Please keep this important manual in a safe place. It is the owner’s responsibility to ensure that
regular maintenance is carried out on this Ducted Evaporative Air Conditioner. Failure to do so will
void all guarantees beyond statutory and legal requirements.
www.climatetechnologies.com.au
PNE2002 Series Control
Page 2
Manual Comfort Control
Notes
Introduction
Congratulations on your choice
We are delighted you have chosen an air conditioning product from
Climate Technologies to cool your home. It’s an air conditioner we’re
very proud of. Designed and made in Australia by Climate
Technologies, a 100% Australian owned company, it contains the
latest advances in Fresh Air Conditioning technology in a stylish,
attractive cabinet.
Climate Technologies is constantly researching and developing improved product
features and therefore reserves the right to change specifications without notice.
E.&O.E.
Your ducted evaporative air conditioner is engineered to meet the rigors of our harsh Australian
environment. Operated and maintained in accordance with this manual, it will provide you with years
of quiet, cool and environmentally friendly operation. Please take the time to read this manual.
The principal of your unit is to introduce fresh air, which is washed through the filter pads to provided
cool fresh air. The air is exhausted taking with it any heat loading on the home.
Unit Operation
Exhaust
It is essential for successful operation of evaporative air-conditioning that there be sufficient exhaust
openings in the area to be ventilated. Open doors and windows will usually provide this.
The minimum exhaust opening should be as per the table guide set out below. It is recommended
that ceiling vents or exhaust fans be used where there is any doubt about there being sufficient
exhaust area available. Ceiling exhaust fans or ceiling vents should have a capacity equivalent to
that of the air conditioner.
MODELMINIMUM EXHAUST
AREA
Medium0.68m² to 1.48 m²
PNE2002 Series Control
Large2.02 m²
Page 4
Page 5
Manual Comfort Control
Ducted Evaporative Air Conditioning
Bleed-off
All evaporative air conditioners need some water bleed-off to prevent build-up of mineral deposits in
the system. The correct setting of the bleed rate will ultimately govern the life of the unit.
With normal town water supply, bleed rate should be adjusted so that the discharge is not less than
approximately 10 litres per hour. Increased water hardness may require a higher bleed rate and
increased maintenance.
The method for setting the bleed rate is to adjust the patented DIALFLO unit located externally on the
unit.
It is recommended to plumb the bleed-off away from the unit to a down pipe in situations where the
discharge may cause unsightly stains, e.g. Colorbond Roofs.
If dump valve fitted and dumping cycles activated, bleed off may not be required.
Dump Valve (Where Fitted)
A dump valve can be fitted to a unit using the MANUAL control. There are no timer control functions
available with this control. The dump valve solenoid is activated or deactivated when the pump
operation is used.
PNE2002 Series Control
Page 5
Page 6
Manual Comfort Control
Operating the Controls
Operating the Controls
Control Functions
The MANUAL control is a simple low voltage controller that allows you to operate each function of the
product as required to keep you home cool. As there is no thermostat in the Manual control it can be
located anywhere that is convenient to the customer and the installer.
To use the control you will need to turn the fan ON, or the fan and cool switches ON to operate .
Using the Fan Mode
Using the fan mode on the Manual control the unit will
Variable Speed
Control Knob
Fan ON / OFF
Switch
operate the fan only providing ventilation in the building.
1. To activate the room air fan, turn the Fan ON / OFF
switch on by toggling the switch to the right.
2. To adjust the speed of the fan, rotate the FanSpeed control knob. Clockwise will increase
the air and anti-clockwise will decrease the air.
Your product is fitted with a variable speed fan
motor and therefore can be adjusted to your desired
level of air.
Pump ON / OFF
Switch
3. To turn the fan OFF toggle the Fan ON / OFF switch to
the left. The fan will now stop.
Using the Cool Mode
Using the cool mode introduces the pump. When the pump is turned ON water will be pumped around
the water distribution system saturating the filter pads.
