Bently Nevada 200350, 200355 Specifications

0 (0)
Bently Nevada 200350, 200355 Specifications

200350 and 200355 Accelerometers

Datasheet

BentlyNevadaMachineryCondition Monitoring

164804Rev. N

Description

The 200350 and 200355 Accelerometers are general purpose, case-mounted seismic transducers designed for use with Trendmaster Pro Constant Current Direct Input Card, part number 149811-02 and the Seismic Direct Input Card, part number 164746-01.

The 200350 and 200355 Accelerometers are contained within a hermetically sealed, stainless steel case. The design provides an extremely rugged transducer, well suited for harsh industrial environments. Each transducer’s top mounted, 2-pin connector (MIL-C- 5015) allows for easy installation and removal of the interconnecting signal cable. A ¼-28 threaded hole on the bottom of the casing accommodates multiple mounting options.

The 200350 and 200355 Accelerometers contain a piezoelectric sensing device, which generates charge when subjected to vibration. This charge is then converted electronically to a differential voltage signal, which is proportional to the acceleration that is parallel to the sensitive axis of the transducer.

If housing measurements are being made for overall protection of the machine, consider the usefulness of the measurement for each application. Most common machine malfunctions (imbalance, misalignment, etc.) originate at the rotor and cause an increase (or at least a change) in rotor vibration. For housing measurements alone to be effective for overall machine protection, a significant amount of rotor vibration must be faithfully transmitted to the bearing housing or machine casing, or more specifically, to the mounting location of the transducer.

200350and200355Accelerometers

 

Datasheet

164804Rev. N

In addition, exercise care in the physical

 

 

 

 

Sensitivity

 

 

 

installation of the transducer. Improper

 

 

 

 

AmplitudeLinearity

± 1%

 

 

installation can result in a degradation of

 

 

 

 

Mounted Resonant

1500 kcpm

1250 kcpm

the transducer’s performance and/or the

Frequency

(25 kHz)

(20.8 kHz)

generation of signals that do not represent

 

 

 

 

Broadband Electrical

350 µg

50 µg

actual machine vibration.

Noise

2

2

 

Upon request, we can provide engineering

(1-10kHz)

(3,434 µm/s )

(491 µm/s )

 

 

 

Output Bias Voltage

8 to 12 VDC

 

 

services to determine the suitability of

 

 

housing measurements for the machine in

Excitation Voltage

18 to 28 VDC

 

 

question and/or to provide installation.

Constant Current

2 to 20 mA

 

 

 

Excitation

 

 

 

 

 

 

 

Settling Time(within

≤ 2.0 sec

≤ 5.0 sec

 

1% of bias)

 

 

 

Specifications

Output Impedance

< 150 ohms

< 100 ohms

 

Constant

 

 

 

 

DischargeTime

≥ 0.3 sec

≥ 0.8 sec

 

 

 

 

 

 

 

Parameters arespecified from +20to +30°C

Electrical Isolation

>108 ohms

 

 

(Case)

 

 

 

(+68to +86°F) and 100Hz unless otherwise

 

 

 

 

 

 

 

 

indicated.

 

 

 

 

CAUTION

Operation outsidethe specified limits willresultin falsereadings orloss of machinemonitoring.

Do notusesensorp/n 200350 fornegative excitation voltage(-Vex).

Electrical

 

200350

200355

Sensitivity

100 mV/g

100 mV/g ±5%

 

±20%

 

(10.2

 

(10.2

 

mV/m/s^2

 

mV/m/s^2

 

±5%)

 

±20%)

 

 

Frequency Range

30-600,000

12-600,000

cpm

cpm

(±3 dB)

(0.5-10,000

(0.2-10,000

 

Hz)

Hz)

Measurement Range

± 50 g

 

 

 

 

Transverse

≤ 7%

≤ 5%

Environmental

Operating

-65°F to +250

ºF

TemperatureRange

(-54°C to +121

ºC)

Shock Survivability

5,000 g pk

 

RelativeHumidity

100% relative, condensing,

non-submerged

 

EnclosureRating

IP68

 

Physical

 

200350

200355

Hex Size

11/16”

7/8”

 

(18 mm)

(22mm)

Height

1.65”

2.06”

 

(42.4

 

(52.3 mm)

 

mm)

 

 

Weight

1.8 oz

3.3 oz

 

(51

(94

 

grams)

grams)

Mounting Thread

1/4-28 Female

Mounting Torque

2 to 5 ft-lb

 

(Maximum)

(2.7 to 6.8 N-m)

Sensing Element

Ceramic

 

Sensing Geometry

Shear

 

2/13

200350and200355Accelerometers

 

 

 

 

Datasheet

 

 

 

164804Rev. N

 

 

 

 

Hazardous Area

 

Sealing

Welded Hermetic

 

Housing Material

Stainless Steel

 

 

 

 

 

 

 

 

Approvals

 

Electrical Connector

2-Pin Mil-C-5015

 

 

Electrical Connection

Top

 

 

Position

 

Forthedetailed listing of country and product

 

 

 

 

 

 

 

 

 

 

 

specific approvals, referto theApprovals Quick

 

 

 

 

ReferenceGuide(108M1756)availablefrom

 

Compliance and

 

Bently.com.

