the Commonwealth of Massachusetts a pressure relief valve shall be installed on the cold water side by a licensed plumber. (MGL 142 Section 19, Approval number P1-09-25)
The heater must be connected directly to the main cold water supply and not to pre-heated water. (The inlet water temperature must not be greater than 86°F.)
The heater must be installed wit h shutoff valves on both the inlet and outlet connections.
It is recommended that you use ¾ inch or ½ inch copper or high-pressure flex connections.
4
Do not use plastic piping within 3 feet on either side of heater.
Use Teflon tape for sealing pipe threads. Do NOT use pipe dope.
Remember to keep the hot water pipe runs as short as possible.
After the heater has been plumbed, and before you wire it, flush it with water to remove any debris
or loose particles. Heater must be full of water and air purged before power is turned on. Failure to do so may make the heater inoperable.
The inlet and outlet connections are clearly marked on the heater. They each have a ¾ inch NPT connector.
Check the pressure of the main water supply. To operate correctly, the heater needs the following running pressures:
Recommended water pressures
Min water pressure 15 psi (1 Bar) Max water pressure 150 psi (10 Bar)
Electrical connections
WARNING
The unit must be wired by a qualified electrician, in accordance with the current version of the National Electrical Code US) or Canadian Electric Code (Canada).
IMPORTANT
When the heater is not within sight of the electrical circuit breakers, a circuit breaker lockout or additional local means of disconnection for all non-grounded conductors must be provided that is within sight of the appliance. (Ref NEC 422.31.)
IMPORTANT
As per the Canadian Electrical Code, C22.1-02 Section 26-744, an auxiliary terminal block must be fitted to the heater before connecting to the elect rical supply. This is available as a kit from Bosch Thermotechnology Corp. Part Number “AE Canada Kit”. (Contact 866-642- 3199).
US wiring
The minimum recommended wire size is 8 AWG. (The terminal block will accept cables up to 6 AWG size.)
The cable entry is via the 1 ¼ inch cable entry hole on the bottom right hand edge of the back plate.
Strip back the insulation on the power wires about ½ inch. Connect the live wires to the terminals
marked “L1” and “L2.” There are two pairs of live wires in the AE115 and three pairs of live wires in the AE125. (See Diagrams 2 or 3 on page 6).
Any insulation on the ground wires should be stripped back about ¾ inch. The ground leads must be connected to the pillar terminal marked “GR”. (See Diagrams 2 and 3, Page 6).
Make sure the terminal block screws are tightened securely. Loose connections can cause wires to heat up.
Make sure that the ground wires are wrapped around its terminal stud and into the saddle washer. The nut should be tightened securely.
Attach the front cover and tighten the retaining screws.
5
Diagram 2
AE115 Terminal Block Connection
The AE115 requires two independent 240V AC circuits protected by two separate and independent double pole breakers (as shown) rated at 40 A each.
Diagram 3
AE125 Terminal Block Connection
The AE125 requires three independent 240V AC circuits protected by three separate and independent double pole breakers (as shown) rated at 40 A each.
6
Canada wiring – auxiliary terminal block and connections
Fitting the auxiliary terminal block (see diagram below).
AE115 AE125
NOT
FOR
U.S.A.
Connect the red wires from the left hand terminal of the new block to the L1 terminals in the unit. (There are two red wires required in the AE115 and three in the AE125).
Connect the blue wires from the right hand terminal of the new block to the L2 terminals in the unit. (There are two blue wires required in the AE115 and three in the AE125).
Push and click the auxiliary terminal block onto the louvered rail in the backplate.
Connecting the supply cable - Canada only - not for the USA.
The AE115 requires an 80A 240V AC single phase supply protected by an 80A double pole circuit breaker.
The power cable size and the installation must be in accordance with the Canadian Electrical Code, C22.1-02.
The incoming hole diameter on auxiliary terminal block can accept up to 1/0 AWG size cables.
The cable entry is via the 1 ¼ inch cable entry hole on the bottom right hand edge of the backplate.
Strip back the insulation on the power wires about ½ inch. Connect the ungrounded conductors to
the terminals “L1” and “L2” on the auxiliary terminal bl ock.
Any insulation on the ground wire should be stripped back about ¾ inch. The ground lead must be connected to the pillar terminal marked “GR.”
Make sure the terminal block screws are tightened securely. Loose connections can cause wires to heat up.
Make sure that the ground wire is wrapped around its terminal stud and into the saddle washer. The nut should be tightened securely.
Attach the front cover and tighten the retaining screws.
