Please keep this important manual in a safe place. It is the owner’s responsibility to
ensure that regular maintenance is carried out on this evaporative cooling product.
Failure to do so will void all guarantees beyond statutory and legal requirements.
BONAIRE DURANGO WINDOW COOLER
General Information
Thank you for purchasing a quality Bonaire Evaporative Cooler. We care about your safety
and would ask you to spend a few minutes reading these simple instructions before installing
or operating this product.
Safety!
Read carefully all of these instructions prior to installing
and operating the unit.
• Read and Save these Instructions. Do not throw these Instructions away.
Complete the unit assembly before attempting to install, refer •
to page 7.
•Installation of this cooler in any manner not prescribed by these instructions could
cause a safety issue and WILL void any warranty.
• Use only with a 240V 50Hz single phase grounded outlet.
• Unplug the cooler and position the rotary control knob to the 0 position when installing,
servicing or cleaning.
• Do not operate cooler with Rear Filter Panel removed.
• Do not operate cooler with a damaged cord, plug or other component.
• Do not run the power cord under carpet or other floor covering.
• Do not use the power cord with an adaptor plug that converts the 3 pin plug into a 2
prong connector.
• Do not use the cooler with an improperly grounded outlet.
• Do not alter or modify this cooler.
• Do not allow children to install, operate or service this cooler.
• fire or electric shock, do not use this product with any
WARNING: To reduce the risk of
solid state speed control device.
•ement or servicing of switches, or electrical
Use only qualified electricians for replac
motors and components in this cooler.
•
This Window Mounted Cooler is suitable for installation in windows (either sash hung
or sliding) with a minimum opening width of 560mm (22”) and height of 560mm (22”)
Please ensure that the dir
operation of this Cooler.
Ensure there is a minimu
•m 100mm (4”) clearance above the external cabinet for
maintenanc
Page 2
WEAC628
e purposes.
ections for correct mounting are adhered to for the SAFE
.
BONAIRE DURANGO WINDOW COOLER
General Information
I
mportant Notes:
• TEXT AND ILLUSTRATION COPYRIGHT CLIMATE TECHNOLOGIES 2008
•
All rights reserved. No part of this document may be reproduced or transmitted in any
form or by any means, electronic or mechanical, including photocopying, recording or by
any information storage
and retrieval system, without prior permission in writing from
Climate Technologies.
Climate Technologies is constantly researching and developing improved prod
•uct
features and there
fore reserves the right to change the specifications without
Your evaporative air conditioner is engineered to meet the rigors of harsh environments. Used
and maintained in accordance with this manual, it will provide you with years of quiet, cool and
environmentally friendly operation. Please take the time to read this manual.
The principal of your unit is to introduce fresh air, which is washed through the filter pads to
provide cool fresh air. The warm stale air within the room is forced out by the cool air through
open doors or windows.
Unit Internal View
Page 5
WEAC628
BONAIRE DURANGO WINDOW COOLER
Operation Instructions
Unit Operation
It is essential for successful operation of the evaporative cooler that there be sufficient free air
openings in the room to be cooled – approximately 0.5m². Open doors and windows will
usually provide this as per the diagrams below.
Please Note:- It is important for good ventilation that doors or windows are not open on the
windward side of the house.
Bleed Off
The bleed off rate is factory preset and is not adjustable without direction of
the manufacturer. It is critical to the life of the product that the bleed off
function is not restricted in any way as this may void unit warranty and will
cause damage to your filters and cooler.
The function of the bleed off must be inspected by the owner on a regular
basis to ensure the bleed off continuously flows when the unit is operating
in “COOL” mode.
All evaporative coolers require water bleed-off to prevent build-up
of mineral deposits as the result of the evaporative cooling
process. This will maximize the life of the premium CELdek
®
filter
pads and minimize mineral deposits inside the cooler. The bleedoff function only operates in COOL mode (when the water pump
operates).
Should water supply contain high levels of total dissolved solids
(greater than 300 p.p.m.), increase the bleed rate. See page 14.
This bleed water can be used in gardens or diverted to drains
using standard garden hose and fittings from your local hardware
store.
Please Note: - Any additional pipe work fitted to the bleed off by the owner must slope away
from the unit in a down hill manner.
Page 6
WEAC628
BONAIRE DURANGO WINDOW COOLER
Operation Instructions
COOLER OPERATION
Before Starting
•Always ensure that there is another open window or door through which the air can
exhaust to other parts of the house. Refer page 5 correct operation and ventilation.
• Ensure that the filters are kept clean.
• Ensure that the water to the cooler is turned on.
• Ensure the plug is connected to a 240V 50Hz single phase grounded appliance socket
on the inside of the house and turned on.
•IMPORTANT. After the first 10 hours of operation in COOL mode, the water must
be drained from the unit water tank to remove any new product residuals. This
process must be repeated after a further 10 hours of COOL mode operation. (See
page 13 for removing the over flow pipe.)
Operating the unit
The Durango window cooler can be operated in either of 2 modes, COOL or FAN.
•COOL Mode.
Move control knob to “COOL” side. Select
desired fan speed
1 - Sleep Mode
2 - Normal Operation
Max - Quick Cool down
The unit will now operate with the fan
motor and water pump activated.
•FAN Mode
Move the control knob to the “FAN” side
(pump isolated). Select desired fan speed
1 - Sleep Mode
2 - Normal Operation
Max - Quick Cool down
The unit will now operate with the fan motor
only activated.
•To turn the unit off, rotate the control knob to
the O position
Page 7
WEAC628
BONAIRE DURANGO WINDOW COOLER
Installation
Installation
INSTALLATION REQUIREMENTS
Tools
- Drill (Power or Cordless)
- Adjustable Wrench.
- Phillips Head Screw Driver
- Drill bits for drilling pilot holes into
window frame. 1/8" (3.2mm) drill or
appropriate for size of screw used.
- ¾” Philips Head Screws for affixing
Window Infill Panel
NPACKING THE UNIT
U
Warning
When you receive your unit the fan assembly will be partially located inside the
wet section of the product.
Before installing the product in the window the telescopic section of the
unit MUST be fixed in place.
Step 1Pull the fan assembly out of the unit by
approximately 6” (150mm) until it hits
the wet box wall.
Materials Required (Not supplied)
- Silicone for sealing Window Infill
Panel
- Copper or plastic high pressure
water pipe for mains water supply.
- 840mm (33”) of suitable spacer
material (if required)
Step 2 Fix the fan assembly into place using
the 12 pozi-drive screws supplied.
Ensure the screws are done up tight so
there is no vibration between the fan
housing and the wet box.
The unit is now ready for installing into your
window.
Page 8
WEAC628