 

 

CSA/NRTL/C

 

Certifications

 

 

 

 

 

 

 

Ex nL IIC T4:

 

 

 

 

 

 

AEx nA IIC T4:

 

FCC

 

 

 

Class I, Div 2, Groups A, B, C, D.

 

 

 

 

Ex ia IIC T4:

 

 

 

177230

AEx ia IIC T4:

 

This devicecomplies with part 15ofthe

Class I, Div 1, Groups A, B, C, D;

 

 

 

 

FCCRules. Operation is subject to the

 

 

Class II, Div 1, Groups E, F, G;

 

 

 

Class III, Div 1

 

following two conditions:

 

 

 

 

 

Install perdrawing 177234

 

This devicemay not causeharmful

 

 

 

 

 

T4 @ Ta ≤ 80°C

 

 

interference.

 

 

 

 

 

 

 

Ex ia IIC T4

 

This devicemust accept any

 

 

 

 

 

Class I, Div 1

 

interferencereceived, including

 

 

Groups A,B,C,D

 

interferencethat may cause

 

 

T4 @ -40°C ≤ Ta ≤ 80°C

 

undesired operation.

200150,

 

PerDWG 167535

 

EMC

 

200155,

Ex nL IIC T4

 

 

200157

 

 

 

 

Class I, Div 2

 

 

 

 

 

Groups A,B,C,D

 

EMCDirective2014/30/EU

 

 

T4 @ -40°C ≤ Ta ≤ 80°C

 

RoHS

 

 

 

PerDWG 167535

 

 

 

 

Ex ia IIC T4

 

 

 

 

 

200350 (Approval Option 1)

 

 

RoHS Directive2011/65/EU

 

 

Class I, Division 1, Groups A, B, C and D

 

 

 

AEx ia IIC T4

 

Maritime

 

 

Intrinsically

 

 

 

T4 @ -54 °C ≤ Ta ≤ +121 °C

 

 

 

 

Class I, Division 1, Groups A, B, C and D

 

 

 

 

Safe

 

 

 

330400 and 330425 only

 

 

(-65.2 °F ≤ Ta ≤ 249.8 °F )

 

 

 

Perdrawing 175825

 

ABS 2009SteelVessels Rules

 

 

Ex nL IIC T4

 

1-1-4/7.7,4-8-3/1.11.1,4-9-7/13

 

Intrinsically

Class I, Division 2, Groups A, B, C and D

 

 

 

 

Safeand

AEx nA T4

 

 

 

 

Non-

Class I, Division 2, Groups A, B, C and D

 

 

 

 

Incendive

 

 

 

 

 

T4 @ -54 °C ≤ Ta ≤ +121 °C (-65.2 °F ≤ Ta

 

 

 

 

 

≤ +249.8 °F )perdrawing 17582

 

3/13

200350and200355Accelerometers

 

Datasheet

164804Rev. N

ATEX/IECEx

 

 

II 1 G

 

 

 

 

Ex ia IIC T4 Ga

 

 

177230

 

II 3 G

 

 

 

Ex na IIC T4 Gc

 

 

 

 

T4@ Ta = -40°C to 80°C

 

 

 

 

 

 

 

 

 

Zone 0/1

Zone 2

 

 

 

 

 

 

 

 

 

Ui= 28V

Ui= 28V

 

 

 

 

 

 

 

Entity Parameters

 

Ii= 120mA

Ii= 120mA

 

 

 

Pi= 1W

Pi= 1W

 

 

 

 

 

 

 

 

 

Ci=0

 

 

 

 

 

 

 

 

 

 

Li=121.06µh

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

II 1 G

 

 

 

 

Ex ia IIC T4 Ga

 

 

200150, 200155,

 

II 3 G

 

 

200157

 

 

 

 

Ex na IIC T4 Gc

 

 

 

 

T4@ Ta = -40°C to 80°C

 

 

 

 

 

 

 

 

 

Zone 0/1

 

Zone 2

 

 

 

 

 

 

 

 

 

Ui= 27V

 

Ui= 27V

 

 

 

 

 

 

 

Entity Parameters

 

Ii= 150mA

 

Ii= 150mA

 

 

 

Ci=16.2 nF

 

 

 

 

 

 

 

 

 

 

 

Li= 0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

II 1 G

 

 

 

 

Ex ia IIC T4 Ga

 

 

200350

 

II 3 G

 

 

 

 

 

 

 

 

Ex na IIC T4 Gc

 

 

 

 

T4@ Ta = -54°C to +121°C

 

 

 

 

 

 

 

 

 

Zone 0/1

 

Zone 2

 

 

 

 

 

 

 

Entity Parameters

 

Ui= 28V

 

Ui= 28V

 

 

 

Ii= 200mA

 

Ii= 200mA

 

 

 

 

 

 

 

 

 

Pi= 1W

 

Pi= 1W

 

 

 

 

 

 

 

 

 

 

 

 

 

Ci=16.2 nF

Li= 0

Hazardous Area

Conditions of Safe

Use

ATEX/IECEx

Zone 0/1:

Equipment must beconnected to equipment, which meets theabovelisted entity parameters.

Thecables typeA or B(in compliancewith EN 60079-25) must respect thecableparameters listed with theentity parameters.

Zone 2 :

Thesupply electricalparameters shallnot exceed thevalues mentioned in thetables above.

4/13