The AE125 requires a 120A 240V AC
single phase supply protected by a 120A double pole circuit breaker.
7
Starting up the PowerStar
Checking for leaks and purging air
Verify all circuit breakers supplying power to the water heater are turned off.
Open all hot water taps supplied by the water heater and inspect all water connections for leaks.
With all hot water taps still open, inspect each tap to ensure all air in the lines has been purged out.
With the air purged and taps still flowing, turn on all circuit breakers supplying the water heater.
Close all hot water taps and proceed to the next section.
Adjusting the temperature dial
The temperature adjustment is made using the dial on the bottom edge of the unit. The adjustment is between approximately 95°F and 135°F. Turning the dial clockwise increases the temperature setting as indicated by the marking on the unit.
Adjusting the flow
Open fully both inlet and outlet shut-off valves at the heater, then :
Turn on fully the highest flowing hot water faucet (e.g., bathtub) served by the water heater.
Adjust the outlet shut-off valve until the water flow rate from the hot faucet corresponds to the value
given in Graph 1 below.
Graph 1
Outlet Temperature vs Maximum Flow Rate Setting
(based on incoming water temperature of 55°F)
5.00
4.50
4.00
3.50
AE125 Heater
3.00
2.50
2.00
Max Flow Rate (US gal / min)
1.50
1.00 95 100 105 110 115 120 125 130 135
AE115 Heater
Outlet Temperature (°F)
8
For example:
For the AE115 unit, using the outlet ball valve, ensure the flow rate does not exceed 2.3 gallons / minute.
For the AE125 unit, using the outlet ball valve, ensure the flow rate does not exceed 3.5 gallons / minute.
Note: These figures are based on an inlet water temperature of 55°F and a supply voltage of 240 volts. If the inlet water temperature is lower than 55°F, or if the supply voltage is less than 240 volts, then the outlet temperature will be lower than what is shown in Graph 1. If a higher outlet water temperature is desired, then reduce the flow rate and/or supply the unit with 240 volts.
IMPORTANT
Before leaving the site, the installer should demonstrate the unit to the user and give them this guide.
How the PowerStar works
The PowerStar heats water continuously as it flows through the heater modules.
The electronic control PCB monitors the flow rate and the incoming water temperature and then
switches on the required number of heater elements to reach the temperature set by the adjustment dial.
As the flow rate or the incoming water temperature changes, the electronic control adjusts the number of heater modules used so that the outlet temperature is maintained.
The outlet water temperature can change slightly as the flow rate changes due to the steps in power as different heater modules are switched on and off.
The outlet water temperature can also vary if the maximum flow rate is exceeded (see Graph 1) or if the supply voltage changes.
Each heater module is protected by an electro-mechanical thermal cut-out. If the temperature of any of the heater modules gets too high, then the cut-out will trip and cut the power to that heater module. If the cut-out trips, it must be reset while the circuit breakers are off. If you are not comfortable or qualified to perform this task, consult the original installer or a licensed electrician. This cut-out will only trip in exceptional circumstances.
The AE115 unit is supplied from two independent voltage supplies and the AE125 unit from three independent voltage supplies. (In Canada the unit has just one voltage supply).
Depending on the region of the country, the temperature of the water supply can vary between 40°F in winter to 70°F in summer, with an average of 55°F.
9
Diagram 4: Internal wiring schematic for single phase AE125 unit. (AE115 does not have Elt 5 & 6 fitted
and uses two supplies). (In Canada an auxiliary terminal block is fitted during installation).
Using the PowerStar
WARNING
Do not use the unit if you think it may be frozen, as this could result in serious damage to the unit. Wait until you are sure that it has completely thawed out before you switch it on.
Check that the power is switched on at the circuit breaker panel.
Turn on the hot water faucet FULLY. The hot water temperature can be changed by adjusting the
temperature dial on the bottom surface of the unit. (The dial adjusts the temperature typically between 95°F and 131°F. The factory sets the temperature dial at the lowest position.)
There are internal safety thermal cut-outs which will trip if the unit overheats. If the cut-out trips, it must be reset while the circuit breakers are off. If you are not comfortable or qualified to perform this task, consult the original installer or a licensed electrician.
If the unit has been used recently, run the water through for a few seconds to let the temperature cool down. You may initially get a short burst of very hot water that was in the plumbing lines from previous use.
If a second outlet connected to the unit is also turned on, the hot water will be shared between the two.