1. To activate the pump, turn the Cool ON/OFF switch on by toggling the switch to the right. The
pump will now pump water around the water distributor saturating the filter pads.
2. To turn the pump OFF, toggle the Cool switch to the left and the pump will stop.
Pre-Cool
As the Manual control does not have a pre-cool function, this can be simulated by:
1. Turn ON the Cool switch first and allow the pump to operate for 3 to 5 minutes. This will allow the
filter pads to be saturated with water before the fan starts.
2. After the 3 to 5 minutes is complete, turn ON the Fan switch. The unit will deliver cool fresh air with
in seconds of the fan starting.
If you do not wish to wait for the pre-cool period, the fan can be turned on at the same time as the pump
and the air will eventually become cool as the filters saturate.
NOTE: Normally during the first 10 days of operation a slight odor will be present from the CELDEK filter
pads. This 'new smell' is quite normal, and will quickly disappear as your unit is operated.
PNE2002 Series Control
Page 6
Page 7
Manual Comfort Control
Control Installation & Setup
Control Installation & Setup
PROBLEM
Unit fails to
start
Pump fails
to start
leaking
from
overflow
Water
Droplets in
air stream
Excessive
humidity
PROBABLE CAUSEREMEDY
aBlack – outaWait
bTripped Circuit BreakerbReset
cBlown FusecReplace
dElectrical FaultdCall Climate Technologies Service Provider
aPump SeizedaIsolate power and then take off top of pump
and try to free it. Some lubricant may help.
bPump Burnt OutbCall Climate Technologies Service Provider
aFloat Valve LeakingaCheck adjustment or replace sealWater
bDrain from Celdek PadsbNormal Operation
aLoose Delivery TubeaCheck and tighten
bBreak in tubingbReplace as necessary
cPump Delivers Excessive Water to
cAdjust the Dialflo to reduce the flow
Pads
aInadequate ExhaustaProvide more open area to exhaust stale air
bDry FiltersbCheck water delivery system. Adjust if
Cooling
cDialflo not set correctlycAdjust Dialflo so that the pads have even
aUnit located near odor sourceaRemove source
Unpleasant
Odor
b New Celdek filter smellbSmell will disappear after a period of
Rapid
formation of
white
deposits on
pads
Problem Solving
THIS TROUBLE SHOOTING GUIDE IS A REFERENCE ONLY.
FOR SERVICE OR WARRANTY REQUIREMENTS PLEASE REFER
necessary.
saturation.
operation.
High Mineral ContentBleed off should be set at maximum. More
regular maintenance may be required.
TO THE END OF THESE INSTRUCTIONS
PNE2002 Series Control
Page 7
Page 8
Manual Comfort Control
Control Installation & Setup
Commissioning Check List
General
! All equipment ordered by the customer is installed.
! The unit is level and secure.
! The mains and control wiring are complete and the circuit breaker and GPO are turned ON.
! All Controller functions for the appliance operate.
! All electrical or water connections are to manufacturers specifications and the relevant electrical or
plumbing standards and codes.
Unit - Ducted Evaporative Air Conditioner
! The water supply line has been flushed to clear swarf and debris and is free of leaks.
! The tank is free of foreign matter and debris and the water isolating tap is turned ON.
! Water drainpipe work is completed and sealed.
! The water basin fills with water and the float valve closes correctly when the water level is 35 -
40mm below the overflow level.
! The water pump operates correctly when turned ON at the controller.
! The Dialflo water bleed rate is adjusted to suit local water conditions.
! The Superclean Dump Valve (option). The tank drains correctly when unit turns off.
! The fan deck is correctly located and the fan blade spins freely.
! The fan operates through the entire speed range.
! The minimum fan speed is correctly set.
! Water distribution is even with the filter pads fitted and the air conditioner operating pump and fan.
