Reminder of the pre-requisites for implementation of the next instructions
Labguard™ is one of bioMérieux's registered trademarks.
The information and graphs contained in this manual are not binding. bioMérieux therefore reserves
the right to implement changes to the document without prior notice.
bioMérieux will not approve any modifications whatsoever to the equipment implemented by
the user. bioMérieux shall under no circumstance be held liable for any direct or
consequential injury or damage whatsoever suffered by the user or by any third party, as a
result of modifications to the equipment.
• This equipment is for professional use only.
• Users are required to read all the accompanying documents, including the statutory
information, before using the equipment.
Page 5
Contents
Unpacking the device ........................................... 6
Learning about the equipment ...................................... 7
1. Fix the receiver support to the wall or to the unit to be monitored using the two screws or
adhesive strips at the rear of the support.
2. Slide the device into the support.
3. Connect the Ethernet cable.
4. In the case where the installation is not PoE, plug in the external power source using the
microUSB connector.
Labguard 3
8
RECEPT_QSG_EN-A
Page 9
4
Understanding the indicator lights
The indicator lights present on the front of the unit show the status of the Ethernet connection.
Indicator lightsStatus
Device connected to mains power supply
Alarm in communication network
Labguard 3
9
RECEPT_QSG_EN-A
Page 10
5
Technical characteristics
Environmental
conditions
Atmospheric pressure700 hPa to 1,100 hPa
Installation categoryType II according to Directive CEI 664
Device dimensions (W x H x D)Device (mm):
Device weightDevice (g):
Connectivity• Ethernet
WirelessEmission bandwidth:
Altitudeup to 2,000 m
Temperaturefrom 0 to 40°C max.
Relative humidity (Rh) from 10 to 80%
Mains power supplyInput:
100-240 VAC;
50/60 Hz; 0.3 A
Product power supply Mains power:
• 5 V ; 1 A; 5 W
Power Over Ethernet
(IEEE 802.3af)
Pollution level2
48 V ; Class 1; 0.44 to 3.84 W
• 55 x 103 x 31
• 90
• USB
• Labguard 3D sensor
Output:
5 V ; 1 A; 5 W
Device in packaging (mm):
• 167 x 133 x 74
Device in packaging (g):
• 305
Range:
• 865 to 868 Mhz,
60 channels
• 868 to 868.8 Mhz,
12 channels
• 902 to 912 Mhz,
20 channels
• 433.05 to
434.79 Mhz,
8 channels
• 100 m inside
• 400 m outside
Labguard 3
10
RECEPT_QSG_EN-A
Page 11
6
Maintenance
Disposal
Recycle the lithium batteries in accordance with enforceable regulations.
Dispose of them by the appropriate means put in place.
Cleaning the device
Clean the equipment using a cloth dampened with ethanol or any other common disinfectant.
However, avoid using formol, solvents, heat greater than 80°C (flames, autoclaving) or cleaning by
dipping or spraying.
Labguard 3
11
RECEPT_QSG_EN-A
Page 12
7
Options and accessories
Use the following options and accessories for optimum use of the device.
ReferenceDesignation
416053Mains power supply µUSB_EU
416055Mains power supply µUSB_UK
416054Mains power supply µUSB_US
416056Mains power supply µUSB_AU/CN
416057Sensor extension cable 1 m
416070µUSB/USB cable 2 m
416072RJ45 cable 3 m
Labguard 3
12
RECEPT_QSG_EN-A
Page 13
8
Equipment conformity
FCC compliance
This equipment has been declared in compliance with FCC regulations, section 15, applicable to class
B digital equipments. These regulations are designed to provide adequate protection against harmful
interferences in a residential installation. This equipment generates, uses and may emit radio-electric
waves. It can generate interferences that may be harmful to radio-communications if it is not
installed or used according to the instructions. Using this equipment in a specific installation may
generate harmful interferences, in which case the user may need to correct the interference using
one or all of the following methods:
• Redirect or move the receiver aerial
• Move the equipment away from the receiver
• Plug the equipment into a different socket from the one used for the receiver
• Contact the distributor or get help from a radio / TV technician.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions:
• this device may not cause harmful interference.
• this device must accept any interference received, including interference that may cause
undesired operation.
This equipment complies with FCC’s radiation exposure limis set forth for an uncontrolled
environment under the following conditions:
• This equipment should be installed and operated such that a minimum separation distance of
20cm is maintained between the equipment and user’s/neraby person’s body at all times.
• This transmitter must not be co-located or operating in conjunction with any other antenna or
transmitter.
NOTE: The grantee is not responsible for any changes or modifications not expressly approved by the
party responsible fr compliance. Such modifications could void the user's authority to operate the
equipment.
Industry conformity Canada (IC)
This class B digital equipment complies with Canadian standard NMB- 03.
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to
the following two conditions :
• this device may not cause interference.
• this device must accept any interference, including interference that may cause undesired
operation.
Labguard 3
13
RECEPT_QSG_EN-A
Page 14
EC compliance
This class B numeric equipment complies with the relevant EC directives and standards listed in the
accompanying certificate(s). Class B equipment is equipment suitable for use in domestic
establishments and in establishments directly connected to a low voltage power supply network
which supplies buildings used for domestic purposes. Class B equipment shall meet class B limits.
Compliance statement
Via this statement, webioMérieux SA
69280 MARCY l’ÉTOILE- FRANCE
hereby declare that the product designated hereafter - as a result of its design and its type as well as
the model that we have put into circulation - meets the fundamental health and safety requirements
defined by the EC directive concerned.
This statement shall be rendered invalid by any modification not approved by us.
Machine designation:Monitoring hardware
Model and reference type:
Applicable EC directives:• EC low voltage Directive (2006/95/EC)
• EC-ECM directive (2004/108/EC)
•
Harmonized standards applied in
particular:
The technical documents were
written by:
Date / Manufacturer's signature:13 June 2013
Signatory's position:Instrument R & D Manager
EN 61010-1 (Ed. 2010): 2010, EN 61326-1 (Ed. 2006): 2006, EN
301 489-3 (Ed. 2002 V1.4.1): 2002 V1.4.1 EN 300-220-2 V2.4.1
EN 62479: 2010
Mr Develon
(Authorized person for documentation)
Labguard 3
14
RECEPT_QSG_EN-A
Page 15
Intentionally left blank.
Page 16
Intentionally left blank.
Page 17
Intentionally left blank.
Page 18
Intentionally left blank.
Page 19
Intentionally left blank.
Page 20
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.