10
Spare Parts
Part
Number
93 793770 4 way term. block (for AE115) 93 793771 6 way term. block (for AE125) 93 793772 Front cover (white) 93 793773 Thermal cut-out (AE115) 93 793842 Double pole cut-out (AE125) 93 793774 Flow transducer 93 793775 PCB enclosure (lid) 93 793776 PCB enclosure (base) 93 793843 Control PCB (for AE115) 93 793844 Control PCB (for AE125) 93 793779 Adjustment knob 93 793845 O Ring set 93 793846 Fixing screws for heater flange 93 793784 ¾” Inlet filter screen 93 793847 Heater element assembly 1 (AE115) 93 793848 Heater element assembly 2 (AE115) 93 793849 Heater element assembly 1 (AE125) 93 793850 Heater element assembly 2 (AE125)
(Refer to Diagram 1, Page 4)
Description
For further information ask your
FOR SERVICE AND INSTALLATION
QUESTIONS CALL:
Tel: 866- 642-3199
Fax: 806 - 496 - 6924
Bosch Thermotechnology
Corporation
Bosch Thermotechnology Corp. 340 Mad River Park Waitsfield, VT 05673 Phone 866-642 - 3199 Fax 806-496 - 6924
www.boschhotwater.com techsupport@boschhotwater.com
local dealer.
Maintenance
Check inlet water filter screen once a year
Shut off the installer supplied cold water isolation valve to the heater. If one is not installed, install before proceeding.
Open nearest hot water tap to relieve pressure in the plumbing lines.
Position a bucket under the cold water inlet connection of the heater to catch any water that may
drain.
Disconnect the cold water plumbing connection from the inlet (bottom right of heater) to access filter screen (See Diagram 1, Page 4) .
Remove filter, clean with water and inspect for damage. If the filter is at all damaged, it should be replaced.
Replace the filter into the inlet housing
DO NOT leave the filter out.
DO NOT remove the flow regulator (located behind the filter).
DO NOT clear the filter by back flushing.
NEVER use an air line to blow out the heater (the flow transducer will be permanently damaged).
11
Troubleshooting
WARNING
Always switch off the electricity supply to the unit before you remove the cover.
IMPORTANT:
If you are unable to perform the tasks listed below, or need additional assistance please contact your original installer/licensed electrician.
Flow rate is too low
The water supply is connected to
Cold water only – Neon light off
Verify the flow rate out of fixture is at or above the minimum activation rate required for the unit to activate. (Activation rates: AE115 = 0.6 GPM, AE125 = 0.8 GPM).
Verify plumbing connections are correct (See Diagram 1, Page 4). Reconnect the water supply to the inlet of the unit (marked blue).
the outlet of the unit
Plumbing crossover
To test for a plumbing crossover, turn off power supply to the heater. Close installer supplied cold water shut off valve (if none installed, install before proceeding). Open all hot water taps supplied by the heater. Wait 5 minutes and check all taps. Any water running is a sign of a plumbing crossover. Consult a local plumber or service person for help in correcting a plumbing crossover. To return the heater to service, reinstall cover, open the inlet water supply to the heater and open all hot water taps. Let all taps run until there is no air coming out of the fixtures. Shut off all hot water taps. Turn power supply on to the heater. Return heater to service. (This procedure will prevent the heating elements from burning out).
The flow transducer is not spinning
Turn off the power supply to the heater and remove the cover. Observe if the flow transducer "spins" when the water is turned on. Please note the flow transducer spins at a high speed and can appear to be stopped when actually spinning. It is recommended to observe the flow transducer without water flowing, then turn on a hot water tap while observing the flow transducer. If the flow transducer is not spinning, remove and flush flow transducer, noting the Do's and Dont's on Page 11. See the technical support section of www.boschhotwater.com for more detailed instruction on removing the flow transducer.
One or more of the heating module thermal cut-outs has tripped
Turn off the power to the heater, remove the cover and locate thermal cutouts on the top of each heating module. Try resetting each cutout by pushing the reset button located in the center of the cutout. Determine and fix the cause of the overheating. Obstructions in the water path can restrict the flow of water through the heater causing it to overheat. Verify the heater’s inlet filter screen and all outlets served by the heater are clear of debris. Ensure the heater is not being fed preheated water. This water heater is designed for a cold water supply only. If thermal cut out does not reset, check for continuity through each cutout (less than
0.5 Ohms). If any cutout reads more than 0.5 Ohms or open, then it may be defective and should be replaced.
No electricity at the heater or one of the supplies has failed
Have a licensed electrician verify proper wiring and adequate voltage on the terminal block inside the water heater. See the “Electrical connections” section on Page 5 of this manual.