! Areas of high water pressure (Exceeding 500Kpa) a water pressure limiting valve must be fitted in
accordance with AS3500. Consequential damage from high water pressure is not covered by
warranty.
Ductwork
! All ductwork is completed to plan, correctly supported and airtight, with no bend less than 1.5 x the
ductwork diameter.
PNE2002 Series Control
Page 8
Page 9
Manual Comfort Control
Control Installation & Setup
! Air distribution checked, dampers are adjusted and all outlets correctly adjusted and wiped clean.
! All roof penetrations are fully sealed and watertight.
! Man hole cover replaced.
Site
! All rubbish has been removed from inside and on the roof.
Customer Hand Over
! The operation of the Controller.
! The need to open windows and doors for the correct operation of Fresh Air Conditioning
! The operation of the bleed or dumping system and it’s importance to operate all the time in ducted
fresh air conditioning
! Maintenance requirements
PNE2002 Series Control
Page 9
Page 10
Manual Comfort Control
Unit Mantenance
DUCTED EVAPORATIVE AIR CONDITIONER MAINTENANCE
General
All Ducted Evaporative Air Conditioners benefit from some general maintenance to ensure continued
cooling efficiency and a long life. Maintenance is carried out at the beginning and end of summer to start
up and close down your unit.
We recommend that all maintenance work be undertaken by our fully trained and accredited Service
Technicians or an authorized Climate Technologies Service Provider.
The frequency of general maintenance will depend on local operating conditions such as water quality,
air borne dust and pollen.
It is essential that your evaporative air conditioner is maintained in accordance with this manual. Failure
to do so will effect the life of the product and reduce the level of efficiency.
For service Australia wide refer to the details on the rear of the manual.
NOTE: The manufacturer and it's service providers reserve the right to refuse service unless
safety and accessibility to the unit can be guaranteed. The cost of any extra equipment required
to provide access to the unit for servicing is the responsibility of the owner.
SAFETY: Prior to commencing any maintenance isolate the unit at the power source. Ensure the
roof is safe to access, your ladder is securely positioned and you're wearing suitable, sturdy
non-slip footwear.
Filter Pads
Visually check filter pads for sagging or blockage. Hose down pads from both sides to remove any
build up of salts, dust and pollen. In dusty areas more regular cleaning is recommended. Check the
water distributor, making sure it is clear and free from blockage. Failure to do so may lead to uneven
water distribution and therefore less efficient operation.
Water Tank
It is important to keep the water tank clean and free from sediment and algae growth. To clean the
tank, use a soft brush or similar. Wipe all surfaces in the tank while it is full of water (DO NOT FORGET
THE PUMP STRAINER). Drain the tank by removing the 40mm standpipe. It may be necessary to
repeat this procedure if the tank is very dirty.
Safety: Wet roofs are dangerous – Take Care When Draining Tank.
PNE2002 Series Control
Page 10
Page 11
Manual Comfort Control
Unit Mantenance
Water Level / Float Valve
The water level should be set at nominal 35 - 40mm from the top of the overflow before filter pads are
saturated. After run off from the operating pump / filters the level from the top of the overflow fitting
should be 25 – 30mm. The float valve is a mechanical type and is factory set. If it requires adjustment
keep bends tight.
If the valve is leaking the seal may require cleaning or replacing.
" Turn the water off
" Remove the split pin and then float arm.
" Remove piston and clean or turn seal.
" Flush system
" Replace piston, float arm and split pin.
Note:Water supply line to float valve must be flushed before connecting.
Note:Some discharge from the overflow may be experienced after shut down due to water
draining back from the Celdek pads. This is normal.
Motor and Fan
Check that the fan spins freely and that there is no build up on the blades.
Electrical
No general maintenance is required to the electrical system.
A Qualified Electrician should only carry out electrical connections and maintenance.
