Beckett ADC 12Vdc User Manual

12Vdc Oil Burner Manual
CORPORATION
Potential for Fire, Smoke and Asphyxiation Hazards
Incorrect installation, adjustment, or misuse of this burner could result in death, severe personal injury, or substantial property damage.
To the Homeowner or Equipment Owner:
y Please read and carefully follow all instructions
provided in this manual regarding your responsibilities in caring for your heating equipment.
y Contact a professional, qualifi ed service agency for
installation, start-up or service work.
y READ THESE INSTRUCTIONS AND SAVE FOR
To the Professional, Qualifi ed Installer or Service Agency:
y Please read and carefully follow all manual instructions
and any supplements provided, before installing, starting, or servicing this burner or heating system.
y The Installation must be made in accordance with all
state and local codes having jurisdiction.
Contents
Burner Application Scope and Intended Use ...........2
Prepare Before Installing ............................................ 3
Specifi cations .....................................................................3
Notice Special Requirements.............................................3
Hazard Defi nitions
Indicates a hazardous situation, which, if not avoided, will result
in death or serious injury.
General Information ....................................................4
A. Equipment Located in Confi ned Space ......................... 4
B.
Exhaust Fans and Other Air-Using Devices. ...................... 4
C. Clearances to Burner and Equipment ...........................4
D. Exhausting Hazardous Fumes ......................................4
E. Low Firing Rate Baffl e. ..................................................5
Nozzle Assembly Maintenance .................................. 5
A. Replace the Burner Nozzle............................................5
B. Check/Adjust Electrodes ...............................................6
C. Igniter Maintenance .......................................................6
D. Servicing Nozzle Line Assembly ...................................6
E. Check/Adjust “Z” Dimension ..........................................6
Fuel Supply ..................................................................7
A. Connect Fuel Lines........................................................7
B. Fuel Supply Level with or Above Burner........................7
C. Fuel Supply Below Level of Burner ...............................7
D. Fuel Line Replacement (Remote Tank Only) ................7
E. Fuel Line Valve and Filter ............................................. 7
Burner Wiring ...............................................................7
A. Burner installed on equipment .......................................7
B. Burner Replacement......................................................7
Drive Component Maintenance .................................. 9
A. Motor, Blower Wheel, and Coupling Replacement ........9
B. Pump Maintenance......................................................10
C. Valve Coil and Stem Replacement ..............................10
Indicates a hazardous situation, which, if not avoided, could
result in death or serious injury.
Indicates a hazardous situation, which, if not avoided, could
result in minor or moderate injury.
Within the boundaries of the hazard warning, there will be information presented describing consequences if the warning is not heeded and instructions on how to avoid the hazard.
Intended to bring special attention to information, but not related to
personal injury or property damage.
Start Up Burner & Set Combustion ..........................10
A. Basic Burner Operation ...............................................10
B. Combustion Set-up ...................................................... 11
C. Set Combustion with Instruments................................ 11
Maintain & Service Burner ........................................ 12
A. Owner’s Information ....................................................12
B. Owner Service and Maintenance ...............................12
Extended Down Time ....................................................... 12
Regular Service/Maintenance ..........................................12
Troubleshooting ........................................................13
Replacement Parts ....................................................15
Limited Warranty Information ..................................16
2
Burner Application Scope
and Intended Use
The ADC burner is designed for use in road maintenance equipment applications that have DC voltage charging systems capable of sustaining the specifi ed voltage requirements. For other equipment applications, please contact Beckett Technical Services at 1-800-645-2876.
Section: Prepare Before Installing
Prepare Before Installing
Owner’s Responsibility
Incorrect installation, adjustment, and use of this burner could result in severe personal injury, death, or substantial property damage from fi re, carbon monoxide poisoning, soot or explosion.
Contact a professional, qualifi ed service agency for the installation, adjustment and service of your oil heating system. This work requires technical training, trade experience, licensing or certifi cation in some states and the proper use of special combustion test instruments.
Please carefully read and comply with the following instructions:
y Never store or use gasoline or other fl ammable liquids
or vapors near this burner or appliance.
y Never attempt to burn garbage or refuse in this
appliance.
y Never attempt to light the burner/appliance by throwing
burning material into the appliance.
y Never attempt to burn any fuel not specifi ed and
approved for use in this burner.
y Never restrict the air inlet openings to the burner or
the combustion air ventilation openings in the room.
Impaired Burner Performance and Fire Hazard.
Do NOT operate the burner beyond specifi cations outlined in the table to the right.
y For applications beyond these limits, consult Beckett
Technical Service at 1-800-645-2876.
y NOTE: Some packaged appliances with burners
may be agency listed as a unit to operate beyond these limits. Consult the appliance manufacturer’s specifi cations and agency approvals for verifi cation.