12
Temperature dial is turned too low
Water flow is too high
One or more of the heating module thermal cut-outs has tripped
The power supply voltage has dropped
The inlet water temperature is too cold
One of the power supplies is not on
Premature element failure
Water too cold – Neon light on
Turn the temperature dial located on the bottom of the water heater clockwise for hotter temperatures. Refer to Graph 1 for outlet temperature vs. flow rate variance.
Adjust water flow to stay within the water heater’s specifications. See Graph 1 on Page 8 of this manual.
Shut off the power to the unit, remove the cover and locate thermal cutouts on the top of each heating module. Try resetting each cutout by pushing the reset button located in the center of the cutout. Determine and fix the cause of the overheating. Obstructions in the water path can restrict the flow of water through th e heater causing it to overheat. Verify the heater’s inlet filter screen and all outlets served by the heater are clear of debris. Ensure the heater is not being fed preheated water. This water heater is designed for a cold water feed only. If thermal cut out does not reset, check for continuity through each cutout (Less than 0.5 Ohms). If any cutout reads more than 0.5 Ohms or open, then it may be defective and should be replaced.
This is likely an issue with the incoming power supply. Have a qualified electrician measure voltage on the water heater’s terminal block while operating at maximum flow and maximum temperature setting. The AE115 / AE125 models are rated for 240V and will also operate at 220V or 208V with reduced output. The output will vary in accordance with the following ratios:
Volts 208 220 240 Output Ratio 0.75 0.84 1.0
Verify the heater is sized appropriately for it’s geographic location. Turn temperature knob located on the bottom of the water all the way clockwise for maximum temperature setting. Ensure flow rates are within the heater’s specifications. Refer to Graph 1 on Page 8 of the manual. Use of an isolation valve on the hot water outlet to control flow rate is recommended.
Have a licensed electrician verify adequate voltage on the terminal block inside the water heater. Verify circuit breakers serving the heater are not tripped. See the “Electrical connections” section on Page 5 of this manual.
Shut off power to the unit and remove cover. Use an ohmmeter to verify correct resistance on each element. If readings are different than listed specifications on Page 14 , contact Technical Support (866) 642-3199 for further instruction.
13
Using an Ohmmeter to check for Premature element failure
Note: On AE115 model, there is no middle element.
There are restrictions in the plumbing
Water supply pressure too low
Outlet shut-off valves are set too low
LEFT MODULE Top View RIGHT MODULE Top View
Meter probes Ohm Reading Meter probes Ohm Reading
Outer to Outer 10.5 ± 0.5 Ohms Outer to Outer 10.5 ± 0.5 Ohms Middle to Middle 11.5 ± 0.5 Ohms Middle to Middle 11.5 ± 0.5 Ohms Inner to Inner 15.0 ± 1 Ohms Inner to Inner 21.0 ± 1 Ohms
Obstructions in the water path can restrict the flow of water through the heater.
Water flow too low
Verify the heater’s inlet filter screen, faucet aerators, showerheads and whole house filters are clear of debris. Verify proper flow on the outlet side of the heater with the hot water pipe disconnected. Maximum flow rates for each unit are as follows. AE115 = 2.3gpm, AE125 = 3.5gpm.
Verify incoming water supply is at least 30psi. For people on well systems, the recommended pressure range is 30-50psi.
Adjust installer supplied outlet valve as described below:
Completely open both installer supplied inlet and outlet shut-off valves at the heater. (if none installed, install before proceeding)
Completely open hot water on the highest flowing hot water fixture served by the heater (i.e. bathtub).
Slowly close the outlet shut-off valve, slowing the water flow rate until the temperature at the hot water faucet corresponds to the values given on Graph 1 on Page 8 of the manual, or desired water temperature is reached.
14
Temperature dial set too high
There are restrictions in the plumbing
Turn the temperature knob located on the bottom of the water heater counterclockwise for cooler temperatures.
Obstructions in the water path can restrict the flow of water through the heater causing overheating. Verify the heater’s inlet filter screen, faucet aerators, showerheads and whole house filters are clear of debris. Verify proper flow on the
Water Temperature Too Hot
outlet side of the heater with the hot water pipe disconnected. Opening hot water isolation valve fully may be necessary. Maximum flow rates for each unit are as follows. AE115 - 2.3gpm, AE125 - 3.5gpm.
Inlet water temperature is too warm
Cold mix, heater deactivates
Verify the heater is being feed with cold water only. This water heater is not designed for preheated water or recirculation applications. Increase flow rate where ever possible. Replacing low flow showerheads and aerators with higher flowing (GPM) ones may be necessary.
