Beninca Core User Manual

L8542644
12/2011 rev 4
UNIONE NAZIONALE COSTRUTTORI
AUTOMATISMI PER CANCELLI, PORTE
SERRANDE ED AFFINI
CORE
2
N
G N D
L
LAMP 115/230Vac
40W max
COM
M
C
SCA
24Vac
3W max
24Vac
200mA max
P.P.
STOP
SWO
SWC
PHOT
COM
P1 P2
SW
1 6
TW
ENC1
TCA
ANT
SHIELD
ANT
U2
F3
F2
F3 CORE 230: F6,3A F3 CORE 115: F10A
F2: F315 mA
1
8
EC declaration of confirmity
Manufacturer: Automatismi Benincà SpA. Address: Via Capitello, 45 - 36066 Sandrigo (VI) - Italia
Herewith declares that: control unit CORE. complies with the following relevant provisions: EMC guidelines: 89/336/CCE, 93/68/CEE Low voltage guidelines: 73/23/CEE, 93/68/CEE
Benincà Luigi, Legal responsible. Sandrigo, 10/11/2011.
SPECIFICATIONS
Mains power supply
230 VAC 50/60 Hz (115 VAC 50/60Hz CORE 115)
Output, Motor
1 motor, 230 VAC (115VAC CORE 115)
Motor maximum power
750 W
Output, power supply of accessories
24VDC 200mA max.
Protection level
Version in LB box: IP55 – BULL version: IP30
Operating temperature
-20°C / +70°C
Radio receiver
433.92 MHz, incorporated and configurable (rolling-code or fixed+rolling-code+ ARC Advanced Rolling Code)
No. of codes storable in memory
64
WARNINGS
This manual has been especially written to be use by quali­fied fitters.
None of the information provide in this manual can be con­sidered as being of interest for the end users.
Preserve this manual for future needs.
The technician has to furnish all the information related to the step by step function, the manual and the emergency function of the operator, and to deliver the manual to the final user.
;
Foresee on the supply net an onnipolar switch or selector with distance of the contacts equal or superior to 3 mms.
Verify that of the electrical system there is an awry differential interrupter and overcurrent protection.
Some typologies of installation require the connection of the shutter to be link at a conductive mass of the ground accord­ing to the regulations in force.
The electrical installation and the operating logic must comply
with the regulations in force.
The leads fed with different voltages must be physically separate, or they must be suitably insulated with additional insulation of at least 1 mm.
The leads must be secured with an additional fixture near the terminals.
During installation, maintenance and repair, interrupt the power supply before opening the lid to access the electri­cal parts
Check all the connections again before switching on the power.
The unused N.C. inputs must be bridged.
The descriptions and the present illustrations in this manual are not binding. Leaving the essential characteristics of the product unchanged, the manufacturer reserves himself the right to bring any change of technical, constructive or com­mercial character without undertaking himself to update the present publication.