Bleed Off
The bleed rate should be checked to ensure it is adequate and that there is no build up of mineral
deposits in or on your air conditioner. White deposits indicate high mineral content and the Bleed Rate
should be increased. If it is at maximum and the deposits are still forming, then more regular
maintenance is required.
Pump
Check the pump spins freely and that the strainer is clean.
Water Distribution
Check the water distribution system for blockage. Check the delivery tube for kinks or holes. Check
that the clamps are secure and in place.
PNE2002 Series Control
Page 11
Page 12
Manual Comfort Control
Warranty – Australia ONLY
Warranty
Warranty Statement.
Subject to the following conditions we provide, from the dated proof of purchase, the
following warranty:
Any part found to be defective in workmanship or material within the period of warranty will be
replaced free of charge.
The structural warranty covers any structural components within the unit, which fail to perform
their intended function due to faulty manufacture or deterioration within the warranty period.
Conditions And Exclusions
•Travelling time and mileage are included within 30km of either your authorized Climate
Technologies dealer or service provider’s premises. Customers in areas other than the above
are responsible for any travelling time and mileage required to carry out warranty repairs.
• The product must have been installed in the manner prescribed by local statutory regulations
and to the manufacturer’s specifications by a qualified person.
• Service within the terms of this warranty will be recognized where we are satisfied that the
appliance or part was supplied within the relevant time limits. Documents of purchase and
Dealer/Installer information will assist in this process.
• A charge will be made for work or a service call where there is nothing wrong with the
appliance or where the defective operation of the appliance is due to failure of electricity or
water supply, or where defects are caused by neglect, incorrect application, abuse or by
accidental damage of the appliance, or by an unauthorized person attempting to repair the
appliance.
• No responsibility will be accepted for outside elements such as pests, animals, pets and vermin
that may cause damage to the unit.
• Harsh environmental situations such as salt air that may cause cabinet or electronic damage can
not be considered warranty.
• Claims for damage to contents, carpet, walls, ceilings, foundations or any other consequential loss
either direct or indirect resulting from, power spikes, incorrect operation, incorrect installation or
faulty product are excluded.
NOTE: In addition to this warranty, the Trade Practices Act and similar laws in each state provide the
owner, under certain circumstances, with minimum statutory rights in relation to the product.
This warranty must be read subject to that legislation and nothing in this warranty has the effect of
excluding, restricting or modifying those rights.
PNE2002 Series Control
Page 12
Page 13
Manual Comfort Control
Warranty – Australia ONLY
Warranty On Replacements Parts.
Parts replace under warranty are warranted for the balance of the original warranty period.
All Electrical Components2111
** All other components1111
** Filter pads are a consumable item and therefore are not covered by the above warranty periods.
10111
PNE2002 Series Control
Page 13
Page 14
Manual Comfort Control
Warranty – Australia ONLY
Proof Of Purchase
It is important that the name of the Dealer or Retailer from whom you purchased your product and the
name of the installer is recorded on this page. The installer is responsible for the correct installation,
start up and demonstrating the operation of this product. He is also responsible for issuing the relevant
certificates of compliance for the electrical and gas connections. (These may differ from state to state)
Please attach your proof of purchase here. Your receipt is your warranty and will be required to validate
any warranty.
Dealer / Product Information
Dealer/Retailer:
Dealer Address:
Dealer Phone Number:
Unit Model Number:
Serial No:
Date Installed:
Installed by:
PNE2002 Series Control
Page 14
Page 15
Manual Comfort Control
Warranty – Australia ONLY
SERVICE.
A qualified service technician should conduct any service work carried out on your ducted gas central
heating or cooling product. It is important that periodical service is carried out on your product to ensure
your will receive the efficiency benefits the product provides.
An authorized Climate Technologies service provider must carry out warranty service.
For Metro Service only ring the numbers below.
South Australia (08) 8307 5230
NSW / ACT (02) 6953 5968
Western Australia (08) 9358 4755
Victoria (03) 9763 5988
or
(02) 6953 5968