Water Temperature Fluctuates
If inlet water temperature is over 70°F, water may be very hot out of the tap. This requires a lot of cold water to be added in order to get a usable hot water temperature. The addition of too much cold water will overpower hot water demand from the water heater. This slows the flow within the water heater, decreasing it below the activation point, which shuts off the heater. The end result is nothing but cold water coming out of the outlet. Increase the flow rate by cleaning or replacing fixtures and lower the setting on the temperature adjustment knob. See service bulletin TWH-E2-04 at www.boschhotwater.com for further troubleshooting on this symptom.
Fluctuating water pressure
If the water pressure in the home is erratic and the water flow is not consistent while a tap is opened, then the temperature of hot water will fluctuate. The minimum water pressure for the home should be 30psi or greater. For people on well systems the minimum pressure range is 30-50psi. The use of a pressure reducing/regulating valve is an effective way to maintain constant water pressure to the water heater. Watts brand 25AUB- ¾” or N35B-¾” pressure reducing/regulating valves or equivalent is suggested.
Changing flow rate Major changes in flow rate can adversely affect the output water temperature of
the heater. Increases from one major fixture running to multiple fixtures running at one time can cause the temperature to fluctuate. Stay within the heater’s specifications. See Graph 1 on page 8.
PowerStar LIMITED 10 YEAR WARRANTY
COVERAGE
BOSCH THERMOTECHNOLOGY CORP. guarantees this water heater to the original owner of the water heater at the original installation location against defects in material and workmanship for the periods specified below.
WARRANTY PERIOD
1. The Heating Modules – If the original heating module leaks or fails within ten (10) years from the date of original installation of the water heater because of a defect in material or workmanship, Bosch Thermotechnology Corp will furnish to such an owner a replacement heater of the then - prevailing
(Continued…) 15
(…Continued) comparable model. However, if the water heater is installed in other than a single family dwelling this
heating modules warranty is limited to two (2) years from the date of original installation and oper ation.
Note : Damage caused by exposure to freezing conditions is not covered by the warranty. Note : Damage caused by scale formation is not covered by the warranty.
2. Any Component Part Other Than the Heating Modules – If any other component part (other than the heating modules) proves to be defective in material or workmanship within one (1) year from the date of original installation of the water heater, Bosch Thermotechnology Corp. will furnish the owner with a replacement of the defective part(s).
3. Verification of Date of Original Installation – When owner cannot verify or document the original date of installation, the warranty period begins on the date of manufacture marked on the tag affixed to the water heater.
EXCLUSIONS
1. THIS LIMITED WARRANTY SHALL BE THE EXCLUSIVE WARRANTY MADE BY THE MANUFACTURER AND IS MADE IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED (WHETHER WRITTEN OR ORAL), INCLUDING, BUT NOT LIMITED TO, WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
2. Manufacturer shall not be liable for incidental, consequential, special or contingent damages or expenses arising, directly or indirectly, from any defect in the water heater or the use of the water heater.
3. Manufacturer shall not be liable for any water damage arising, directly or indirectly, from any defect in the water heater component part(s) or from its use.
4. Manufacturer shall not be liable under this warranty if: a) The water heater or any of its component parts has been subject to misuse, alteration, neglect
or accident, or;
b) The water heater has not been installed in accordance with the applicable local plumbing
and/or building code(s) and/or regulation(s), or;
c) The water heater has not been installed in accordance with the printed manufacturer’s
instructions, or;
d) The water heater is not continuously supplied with potable water.
5. The owner and not the manufacturer or his representative shall be liable for and shall pay for all field damages for labor or other expenses incurred in the removal and/or repair of the product or any expense incurred by the owner in order to repair the product.
SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHERS.
IMPORTANT: OWNER SHALL KEEP THIS CERTIFICATE
NOTE: A water heater must be installed in such a manner that if it should leak, the resulting flow of
water will not cause damage to the area in which it is installed.
You can also call Bosch Thermotechnology Corp. at 866-642-3199. Please have this guide, model number, serial number and date of installation with you when you call.
Bosch Thermotechnology Corporation
The person who initially installed the unit is the best one to contact for help.
Bosch Thermotechnology Corp. 340 Mad River Park Waitsfield VT 05673
TOLL FREE: 866-642 - 3199 Fax: 806-496-6924
555 - 2028-10G Waitsfield, VT all rights reserved
www.boschhotwater.com
© 200 8 Bosch Thermotechnology Corp.