Specifi cations
Capacity ‘F’ Head
Firing Rate: 0.75 - 2.50 GPH Input: 105,000 - 350,000 Btu/h
Fuels USA: No. 1 or No. 2 diesel fuel or kerosene;
No.1 or No. 2 heating oil (ASTM D396)
DO NOT USE GAS-
OLINE, CRANKCASE OIL, OR ANY OIL CONTAINING GASOLINE.
Electrical Power Supply: 13.5 Vdc
Operating Load w/ igniter on: 15 Amps
w/ igniter off: 8 - 10 Amps
Motor: 13.5Vdc, 1/6 hp, 3450 RPM, 10 Amps (max.) NEMA “M” Flange, rotation CCW when facing shaft end.
Ignition Secondary: 20KVpk 25mA
Interrupted duty OR optional continuous duty.
Pump Outlet pressure: Note 1
Dimensions Height (maximum): 11 ½ inches
Width (maximum): 14 3/8 inches Depth (chassis only): 6 9/16 inches Air tube diameter: 4 inches
Ambient Operating Temperature
Note 1. See equipment manufacturer’s burner specifi cations for recommended outlet pressure. Pressure is 100 psig unless otherwise noted.
+32° F. (0° C.) Minimum +115° F. (+46° C.) Maximum (See Warning on Impaired Burner Performance and Fire Hazard.)
Notice Special Requirements
12 Vdc ADC Burner Manual
If you discover damage to the burner or controls during unpacking, notify
the carrier at once and fi le the appropriate claim.
When contacting Beckett for service
information — Please record the burner serial number (and have available when calling or writing). You will fi nd the serial number on the silver label located on the left rear of the burner. See Figure 1.
3
Section: General Information
Adequate Voltage Required
A low or erratic power supply could result in impaired burner operation, severe delayed ignition
General Information
Refer to the Troubleshooting section of this manual when experiencing a possible fault condition.
or an explosion inside the heat exchanger resulting in a burn and/or asphyxiation hazard.
y The Model ADC requires a continuous supply of 11 to
16 volts DC at 15 amps measured at the burner during operation.
y An automotive or small engine charging system that is
capable of supplying the required continuous voltage/ amperage is recommended with certain road equipment, such as asphalt hot patchers and similar applications.
y This is especially true while maintaining nominal load
temperatures during idle periods.
Adequate Combustion and Ventilation Air Supply Required
Failure to provide adequate air supply could seriously affect the burner performance and result in damage to the equipment, asphyxiation, explosion or fi re hazards.
y The burner cannot properly burn the fuel if it is not
supplied with a reliable combustion air source.
y Follow the guidelines in the latest editions of the NFPA
31 and CSA-B139 regarding providing adequate air for combustion and ventilation.
Table 2. Air Tube Combination (ATC) Codes
Firing
Rate GPH
Head
Static
Plate
Size
ATC Codes for Usable Air
Tube Lengths:
(‘A’ in inches see Fig. 2)
A. Equipment Located in Confi ned Space
The confi ned space should have two permanent openings: one near the top of the enclosure and one near the bottom of the enclosure. Each opening shall have a free area of not less then one square inch per 1,000 BTU’s per hour of the total input rating of all equipment within the enclosure. The openings shall have free access to the building interior, which should have adequate infi ltration from the outside.
B.
Exhaust Fans and Other Air-Using Devices.
Size air openings large enough to allow for all air using devices in addition to the minimum area required for combustion air. If there is any possibility of the equipment room developing negative pressure (because of exhaust fans, for example), either pipe combustion directly to the burner or provide a sealed enclosure for the burner and provide it with its own combustion air supply.
C. Clearances to Burner and Equipment
Provide space around burner and equipment for easy service and maintenance. Check minimum clearances against those shown by the equipment manufacturer and by applicable codes.
D. Exhausting Hazardous Fumes
See warning on this page. Also be conscious of any fumes produced by the materials that are being heated. Always ensure adequate ventilation to exhaust all fumes.
min-max inches 4-1/2 5-3/8 6-5/8
0.40 - 0.75 F0 3-3/8U AF44XR AF53XR AF65XR
0.75 - 1.25 F3 2-3/4 AF44XN AF53XN AF65XN
0.85 - 1.35 F4 2-3/4 AF44WH AF53WH AF65WH
0.85 - 1.65 F6 2-3/4 AF44YB AF53YB AF65YB
1.10 - 2.00 F12 2-3/4 AF44XO AF53XO AF56XO
1.65 - 2.50 F22 2-3/4 AF44XP AF53XP AF56XP
*See page 3 for capacity and voltage specifi cations.
Figure 1. Typical Burner Nameplate
General Model Information
Serial Number
Including Date Code
Rating Information
Primary Group
and Fuel Oil
4
Table 1. Low Firing Rate Baffl e
Head Type
Low Firing Rate Baffl e (if specifi ed)
F0 up to 0.65 gph
F3 up to 0.85 gph
F4 or F6 up to 0.90 gph
R.W. Beckett Manufacturer’s Settings
R.W. Beckett Specification Number and Revision
Can Be Customized by Individual Specification
State & Local Approvals
RWB
Model " AFG " Series Oil Burner
000405-62736
R.W.Beckett Corp.
ELYRIA
OHIO U.S.A.
MFR'S SETTINGS
ATC:
AF65XN
FIRING RNG:
0.75-1.35 GPH F3HEAD:
SERIAL NUMBER
STC PLT:
2-3/4U
NOZZLE:
1.0 X 80B DLVN
PUMP PRS: 100 PSI
BJB3001 R00 000405-62736
Elyria, Ohio
Made in the U.S.A.
SK10090
Section: Nozzle Assembly Maintenance
E. Low Firing Rate Baffl e.
The low fi ring rate baffl e (See LFRB in Replacement Parts) reduces the air fl ow and pressure. The LFRB is sometimes used for fi ring rates under 1.00 gph as listed in
Table 1. Refer to the equipment manufacturer’s instructions. Do not omit the LFRB when specifi ed. Omitting the baffl e when specifi ed or installing the baffl e when not specifi ed could result in poor burner performance.
Nozzle Assembly
Maintenance
Correct Nozzle and Flow Rate Required
Incorrect nozzles and fl ow rates could result in impaired combustion, under­ ring, over-fi ring, sooting, puff-back of hot gases, smoke and potential fi re or asphyxiation hazards.
Use only nozzles having the brand, fl ow rate (gph), spray angle and pattern specifi ed by the appliance manufacturer.
Follow the appliance manufacturer’s specifi cations for the required pump outlet pressure for the nozzle, since this affects the fl ow rate.
y Nozzle manufacturers calibrate nozzle fl ow rates at
100 psig.
y When pump pressures are higher than 100 psig, the
actual nozzle fl ow rate will be greater than the gph stamped on the nozzle body. (Example: A 1.00 gph nozzle at 140 psig = 1.18 gph)
Securely tighten the nozzle (90 torque inch pounds). For typical nozzle fl ow rates at various pressures refer to Table 3.
2. Place a 3/4” open-end wrench on the nozzle adapter. Insert the nozzle into the adapter and fi nger tighten. Finish tightening with a 5/8” open-end wrench.
3. If the nozzle is already installed, remove the nozzle line assembly to verify that the nozzle size and spray pattern are correct for the application (per equipment manufacturer’s information). Verify that the electrode tip settings comply with Figure 2.
Use care when removing or installing an oil nozzle
A damaged nozzle could cause impaired combustion, sooting, puffback of hot gases, oil leakage and potential fi re or asphyxiation hazards.
y Inspect the nozzle adapter to insure that the sealing
surface is not grooved or scratched.
y To insure that the nozzle functions properly, check the
orifi ce and strainer for dirt, scratches or other damage before installation.
y Do NOT attempt to install or remove a nozzle without
securing the adapter to prevent seriously damaging the alignment.
y Use care when handling the nozzle line assembly
to prevent changing the electrode tip settings or damaging the ceramic electrode insulators.
y Ensure that the electrode settings match the values
shown in Figure 2.
Figure 2. Electrode Tip Setting
5/32” GAP
1/4” ABOVE
CENTER
A. Replace the Burner Nozzle.
1. If applicable, remove the plastic plug protecting the nozzle adapter threads.
Figure 5. Nozzle, Line & Electrode Assembly
Contacts to be parallel with
Electrode gap to be centered with nozzle center.
Item # Description
1 Electrode Contact (3” ATC or extension over 3”) 2 Nozzle Line 3 Spider spacer assembly 4 Static Plate 5 Electrode clamp 6 Electrode clamp retaining screws
12 Vdc ADC Burner Manual
horizontal center line within 2°.
11
10
9
1/8” NOZZLE-TO-TIP
6
8
1
2
7
4
Item # Description
7 Nozzle line setscrew 8 Electrode Insulator
9 Nozzle adapter 10 Nozzle tip 11 Electrode tip
SPACING
90°
3
5
4
5